Young Children's 'More Means More' Bias and Knowledge Change Process Regarding a Lever Phenomenon (지렛대 현상에 대한 유아의 '많은 것이 더 많은' 편향과 지식 변화 과정)

  • Kim, He Ra
    • Korean Journal of Childcare and Education
    • /
    • v.9 no.2
    • /
    • pp.117-141
    • /
    • 2013
  • The purpose of this study is to investigate the young children's 'more means more' bias and knowledge change process regarding a lever phenomenon, especially the relationship between the weight of an object and the strength of force and between the length of a lever and the strength of force. Subjects, who were presented with the tasks, were eight young children 5 years of age. Major findings were as followings. First, most of the subjects have a 'more means more' bias about the relationship between the weight of an object and the strength of force and between the length of a lever and the strength of force regarding a lever phenomenon. This meant that young children have similar concepts about a lever phenomenon regardless of whether it is right or wrong physically. Second, young children tried to make sure of their knowledge during experiments. They chose the evidence which confirmed their knowledge. But they tried to change their knowledge, when the evidence presented did not correspond to their knowledge. These findings contribute to understanding young children's 'more means more' bias and knowledge change process about a lever phenomenon and can be used in preschool science education programs and curriculums.

Improvement for Response Delays of Displacement Magnifier in Jetting Dispenser (젯팅 디스펜서 변위확대장치의 응답지연 개선 연구)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;Hong, Seung-Min;Lee, Chul-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.546-551
    • /
    • 2016
  • The objective of this study is to investigate the response delays between piezo-stack actuator and the displacement magnifier of jetting dispenser and to reduce its falling time in terms of displacement optimization. The dispenser is driven by the dual piezo-stack actuators with a hinge lever mechanism to precisely control flow rate of the working fluid (3000 cP). It is commonly found that piezo actuator-driven jetting dispensers involving viscous working fluids have displacement optimization problem for ideal performance. The response delay of the system is caused by the phenomenon that the displacement magnifier cannot exactly follow the motion of the piezo actuators. The response delay may lower the performance of the system due to the inaccurate discharge of working fluid or even damages to the system itself due to inharmonious motion of piezo actuators with lever system. To reduce its response delay, a new displacement profile obtained from displacement optimization is suggested; its performance is tested through finite element analysis; and experiments are carried out to verify the performance of the obtained displacement profile.

Analysis of the Phenomenon of Integrated Consciousness as a Global Scientific Issue

  • Semenkova, Svetlana Nikolaevna;Goncharenko, Olga Nikolaevna;Galanov, Alexandr Eduardovich
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.7
    • /
    • pp.359-365
    • /
    • 2022
  • Scholars are paying increasingly close attention to brain research and the creation of biological neural networks, artificial neural networks, artificial intelligence, neurochips, brain-computer interfaces, prostheses, new research instruments and methods, methods of treatment, as well as the prevention of neurodegenerative diseases based on these data. The authors of the study propose their hypothesis on the understanding of the phenomenon of consciousness that answers questions concerning the criteria of consciousness, its localization, and principles of operation. In the study of the hard problem of consciousness, the philosophical and scientific categories of consciousness, and prominent hypotheses and theories of consciousness, the authors distinguish "the area of the conscious mind", which encompasses several states of consciousness united by the phenomenon of integrated consciousness. According to the authors, consciousness is a kind of executor of the phenomenological idea of the "chalice", so the search for it should be conducted deeper than the processes in the power of thought consciousness and transconsciousness, to which integrated consciousness can act as a lever. However, integrated consciousness may have the capacity to transcend into lower states of consciousness, which requires further study.

Dynamic Behavior of Vacuum Circuit Breaker with Permanent Magnetic Actuator (영구자석형 조작기를 갖는 진공차단기의 동적거동)

  • Yu, Lyun;Kim, Young-Geun;Lee, Sung-Ho;Cho, Hae-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.5
    • /
    • pp.578-585
    • /
    • 2007
  • A vacuum circuit breaker (VCB) with permanent magnet actuator (PMA) has been studied in this study. Electromagnetic field analysis and dynamic simulations have been carried out for optimal design of VCB by using commercial software Maxwell and ADAMS. This simulation model can be an effective method for the VCB, which has non-linear output force of PMA, friction, and impact for operations. An experiment has been conducted to evaluate correctness of the simulated model. By using this evaluated model, the displacement and velocity characteristics of the VCB have been simulated with following conditions : (1) The different output forces of PMA have been applied, (2) The friction conditions in follow lever shaft and moving part have been changed, (3) The mass conditions of moving part have been changed. The simulated results shows that the velocity characteristics are mainly determined by the output force of PMA. The effects due to the changes of friction conditions against the dynamic characteristics was small, and the mass conditions of the moving parts affect the velocity and a bouncing phenomenon of VCB. From these results, the optimal design conditions for the VCB have been derived.

Development of Force Measuring Device in Learning Wind Tunnel Used for Transportation Technology Class (수송 기술에 적합한 학습용 풍동의 힘 측정 장치 개발)

  • Choi, Jun-Seop;Lee, Sung-Gu
    • 대한공업교육학회지
    • /
    • v.32 no.1
    • /
    • pp.117-133
    • /
    • 2007
  • The purpose of this study was to develop the force measuring device of learning wind tunnel, teaching-learning materials in order to enhance understanding of flight principle and give interest about aviation technology in secondary school. The content of this study was consisted of the development and experiment of force measuring device for learning wind tunnel. The main results of this study were as follows: This device developed here is simple structure applying lever principle instead of the comparatively expensive load cell used in engineering college or a aviation research institute and so on. Measurement of lift and drag as well as the comparison experiment of a fluid resistance is possible with only one device developed here. The lift coefficient with angle of attack has shown the same tendency in both of theoretical and experimental values. And the stall phenomenon was found under the larger angle of attack of experimental rather than expected theoretical values. The drag coefficient with angle of attack has shown the same tendency in both of theoretical and experimental values. And drag coefficient the rate of increasement of the experimental values increased more gently than its theoretical values.

