• Title/Summary/Keyword: lighting-control

Search Result 820, Processing Time 0.024 seconds

Analysis of Simulation of Daylight and Experiment for Determining on Effective Dimming Ratio (효과적인 조광제어시스템 적용을 위한 주광시뮬레이션과 실험데이터 분석)

  • Kim, Ga-Young;Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • This study proposes to increase the energy-saving effects by reducing excessive intensity of radiation of artificial lighting through analyzing daylight incident. A photosensor sends amounts of detected luminous flux to digital control unit(DCU) as a signal and then, it can decide dimming ratios, received a proper dimming signal from DCU. Generally it is effective to control artificial lighting with the different control ratio of each zone by setting a photosensor as same number and rows as artificial lighting. However, it is ineffective to do in initial costs of systems aspect in offices. As a result of grasping the distribution of daylight previously and analyzing daylight and dimming data, we can dim different dimming ratios to each zone of artificial lighting by a single photosensor.

Environment Design for Digitalized Main Control Room in Nuclear Power Plant

  • Cha, Woo Chang
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 2011
  • The purpose of the Environment Design (ED) for Main Control Room (MCR) of Nuclear Power Plant (NPP) is to provide and create an optimal working space to be free from physical, physiological and mental stress as well as environmental discomfort, based on the previous environment design experiences and to recommend the best ED including the color, the lighting and the interior design. Environment Design consists of three main areas: Human factor engineering design, Interior design with color design, and Lighting design. These design areas have been interactively cooperated in a way that each design specialist would share the objectives and concepts of the Environment Design for MCR. The specialists for Human Factors Engineering design had a corporative role in such a way to provide the guidelines for MCR design suitability of Interior and Lighting design considering the Human System Interface (HSI) safety concerns. This paper describes fruitful efforts to create the best fit for MCR ED among several design proposals with the design recommendations, impacts, and contributions to NPP environment.

Development of KNX/EIB-based Communication Module (KNX/EIB 프로토콜 기반의 통신 모듈 개발)

  • Park, D.K.;Lee, W.S.;Hong, S.H.;Hwang, T.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.420-422
    • /
    • 2007
  • Nowadays, the demand for home networking system is gradually increasing. But most of vendors use their own protocols. KNX/EIB ( European Installation Bus / Konnex) is a standard protocol approved as an European (EN 50090 - EN 13321-1) and a World-wide standard (ISO/IEC 14543). In this study, we develop on/off and dimming lighting control system using BIM. In this system, BIM communicates to micro-controller using PEI(Physical External Interface) communication. And this enables including more KNX/EIB communication objects in lighting control system, and providing lighting control algorithm. The technology in this paper can help to adapt the world-wide standards.

  • PDF

Development of a Lighting Control Switch Using Power Line Communication Technology (전력선 통신기술을 이용한 조명제어 스위치의 개발)

  • Song, Jae-Yong;Seo, Hwang-Dong;Moon, Seung-Bo;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.299-303
    • /
    • 2005
  • A lighting control switch, extended to incorporate a power line communication technology, is developed. The system uses not an exclusive microprocessor but a general one, and developed PPM protocol. The coupling circuit is a type of an isolation LC filter, and the impedance of the circuit was designed as low as possible to extend signal transmission distance. The frequency of the carrier, considering the data length and signal attenuation as the length of power lines, was set at 250 kHz. Tests on a prototype in an indoor power lines have shown that the switch has a stable operation with the distance of power lines

  • PDF

The Stabilized Flyback Converter Design for Lighting Control System (경관조명용 플라이백 컨버터의 안정화 설계)

  • Lim, Seong-Jin;Kim, Chang-Sun;You, Jin-Ho;Cheon, Seung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.9-10
    • /
    • 2010
  • The lighting control power circuits should be designed in stable region according to the environment. A stable circuit is analyzed using ac equivalent circuits. The flyback converter with wide input voltage ranges is suitable for lighting control system. It is designed optimally for stability. The specifications are that the input voltage is 90V-230V, the output power is 12V/2.5A. The stability analysis is established using PSM(Phase Sensitive Multimeter) in experiment. As a result, it is confirmed that the gain margin and the phase margin are in stable area. The validity of the experimental measurement is verified.

