• 제목/요약/키워드: linac

검색결과 306건 처리시간 0.027초

Clinical Outcomes of Intracranial Nonvestibular Schwannomas Treated with Linac-Based Stereotactic Radiosurgery and Radiotherapy

  • Puataweepong, Putipun;Dhanachai, Mantana;Hansasuta, Ake;Saetia, Kriangsak;Dangprasert, Somjai;Sitathanee, Chomporn;Yongvithisatid, Pornpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3271-3276
    • /
    • 2016
  • Background: Intracranial nonvestibular schwannomas arising from various cranial nerves excluding CN VIII are uncommon. Recently, stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) have been widely reported as effective treatment modalities for nonvestibular schwannomas. The purpose of this study was to study the long term clinical outcome for nonvestibular schwannomas treated with both X-Knife and CyberKnife (CK) radiosurgery at one institution. Materials and Methods: From 2004 to 2013, fifty-two nonvestibular schwannoma patients were included in this study, 33 patients (63%) were treated with CK, and 19 (37%) were treated with X-Knife. The majority of the tumors were jugular foramen schwannomas (38%) and trigeminal schwannomas (27%). HSRT was given for 45 patients (86%), whereas CSRT was for 6 (12%) and SRS for 1 (2%). Results: The median pretreatment volume was $9.4cm^3$ (range, $0.57-52cm^3$). With the median follow up time of 36 months (range, 3-135), the 3 and 5 year progression free survival was 94 % and 88%, respectively. Tumor size was decreased in 13 (25%), stable in 29 (56%), and increased in 10 (19%). Among the latter, 3 (30%) required additional treatment because of neurologic deterioration. No patient was found to develop any new cranial nerve deficit after SRS/SRT. Conclusions: These data confirmed that SRS/SRT provide high tumor control rates with low complications. Large volume tumors and cystic expansion after radiation should be carefully followed up with neurological examination and MRI, because it may frequently cause neurological deterioration requiring further surgery.

민들레 추출물의 방사선 방호효과 (Radioprotective Effects of Dandelion(Taraxacum officinale))

  • 최준혁;지태정;민병인
    • 한국콘텐츠학회논문지
    • /
    • 제13권1호
    • /
    • pp.287-293
    • /
    • 2013
  • 민들레는 한방에서 산화방지, 위장 점막 보호 및 담즙 등에 탁월한 효과가 있다고 알려져 있다. 민들레 잎과 뿌리에서 추출한 물질을 SD Rat에 투여한 후 10Gy 방사선 조사 후에 생존율, 혈액변화, 소장조직변화 및 간 조직 변화를 관찰하였다. 관찰결과 민들레 추출물을 투여한 실험군에서 생존율이 4배 이상 높았으며 백혈구, 혈소판 등의 혈액변화에서도 뚜렷한 차이가 보였다. 또한 소장 조직 관찰결과 소장점막세포 소멸 억제 및 소장 점막근판 조직의 염증과 공포가 감소되었다. 따라서 민들레 추출물이 방사선 조사에 따른 혈액구성세포와 소장 조직 손상에 대한 방사선 방호효과를 확인하였다.

Geant4 전산모사 코드를 이용한 SBRT 환자의 선량분포 계산 (Calculation of Dose Distribution for SBRT Patient Using Geant4 Simulation Code)

  • 강정구;이정옥;이동준
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.36-41
    • /
    • 2015
  • 정위체부방사선수술(SBRT) 환자의 선량분포를 계산하기 위해 전산모사 방식을 이용한 응용프로그램을 개발 하였다. 본 소프트웨어는 최근 이용이 활발하게 증가하고 있는 Geant4를 기반으로 개발 하였다. 환자에 조사하기 위한 광자선 스펙트럼은 이전 연구에서 구한 선형가속기 스펙트럼 자료를 사용하였다. 치료계획시스템과 유사한 조사면을 구현하기 위하여 PrimaryGeneratorAction 클래스에서 MLC 조사면 형태를 반영하도록 하였다. 본 연구에서는 8개 조사면에 대한 계산을 수행하였으며 이 때 갠트리의 각도는 PrimaryGeneratorAction 클래스에서 회전 매트릭스를 사용하여 선원의 위치를 변경하는 방법을 사용하였다. 환자에 대한 물질 자료는 CT의 dicom 파일에서 픽셀 크기, 매트릭스 크기 등의 정보와 픽셀의 HU를 밀도로 변환한 파일을 생성한 다음 이 파일을 이용 환자의 모델링에 이용 하였다. 환자의 물질 구성과 기하학적 자료의 입력에 있어 EGSnrc 코드와의 비교를 통하여 계산의 효율성을 비교하였다.

