• Title/Summary/Keyword: lighting intensity

Search Result 247, Processing Time 0.049 seconds

The Nutrients Removal in Aerobic High Rate Ponds Through the Lighting Period (빛의 조사기간으로 본 호기성 고율 안정조 프로세스의 영양물질 제거)

  • 공석기
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.83-91
    • /
    • 1996
  • It is not too much to say that the territorial inhabitants' concerns are wholly c concentrated on the environmental preservation-problem and development-problem in Korea given effect to the local self-government system. At a time like this I was studied the effect on nutrients removal through lighting period in aerobic high rate pond and we know that waste stabilization pond method is the most economical and energy saving wastewater treatment technology than others. At the results which was studied through operating the reactor-l artifically main-tained at a temperature, $25^{\circ}C$, a light intensity, 3000lux, and a lighting period, 24hrs and the reactor-2 artifically maintained at a tern야rature, $25^{\circ}C$ and a light intensity 3000lux, and a lighting period period, 12hrs, It has appeared for 24hrs.-lighting period -reactor-1 to be prior to the reactor-2. The attained results are that 1. reactor-1 is prior to reactor-2 on oxygen-generation 2. reactor-1 is prior to reactor-2 on algal production 3. COD removal efficiency, 90.76%, T-N removal efficiency, 80%, T-P removal e efficiency, 74.47 % in reactor-2, in reactor-1 COD removal efficiency, 94.85 %, T-N removal efficiency, 98.07%, T-P removal efficiency, 72.13% are, so the treatment efficiency of reactor-1 is more excellent than things of reactor-2 4. it appeared that the detention time is 8, 9days.

  • PDF

Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires (간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.

A Study on the Cost Effective DSM Method for Lighting Power Control through Pilot Test Based on Pre-Verified Methodologies (다양한 형태의 조명(형광등) 전력제어 실증시험을 통한 비용효과적인 전력수요관리방법 도출)

  • Yang, Seung-Kwon;Kim, Dae-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.7-13
    • /
    • 2013
  • The portion of lighting power consumption for our country is up to 20~30% of the total amount. Currently, most of the DSM(Demand side management) of lighting power is delivered in supply of high efficient lighting to customers. On the contrary, applications of lighting power to power load leveling are still rare. In this paper, the simulations for various control types of lighting power for load leveling are tried, and we obtained the cost effective and optimal control method through that. This simulation was executed in test office with fluorescent light by us based on applying 8 control types(on, off & dimming), considering customers' satisfaction, for instance, minimum intensity of illumination allowed. According to the result of this test, we found that mixed type(chessboard(on-off) plus dimming control(10%)) is most effective.

Correlation Analysis between Space Integration and Natural Light in K Senior Hospitals (K 노인전문병원의 공간 통합도와 자연광의 상관관계 분석)

  • Moon, Sun-Young;Lee, Hyun-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2015
  • In case of Senior Hospitals, meticulous care is required in both amount and quality of natural lighting because of the semi-long term residence of patients. Natural lighting has a huge impact on the physical and psychological part for the seniors. Likewise, natural lighting is an important factor considered for hospital design because it can also effect hospitalization period of patients. Research subject was K Senior Hospital which was determined as the courtyard-type building made to provide healing environment through natural lighting. Analysis was performed by dividing the space of K Senior Hospital into Central Treatment Department directly used by patients, Outpatient Department(OPD), Ward Department, Common Use Department. Research was carried out in two ways of integration value analysis using SPACE SYNTAX and illumination intensity analysis using ECOTECT. K Senior Hospital intended to actively let in natural light through courtyard and to make patients exposed to natural light when they walk along the circuit corridor built around the courtyard. This environmental consideration affected the utilization rate of Common Use Department and residence time of patients raising the average of Common Use Department on every floor. As a resuit of this study presenting type C and type D, part of four types of illumination intensity, takes higher percentage of almost every spaces compare to the others therefore K Senior Hospital was designed on the assumption of healing environment composition through natural light. The result of this research would be used meaningfully in the space programming phase of Senior Hospitals in the future. Utilization rate can be adjusted using illumination intensity value in the space that integration rate should be planed to be high. The use(purpose) of space and integration rate can be used as a guideline to set illumination intensity of natural.

Vegetative Growth Characteristics of Phalaenopsis and Doritaenopsis Plants under Different Artificial Lighting Sources

  • Lee, Hyo Beom;An, Seong Kwang;Lee, Seung Youn;Kim, Ki Sun
    • Horticultural Science & Technology
    • /
    • v.35 no.1
    • /
    • pp.21-29
    • /
    • 2017
  • This study was conducted to determine the effects of artificial lighting sources on vegetative growth of Phalaenopsis and Doritaenopsis (an intergeneric hybrid of Doritis and Phalaenopsis) orchids. One - month - old plants were cultivated under fluorescent lamps, cool - white light - emitting diodes (LEDs), or warm - white LEDs at 80 and $160{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. The blue (400 - 500 nm) : green (500 - 600 nm) : red (600 - 700 nm) : far - red (700 - 800 nm) ratios of the fluorescent lamps, cool-white LEDs, and warm-white LEDs were 1 : 1.3 : 0.8 : 0.1, 1 : 1.3 : 0.6 : 0.1, and 1 : 2.7 : 2.3 : 0.4, respectively. Each light treatment was maintained for 16 weeks in a closed plant-production system maintained at $28^{\circ}C$ with a 12 h photoperiod. The longest leaf span, as well as the leaf length and width of the uppermost mature leaf, were observed in plants treated with warm-white LEDs. Plants grown under fluorescent lamps had longer and wider leaves with a greater leaf span than plants grown under cool-white LEDs, while the maximum quantum efficiency of photosystem II was higher under cool-white LEDs. The vegetative responses affected by different lighting sources were similar at both 80 and $160{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Leaf span and root biomass were increased by the higher light intensity in both cultivars, while the relative chlorophyll content was decreased. These results indicate that relatively high intensity light can promote vegetative growth of young Phalaenopsis plants, and that warm - white LEDs, which contain a high red-light ratio, are a better lighting source for the growth of these plants than the cool-white LEDs or fluorescent lamps. These results could therefore be useful in the selection of artificial lighting to maximize vegetative growth of Phalaenopsis plants in a closed plant - production system.

