• Title/Summary/Keyword: level meter

Search Result 484, Processing Time 0.032 seconds

Mathematical Model Expression of Portable Calibration System for Float Type Water Level Meters (부자식 수위계를 위한 이동형 교정시스템의 수학 모델)

  • Hong, Sung-taek;Shin, Gang-wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1964-1972
    • /
    • 2017
  • K-water have been operating as an International accredited calibration organization for ISO 17025 regarding float, ultrasonic and radar type since 2008. Due to the absence of on-site calibration system, water level meter could only be calibrated from a laboratory. Therefore K-water institute developed an mobile calibration system for water-level meter in 2015 to calibrate the water-level meter on site. The mobile calibration system was certificated by KOLAS(Korea Laboratory Accreditation Scheme) in 2016. In this paper a mobile calibration system, which is a method to calibrate float type water level meter on site, is established. A mathematical equation was derived by reviewing characteristics of standard equipment and measurement. By developing the mobile calibration system, it is possible to achieve reliability of data through scientific system operation on hydrological data.

Measurement of Environmental Radiation according to Altitude above Sea Level in National Park (국립공원의 해발고도에 따른 환경방사선 측정)

  • Ji, Tae-Jeong;Lee, In-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.694-701
    • /
    • 2012
  • This study set put to measure the environmental radiation for mountainous regions of National Parks where Integrated Environmental Radiation Monitoring Network is not installed. For the measurement method, the space dose was classified at 1 meter high from the surface and the index dose at the surface. The measured radiation energy measured gamma, alpha and beta rays. For selection of national parks, we selected 10 national parks which are within the same distribution in the southern part and central part of the nation. For measurement equipment, INTERCEPTOR$^{TM}$(Thermo, USA, 2006) was used for gamma rays. As for the results of the measurements, for the space gamma dose, a high level was measured at a sea level of 500 meter in national parks with an altitude of less than 1,000 meter. It was found that the value was more than $0.23{\mu}Svh^{-1}$ especially in Bukhan Mountain, Gyeryong Mountain and Wolchul Mountain. In national parks with an altitude of more than 1,000 meter, $1.77{\mu}Svh^{-1}$ was measured at 1,500 meter at Seorak Mountain. Therefore, this is 10 times greater than the background standard dose. The national parks were there were no significant changes in dose were Naejang Mountain, Sobaek and Jiri Mountains. For the measurement of the index dose, a high dose level was measured at middle altitudes of 500 meter and 1,000 meter. For measurement according to the composition types of crust, high doses were recorded at national parks composed of rocks and a lower environmental radiation level was measured at Hanra Mountain where volcanic activities have occurred.

Performance evaluation of 80 GHz FMCW Radar for level measurement of cryogenic fluid

  • Mun, J.M.;Lee, J.H.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.56-60
    • /
    • 2021
  • The microwave Radar used for special purposes in the past is being applied in various areas due to the technological advancement and cost reduction, and is particularly applied to autonomous driving in the automobile field. The FMCW (Frequency Modulated Continuous Wave) Radar can acquire level information of liquid in vessel based on the beat frequency obtained by continuously transmitting and receiving signals by modulating the frequency over time. However, for cryogenic fluids with small impedance differences between liquid medium and gas medium, such as liquid nitrogen and liquid hydrogen, it is difficult to apply a typical Radar-based level meter. In this study, we develop an 80 GHz FMCW Radar for level measurement of cryogenic fluids with small impedance differences between media and analyze its characteristics. Here, because of the low intrinsic impedance difference, most of the transmitted signal passes through the liquid nitrogen interface and is reflected at the bottom of the vessel. To solve this problem, a radar measurement algorithm was designed to detect multiple targets and separate the distance signal to the bottom of the vessel in order to estimate the precise position on the liquid nitrogen interface. Thereafter, performance verification experiments were performed according to the liquid nitrogen level using the developed radar level meter.

A Method on the Improvement of the Signal Processing Calculation Structure of the Remote Measurement Level Meter (원격 측정 레벨계의 신호처리 연산 구조 개선 방법)

  • Park, Dongkun;Lee, Kijun
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.389-400
    • /
    • 2019
  • Level meters are non-invasively capable of measuring the level of the medium, and a growing variety of level meters are being used in the industry in connection with safety and maintenance. The level meter can be measured according to various kinds of medium such as solid medium such as coal, flour, rice and liquid medium such as water and petroleum. In order to reduce the error depending on the medium, the measurement using the Doppler Effect can compensate the measurement error, However, the number of signal processing steps is increased, the operation speed is further increased, the hardware complexity increases, and a high cost structure is required. In this paper, we propose a method to improve the signal processing operation structure of the remote measurement level meter to reduce the amount of computation and the resource usage of the required FPGA.

