• Title/Summary/Keyword: linac accelerator

Search Result 137, Processing Time 0.029 seconds

Design and Implementation of Solid-State Kicker Modulator for PLS-II (PLS-II 용 반도체 스위치 기반 키커 펄스 모듈레이터 설계 및 제작)

  • An, Suk-Ho;Kong, Hyung-Sup;Park, Wung-Hoa;Lee, Byung-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.307-308
    • /
    • 2019
  • The Pohang Light Source (PLS) - II is a 3 GeV third-generation synchrotron radiation facility. To inject electron beam from LINAC, a kicker modulator system and kicker magnets are installed in the PLS-II storage ring tunnel. The injected beam then falls into the storage ring beam dynamic aperture. This paper describes the design and implementation of the solid-state kicker modulator for PLS-II. The solid-state kicker modulator is consisted of high voltage solid state switch stacks. the technical considerations of the solid-state switch stacking for kicker modulator is discussed. The achieved capability of the solid-state kicker modulator demonstrates that is fulfills the design requirement of providing half-sine pulsed current of 10kA (peak), 6us (Base-width), with jitter < 2ns (Standard deviation). simulation and experimental results are presented to demonstrate the performance of the solid-state kicker modulator.

  • PDF

Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement (고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

Dose Characteristics of Stereotatic Radiosurgery CONE used for ML-6M Linear Accelerator (ML-6M LINAC에 장착한 Radiosurgery Cone의 Beam 특성에 대한 고찰)

  • Moon, Un-Chull;Kim, Hyun-Jin;Kim, Young-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.15-31
    • /
    • 1995
  • The radiosurgery treatment is one time, non surgical approach to the treatment of patients with intracranial disorders whose conditions would be difficult or dangerous to treat with conventional sugical procedures. The LINAC based radiosurgery is based on the combination of multiple isocentric arc irradiation with small fields centered in the stereotactic target. The absorption of the beam in a tissue equivalent medium, such as water, as well as the uniformity, or profile, of the beam must be precisely documented. The beam characteristics and dosimetric measurememts of the 6MV X-ray beam from a ML-6M linear accelerator are examined. The percent depth dose (PDD) and beam profile (including flatness, symmetry and penumbra) is calibrated with the radiosurgery cone in water phantom. The cone is made of lead which size is from $10{\times}10mm{\phi}$ to $30{\times}30mm{\phi}$ All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

Design of cryostat for superconducting quadrupole magnets in In-Flight fragmentation separator

  • Choi, Y.S.;Chang, H.M.;Baudouy, B.;Kim, D.G.;Kim, J.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.62-66
    • /
    • 2015
  • The cryostat is designed for the superconducting quadrupole magnets to be used in a heavy-ion accelerator facility. The main accelerator is superconducting linac, which can accelerate a $^{238}U$ beam to 200 MeV/u (Mega electron voltage per nucleon). The cryostat for the magnet employs an innovative design primarily driven by the requirement of the compactness, user-friendliness and reliability. Also, several ancillary requirements such as background field, space restriction due to the beam line and cryostat structure need technical attentions. The development of the cryostat for three quadrupole magnets in the in-flight fragmentation separator is presented in the paper. The concept of cryogenic design is reported and the amount of cryogenic load is estimated by a relevant analysis. The structure of the cryostat to endure the heavy iron yoke including three quadrupole magnets is presented. In addition, the design as well as the performance test of the support link for the cold mass is described.

A study on sub-nanosecoand pulser characteristic of electron gun (서브 나노초의 전자총 펄서 특성에 관한 연구)

  • Son, Y.G.;Jang, S.D.;Oh, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1662-1664
    • /
    • 2003
  • An electron gun system for a nanosecond pulse linac has been built and tested. The gun grid is driven with a grid pulser, which consists of an avalanche transistor pulser and parallel triode amplifier. The amplifier is installed in an end hole of the electron gun and provided for power amplification and polarity change of the output pulses of the avalanche transistor pulser. An output pulse of 200 V and 2 ns FWHM was obtained by using the grid pulser of can type transistors. Measurements with a test bench show that the electron gun can deliver 2ns pulse with with currents larger than 3A.

  • PDF

KICKER MAGNET MODULATOR IN PLS (포항방사광가속기 킼커 대출력 펄스전원장치)

  • Nam, S.H.;Jeong, S.H.;Han, S.H.;Suh, J.H.;Ha, K.M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1779-1781
    • /
    • 1997
  • The 2.0 GeV Pohang Light Source (PLS) is consisted of a full energy Linac and a storage ring. Four kicker magnets are installed in the storage ring tunnel to move the stored beam orbit in the storage ring closer to the injected beam from the beam transfer line. The injected beam then falls into the storage ring beam dynamic aperture. A kicker magnet modulator drives all four kicker magnets to maintain field balance and also synchronized kick of the beam. The kicker modulator can handle 2 GeV full energy beam. The kicker magnet modulator is installed in the storage ring tunnel and under stable operation. Specification of the kicker magnet modulator is ${\sim}6.0{\mu}s$ pulse-width, 200 ns flat-top width with ${\pm}0.2%$ regulation, ${\sim}24\;kA$ peak current, and 10 Hz repetition rate. Two thyratron switches (EEV CX-1536AX) are used in the system. In this article, design, and experimental results of the kicker magnet modulator are discussed.

