• Title/Summary/Keyword: limiter function

Search Result 32, Processing Time 0.022 seconds

Analysis on a Saturating System with an Intelligent Limiter (지능적인 제한기를 갖는 포화 시스템에 관한 해석)

  • Yang, Sang-Sik;Hong, Suk-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.4
    • /
    • pp.417-426
    • /
    • 1991
  • All mechanical systems have saturation nonlinearity in actuators or in final control elements. When controllers have an integral action, reset windup can cause instability as well as make the system performance unsatisfacdtory. This paper presents an analysis of the stability of the control system with antireset-windup limiter, called intelligent limiter, using the describing function method. The responses of the system with this limiter are illustrated by computer simulation.

Analysis on the Operational Characteristic between the Protective devices and Superconducting Fault Current Limiter with a Peak Current Limiting Function in the Power Distribution System (피크전류 제한 기능을 갖는 초전도한류기의 계통 적용에 따른 보호기기간 동작특성 분석)

  • Cho, Yong-Sun;Kim, Jin-Seok;Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.75-80
    • /
    • 2012
  • In this paper, the operational characteristics due to the introduction of the superconducting fault current limiter(SFCL) with a peak current limiting function were analyzed in the power distribution system. The parallel structure of the superconducting element can operate the peak current limiting function depending on the transient amplitude of fault current. We studied the operating characteristics of the introduction of the SFCL with a peak current limiting function in the power distribution system. Furthermore, we were analyzed between the SFCL with a peak current limiting function and the protection devices in the power distribution system, through the short circuit experiments.

Analysis on a saturating system with an intelligent limiter

  • Yang, Sang-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.1091-1096
    • /
    • 1989
  • All mechanical systems have saturation nonlinearity in actuators or in final control elements. When controllers have integral action, reset windup can cause instability as well as make the system performance unsatisfactory. In this study, an intelligent limiter which needs no tuning of parameters is tested with the PDF controller used for control of a second order plant. This paper presents analysis of the stability of the system using the describing function method and the Nyquist stability theorem. The improvement of the system performance by the limiter is illustrated by computer simulations.

  • PDF

The Optimal Design of DC Reactor Type Superconducting Fault Current Limiter using Newton Method (Newton Method를 이용한 DC Reactor Type 한류기의 최적설계)

  • 서호준;고태국;이승제
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.330-333
    • /
    • 2002
  • This study is concerned with the optimal design of DC reactor type high-Tc superconducting fault current limiter(SFCL) by Newton method. What should be first thought over in developing SFCL is the condition in which the cost function is minimized under given constraints. So, this condition is supposed to be the values corresponding to the variables the cost function counts on. In this paper, we got the result for the SFCL available at the level of 6.6kV-200A by means of simulation.

  • PDF

Analysis on Current Limiting Characteristics of a Superconducting Fault Current Limiter (SFCL) with a Peak Currnt Limiting Function (피크전류제한 기능을 갖는 초전도한류기의 전류제한 특성분석)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.47-51
    • /
    • 2011
  • The superconducting fault current limiter (SFCL) with a peak current limiting function according to the initial fault current with the different amplitudes was suggested. The proposed SFCL, which consists of two limiting components, causes only the first superconducting element among two limiting components to be quenched in case that the initial fault current with the lower peak amplitude happens. On the other hand, the initial fault current with the higher peak amplitude makes both the superconducting elements of two limiting components to be quenched, which contributes to the peak current limiting function of the SFCL. To confirm the fault current limiting operation of the proposed SFCL, the short-circuit tests of the SFCL according to the fault angle were carried out and its effective fault current limiting operations could be discussed.

Analysis on Fault Current Limiting Characteristics According to Peak Current Limiting Setting of a Flux-Lock Type SFCL with Peak Current Limiting Function (피크전류제한 설정에 따른 피크전류제한 기능을 갖는 자속구속형 초전도한류기의 고장전류제한 특성 분석)

  • Ko, Seok-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.68-73
    • /
    • 2012
  • In this paper, the fault current limiting characteristics of a flux-lock type superconducting fault current limiter (SFCL) with peak current limiting function were analyzed through its short-circuit tests. The setting condition for the peak current limiting operation was derived from its electrical equivalent circuit, which was dependent on the inductance ratio between the third coil and the first coil. Through the analysis on the short-circuit tests for the flux-lock type SFCLs with the different inductance ratio between the third coil and the first coil, the setting value for the peak current limiting operation of the flux-lock type SFCL with peak current limiting function could be confirmed to be adjusted with the variation of the inductance ratio between the third coil and the first coil.