  • PDF

The Summer Cooling and Lighting Energy Performance Evaluation of Small Office Buildings with Venetian Blinds (블라인드를 고려한 여름철 소규모 사무소 건물의 냉방 및 조명에너지 평가)

  • Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • The daylighting control system has to be applied to prevent the excessive incident daylight and reduce energy use. As the one of the most useful daylighting control systems, the blind system is simple and easy to install on the window for small office buildings. This study aims to evaluate the summer energy performance of small office buildings by venetian blinds and energy saving strategy of ministry of knowledge economy in korea. For the study, the simulations have been executed on blind installation conditions and lighting control methods. As results, the energy loads cut down 22 to 25(%) by using blind energy. Also, the efficient shows high on EMS system and low on $45^{\circ}$ slat angles. Also, using energy saving strategy can reduce about 13(%) energy load.

Design of Neuro-Fuzzy LED Emotional Lighting System for Concentration and Resting Situations in Indoor Environment (실내 환경 집중 및 휴식상황에서의 뉴로-퍼지를 통한 LED 감성조명 시스템 설계)

  • Kang, Eun-Yeong;Kim, Hyo-Jun;Park, Keon-Jun;Kim, Young-Kab
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.558-566
    • /
    • 2015
  • LED, the next-generation light source, rapidly develops and has advantages of low power, high efficiency, and long life. Accordingly, an interest in lightings by using LED rises. If emotional lighting is implemented by using LED, all colors can be represented by using 3 primary colors of light, differently from the conventional single-color lighting. LED emotional lightings which can control human emotions continue to be developed thanks to these advantages. This study was conducted to design an algorithm for expressing LED emotional lighting in line with the situation and temperature by extracting colors for concentration and resting situations in indoor environment and mixing them with colors of the temperature felt by user. The LED emotional lighting designed with a neuro-fuzzy system was found to have effects on user's emotions during concentration and resting.

Design of LED Driving Circuit using Voltage Controlled Ring Oscillator and Lighting Controller (전압제어 링 발진기를 이용한 LED구동회로 및 조명제어기설계)

  • Kwon, Ki-Soo;Suh, Young-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.1-9
    • /
    • 2010
  • An LED driving and control circuit has been developed. The LED driver has a new PWM circuit for current control of LED columns with dimming, current and thermal control, and communication functions. The PWM circuit is composed of two ring oscillator and one counter which can be constructed using basic digital logic components. In addition, it has the functions of remote control mode such as ON, OFF, emergency and power saving modes by the serial communication. The PWM generator and control circuit have been designed and fabricated 0.35[${\mu}m$] Magnachip/Hynix digital IC fabrication process. The LED driving and control board using the developed chip is fabricated and tested successfully.

Design of Bi-directional RDM-DMX512 Converter for LED Lighting Control

  • Hung, Nguyen Manh;Lee, Chang-Hoon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.106-115
    • /
    • 2013
  • LED lighting control system using unidirectional DMX512 (digital multiplex with 512 pieces of information)) protocol has been the most popular. Nowadays, the user's consumption has been upgrading to the more intelligent system but the upgrading process does not affect the existing infrastructure. There were many researches use the additional communication for the feedback communication way such as WiFi, Controller Area Network (CAN), Power Line Communication (PLC), etc but all researches had inherent disadvantages that created the independent feedback with the existing DMX512 system. Our paper represents the novel method that uses the remote device management (RDM) protocol to associate the additional feedback with existent DMX512 infrastructure in the one system. The data in DMX512 frame sending to the DMX512 client is split and repacked to become the RDM packet. This RDM packet is transferred to the RDM monitor console and the response RDM packet is converted to the DMX512 frame for control DMX512 client devices. This is the closed loop control model which uses the bidirectional convertibility between RDM packet and DMX512 frame. The proposed method not only upgrades the feedback control function for the old DMX512 system without changing the existent infrastructure, but also solves compatible problems between new RDM devices and old DMX512 devices and gives the low cost solution for extending DMX512 universe.

Evaluation of Lighting Energy Saving Rate in a Small Office Space (소규모 사무공간의 조명에너지 절감율 평가에 관한 연구)

  • Kim, Han-Yong;Yun, Gyeong;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.50-58
    • /
    • 2012
  • The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m.