• Title/Summary/Keyword: level A,B,C,D

Search Result 862, Processing Time 0.033 seconds

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

The Effects of Dietary Vegetable Oils on the Blood Cholesterol Level of Rabbit (집 토끼의 Blood Cholesterol Level에 미치는 몇가지 식물성(植物性) 식용유(食用油)의 영향)

  • Nam, Hyun-Keun;Lee, Yong-Ock
    • Korean Journal of Food Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.77-81
    • /
    • 1980
  • The effect of dietary vegetable oils, sesame, perilla, soybean and rice bran oils, on the blood cholesterol level of rabbit was examined using isocaloric and isonitrogenous diets. The gain in body weight, liver weight, serum and liver cholesterol levels, globulin, blood sugar and acid phosphatase activity in relation to cholesterol level were studied. The results are summarized as follows : 1. The gain in body weight (g/day) of rabbit was 16.3 for control, 15.3 for A, 18.3 for 15.3 for A, 18.3 for B, 15.3 for C and 18.1 for D groups. 2. Liver weight of the control A, B, C and D groups were 30.35, 37.25, 38.25, 31.05 and 39.54, respectively. 3. Serum cholesterol levels (mg/100 ml serum) of the control, A, B, C, and D groups were 71.5, 112.0, 110, 93 and 96 respectively. 4. Liver cholesterol levels (mg/100 ml liver fat) of the control, A, B, C and D groups were 255, 292, 255, 317 and 195 respectively. 5. The contents of alpha-1-globulin for control was 0.60 %, for C, 0.35 % and for D groups, 0.32% of total globulin. The content of alpha-2-globulin for control was 0.68 % of total globulin and for D, 0.26 % of total globulin. 6. The contents of blood glucose (mg/100 ml) of the control, A, B, C and D groups were 40.34, 22.37, 77.0, 28.6 and 34.1 respectively. 7. Acid phosphatase of the control, A, B, C, and D groups were 3.95, 4.52, 3.98, 4.55 and 4.53 nM/hr/l serum respectively. 8. According to the regression and correlation in coefficient in blood components of rabbit, there were positive correlations between serum cholesterol and alpha-1-globulin, and between liver cholesterol and gamma-globulin.

  • PDF

Studies on the Establishment of Cultural Fractice for $\underline{Angelica\;tenuissima}$ NAKAI II. Influence of Planting Density and Fertilizer Level on Growth and Root Yield of $\underline{Angelica\;tenuissima}$ NAKAI (고본(Angelica tenuissima Nakai)의 재배법 확립에 관한 연구 II. 재식밀도와 시비량이 고본의 생육 및 수량에 미치는 영향)

  • Choi E. O.;Seo J. S.;Jeong B. C.;Kang C. W.;Huh B. L.
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 1990.05a
    • /
    • pp.118-119
    • /
    • 1990
  • PDF

A Single Transistor-Level Direct-Conversion Mixer for Low-Voltage Low-Power Multi-band Radios

  • Choi, Byoung-Gun;Hyun, Seok-Bong;Tak, Geum-Young;Lee, Hee-Tae;Park, Seong-Su;Park, Chul-Soon
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.579-584
    • /
    • 2005
  • A CMOS direct-conversion mixer with a single transistor-level topology is proposed in this paper. Since the single transistor-level topology needs smaller supply voltage than the conventional Gilbert-cell topology, the proposed mixer structure is suitable for a low power and highly integrated RF system-on-a-chip (SoC). The proposed direct-conversion mixer is designed for the multi-band ultra-wideband (UWB) system covering from 3 to 7 GHz. The conversion gain and input P1dB of the mixer are about 3 dB and -10 dBm, respectively, with multi-band RF signals. The mixer consumes 4.3 mA under a 1.8 V supply voltage.

  • PDF

A Study on Managing High-Speed Railway Links and Rolling Stocks Based on the Level of Service (서비스수준(LOS)을 감안한 고속철도 노선 및 차량관리방안)

  • Oh, Jae Kyoung;Kim, Si Gon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.1025-1032
    • /
    • 2017
  • In this paper, the level of service (LOS) is defined for high-speed railway links and rolling stocks. Based on this LOS, how to manage high-speed railway facility is also suggested. The LOS is divided into 6 levels from A to F. The measurement of effectiveness (MOE) for railway links is derived from the relationship between a total delay time and a railway link utilization ratio. Another MOE, volume over capacity (V/C), is also proposed. On the other hand, the LOS for high-speed railway rolling stocks is based on the density of people in a rolling stock. Above all, LOS D is defined to the total number of seats. Then, LOS A is 50% of the LOS D, LOS B is 70% of the LOS D, LOS C is 90% of the LOS D and LOS D~F is defined as the maximum seats and standing people at the level of each. Finally, a method to manage high-speed railway links and rolling stocks is proposed in order to keep the level of service at the target by the government.

IS-95C coupler for Optical repeater for Cell extension of IS-95A/B & IS-95C service (CDMA 통신용 IS-95A/B, IS-95C 서비스의 Cell 확대를 위한 광중계기 연결보조장치)

  • 정재성;김부곤;이용국
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.39-43
    • /
    • 2001
  • A system, IS-95C coupler that combines the signals of IS-95A/B and IS-95C BTS and compensates the differences between the signals of two systems and connected to optical repeater If no IS-95C coupler exist, Optical repeater can't service of signal balanced. A system carries on combination, amplification, level modulation function of the TX signals(IS-95A/B & IS-95C) and division and level modulation function of the RX signals. Isolation satisfied above 100dB.

