• 제목/요약/키워드: limit in distribution

검색결과 1,129건 처리시간 0.024초

FORM 및 SORM을 이용한 무어링 체인의 신뢰성 기반 결함평가 (Reliability-based Flaw Assessment of a Mooring Chain Using FORM and SORM)

  • 이충현;김유일
    • 대한조선학회논문집
    • /
    • 제54권5호
    • /
    • pp.430-438
    • /
    • 2017
  • This study presents the reliability-based flaw assessment for the crack in the mooring chain of a floating type offshore structure. BSI(British Standard Institution) flaw assessment procedure BS7910 was combined with first- and second-order reliability method (FORM, SORM) so that the acceptance of a given flaw can be assessed considering the uncertainties of parameters that play important role in the flaw assessment. Considering the probabilistic nature of the crack size and long-term distribution of the stresses acting on the crack in mooring chain, the failure probability was calculated using FORM and SORM. To check the validity of the FORM and SORM, Monte Carlo simulation was also carried out to derive the true limit state function and compared with the results of FORM and SORM.

Factors affecting hydraulic anisotropy of soil

  • Nurly Gofar;Alfrendo Satyanaga;Gerarldo D. Aventian;Gulnur Pernebekova;Zhanat Argimbayeva;Sung-Woo Moon;Jong Kim
    • Geomechanics and Engineering
    • /
    • 제36권4호
    • /
    • pp.343-353
    • /
    • 2024
  • The hydraulic anisotropic behavior of unsaturated soil has not been fully explored in relation to the grain-size distribution. The present study conducted laboratory assessments to examine the hydraulic anisotropy condition of statically compacted specimens in various initial states. The investigation incorporated the concept of hydraulic anisotropy by employing two discrete forms of soil stratification: horizontal-layering (HL) and vertical-layering (VL). The examined soils comprised sandy silt and silty sand, exhibiting either unimodal or bimodal soil-water characteristic curve (SWCC). This study aimed to investigate the potential correlation between the hydraulic anisotropy ratio and soil properties. The present study established a correlation between the hydraulic anisotropy ratio and several soil parameters, including fine content, dry density, plastic limit, and liquid limit. The study results indicate a non-linear relationship between the percentage of fine and dry density in soils with unimodal and bimodal soil-water characteristic curve (SWCC) and hydraulic anisotropy ratio.

배수관망의 잔류염소 평활화를 위한 최적 재염소 처리 (Optimal Rechlorination for the Regulation of Chlorine Residuals in Water Distribution Systems)

  • 윤재흥;오정우;최영송
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.90-98
    • /
    • 1998
  • The optimal rechlorination in water distribution systems was investigated by incorporating optimization techniques into a numerical water quality model. For a hypothetical system that consists of 10 junctions including a storage tank and 12 links, the bulk ($k_b$) and pipe-wall ($k_w$) decay-rate constants of chlorine residual are assumed to be 2.0 1/day and 1.5 m/day, respectively. It was also assumed that the lower and upper limits of chlorine residual in the network are 0.2 mg/L and 0.6 mg/L. When the chlorine source is only the storage tank (without rechlorination), the high levels of chlorine residual appear near the storage tank to maintain the chlorine residuals above the lower limit over the junctions. On the other hand, the chlorine residuals in the network are distribute within the desirable range (0.2 - 0.6 mg/L) after the optimal rechlorination through five injection sites including the storage tank. In case of a real water distribution system that comprises 28 junctions including a clear well and 27 links, the bulk and pipe-wall decay-rate constants are 0.3 1/day and 0.2 m/day, respectively. Before rechlorination, the required chlorine residual at the clearwell is 5.1 mg/L to keep the chlorine residuals above the minimum level (0.6 mg/L) over the junctions. By the optimal rechlorination at five injection sites, the chlorine residuals are distributed within a desirable range of 0.6 mg/L through 2.0 mg/L, which can avoid the excess of chlorine residuals near the clear well. Consequently, total chlirine doses are decreased by 81% in the hypothetical distribution network and 69 % in the real distribution network for satisfying the minimum chlorine residuals.