Optimal design of dual magnetic float type level gauge to detect a specific level (특정 레벨을 검출하기 위한 2단 Magnetic Float 타입 레벨 게이지의 최적 설계에 관한 연구)

  • Kim, Dong-Sok;Han, Jae-Man;Park, Gwan-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.308-316
    • /
    • 2008
  • For the measurement of liquid level in ship's cargo tank, ballast tank, fuel oil tank and fresh water tank, several types of gauge meter are used such as tubular type, magnetic float type, reflex type transparent type and welding pad type. Among them, magnetic float type gauge meter is environmental friendly device because it is free of power source and maintenance. The main obstacle of the device is relatively large error bound. In this paper, finite element method is used to design and analysis of the magnetic float type gauge meter. The operation of reed switch according to the magnetic field has been successfully described and agreed well with experimental measurement. The optimum geometry with combination of permanent magnet and reed switches are designed to achieve 98 % accuracy of fluid level.

Development of Float Water Level Meter Portable Calibration System (부자식 수위계 이동형 교정시스템 개발)

  • Hong, Sung-taek;Kim, Il-han;Choi, Jong-woong;Shin, Gang-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.411-414
    • /
    • 2016
  • K-water institute is a calibration and test institute accredited by international standard calibration center for water-level meters. Due to the absence of on-site calibration system and procedure for Float Water Level Meter, the calibration was performed only in the standard calibration laboratory. In this study, mobile calibration system and procedure were developed to calibrate Float Water Level Meter on site using scale bar and camera. It is possible to obtain reliable water-level data and achieve consistent data management.

  • PDF

On-line Measurement of Oil Consumption Using Oil Consumption Meter (오일소모 측정센서를 이용한 오일소모량의 실시간 측정)

  • 김기대;이재곤
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.688-694
    • /
    • 2002
  • Several methods were developed for on-line measuring oil consumption in gasoline engine using an oil consumption meter. The oil consumption meter indicates the oil quantity by real-time-measuring the oil level in the sump. In order to measure the oil consumption, the oil consumption meter proposed in this paper requires shorter time, less additional procedures, and shows better results than the traditional drain method. Under steady-state engine-operating conditions, the results obtained through the regression or the difference method show an good agreement with those through the drain method. Under transient engine-operating conditions, on the other hand, good results can be obtained through the reference method.

Development of a Microwave Level Meter Using YIG-VCO for Industrial Process (YIG-VCO를 사용한 산업용 마이크로파 거리계의 개발)

  • 김정목;임종수;전중창;김태수;안광호;이승학
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2000
  • In this paper, we have designed a microwave level meter based on the FM-CW radar theory using a YIG-tuned oscillator (YTO). YTO has an excellent frequency linearity, so a linearizer circuit is not necessary for the level meter. It is shown that interference signals reflected from nearby obstacles can be removed by using a digital band-pass filter. An FIR band-pass filter is designed using the Kaiser window. The distance measurement has been performed in the outdoor test field. The measurement data have been obtained for the range of 1~40m with 1m step, and the results show that the standard deviation of the measured data is 2.33 cm. The level meter manufactured in this study can be applied usefully in the industrial facilities which are not accessible easily, for example, to measure the level of molten metal in the iron and steel company.

  • PDF

A Study of an Application Scheme for Smart Meter and Value Added Services Based on Korean Environment (한국형 스마트 전력량계 부가서비스 적용방안 연구)

  • Kim, Seok-Gon;Lee, Han-Byul;Lee, Young-Joo;Choi, Yong-Sung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.106-111
    • /
    • 2010
  • Electronic watt hour meters(WHM) for high pressure running in domestic were installed to the digital type meter and ones for low pressure are expected to complete within several years. Domestic power metering technology is being beyond a simple framework with an electronic type and is rapidly evolving to intelligent smart metering systems in conjunction with promotion of a national smart grid project. Major policy outlook of the world's major power company regarding Intelligent metering is the application of the fare structure diversification and is the improvement of level of service to customers. In addition, electric power companies should focus on the cost reduction and the improvement of management efficiency through an efficient operation of distribution facility. In this paper, we are about to make an observation of the additional services technology development trend of the overseas smart meter and to have a view of value-added services(VAS) system of smart meter suitable for the domestic environment based on the technology development of VAS utilizing electronic watt hour meter performed by recent research projects.

Improved Design of the Microwave Level Meter upon VCO Nonlinearity (마이크로파 거리계의 VCO 비선형성에 의한 시스템 특성 분석 및 개선 방안 연구)

  • 전중창;김정목임종수
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.331-334
    • /
    • 1998
  • In this paper, we have presented an improved design of the microwave level meter based on the principle of FM-CW radar. First, we have analyzed the effect of VCO nonlinearity on the spectral broadening of the beat signal, and presented a new type of design theory to linearize VCO tuning curve adopting FFT algorithm. Simulation results for a VCO having the linearity of 25% have been presented, which show the usefulness of the design algorithm.

  • PDF