• Title/Summary/Keyword: limiting

Search Result 3,858, Processing Time 0.028 seconds

Analysis on Current Limiting and Voltage Sag Compensating Characteristics of a SFCL using Magnetic Coupling of Parallel Connected Two Coils (병렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.2
    • /
    • pp.159-163
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the SFCL using magnetic coupling of two coils with parallel connection has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. In this paper, the current limiting and the voltage sag compensating characteristics of a SFCL using magnetic coupling of parallel connected two coils were analyzed. Through the analysis on the experimental results considering the winding direction of two coils, the SFCL designed with the additive polarity winding was shown to have the higher limited fault current than the SFCL designed with the subtractive polarity winding. In addition, it could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

Analysis of Fault Current Limiting Characteristics According to Variation of Fault Current level in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (사고전류 변화에 따른 일체화된 삼상자속구속형 고온초전도 사고전류제한기의 사고전류 제한 특성 분석)

  • Han, Byoung-Sung;Park, Chung-Ryul;Du, Ho-Ik;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.39-40
    • /
    • 2007
  • The analysis of fault current limiting characteristics according to variation of fault current level in the integrated three-phase flux-lock type superconducting fault current limiter (SFCL), which consisted of three-phase flux-lock reactor wound on an iron core with the same turn's ratio between coil 1 and coil 2 for each single phase, was performed. To analyze the current limiting characteristics of this integrated three-phase flux-lock type SFCL, the short circuit experiments was carried out the various three-phase faults such as the single line-to-ground fault, the double line-to-ground fault, the triple line-to-ground fault. From the experimental results, the fault current limiting characteristic was improved according to increase of fault current level.

  • PDF

Fault Current Limiting Characteristic of Flux-Lock Type HTSC Fault Current Limiter (자속구속형 고온초전도 전류제한기 사고전류제한 특성)

  • Lim, Sung-Hun;Choi, Myung-Ho;Park, Bok-Kee;Song, Jee-Joo;Park, Dae-Hee;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.105-108
    • /
    • 2002
  • In this paper, we investigated the fault current limiting characteristic of flux-lock type High-Tc superconducting fault current limiter(HTSC-FCL), which is comprised of a flux-lock reactor and an external magnetic field coil covering the HTSC element In this HTSC-FCL, the initial limiting current level can be controlled by adjusting the inductance of the each coil. Furthermore, the fault current limiting characteristics of HTSC-FCL can be improved by applying 'the external magnetic field into the HTSC element We performed the computer simulation by numerical analysis about the flux-lock type HTSC-FCL and compared the results of experiment with simulation ones. We can obtain the same results from both the computer simulation and the experiment except for the time immediately after fault occurs.

  • PDF

Evaluation on the Properties of the Current Transporting Part for Fault-Current-Limiting Type HTS Cables (사고전류 제한형 고온 초전도케이블의 통전부 특성평가)

  • Kim, Tae-Min;Hong, Gong-Hyun;Han, Byung-Sung;Du, Ho-Ik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.10
    • /
    • pp.657-661
    • /
    • 2014
  • When an abnormal condition occurs due to a fault current at a consumer location where electricity is supplied through high-Tc superconducting(HTS) cable, the HTS cable would be damaged if there is no appropriate method to protect it. The fault-current-limiting type HTS cable that is suggested in this study has a structure of transport part and limit part. It conduct a zero impedance transport current at ordinary operations and carry out a fault current limiting at extraordinary operations. To make a perfect this structure, it is essential to investigate electrical properties of transport part that comprise the fault-current-limiting type HTS cable. In this paper, transport part that comprise HTS wire with copper stabilization layer is examined the current transport properties and the stability evaluation.

Characteristics of a 190 kVA Superconducting Fault current Limiting Element (190 kVA급 초전도한류소자의 특성)

  • Ma, Y.H.;Li, Z.Y.;Park, K.B.;Oh, I.S.;Ryu, K.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.37-42
    • /
    • 2007
  • We are developing a 22.9 kV/25 MVA superconducting fault current limiting(SFCL) system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric field during fault of the power network, was selected as a candidate for our SFCL system. In this work, we experimentally investigated important characteristics of the 190 kVA Bi-2212 SFCL element in its application to the power grid e.g. DC voltage-current characteristic, AC loss, current limiting characteristic during fault, and so on. Some experimental data related to thermal and electromagnetic behaviors were also compared with the calculated ones based on numerical method. The results show that the total AC loss at rated current of the 22.9 kV/25 MVA SFCL system, consisting of one hundred thirty five 190 kVA SFCL elements, becomes likely 763 W, which is excessively large for commercialization. Numerically calculated temperature of the SFCL element in some sections is in good agreement with the measured one during fault. Local temperature distribution in the190 kVA SFCL element is greatly influenced by non-uniform critical current along the Bi-2212 bulk SFCL element, even if its non-uniformity becomes a few percentages.

Breakdown Characteristics of FLR(Field Limiting Ring) with Buried Ring (Buried ring이 있는 FLR(Field Limiting Ring) 구조의 항복특성)

  • Yun, Sang-Bok;Choi, Yearn-Ik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1686-1688
    • /
    • 1999
  • The FLR(Field Limiting Ring) structure with a buried ring is proposed to improve breakdown voltage. The breakdown characteristics of proposed structure is verified by two-dimensional device simulator. ATLAS. It has shown that the breakdown voltage of the proposed structure is increased by 11 % compared with that of the FLR.

  • PDF

Adjustment of a Studentized Test Statistic and a Normalized Test Statistic in a Simple Linear Structural Relationship

  • Chang, Kyung
    • Journal of Korean Society for Quality Management
    • /
    • v.21 no.2
    • /
    • pp.156-161
    • /
    • 1993
  • Limiting distributions of Studentized test statistics have been shown for testing the slope parameter in a simple linear structural model. Since the limiting distribution of Studentized one appears to yield inaccurate inference, this paper suggests adjustment of critical value and normalization of the Studentized one. As results, we can have procedures for refined inference based on our approximate distrbution instead of the limiting distribution.

  • PDF

The Rao-Robson Chi-Squared Test for Multivariate Structure

  • Park, Cheol-Yong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.4
    • /
    • pp.1013-1021
    • /
    • 2003
  • Huffer and Park (2002) proposed a chi-squared test for multivariate structure. Their test detects the deviation of data from mutual independence or multivariate normality. We will compute the Rao-Robson chi-squared version of the test, which is easy to apply in practice since it has a limiting chi-squared distribution. We will provide a self-contained argument that it has a limiting chi-squared distribution. We study the accuracy in finite samples of the limiting distribution. We finally compare the power of our test with those of other popular normality tests in an application to a real data.

  • PDF

THE LIMITING SPECTRAL DISTRIBUTION FUNCTION OF LARGE DIMENSIONAL RANDOM MATERICES OF SAMPLE COVARIANCE TYPE

  • Choi, Sang-Il
    • Journal of applied mathematics & informatics
    • /
    • v.5 no.2
    • /
    • pp.465-474
    • /
    • 1998
  • Results on the analytic behavior to the limiting spectral distribution of matrices of sample convariance type. studied in Marcenko and Pastur [2] are derived. using the Stieltjes transform it is shown that the limiting distrbution has a continuous derivative away from zero the derivative being analytic whenever it is positive and the behavior of it resembles the behavior of a square root function near the boundary of its support.