  • PDF

열화상 이미지 분석을 통한 배전 설비 공정능력지수 감지 시스템 개발 (Identifying Process Capability Index for Electricity Distribution System through Thermal Image Analysis)

  • 이형근;홍용민;강성우
    • 품질경영학회지
    • /
    • 제49권3호
    • /
    • pp.327-340
    • /
    • 2021
  • Purpose: The purpose of this study is to propose a system predicting whether an electricity distribution system is abnormal by analyzing the temperature of the deteriorated system. Traditional electricity distribution system abnormality diagnosis was mainly limited to post-inspection. This research presents a remote monitoring system for detecting thermal images of the deteriorated electricity distribution system efficiently hereby providing safe and efficient abnormal diagnosis to electricians. Methods: In this study, an object detection algorithm (YOLOv5) is performed using 16,866 thermal images of electricity distribution systems provided by KEPCO(Korea Electric Power Corporation). Abnormality/Normality of the extracted system images from the algorithm are classified via the limit temperature. Each classification model, Random Forest, Support Vector Machine, XGBOOST is performed to explore 463,053 temperature datasets. The process capability index is employed to indicate the quality of the electricity distribution system. Results: This research performs case study with transformers representing the electricity distribution systems. The case study shows the following states: accuracy 100%, precision 100%, recall 100%, F1-score 100%. Also the case study shows the process capability index of the transformers with the following states: steady state 99.47%, caution state 0.16%, and risk state 0.37%. Conclusion: The sum of caution and risk state is 0.53%, which is higher than the actual failure rate. Also most transformer abnormalities can be detected through this monitoring system.

지리정보시스템을 이용한 가야산국립공원의 잠재자연식생 추정 (Simulation Map of Potential Natural Vegetation in the Gayasan National Park using GIS)

  • 김보묵;양금철
    • Ecology and Resilient Infrastructure
    • /
    • 제4권2호
    • /
    • pp.115-121
    • /
    • 2017
  • 본 연구는 가야산국립공원을 대상으로 지리정보시스템(Geometric Information System, GIS)을 이용 식생분포에 영향을 미치는 요인들을 분석하여, 식생분포 확률을 기초로 가야산국립공원의 잠재자연식생을 추정하였다. 가야산국립공원의 현존식생조사 결과 128개의 군락이 분포하는 것으로 나타났다. 가야산국립공원의 고도, 경사, 사면방위, 지형지수, 연평균 온도, 온량지수, 잠재증발산량의 7개 요인을 중심으로 군락별 분포를 분석하였으며, 이를 바탕으로 분포확률을 추정하였다. 잠재자연식생의 분포확률이 0.3이상인 군락은 소나무군락의 출현확률이 55.80%로 가장 높았으며, 신갈나무군락이 44.05%, 상수리나무군락이 0.09%, 굴참나무군락이 0.06%로 나타났다. 식생의 분포에 영향을 주는 요인을 본 연구에서 제시한 요인으로 한정할 경우 가야산국립공원의 잠재자연식생은 신갈나무군락(43.1%)과 소나무군락(56.9%)이 나타날 것으로 예측되었다.

Distribution of shear force in perforated shear connectors

  • Wei, Xing;Shariati, M.;Zandi, Y.;Pei, Shiling;Jin, Zhibin;Gharachurlu, S.;Abdullahi, M.M.;Tahir, M.M.;Khorami, M.
    • Steel and Composite Structures
    • /
    • 제27권3호
    • /
    • pp.389-399
    • /
    • 2018
  • A perforated shear connector group is commonly used to transfer shear in steel-concrete composite structures when the traditional shear stud connection is not strong enough. The multi-hole perforated shear connector demonstrates a more complicated behavior than the single connector. The internal force distribution in a specific multi-hole perforated shear connector group has not been thoroughly studied. This study focuses on the load-carrying capacity and shear force distribution of multi-hole perforated shear connectors in steel-concrete composite structures. ANSYS is used to develop a three-dimensional finite element model to simulate the behavior of multi-hole perforated connectors. Material and geometric nonlinearities are considered in the model to identify the failure modes, ultimate strength, and load-slip behavior of the connection. A three-layer model is introduced and a closed-form solution for the shear force distribution is developed to facilitate design calculations. The shear force distribution curve of the multi-hole shear connector is catenary, and the efficiency coefficient must be considered in different limit states.

가공식품 중 육류 함량을 고려한 일상적인 육류 섭취량 분포 추정 연구: 국민건강영양조사 자료(2009년) 활용 (Estimation of Usual Meat Intake Distribution Considering Meat Content in Processed Foods: Based on the KNHANES 2009)

