• Title/Summary/Keyword: ligament efficiency

Search Result 19, Processing Time 0.116 seconds

Modal characteristics of partially perforated rectangular plate with triangular penetration pattern

  • Jhung, Myung J.;Jeong, Kyeong H.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.3
    • /
    • pp.583-603
    • /
    • 2015
  • There are so many applications of perforated pates with various penetration patterns. If they are penetrated regularly, it can be represented by solid plate with equivalent material properties, which has a benefit of finite element modelling and reducing computation time for the analysis. Because the equivalent material properties suggested already are not proper to be applicable for the dynamic analysis, it is necessary to extract the equivalent material properties for the dynamic analysis. Therefore, in this study, the equivalent modulus of elasticity are obtained for the perforated plate with a triangular penetration pattern by comparing the natural frequencies of the perforated plate with those of solid plate, which are represented with respect to the ligament efficacy. Using the equivalent material properties suggested, the modal analyses of the partially perforated rectangular plate with a triangular penetration pattern are performed and its applicability is shown by comparing natural frequencies of perforated and homogeneous solid plates from finite element method and analytical method.

Development of the Rotary Electrostatic Painting Equipment Using Air Turbine (공기 터빈을 이용한 회전형 정전 도장기기의 개발)

  • Lee, Chan;Cha, Sang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.684-690
    • /
    • 2003
  • A new electrostatic rotary atomizing painting equipment using air turbine was developed. Based on the overall design requirements of painting equipment basic design specifications of the equipment parts such as air turbine and atomizing disk are defined from the present conceptual design model. Air turbine is designed with the section profile of NACA airfoil, and its internal flow field is analyzed by commercial CFD code. Atomizing disk is designed to achieve the ligament type spray of paint with the use of visualization technique. Various experiments and tests are conducted to investigate the spray and the transfer characteristics of newly-designed painting equipment, and the measurement results are compared with the those of conventional painting equipments.

  • PDF

Assessment of Equivalent Elastic Modulus of Perforated Spherical Plates

  • JUMA, Collins;NAMGUNG, Ihn
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.8-17
    • /
    • 2019
  • Perforated plates are used for the steam generator tube-sheet and the Reactor Vessel Closure Head in the Nuclear Power Plant. The ASME code, Section III Appendix A-8000, addresses the analysis of perforated plates, however, this analysis is only limited to the flat plate with a triangular perforation pattern. Based on the concept of the effective elastic constants, simulation of flat and spherical perforated plates and their equivalent solid plates were carried out using Finite Element Analysis (FEA). The isotropic material properties of the perforated plate were replaced with anisotropic material properties of the equivalent solid plate and subjected to the same loading conditions. The generated curves of effective elastic constants vs ligament efficiency for the flat perforated plate were in agreement with the design curve provided by ASME code. With this result, a plate with spherical curvature having perforations can be conveniently analyzed with equivalent elastic modulus and equivalent Poisson's ratio.

Free Vibration Analysis of Perforated Shell Submerged in Fluid (유체에 잠긴 다공 원통형 쉘의 자유진동해석)

  • Jhung Myung-Jo;Jo Jong-Chull
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.247-258
    • /
    • 2006
  • For the perforated cylindrical shell submerged in fluid, it is almost impossible to develop a finite element model due to the necessity of the fine meshing of the shell and the fluid at the same time. This necessitates the use of solid shell with equivalent material properties. Unfortunately the effective elastic constants are not found in any references even though the ASME code is suggesting those for perforated plate. Therefore in this study the equivalent material properties of perforated shell are suggested by performing several finite element analyses with respect to the ligament efficiencies.

Spray Characteristics on the Electrostatic Rotating Bell Applicator

  • Im, Kyoung-Su;Lai, Ming-Chia;Yoon, Suck-Ju
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2053-2065
    • /
    • 2003
  • The current trend in automotive finishing industry is to use more electrostatic rotating bell (ESRB) need space to their higher transfer efficiency. The flow physics related with the transfer efficiency is strongly influenced by operating parameters. In order to improve their high transfer efficiency without compromising the coating quality, a better understanding is necessary to the ESRB application of metallic basecoat painting for the automobile exterior. This paper presents the results from experimental investigation of the ESRB spray to apply water-borne painting. The visualization, the droplet size, and velocity measurements of the spray flow were conducted under the operating conditions such as liquid flow rate, shaping airflow rate, bell rotational speed, and electrostatic voltage setting. The optical techniques used in here were a microscopic and light sheet visualization by a copper vapor laser, and a phase Doppler particle analyzer (PDPA) system. Water was used as paint surrogate for simplicity. The results show that the bell rotating speed is the most important influencing parameter for atomization processes. Liquid flow rate and shaping airflow rate significantly influence the spray structure. Based on the microscopic visualization, the atomization process occurs in ligament breakup mode, which is one of three atomization modes in rotating atomizer. In the spray transport zone, droplets tend to distribute according to size with the larger drops on the outer periphery of spray. In addition, the results of present study provide detailed information on the paint spray structure and transfer processes.

