• Title/Summary/Keyword: lightweight concrete wall

Search Result 37, Processing Time 0.026 seconds

Development of Non-flammable exterior design Molding using Cellular Light-weight Concrete (CLC를 활용한 공동주택 불연성능 외벽몰딩 개발)

  • Kwon, Hae-Won;Gong, Min-Ho;Lee, Chang-Yong;Jeong, Gab-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.54-55
    • /
    • 2020
  • Recently, "The rules on the standards of evacuation and fire protection of buildings" require that non-burnable materials such as non-combustible and semi-non-combustible materials be used as the materials applied to the building's exterior walls, but styrofoam, which is a combustible material, has been applied a lot and became a social issue. In this study, we developed a non-combustible outer wall molding to secure construction and economic feasibility and free expression using CLC(CLC: Cellular Light-weight Concrete).

  • PDF

The Development of Steel-plate Concrete Panels with Preplaced Lightweight Aggregates Concrete (프리플레이스트 경량골재 콘크리트를 사용한 합성형 구조모듈 제작 및 성능 평가)

  • Yoon, Jin Young;Kim, Jae Hong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • The steel-plate concrete(SC) is used in a form of module assembly construction in the outer wall of nuclear-power plant and LNG containment. Since the steel-plate concrete modules are generally manufactured from the plant, the weight of SC has significantly effect on the total construction cost in the aspect of shipment. Therefore, the use of lightweight aggregates concrete(LWAC), which fill the inside of SC module can be a solution. However, the amount of used lightweight aggregates(LWA) is limited in the use of current concrete mixing process due to the concrete quality problems and it also determines the allowable minimum density of LWAC. In this research, the preplaced casting method is applied because of increasing the volume fraction of LWA significantly, which results from the producing process of pre-packing the LWA in the formwork and filling the interstitial voids between LWA using cement paste grout. The density and compressive strength of selected preplaced LWAC were $1,600kg/m^3$ and 30MPa and it was applied for the mock-up specimens of SC panel. It was used for the 3-point bending test for evaluating its structural performance. The results show that the preplaced LWAC can reduce the density of concrete with the adequate mechanical and structural performance.

A study on the Application of Inorganic Reinforced Non-Flammable Molding to Building Exterior (무기계보강 CLC 불연몰딩의 건축물 외벽적용 연구)

  • Kwon, Hae-Won;Gong, Min-Ho;Lee, Chang-Woo;Choi, Byung-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.61-62
    • /
    • 2021
  • Exterior wall molding, which is widely applied as a design element of the exterior wall of domestic apartment, should be applied as a nonflammable or semi-nonflammable material grade according to the rules on standards for evacuation/fire protection structures of buildings. For this reason, stone and AL sheet are mainly used, but stone is expensive and design autonomy is low. Inorganic reinforced CLC nonflammable molding was applied to the exterior wall of the building through tests of nonflammable performance, noise reduction, and installation stability.

  • PDF

Unconfined compressive strength property and its mechanism of construction waste stabilized lightweight soil

  • Zhao, Xiaoqing;Zhao, Gui;Li, Jiawei;Zhang, Peng
    • Geomechanics and Engineering
    • /
    • v.19 no.4
    • /
    • pp.307-314
    • /
    • 2019
  • Light construction waste (LCW) particles are pieces of light concrete or insulation wall with light quality and certain strength, containing rich isolated and disconnected pores. Mixing LCW particles with soil can be one of the alternative lightweight soils. It can lighten and stabilize the deep-thick soft soil in-situ. In this study, the unconfined compressive strength (UCS) and its mechanism of Construction Waste Stabilized Lightweight Soil (CWSLS) are investigated. According to the prescription design, totally 35 sets of specimens are tested for the index of dry density (DD) and unconfined compressive strength (UCS). The results show that the DD of CWSLS is mainly affected by LCW content, and it decreases obviously with the increase of LCW content, while increases slightly with the increase of cement content. The UCS of CWSLS first increases and then decreases with the increase of LCW content, existing a peak value. The UCS increases linearly with the increase of cement content, while the strength growth rate is dramatically affected by the different LCW contents. The UCS of CWSLS mainly comes from the skeleton impaction of LCW particles and the gelation of soil-cement composite slurry. According to the distribution of LCW particles and soil-cement composite slurry, CWSLS specimens are divided into three structures: "suspend-dense" structure, "framework-dense" structure and "framework-pore" structure.