Size Optimization of Impact Limiter in Radioactive Material Transportation Package Based on Material Dynamic Characteristics (재료동특성에 기초한 방사성물질 운반용기 충격완충체의 치수최적설계)

  • Choi, Woo-Seok;Nam, Kyoung-O;Seo, Ki-Seog
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.20-28
    • /
    • 2008
  • According to IAEA regulations, a transportation package of radioactive material should perform its intended function of containing the radioactive contents after the drop test, which is one of hypothetical accident conditions. Impact limiters attached to a transport cask absorb the most of impact energy. So, it is appreciated to determine properly the shape, size and material of impact limiters. A material data needed in this determination is a dynamic one. In this study, several materials considered as those of impact limiters were tested by a drop weight facility to acquire dynamic material characteristics data. Impact absorbing volume of the impact limiter was derived mathematically for each drop condition. A size optimization of impact limiter was conducted. The derived impact absorbing volumes were applied as constraints. These volumes should be less than critical volumes generated based on the dynamic material characteristics. The derived procedure to decide the shape of impact limiter can be useful at the preliminary design stage when the transportation package's outline is roughly determined and applied as input value.

  • PDF

A Study on DC Interruption Technology using a Transformer Type Superconducting Fault Current Limiter to Improve DC Grid Stability (DC 그리드 안정성 향상을 위해 변압기형 초전도 한류기가 적용된 직류 차단 기술에 관한 연구)

  • Hwang, Seon-Ho;Choi, Hye-won;Jeong, In-Sung;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.595-599
    • /
    • 2018
  • Interruption system with the transformer type superconducting fault current limiter(TSFCL) is proposed in this paper. The interruption system with a TSFCL is a technology that it maximizes the interruption function of a mechanical DC circuit breaker using a transformer and a superconducting fault current limiter. By a TSFCL, the system limits the fault current till the breakable current range in the fault state. Therefore, the fault current could be cut off by a mechanical DC circuit breaker. The Interruption system with a TSFCL were designed using PSCAD/EMTDC. In addition, the Interruption system with a TSFCL was applied to the DC test circuit to analyze characteristics of a current-limiting and a interruption operation. The simulation results showed that the Interruption system with a TSFCL interrupted the fault current in a stable when a fault occurred. Also, The current-limiting rate of the Interruption system with a TSFCL was approximately 69.55%, and the interruption time was less than 8 ms.

COMPARATIVE STUDY ON FLUX FUNCTIONS AND LIMITERS FOR THE EULER EQUATIONS (Euler 방정식의 유량함수(Flux Function)와 제한자(Limiter) 특성 비교 연구)

  • Chae, E.J.;Lee, S.
    • Journal of computational fluids engineering
    • /
    • v.12 no.1
    • /
    • pp.43-52
    • /
    • 2007
  • A comparative study on flux functions for the 2-dimensional Euler equations has been conducted. Explicit 4-stage Runge-Kutta method is used to integrate the equations. Flux functions used in the study are Steger-Warming's, van Leer's, Godunov's, Osher's(physical order and natural order), Roe's, HLLE, AUSM, AUSM+, AUSMPW+ and M-AUSMPW+. The performance of MUSCL limiters and MLP limiters in conjunction with flux functions are compared extensively for steady and unsteady problems.

Development of Integrated Mixer Controller for Digital Public Address (디지털전관방송을 위한 통합믹서컨트롤러 개발)

  • Cho, Juphil;Kim, Kwan-Woong;Kim, Daeik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.19-24
    • /
    • 2017
  • Nowadays, based on the advancement of IT techniques, innovative products combining IT techniques to PA system are developing. In this paper, we presented the hybrid mixer controller for digital PA system. We develop the integrated mixer controller which includes the digital mixer composing an existing digital PA system and function of digital integrated controller. Developed integrated mixer controller consists of multichannel mixer function with 16 audio input channels, 8 output channels. And, it has an equalizer for processing digital audio signal, matrix and limiter. Also, the developed controller has some features such as internet connection for controlling of overall PA system and remote monitoring of mixer process condition.