  • PDF

Innovation and Industrial Concentration (R&D 지출과 경제적 성과에 관한 실증분석 - 16개 광역지역을 대상으로 -)

  • Lee, Dong-Soo;Cho, Taek-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.3
    • /
    • pp.184-193
    • /
    • 2021
  • This paper investigates the performance of technology innovation activities performed by firms in 16 major regions in Korea using 2002-2010 survey data by STEPI. The theoretical and empirical analysis is carried out via the 2 models which are the simple R&D - total revenue model and Cobb-Douglas model based on the simple model adding labor variable. The main results shows that for simple model, the R&D elasticity for total revenue is 0.42 for all areas and Ul-San shows the highest elasticity level, 0.66 and Bu-San the lowest level, 0.2. In case of Cobb Douglas model the R&D elasticities are not statistically significant for many regions. To overcome the low statistical significance, we grouped the 15 regions for 3 wider regions using ANOVA based on the R&D intensity for the homogeneity of R&D activities. By grouping, each region has more observations to analyze and the results from the empirical analysis shows higher statistical significance level and data explanation capability. In this case, Group 3 which shows larger firm size and slightly higher export share shows the highest level of R&D elasticity, 0.088 and Group 1 which has the smallest firm size and the lowest revenue growth rate shows the lowest level, 0.31. For the labor elasticity, Group 1 shows the higest level, 1.16 and Group2 the lowest level, 1.096. These results show that the regions which have many middle and small firms reveal low R&D-revenue elasticity and high labor-revenue elasticity.

Intercomparisons of ADEOS/IMG Measurements with the Sonde Observations over Korea (한반도 상공의 ADEOS/IMG 관측 자료와 존데 자료의 비교 분석)

  • 조하만;김주공;오성남
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.3
    • /
    • pp.253-266
    • /
    • 1999
  • ADEOS(Advanced Earth Observing Satellite)/IMG(Interferometric Monitor for Greenhouse Gases) measurements - temperature, water vapor($H_2O$), ozone($O_3$) have been compared with the radio sonde and ozone sonde observations at Osan and Pohang stations for the 4 cases on 10 Jan.(a), 28 Jan.(b), 2 Apr.(c), and 19 Jun.(d) 1997 to detect the error ranges of the IMG data. It showed that the IMG data of the cases (b), (d) when the ADEOS passed over the central part of Korea were quite stable with the good agreement with the sonde observations, however, that of (a),(c) when the ADEOS passed over south- east coastal area were unstable with the larger differences from the sonde-observations. The RMSE and bias analyses of temperature for the stable cases (b),(d) showed that the differences between the IMG data and the sonde observations were about 1~4 K at the 700~300 hPa level and about 4~5 K or more at the higher level, and the IMG measurements tended to be larger than the sonde observations at the higher level above 200 hPa, while no typical bias was seen at the lower level. The RMSE and bias analysis for the version of level 2 5_6_4_4 of ozone showed that the RMSE of ozone were quite small, in general, except at the higher level above 50~60 hPa in the all 4 cases, however the bias was generally big with the positive value in the troposphere and the negative in the stratosphere. An example of vertical profile of trace gases such as $CO_2, N_2O, CH_4, HNO_3$, CO measured by IMG was also presented and it showed that the IMG data had large differences between the 5 different observation points.

Perfonnance Analysis of the Combined AMC-MIMO Systems with MCS Level Selection Method (MCS 레벨 선택 방식에 따른 AMC-MIMO 결합 시스템의 성능 비교)

  • Hwang In-Tae;Kang Min-Goo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.665-671
    • /
    • 2006
  • In this paper, we propose and observe a system that adopts Independent-MCS (Modulation and Coding Scheme) level for each layer in the combined AMC-V-BLAST (Adaptive Modulation and Coding-Vertical-Bell-lab Layered Space-Time) system. Also, comparing with the combined system using Common-MCS level, we observe throughput performance improvement. As a result of simulation, Independent-MCS level case adapts modulation and coding scheme for maximum throughput to each channel condition in separate layer, resulting in improved throughput compared to Common-MCS level case. Especially, the results show that the combined AMC-V-BLAST system with Independent-MCS level achieves a gain of 700kbps in $7dB{\sim}9dB$ SNR (Signal-to-Noise Ratio) range.

A Study on the Airborne Noise of the Small Fishing Boats (소형어선의 소음에 관한 연구)

  • Yang, Yong-Su;Jung, Kong-Heun;Seo, Du-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.4
    • /
    • pp.412-417
    • /
    • 1992
  • In full-speed cruising, the airborne sound pressure levels are measured from 11 small fishing boats operated around Cheju Island. In these measurement, 9 measuring positions are selected in each fishing boats. The results of measurements and analyses are as follows: 1. The sound pressure levels in FRP boats are higher than those in wooden boats. 2. The highest sound pressure level is 112dB(A) at the engine room in C boat, while the lowest one is 72dB(A) at the front deck in K boat. 3. The highest sound pressure level is shown to be in the frequency band less than 500Hz. 4. The highest sound pressure level is shown to be in the frequency band less than 500Hz. 5. Through all 9 positions, the sound pressure levels are higher in B and C boat and lower in E and K boats.

  • PDF