A Study on the Convertible Emergency Lighting Fixture in Consideration of Dark Adaptation (암순응을 고려한 겸용형 비상조명등에 관한 연구)

  • Yum, Sung-Bae;Yoon, Cheol-Gu;Lee, Jung-Eun;Shin, Hye-Young;Song, Young-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.24-29
    • /
    • 2011
  • When an emergency light turns on due to a blackout, the intensity of illumination is drastically changed from hundreds [1x] to 1.0[1x]. This sharp change of illumination intensity not only lowers the darkness adaptation of the eye, it also degrades the obstacle cognitive ability of the evacuees, resulting in secondary critical accidents due to anxiety, and fear. Thus, this study proposed a convertible emergency lighting fixture that controls the rate of speed of light in two stages by time with darkness adaptation of the eye in consideration. In addition, the effect of such emergency light is verified by suggesting an illumination simulation without increasing the number of light or capacity of battery to make it economically feasible.

A Optical System Design of LED Marine Lanterns Based on a TIR Collimator Lens (전반사 렌즈를 이용한 LED 등명기 광학계 설계)

  • Go, Dong Hyun;Lee, Yoon Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.1-5
    • /
    • 2015
  • In this paper, we propose the optical system design for a medium sized LED marine lanterns which simplifies the multi-layer structure into a single structure. In order to satisfy the target fixed intensity(35,000cd) and vertical divergence($-2.5^{\circ}{\sim}-4.0^{\circ}$, $+2.5^{\circ}{\sim}+4.0^{\circ}$), we use the total internal reflection collimator lens. And a Monte Carlo simulation has been utilized to optimize a condition of a LED package, TIR lens and outside lens. The computer simulation results indicated that this LED marine lanterns can produce of a fixed intensity(35,382cd) and vertical divergence($-3.1^{\circ}{\sim}+2.5^{\circ}$). Using the this optical system, we achieve the target value of LED lanterns.

Study of Efficiency Test and Subjective Responses about Pendent Task Lighting System Using Phosphor Luminescent Film LED (광기여 필름 LED 팬던트 작업조명시스템 주관평가와 성능검증)

  • Cha, Kwang-Seok;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.188-193
    • /
    • 2011
  • For a long time work or study, pendent task lighting system prepared with phosphor luminescent film LED was developed for eye protection and working efficiency improvement. Developed lighting system was used together with pendent and ambient lighting. Such as, we made comfortable lighting environment system. Evaluation for developed lighting system, that had proceeded to Mock-up test and subjective evaluation. Also It had proceeded that lighting environment analyzed and compatibility valuation of installation. In subjective evaluation, the students have expressed themselves satisfied to phosphor luminescent film LED lighting system. In Mock-up test, It is not problem to intensity of illumination, luminance and color temperature. Therefore, developed LED lighting system was installed at the Daegu apartment. It is having a P.O.E study progress to phosphor luminescent film LED lighting system.

Design and Implementation of LED Dimming System with Intelligent Sensor Module

  • Cho, Young Seek;Kwon, Jaerock;Kim, Hwan-Yong
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • An intelligent light emitting diode (LED) dimming system is designed and implemented for energy-saving lighting systems. An LED light bulb is powered by an LED driver controlled by a microcontroller using pulse width modulation (PWM) signals. By changing the duty cycle of the PWM signals, the LED driver generates a driving current of up to 1,000 mA. The current consumption by the LED light bulb exhibits a very linear characteristic that indicates that the level of LED dimming can be finely tuned. Multiple sensors-lighting intensity and ultrasonic range sensors-are combined with the LED dimming system to realize an automatically controllable LED lighting system. The light intensity sensor is capable of sensing ambient light. The ultrasonic range sensor can detect objects from 0.15 to 5.6 m at a resolution of 0.0254 m. The collected information by the light intensity and ultrasonic range sensors is processed by the microcontroller that in turn automatically controls the brightness of the LED light bulb. The algorithm of the software for the LED dimming system is also described.

Design of a lighting system for PCB visual pattern inspection (인쇄회로기판의 패턴 검사용 조명장치 설계)

  • Na, Hyun-Chan;Rho, Byung-Ok;Ryu, Yung-Kee;Cho, Hyung-Suck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1997
  • Austomated visual inspection(AVI) capability has become an important key component in the automated manufacturing system. In such a visual inspection system an intensity(or color) image of a scene is quickly affected by optical property of objects, condition and roughness of surface, lens and filters, image sensor property and lighting system. In particular, the lighting system disign is the most important factor, since it affects overall performance of the visual system. For fast and cheap automated visual inspection system it is important to obtain the good image quality which results from careful attention to the design of the lighting system. In this paper, the lighting subsystem of AVI system is analysed for the inspection of printed circuit board(PCB) patterns. The spectral reflectance of materials, which are composed of PCB, is measured for choosing the light source. The reflection property is theoretically obtained by a reflection model and also obtained by experiments which measure intensity with varying the viewing direction of image sensor and the lighting direction of illuminator. The illumination uniformity of a ring-type illuminator. The lighting system is designed based upon the experimental results and theoretial analysis.