방사선치료용 선형가속기를 이용한 Gated Cone-Beam CT의 유용성 연구 (Study on the Validation of the Gated Cone-Beam Computed Tomography on Radiation Therapeutic Linear Accelerator)

  • 서정민;김찬형;박병석;박철수;장현철;김정대
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6932-6939
    • /
    • 2015
  • 환자의 호흡은 방사선치료에서 중요한 인자로 작용한다. 종양을 치료하는 방사선 치료용 선형가속기에서 시행하는 기존의 cone-beam CT에서는 호흡에 의한 움직임이 반영되지 않아 영상에 왜곡이 발생하여 정확하지 못한 영상 정보를 획득하였다. 본 연구는 호흡에 의한 움직임을 고려하고 특정 순간을 포착한 gating을 적용하여 획득한 back projection 영상을 이용하여 cone-beam CT 영상으로 재구성하였으며 기존의 방법과 비교하였다. 기존의 방법은 영상 왜곡도가 400%에 달하였으나, 본 연구에서 시행한 gating을 적용한 cone-beam CT는 약 2%에 불과하였다. 이에 본 연구는 호흡의 움직임을 반영한 영상유도 방사선치료의 방향과 평가 방법을 제시하였다.

The Usefulness of Bolus of Radiation Therapy in Patients with Whole Breast Cancer

  • Min, Jung-Whan;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.99-103
    • /
    • 2011
  • Radiation Therapy has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internam mammary nodes and supraclavicular nodes. The purpose of this study is treated breast cancer patient to use 6 MV, 10 MV with bolus so that we observe changing of skin dose and evaluate those usefulness. Using woman's phantom, after CT simulate scanning, Through RTP system to make treatment plan, select three any place. And then, we measure that dose rate. After moving the phantom to linac, we put for TLD to three point same as RTP system which we put on the phantom. We exposed 6 MV, 10 MV with bolus and without so that it is measured dose by TLD device(4000 Harshaw). As a reult expose 6 MV,10 MV, it differences 10%, 15% according to bolus and withoout bolus where lateral point from RAO, LPO beam, other one is 20% where the furthest from both beams. To use bolus in the hospital is material to include closely part at skin among tissue of breast cancer. Acquired skin dose from RTP system is uncertainity. So it has to test another system likely TLD or other dosimetry system. Also exposed field of breast cancer is included inhomogeneity such as lung, bone and so on. Therefore it has to be accomplished a dose calculating of inhomogeneity part from treatment plan.

  • PDF

고에너지 방사선치료에서 차폐물 경계부위의 선량분포에 관한 고찰 (A Study on the dosimetry in boundary of shielding block in high energy irradiation)

  • 김명세;김성규;신세원
    • Journal of Yeungnam Medical Science
    • /
    • 제7권2호
    • /
    • pp.115-120
    • /
    • 1990
  • 18MeV 선형가속기와 코발트 원격치료기를 사용하여 방사선 조사면적 내에 차폐물이 있는 경우, 차폐물에 의한 산란선이 선량분포에 미치는 영향에 관하여 고찰하여 다음과 같은 결과를 얻었다. 1. 차폐물이 이루는 각이 예각일수록 산란선의 효과는 더 크게 나타났다. 2. 차폐물의 넓이가 좁을수록 산란선의 효과는 더 크게 나타났다. 3. 조사면적에 따른 출력특성은 선형적이지만, 차폐물에 의한 출력특성은 조사면적에 대하여 선형가속기는 거의 무관하게 나타났으며, 코발트 원격치료기는 기울기가 적은 선형성을 나타내었다.

  • PDF

정위 마스크 시스템을 사용한 방사선수술시 회전중심점의 재현성 (Isocenter Reproducibility with Mask Fixation System in Stereotactic Radiosurgery)

  • 이동준;손문준;이기택;최찬영;황금철;황충진
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.135-138
    • /
    • 2002
  • 치료대상 병소에 분할 방사선수술을 시술할 경우 회전중심(isocenter)은 정확하고 재현성 이 있어야 한다. 본 연구는 노발리스 방사선 수술장비와 정위 마스크 시스템을 사용한 분할방사선 수술에서 회전중심의 재현성을 측정하고 평가 하였다. 마스크는 열가소성 재질의 상용을 사용하였고 회전중심의 재현성을 측정하기 위해 고안된 머리 모양의 아크릴 팬텀에 맞도록 제작하였다. 팬텀의 내부에는 직경 5 mm의 아크릴봉을 수직으로 세우고 그 끝단을 회전중심으로 선택하였으며 예상되는 회전중심점에 pin hole을 낸 monochromic 필름을 설치하여 방사선 조사 후 회전중심의 재현성을 측정할 수 있도록 하였다. 측정 결과 회전중심은 공간오차가 평균 1 mm 이내이고 표준편차 또한 2 mm 이내여서 이미 보고된 타 문헌에서의 측정값과 비교해 볼 때 모든 측정값이 제시된 오차범위 내에 있었다. 결론적으로 분할방사선수술에 사용하는 정위 마스크 시스템은 매우 정확하고 재현성이 우수하였으며, 실제로 방사선 수술대상의 병소의 직경이 10 mm 정도 이상이라면 일반적인 한번의 고선량 방사선 수술에 정위 마스크 시스템의 사용이 가능할 것으로 사료된다.