Creep Behaviours of 9% Ni Alloy (Ni 합금강의 크리프 거동)

  • Hwang, Kyung-Choong;Kim, Jong-Bae;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.89-94
    • /
    • 2008
  • Purpose: To observe the high temperature creep test and the fracture surface of the samples of 9% Ni alloy steel generally used for all kinds of mahine parts and predict the durability of that by determining a constant of C with a Larson-Miller variable. Methods: The equipment of this test was made into lever-beam style designed by Andrade and F. Garofalo et al.. The condition of creep test was set under 16 kinds of conditions after fixing 4 kinds of temperature condition and 4 kinds of stress condition to check how it effects the samples. Results: The temperature of creep test was increased, the stress index (n) of creep deformation was gradually decreased from 3.97 to 3.55. The activation energy of creep deformation was decreased from 90.39 to 83.64 kcal/mol when the stress was increased. A constant of C value by calculation of larson-Miller variable was about 22 and if temperature for use is suggested, the durability could be calculated. Conclusions: By analyzing the fracture phenomenon and suggesting the observation result of the fracture surface of the samples and creep test of 9% Ni alloy steel, the basic design data for the practical use of accessories in the field of equipment could be constructed and used to predict the durability of the equipment.

  • PDF

A Study on The New Conceptual Faucet Design to Which Flow-meter is attached (유량 측정기기 부착 수전금구 디자인에 관한 연구)

  • 박성룡
    • Archives of design research
    • /
    • v.17 no.2
    • /
    • pp.351-362
    • /
    • 2004
  • Generally, they respond to a phenomenon, with their any way, which they have looked at in their surroundings, and also put into their action successively and variously according as what it is. A person who has not so much problems in experiential education added to mental and physical ability prefers controlling his manner by himself as seeing, listening and feeling to being cured it by other physical support. Meanwhile, even though there are tools that we use conveniently in everyday life, it is sometimes required that user is able to control his action by himself with a certain interactive function to deal with a accidental situation. For example, in the home, when they were cooking, washing dishes and taking a bath they would not often control their minds on how to act about flowing water through the faucet going back and forth between saving and easygoing. By reasons of those statements, the project has been studied to propose the new conceptual faucet which digital technology is applied to, for recognizing the volume of water flowed through water pipe as counting it with built-in flow meter, and then saving water as controling the water-flow with faucet lever. It means that homemakers can observe the flow rate of water from the faucet placed in front of the sink in kitchen and control it right away for saving water. For studying this project, the kinds and features of the various flow-meters that measure the volume of water-flow were researched and analyzed for taking a reasonable type to the new ideal faucet. According to this analyzing, turbine-flow-meter was selected as appropriate form for the digital display-built-in faucet that would be presented in this project. As the next step, the basic structure was created for developing a new conceptual faucet. Finally two models have been presented through several steps for making the suitable shape to the new style faucet.

  • PDF

FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY OVERDENTURES (Overdenture 하에서 하악응력 및 의치의 변위에 관한 유한요소법적 분석)

  • Kim, Joung-Hee;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.63-94
    • /
    • 1990
  • The purpose of this study was to analyze the displacement and the magnitude and the mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment tooth and the mandibular supporting bone when various denture base materials, such as acrylic resin and 0.5mm metal base, and various denture base designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. Mandibular arch models, with only canine remaining, were fabricated. In the first denture base design, a space, approximately 1mm thick, was prepared between the denture and the dome abutment. In the second denture base design, contact between the denture and the dome abutment was eliminated except the contact of the occlusal third of the abutment. In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle region, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 kgs on the first molar region(P1) and 7 kgs on the central incisal region (P2) in a vertical direction. Then the force of 10 kgs was applied distributively from the first premolar to the second molar of each model in a vertical direction(P3). The results were as follows. : 1. When the testing vertical loads were given to the selected points of the overdenture, the overdenture showed the rotatory phenomenon, as well as sinking and the displacements of alveolar ridge, abutment and lower border of mandible under the metal base overdenture were less than those under the acrylic resin overdenture. 2. The maximum principal stresses(the maximum tensile stresses) being considered, high tensile stresses occured at the buccal shelf area, the posterior region of the ridge crest and the anterior border region of the mandibular ramus. 3. The minimum principal stresses(the maximum compressive stresses) being considered, high compressive stresses occured at the inferior and posterior border region of the mandible, the mandibular angle and the posterior border region of the mandibular ramus. 4. The vertical load on the central incisal region(P2) produced higher equivalent stress in the mandible than that on any other region(P1, P3) because of the long lever arm distance from the fixed points to the loading point. 5. Higher equivalent stresses were distributed throughout the metal base overdenture than the resin base overdenture under the same loading condition. 6. The case of occlusal third contact of the abutment to the denture produced higher equivalent stresses in the abutment, the mandibular area around the abutment and the overdenture than the case of a 1mm space between the denture and the abutment. 7. Without regard to overdenture base materials and designs, the amounts and distribution patterns of equivalent stresses under the same loading condition were similar in the mucous membrane.

  • PDF