Verification of Reinforcing Arrangement Error in Precast Concrete Shear Walls Using BIM and Presentation of Flexural Ductility Model (BIM을 이용한 프리캐스트 콘크리트 전단벽의 배근 오류 검증 및 휨 연성 모델 제시)

  • Ju-Hyun Mun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.27-36
    • /
    • 2024
  • This study established a BIM procedure considering manufacturing errors in the production process, and evaluated the flexural ductility of precast all-lightweight aggregate concrete special shear walls (PLASWs) with spliced sleeve technique. In the production process, the concrete cover thickness of PALSW was on average 1.28 times greater than the cross-sectional details of the specimen modeled with Revit BIM program. In particular, the bending inner radius of the hoop and inner-cross tie were greater than the designed details. Consequently, the confinement effect of core concrete reduced from 64% to 54% due to the manufacturing errors in the transverse reinforcing bars, resulting in a decrease in the ductility of PALSW by approximately 4.91%. Considering these findings, the BIM of PLASW with spliced sleeve technique should compliment the bending inner radius of the transverse reinforcing bars, and the defined brittleness increase coefficient reflecting the decreased core concrete confining pressure in the stress-strain relationship of confined concrete should be evaluated as 1.8.

Experimental and numerical analysis of new bricks made up of polymer modified-cement using expanded vermiculite

  • Koksal, Fuat;del Coz Diaz, Juan J.;Gencel, Osman;Alvarez Rabanal, Felipe P.
    • Computers and Concrete
    • /
    • v.12 no.3
    • /
    • pp.319-335
    • /
    • 2013
  • In this paper, the properties of the cement mortar modified with styrene acrylic ester copolymer were investigated. Expanded vermiculite as lightweight aggregate was used for making the polymer modified mortar test specimens. To study the effect of polymer-cement ratio and vermiculite-cement ratio on various properties, specimens were prepared by varying the polymer-cement and vermiculite-cement ratios. Tests of physical properties such as density, water absorption, thermal conductivity, three-point flexure and compressive tests were made on the specimens. Furthermore, a coupled thermal-structural finite element model of an entire corner wall was modelled in order to study the best material configuration. The wall is composed by a total of 132 bricks of $120{\times}242{\times}54$ size, joined by means of a contact-bonded model. The use of advanced numerical methods allows us to obtain the optimum material properties. Finally, comparisons of polymer-cement and vermiculite-cement ratios on physical properties are given and the most important conclusions are exposed.

Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior (ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구)

  • Kim, Young-Ho;Lee, Yong-Soo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.

Analysis of Characteristics and User's Evaluation for Lightweight Panel in Apartment (공동주택 경량칸막이 벽체구성재 분류별 사용자 평가 및 특성 분석)

  • Park, Hyeon-Ku
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.181-191
    • /
    • 2010
  • Lightweight panels are currently used in many ways, such as inner walls of the skyscrapers and residential buildings in Korea. Moreover there has been an increasing of interest in developing construction method and quality improvement as many buildings became higher, because there are more advantages like constructability, finishability, and economic efficiency, etc. than previous heavy weight concrete wall. It is necessary to analyze the characteristics and evaluate the performance of lightweight panels when selecting proper methods and materials to building characteristics and builder's demand. However, there doesn't exist systematic data with a classification of lightweight panels' type and performance. The purpose of this study is to classify domestic lightweight panels by both type of exterior board and construction method, and also to evaluate each performance by surveying user's opinion.

Research on the Load Reduction Effect Using EPS (EPS의 압축성을 이용한 토압저감효과에 관한 연구)

  • 김진만;조삼덕;최봉혁;오세용
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.101-108
    • /
    • 2004
  • For the last 30 years, the use of EPS as a lightweight filling material has grown significantly throughout the world. The fields of applying EPS block have also increased. The most representative example in geotechnical applications is using EPS block as a compressible inclusion that causes the reduction of static earth pressure on earth-retaining wall, bridge abutment and pipes. EPS blocks have a good workability by its lightweight characteristic and a uniform engineering property with the change of its density. Also EPS blocks have best material property as a compressible inclusion. This paper analyzes that the compressible inclusion function of EPS causes the reduction of static earth pressure on retaining wall and concrete box culvert. A series of in-situ tests were conducted to evaluate the reduction of static earth pressure using EPS inclusion. Based on in-situ test, it is found that the magnitude of static earth pressure was reduced to about 20% for the retaining wall and about 45∼53% for the box culvert compared with theoretical active earth pressure.

A Study on the Improvement of the Floor Impact Sound Insulation Performance in Wall Slab Type Apartment (벽식구조 공동주택의 바닥충격음 개선에 대한 연구)

  • Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.73-81
    • /
    • 2012
  • Floor impact sound has been most annoying for years among the noises which are produced in apartment. This study aims to analyze the improvement of floor impact sound by comparing the results of the test which was carried out for the wall slab type apartment and moment frame apartment, and also for the effect of advanced vibration isolation layer. Moment frame structure that main structure consists of column and slab has shown better performance for the heavyweight impact sound comparing with wall slab type structure which is general type in Korea. Stiffness of floor system was raised by reinforcing the stiffness of vibration isolation layer, and it was analyzed how much the floor impact sound performance was improved. The result showed that the reinforced floor had better performance than the existing floor system that uses lightweight porous concrete as vibration isolation material. In addition, a system used wire mesh in mortar showed improvement of floor impact sound than a system without wire mesh, and better performance for the frequency bands lower than 160 Hz which causes floor impact problem in wall slab type apartment.