• Title/Summary/Keyword: lighting energy

Search Result 677, Processing Time 0.025 seconds

Management System of USN-based Collaborative Lighting Energy (USN기반 참여형 조명에너지 관리시스템)

  • Kim, Sam-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.47-53
    • /
    • 2013
  • Nowadays, Advanced country have devised a plan energy-saving through lighting effectiveness and increasing performance of lighting control system. If it uses the LED as a source of light then conserve electricity by 50%. This paper implement LEMS(Lighting Energy Management System) that applicate and Smart Dimmer and Smart Switch that control the digital LED light, support wired-wireless communication using USN(Ubiquitous Sensor Network). This system of validity and reliability control special purpose lamp including indoor and outdoor lighting and landscape lighting effectively. It minimize the use of indoor and outdoor lighting energy by USN remote integral control function of Digital System Lighting of LED and increase effectiveness of energy and is a collaborative system that can feedback the use of electricity by measurement itself through Web and Switch.

Proposal of Lighting Power Density for Road Lighting (도로종류에 따른 조명전력 허용기준([W/m2]) 제안)

  • Lee, Sang-Jin;Lee, Min-Wook;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.42-47
    • /
    • 2011
  • The design of road lighting is aiming illuminance and luminance requirements for road lighting. In the process, various factors associated with luminaires such as luminous efficacy, light distribution, mounting height, spacing and maintenance factor are considered. However, there has been no restriction on lighting power density. In this study, lighting power density has been comparatively analyzed through a study of related data and a result of measurements on domestic roads. And, it has been analyzed by simulation results for road in which lighting conditions are variable. In terms of the limitation on power density for road lighting, road lighting can be designed using high efficacy lighting systems for energy saving.

A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting (조명발열 배기시스템의 배기위치에 따른 배기열량 실험연구)

  • Oh, Byung-Kil;Chung, Min-Ho;Won, Jong-Seo;Lee, Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • This study aims to reduce cooling energy by grasping kinds of heating load in building in order to decrease cooling energy in summer and eliminate efficiently heating load. Lighting heating value was confirmed through examination and experiment concerning lighting heating and reducible exhaustion value was extracted lighting apparatus. The optimal exhaust system by air conditioning type was suggested for applying lighting heat exhaust system and the method contributing to promotion supplying low energy architecture was suggested by predicting reduced cooling load.

Analysis of the Electrical and Optical Properties in Omnidirectional LED Bulbs by Energy Star (Energy Star 기준에 따른 Omnidirectional LED 벌브의 전기적 광학적 특성 분석)

  • Kim, Yu-Sin;Bae, Ho-June;Kim, Gi-Hoon;Kim, Hyun-Sik;Song, Sang-Bin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.750-754
    • /
    • 2012
  • An LED (light emitting diode) has the advantages of lower power consumption, energy saving, high efficiency, long lifetime, and environmental friendliness so that it has been getting the spotlight as a next-generation light source. Thus, the application range of an LED has been extended to various fields including indoor and outdoor lighting. Recently, the high efficient LED lighting has been developed, an LED has been extended its market rapidly every year and is expected to replace the general light source within near future. In this study were measured electrical and optical properties for 6 types of LED bulbs which are being developed to replace the general incandescent lamps, and were analysed under the standard of the omnidirectional lamp required by the Energy Star.

Evaluation on the lighting performance of a dynamic LED lighting system (동적 LED 시스템의 조명원적 성능분석)

  • Kim, Hyo-In;Kim, Jeong-Tai;Yun, Geun-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • LED lighting has received much attention in recent years due to its high energy efficiency and environmental friendliness. As the color of light can be obtained by adjusting the light intensity of LEDs, the quality of visual environment can be improved. The aims of this study are to develop a wavelength adjustable LED lighting system and to examine its lighting performances. The LED lighting system and experimental cell for assessment of the lighting performance were constructed. This LED lighting system is able to materialize the various spectral power distribution and color temperature of light through the control of the four dimmers. Up to $432^4$ kinds of light combinations are possible. The range of illuminance on workplane were measured as 7~1,831 ㏓. Improvement of psychological and physical functions for occupants can be expected according to control of lighting performances.

Comparative Studies on Lighting Environment and Energy Performance depending on the Transmittance of Window and Slat Angle of Blind (창호의 투과율과 블라인드 슬랫각도에 따른 빛환경 및 에너지성능 비교 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.256-263
    • /
    • 2011
  • Recently, curtain wall structure is constructed according to increasing high rise building. Glass is usually used in opening of curtain wall structure and window area ratio is finally increased. Excessive Daylighting and solar radiation by large window area ratio cause discomfort glare and add to cooling load in the case of office that is heavy on lighting and cooling. Therefore, this study suggests to use low transmittance window for solve those problems. Indoor lighting environment and building energy performance were analyzed by increasing transmittance from 10% to 90% and comparing fixed venetian blind. Consequently, the range of transmittance that is possible to daylighting and prevent discomfort glare. Secondary energy consumption is efficient in the case that transmittance is the range of from 20% to 50%, primary energy consumption is nice on from 20% to 40%. If those result put together, the range of window transmittance from 30% to 50% is proper in the office in lighting environment and energy consumption aspects.