  • PDF

Analysis of Radioactive Characterization in the Medical Linear Accelerator Shielding Wall Using Monte Carlo Method (몬테칼로법을 이용한 의료용 선형가속기 차폐벽의 방사화 특성 분석)

  • Lee, Dong-Yeon;Park, Eun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.758-765
    • /
    • 2016
  • This study analyzed for the radioactive shielding wall, which shields the medical linear accelerator. This allows to evaluate the level of waste with respect to the shield wall, which accounts for more than half of the cost of dismantling later linac facility. In addition, by analyzing the waste processing method according we discuss the way to obtain the benefits in terms of dismantling cost. Results of the simulate, the amount sufficient to screen the amount of neutron radiation occurring in the shielding wall linac was measured. And neutron activation analysis results were analyzed nuclides more than about 20. This analysis was in excess of that, $^{24}Na$, $^{45}Ca$, $^{59}Fe$ nucleus paper deregulation concentration. The value is reduced is greater the deeper the depth of the shielding wall concentration. Based on this, three specific areas (E, F, G) was estimated to be impossible to landfill or recycling. The rest area was estimated to be buried or recycled if possible more than a predetermined depth.

Evaluation of Comparison of Noise Power Spectrum according to the Time of Using Electronic Portal Imaging Device (EPID) for LINAC System (선형가속기의 시간에 따르는 전자조사문영상기구의 잡음전력스펙트럼 비교 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.117-123
    • /
    • 2024
  • This study was to assessment of quality assurance (QA) and noise characteristics of Noise Power Spectrum (NPS) according to the time of by using electronic portal imaging device (EPID) for LINAC (Linear Accelerator). LINAC device was (Varian ClinacR iX LINAC, USA) used and the were 40 × 30 cm2 of detector size were 1024 × 768 photo-electric diode array size. Signal could be obtained the K-space image of white noise images for NPS and we used to Overlap, Non-Overlap, Out of Penumbra, Flatness, Symmetry, Symmetry Rt, Lt methods. The 2013s NPS image Out of Penumbra quantitatively value more than 2013s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. Thus, the 2022s NPS image Out of Penumbra quantitatively value more than 2022s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. The assessment of comparison of white noise for NPS image noise and intensity of this study were to that should be used efficiently of the LINAC EPID detector system for Overlap method for International Electro-technical Commission (IEC).

Measurement of Energy Dependent Neutron Capture Cross Section of 99Tc

  • Lee, Sam-Yol;Lee, Sang-Bock;Lee, Jun-Haeng;Lee, Jeung-Min;Yoon, Jung-Ran
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.11a
    • /
    • pp.495-500
    • /
    • 2004
  • The neutron capture cross section of $^{99}Tc$ has been measured relative to the $^{10}B$(n,g) standard cross section by the neutron time-of-flight(TOF) method in the energy range of 0.007 eV to 47keV using a 46-MeV electron linear accelerator(linac) at the Research Reactor Institute, Kyoto University(KURRI). In order to experimentally prove the result obtained, the supplementary cross section measurement has been made from 0.3 eV to 1 keV using the Kyoto University Lead slowing-down Spectrometer(KULS) coupling to the linac. The relative measurement by the TOF method has been normalized to the reference value(20.01 b) at 0.0253 eV and the KULS measurement to that by the TOF method. The existing experimental data and the evaluated capture cross sections in ENDF/B-VI, JENDL-3.2, and JEF-2.2 have been compared with the current measurements by the linac TOF and the KULS experiments. The energy dependency of the KULS data is close to that of the TOF data which are energy-broadened by the resolution function of the KULS.

  • PDF

Resonance Integral of Neptunium(237Np) from Energy Dependent Differential Neutron Capture Cross-Section by Using the Linac TOF Method and C6D6 Scintillation Spectrometer

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.217-221
    • /
    • 2011
  • $^{237}Np$ is very important material in the fission products of nuclear reactors. Resonance integral(RI) tests of this material is necessary to check between the experiments and the evaluated data. Such feedback to the evaluated data is very important to correct data and improve of codes. The RI for the $^{237}Np(n,{\gamma})^{238}Np$ reaction were measured by using the 46-MeV electron linear accelerator (linac) at the Research Reactor Institute, Kyoto University (KURRI). The measurement was performed in the energy region from 0.005 eV and 10 keV. RI obtained as 804.7 barns, compared with those of the evaluated data in JENDL-4.0 and Mughabghab.