  • 신윤정;김애정;김동우
    • 대한지역사회영양학회지
    • /
    • 제25권2호
    • /
    • pp.150-158
    • /
    • 2020
  • Objectives: This study was conducted to estimate usual meat intake distribution, which may have been over/underestimated when estimations were made using only the third food codes of the Korea National Health and Nutrition Examination Survey (KNHANES). Methods: For this purpose, 24-hour recall data from the 2009 Korea National Health and Nutrition Examination Survey, which conducted a partial 2-day survey of food intake, were used. The Multiple Source Method (MSM) was used to estimate the distribution of the usual intake of red and processed meats. Results: The results of this study show that the mean intake of red meat was 45.07 g while that of processed meat was 4.33 g. These results are slightly higher than the consumption calculated using only tertiary food code, and the difference was statistically significant. Furthermore, characteristics of the estimated usual intake distribution were a smaller standard deviation, increased lower percentiles, and decreased upper percentiles compared to the 2-day mean intake distribution for both red and processed meats. The proportion of individuals not consuming red meat decreased substantially from approximately 37% to 0.7%. The proportion of consumption that exceeded 90 g, which is the upper limit of red meat intake recommended by the National Health Service (NHS), was only approximately 10% in the distribution of usual intake. Conclusions: As the consumption of processed foods is expected to continuously increase, caution is needed regarding the processes used to calculate food (group) intake to avoid over/underestimation. Moreover, use of KNHANES data to calculate the proportion of the population at risk of insufficiency or excess intake of certain nutrients or food (group), based on one day intake that does not address within-individual variation, may lead to biased estimates.

무치악에 대한 최소 임플란트의 구조물의 3차원 유한요소 해석 (The 3-Dimensional Finite Element Analysis of Minimum Implant Structure for Edentulous Jaw)

  • 장인식
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.148-155
    • /
    • 2008
  • The aim of the study is to interpret the distribution of occlusal force by 3-dimensional finite element analysis of ISP(Implant Supported Prosthesis) supported by minimum number of implant to restore the edentulous patients. For this study, the Astra Tech implant system is used. Geometric modeling for 6 and 4 fixture ISP group is performed with respect to the bone, implant and one piece superstructure, respectively. Implants are arbitrarily placed according to the anatomical limit of lower jaw and for the favorable distribution of occlusal force, which is applied at the end of cantilever extension of ISP with 30mm. Element type is tetrahedral for finite element model and the typical mechanical properties, Young's modulus and Poisson's ratio of each material, cortical, cancellous bone and implant material are utilized for the finite element analysis. From this study, we can see the distribution of equivalent stress equal to real situation and speculate the difference in the stress distribution in the whole model and at each implant fixture, From the analysis, the area of maximum stress is distributed on distal contact area between bone and fixture in the crestal bone. The maximum stress is 53MPa at the 0.2mm area from the bone-implant interface in the maximum side for 300N load condition for 4 fixture case, which is slightly less than the stress calculated from allowable strain. This stress has not been deduced to directly cause the loss of crestal bone around implant fixture, but the stress can be much reduced as the old peoples may have lower chewing force. Thus, clinical trial may be performed with this treatment protocol to use 4 fixtured ISP for old patients.

스테인리스-알루미늄 클래드 강판재의 원형컵 온간 성형성 연구 (Investigation of Formability of Cylindrical Cups in Warm Drawing of Stainless-Aluminum Clad Sheet Metal)

  • 류호연;김영은;김종호
    • 대한기계학회논문집A
    • /
    • 제24권1호
    • /
    • pp.87-93
    • /
    • 2000
  • Warm, forming technique which is one of the new forming technologies to improve formability of sheet metal is applied to the cylindrical cup drawing of stainless-aluminum. clad sheets. In experiments the temperature of die and blank holder is varied from room temperature to 18$0^{\circ}C$, while the punch is cooled by circulation of coolant to increase the fracture strength of workpiece on the punch corner area. Test materials chosen for experiments are STS304-A1050-STS304, STS304-A1050-STS430 clad sheets and A1050-0 aluminum sheet. Teflon film as a lubricant is used on both sides of a workpiece. The limit drawing ratio as well as quality of drawn cups(distribution of thickness and hardness)are investigated and validity of warm drawing process is also discussed.

제주 해양환경에 적합한 부유식 해상풍력발전기 계류선 설계 (Design of Mooring Lines of a Floating Offshore Wind Turbine in South Offshore Area of Jeju)

  • 정준모;김형준;전기영
    • 대한조선학회논문집
    • /
    • 제51권4호
    • /
    • pp.300-310
    • /
    • 2014
  • This paper presents a mooring design procedure of a floating offshore wind turbine. The environment data of south offshore area of Jeju collected from Korea Hydrographic and Oceanographic Administration(KHOA) are used for hydrodynamic analyses as environmental conditions. We considered a semi-submersible type floating wind turbine based on Offshore Code Comparison Collaborative Continuation(OC4) DeepCWind platform and National Renewable Energy Laboratory(NREL) 5 MW class wind turbine. Catenary mooring with studless chain is chosen as the mooring system. Important design decisions such as how large the nomial sizes are, how long the mooring lines are, how far the anchor points are located, are demonstrated in detail. Considering ultimate limit state and fatigue limit state based on 100-year return period and 50-year design life, respectively, longterm predictions of breaking strength and fatigue are proposed.