Development of Pocket Insertion style Magnetic Curer that Apply $2^{loop}\;3^{pulsed}$ Variable Magnetic type Probe for Urinary Treatment

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Result that study magnet nerve curer for treatment induced current generation and current of ion for development in main point incontinence, prostate, sphincter, nervous system, rigidity, headache, retrogression arthritis, ligament damage, Rheumatism arthritis, peripheral nerve etc., can classify by 4. Embodied do first, full bridge magnet occurrence chapter, and communication with PC is available, confirmed various action loops an experiment. Could confirm correct treatment probe second, woman and man disease person. Third, derived so that healing may be possible naturally by addition of apron form according to disease. Because composition of finally, treatment probe composes by act of negative plate form, manufacture is easy and cooling designed for easy direction. More superior result of cooling appeared than existing in incidental and ingredients, cooling efficiency, composition, complexity, convenience etc. that expense and composition manufacture very straightforwardly and experimental by 2 - Tank ways.

Discussion of Neurologic Factor Influencing on Chewing Ability of Implant (임플란트 저작능에 영향을 주는 신경학적 원인에 대한 고찰)

  • Kim, Tae-Seon;Yoon, Jun-Ho;Kim, Sung-Hoi;Kim, Jee-Hwan;Shim, June-Sung;Lee, Jae-Hoon;Moon, Hong-Suk;Park, Young-Bum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • Many researches have been published about the numerous factors related to the chewing ability of implant prosthesis. Most respective studies have concluded that the chewing ability of implant prosthesis is mostly fine compared to other type of prosthesis. However, some patients are not satisfied with their chewing ability of implant prosthesis. Therefore the neurologic factor, one of the factors related to dissatisfaction of chewing ability was reviewed in this study to understand the mechanism of action of mastication. Data was searched using the keywords; 'implant chewing ability, masticatory ability' in Pubmed database and reviewed. Definitions of chewing ability, factors of chewing ability are reviewed and the neurologic factor, one of the factors influencing on chewing ability, is reviewed. Mechanoreceptor of Periodontal ligament(PDL) is providing the mastication information to brainstem. Due to the absence of mechanoreceptions of PDL in implant, masticatory ability is decreased especially when chewing hard food. Masticatory muscles and mechanoreceptor in TMD may compensate the lack of mechanoreceptor of PDL in implants. Furthermore sensitivity of nerve fiber around peri-implant tissues may support the mechanoreception and sensory reaction in the implant mastication. However, further studies should be conducted to prove the relationships between neurologic factors and mastication.

Osteogenic activity of an adenovirus expressing BMP-2 on Human Periodontal Ligament cells (Adenovirus에 의해서 발현된 BMP-2가 치주인대세포의 분화에 미치는 영향)

  • Kim, Kyoung-Hwa;Park, Yoon-Jeong;Lee, Sang-Cheul;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Han, Soo-Boo;Chung, Chong-Pyoung;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.511-524
    • /
    • 2005
  • The regeneration of lost periodontal tissue is a major goal of therapy. Periodontal ligament cell(PDL) is a specialized connective tissue that connects cementum and alveolar bone to maintain and support teeth in situ and preserve tissue homoeostasis. Bone morphogenetic proteins(BMPs) have shown much potential in the reconstruction of the periodontum by stimulate new bone and new cementum formation. Limitiations of BMP administration to periodontal lesions is high dose delivery, BMP transient biological activity, and low bioavailability of factors at the wound site. Gene delivery method can be alternative treatment strategy to deliver BMPs to periodontal tissue. The purpose of this study is to investigate efficiency of BMP-2 gene delivery with cell-based therapy using PDL cells. PDL cell were transduced with adenoviruses encoding either BMP-2 or Lac-Z gene. To evaluate osteogenic activity of expressed BMP-2 on PDL cells, we investigated secreted BMP-2, cellular activity, ALPase, produced mineralized nodules. To evaluate collagen scaffold as carrier for transduced cell delivery, we examined morphology and secreted BMP-2 of transducd PDL cells on it. BMP-2 transducd PDL cells produced higher levels of BMP-2, ALPase, mineralized nodules than non transduced cells. Cellular activity of transduced cells was showed similar activity to non transduced cells. Transduce cells attached on collagen scaffold secreted BMP-2 at 7day and was showed similar morphology to non transduced cells. These results demonstrated that transduced PDL cells produced biologically active BMP-2 and collagen scaffold could be carrier of transducd cells.

Finite-element investigation of the center of resistance of the maxillary dentition (상악 치아군의 저항중심의 위치에 관한 3차원 유한요소 해석)

  • Jeong, Gwang-Mo;Sung, Sang-Jin;Lee, Kee-Joon;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.83-94
    • /
    • 2009
  • Objective: The aim of this study was to investigate the 3-dimensional position of the center of resistance of the 4 maxillary anterior teeth, 6 maxillary anterior teeth, and the full maxillary dentition using 3-dimensional finite element analysis. Methods: Finite element models included the whole upper dentition, periodontal ligament, and alveolar bone. The crowns of the teeth in each group were fixed with buccal and lingual arch wires and lingual splint wires to minimize individual tooth movement and to evenly disperse the forces to the teeth. A force of 100 g or 200 g was applied to the wire beam extended from the incisal edge of the upper central incisor, and displacement of teeth was evaluated. The center of resistance was defined as the point where the applied force induced parallel movement. Results: The results of study showed that the center of resistance of the 4 maxillary anterior teeth group, the 6 maxillary anterior teeth group, and the full maxillary dentition group were at 13.5 mm apical and 12.0 mm posterior, 13.5 mm apical and 14.0 mm posterior, and 11.0 mm apical and 26.5 mm posterior to the incisal edge of the upper central incisor, respectively. Conclusions: It is thought that the results from this finite element models will improve the efficiency of orthodontic treatment.