  • PDF

고 강도 차폐벽돌을 이용한 방사선치료실의 차폐설계 (Design for Radiotherapy Room with High Density Shielding Block)

  • 서창옥;김귀언;추성실
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.247-254
    • /
    • 2004
  • 신체 심부의 악성종양치료를 위한 6~15 MV의 강력한 에너지의 방사선과 종양만을 조사하기 위한 입체조형치료, 세기 조절방사선치료, 입체적 치료방법 등이 개발됨으로써 방사선의 사출구가 전체 공간으로 확대되고 출력선량도 환자당 5~10 Gy의 과다 선량을 방출하기 때문에 고밀도의 차폐벽이 요구된다. 저자들은 세기조절방사선치료(IMRT)용 고 에너지 선형가속기를 기존건물에 설치하기 위하여 일반 콘크리트와 철, 티타늄등 중금속을 혼합한 고 밀도 차폐벽돌을 제작하여 방어벽을 설계하고 건축된 차폐벽으로부터 투과 산란된 선량을 측정하여 상호 비교하였다. 고 밀도 차폐벽돌을 사용함으로서 기존의 콘크리트(3.5 g/cc)에 비하여 고 에너지의 차폐율 즉 반가층 두께를 약 1/2로 줄일 수 있었다.

  • PDF

전자포탈영상 (EPI)을 이용한 의료용 선형가속기의 성능평가에 관한 연구 (A study of Quality evaluation for medical linear accelerator using Electronic Portal Imaging)

  • 윤성익;권수일;추성실
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.105-113
    • /
    • 1998
  • 고에너지 광자선을 발생시키는 의료용선형가속기의 선질은 경우에 따라 변이를 가져오게 된다. 이러한 변이를 정확하게 판정하여 줄 수 있는 방사선측정법의 활용은 매우 중요하다. 보편적으로 광자선의 측정에 있어서 전리함의 사용이 아주 빈번하였으나 전자포탈영상장치(EPID)의 등장은 새로운 방사선측정법에 대한 가능성의 시작을 예견해준다. 실험은 6MV 광자선의 대칭성, Light/Radiation congruence, 그리고 Wedge filter를 통한 간편한 에너지의 변화에측과 위치의 정확도에 대하여 측정을 시행하였다. 사실 방사선측정의 대표적인 방법은 물팬톰-전리함응 이용한 모델인데 본 실험에서는 영상의 화소가 지니는 디지탈 값을 적절한 소프트웨어로 읽어내어서 데이터를 환산하여 결과를 얻었다. 선행실험에서 얻은 상대선량률을 적용하여 대칭성에서는 조사야영역이 l0$\times$10$cm^2$ 일 때 횡축과 종축에서 1.2%, 1.2%로 비교적 오차가 적었다. 그리고 Light/Radiation field congruence 여부는 횡축이 0.3%, 그리고 종축이 0.2%로서 예상한 기대값에 접근하였다. 다음으로 wedge filter를 활용한 에너지의 변이와 위치의 정확도에 대한 움직임을 알 수 있었다.

  • PDF

의료용 선형가속기 출력측정용 듀얼윈도우 팬텀 개발 (Development of Dual-Window Phantom for Output Measurement of Medical Linacs)

  • 정동혁;곽동원;문영민;강영록;김정기;이만우
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.229-233
    • /
    • 2012
  • 광자선 출력측정시 업무 효율을 높이기 위한 소형 물팬톰(듀얼윈도우 팬톰)을 개발하였다. 이 팬톰은 고에너지 광자선의 출력측정뿐만아니라 선질지표의 결정에 적합하다. 이 팬톰은 두개의 창을 가지고 있으며 독립된 두 축에 의해 회전할 수 있도록 제작되어있다. 이 때 두 축은 전리함 이동 없이 조직팬톰선량비와 깊이선량율비를 결정하기 위한 것이다. 코발트조사기와 선형가속기의 고에너지 광자선을 이용하여 팬톰을 평가하였으며, 기준값과 비교할 때 Co-60의 경우 0.2% 그리고 가속기 x-선에 대해 1.4% 이내로 일치하였다. 이 팬톰은 발생 가능한 인적오차를 방지할 수 있기 때문에 일상의 출력측정에 매우 실용적이라고 본다.