  • PDF

A Study on Savings Analysis of Light Dimming Control System Using the Daylight based on Photovoltaic Power Generation (태양광발전 기반의 주광을 활용한 조명제어 시스템의 에너지 절감량 분석 연구)

  • Ham, Won-Tae;Jang, Cheol-Yong;Jeong, Hak-Guen
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.11-21
    • /
    • 2012
  • In the normal office building, the energy consumption to maintain the reasonable intensity of illumination for the work by using the artificial illumination occupies 30% or greater of the whole building electric energy consumption. If the dependability of the artificial illumination is dropt by positively using the natural lighting from the outside, the large amount of electrical energy can be saved, in addition the more nice visual environment for work can be created. Daylight is lighting source that most closely match visual response of the human, because sunlight and skylight achieve the harmony. For this reason, the daylight of small amount than amount of the artificial lighting source also can give the same effect in work activities of human. In addition, if there is daylight at the window of the building, the energy can be saved by controlling the artificial lighting. In this paper, in the building using the photovoltaic power generation analyze the correlation between the amount of energy generated by photovoltaic and indoor illumination and this was proved through the simulation with Relux 2010. In addition, the amount of daylight inflow in the room and distribution was drawn by the equation and the ratio for the sectional dimming control of each lighting equipment was predicted and the energy saving amount according to this was calculated. As a result, the indoor illumination was satisfied with recommended illumination value of the office and consumption power could be reduced approximately with 20~70%.

Energy Efficient Lighting Control Facilities Related to Daylight Levels (주광(晝光) 대등형 가변조명(可變照明) 제어설비의 적용 및 통합성능)

  • Kim, Jeong-Tai;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.8-15
    • /
    • 2006
  • To reduce costs and address other practical concern related to architectural lighting, we have been involved in various aspects of advanced daylighting design and control. If we look toward future building trends, we see that the advanced has already successfully deployed such complex lighting control systems. This paper takes a broad view of what advanced manufacturers have done to develop energy efficient lighting control technologies such as sensors, lumen maintenance, time of day scheduling, peak demand reduction and so forth. First of all strategies, daylighting controls would also need to be commissioned to respond to the specific daylighting signature of the zone. To translate the daylight in term of the amount of energy savings, an electric lighting system is designed and automatic on-off control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. The lighting analysis program, Lumen-Micro predicts the optimal layout of conventional fluorescent and incandescent lighting fixtures to meet the designed lighting level and calculates unit power density, which translates the demanded amount of lighting energy.

A Study on Developing a Teardrop LED Lighting Fixture and Economic Analysis at Industrial Clean Rooms (산업용 클린룸에서의 Teardrop LED 등기구 개발 및 경제성 분석에 관한 연구)

  • Lhee, Sang Choon;Choi, Yeo Jin;Choi, Young Joon
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.63-68
    • /
    • 2013
  • On the electricity consumption in Korea, the lighting sector takes about 17% of annual total electricity consumptions. In the midst of higher interests on energy conservation measures, design and choice of energy-saving lighting fixtures have been more important. With growth of technology-intensive industries like advanced material, semiconductor, and biotechnology from the 1980s, needs for clean room and thus illumination at clean rooms have been increased. In this paper, development, specification, and features of a Teardrop LED(hereinafter TD LED) lighting fixture as replacement of Teardrop florescent lighting one that has been popularly installed at clean rooms were presented. Also we performed the economic analysis of return on investment(ROI) about energy savings by the installation of the TD LED lighting fixture at a new-built clean room. The economic analysis showed that the new-developed TD LED lighting fixture would be able to withdraw the initial installation cost within 4 years. Lastly, improvement directions and development plans of the next TD LED lighting fixture for wider applications at clean rooms were described.

Analysis of Energy Consumption and Research on Energy Saving of Lighting and Coo1ing Energy of a Superstore (대형마트의 조명 및 냉방 에너지 분석 및 에너지 절감 연구)

  • Bae, Chang-Hwan;Kim, Young-Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.342-348
    • /
    • 2011
  • This study analyzes the current and after retrofit energy consumption of lighting and cooling system of a superstore in Seoul. Energy consumption data were measured and collected with a measurement system. Annual energy consumption was calculated using TRNSYS program. After replacing lighting and chiller with higher efficiencies, annual TOE consumption decreased from 1,066 before retrofit to 832 after retrofit, saving 234 TOE (22%) in total. Similarly, total annual $TCO_2$ consumption decreased from 2,214 to 1,721, reducing 493 $TCO_2$ (22%) during this pilot study.