A Thermal Flow Analysis for an Optimal shape of Solar Lamp Bank (최적의 램프뱅크형태를 결정하기 위한 열유동 해석)

  • Baek, Sang-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.82-89
    • /
    • 2012
  • This study is on the thermal flow analysis to select an optimal shape of solar lamp bank. Solar Lamp bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. Among the 4 kinds of lamp bank, since lamp bank type D satisfies uniformity ${\pm}10%$ and also doesn't exceed total irradiance 1,232 $W/m^2$, type D is finally selected.

A Study of the Visual Evaluation by Variation in the Line and Length of the Bolero (볼레로 라인과 길이 변화(變化)에 따른 시각적 평가(視覺的 評價))

  • Lee, Jung-Soon;Kim, Jeong-Mee
    • Journal of Fashion Business
    • /
    • v.10 no.5
    • /
    • pp.122-134
    • /
    • 2006
  • The purpose of this study was to evaluate the visual effects and images according to changes in the line and length of the connecting lines of the neck, center front, and hem line from analyzing the bolero style shown in 2005 S/S domestic fashion. The basic lines of the bolero were classified into three different categories according to the connecting lines of the neck, center front line, and hem line. We altered the length of the bolero in three categories with changes in the waistline-5cm, waistline-8cm, and waistline-11cm. For the visual evaluation, 9 stimuli were placed in mannequins, and were estimated by the experts in the fashion design. For the visual evaluation according to changes in the line and length of the bolero, we used 12 pairs of items to find the visual effects, and 13 pairs of adjectives to measure the visual images. The stimuli and adjectives were randomly given to the evaluators and were evaluated by the 7-Point Likert Type Scale. The data have analyzed by frequency, factor analysis, anova, scheffe's test. According to the result of factor analysis of the visual effects of the Bolero, the result was classified into 4 factors: the whole silhouette, neck line, breasts and shoulders. According to the result of factor analysis of the visual image of the Bolero, the result was classified into 3 factor: maturity, tenderness, neatness. The visual effects by variations in the line and length of the bolero had significant differences in all factors. The visual images by variations in the line and length of the bolero had significant differences in the maturity, tenderness, but they didn't show significant differences in neatness.

Spray Characteristics of Swirl-coaxial Injector According to the Recess Length and Injection Pressure Variation (리세스 길이 및 분사압력 변이에 따른 스월 동축형 인젝터의 분무특성)

  • Bae, Seong Hun;Kwon, Oh Chae;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.68-76
    • /
    • 2016
  • This research is carried out for the performance evaluation of the injector that is one of the critical components of bipropellant-rocket-engine. Spray characteristics are investigated in detail according to the recess length and injection pressure on the swirl-coaxial-injector using gaseous methane and liquid oxygen as propellants. A visualization is conducted by the Schlieren photography that is composed of a light source, concave mirrors, knife, and high-speed-camera. A hollow-cone-shape is identified in the liquid spray that is spread only by inner injector and the spray angle is decreased due to the diminution of swirl strength in accordance with the increase of the length of injector orifice. When the injector sprays the liquid through the inner injector with the aid of gas through the outer injector, the spray angle in external mixing region tends to increase with rise of the recess length, while in internal mixing region, it is decreased. It is also confirmed that the same tendency of the spray angle with recess length appears irrespective of the injection pressure of liquid spray.

Evaluation on compressive strength of steel-concrete composite piles using a large scaled UTM(Universal Test Machine) (대형 UTM을 이용한 강관합성 말뚝재료의 강도 특성 평가)

  • Lee, Ju-Hyung;Kwon, Hyung-Min;Park, Jae-Hyun;Kwak, Ki-Seok;Chung, Moon-Kyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.482-489
    • /
    • 2009
  • Various model piles with different sections such as reinforced concrete, steel, steel-concrete composite without rebar and steel-concrete composite with rebar were made, and vertical load test was conducted using a large scaled UTM(Universal Test Machine) to evaluate Young's modulus and ultimate load of the model piles. Based on the tests, ultimate load of steel-concrete composite pile is 31% greater than the sum of it of reinforced concrete pile and it of steel pile. This is caused that ultimate load and Young's modulus of inner concrete increase due to confining effect by outer steel casing. Variation of ultimate load is also insignificant depending on the ratio of length to diameter(L/D), therefore bucking has not an effect on change of ultimate load in case of the L/D below 10.

  • PDF

Seismic Curvature Ductility of RC Bridge Piers with 2.5 Aspect Ratio (형상비 2.5의 RC 교각의 내진 곡률연성도)

  • Chung, Young-Soo;Park, Chang-Kyu;Lee, Eun-Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.1-12
    • /
    • 2004
  • Due to the 1989 Loma Prieta, 1995 Hyogoken Nambu earthquakes, etc, a number of bridge columns  were collapsed in flexure-shear failures as a consequence of the premature termination of the column longitudinal reinforcement. Nevertheless, previous researches for the performance of bridge columns were concentrated on the flexural failure mode. It is well understood that the seismic behaviour of RC bridge piers was dependent on the performance of the plastic hinge of RC bridge piers, the ductility of which was desirable to be computed on the basis of the curvature. Experimental investigation was made to evaluate the variation of the curvature of the plastic hinge  region for the seismic performance of earthquake-damaged RC columns in flexure-shear failure mode. Seven test specimens in the aspect ratio of 2.5 were made with test parameters: confinement ratios, lap splices, and retrofitting FRP materials. They were damaged under series of artificial earthquakes that could be compatible in Korean peninsula. Directly after the pseudo-dynamic test, damaged columns were retested under inelastic reversal cyclic loading under a constant axial load, $P=0.1f_{ck}A_g$. Residual seismic capacity of damaged specimens was evaluated by analzying the moment-curvature hysteresis and the curvature ductility. Test results show that the biggest curvature was developed around 15cm above the footing, which induced the column failure. It was observed that RC bridge specimens with lap-spliced longitudinal steels appeared to fail at low curvature ductility but significant improvement was made in the curvature ductility of RC specimens with FRP straps wrapped around the plastic hinge region. Based on the experimental variation of the curvature of RC specimens, new equivalent length of the plastic hinge region was proposed by considering the lateral confinement in this study. The analytical and experimental relationship between the displacement and the curvature ductility were compared based on this proposal, which gave excellent result.

Multilevel Analysis of Factors Related to Cost and Length of Stay in Acute Myocardial Infarction Patients with Coronary Stenting: Based on Korean National Health Insurance Service's Customized Database in 2010 and 2015 (관상동맥 스텐트를 삽입한 급성 심근경색 환자의 진료비 및 재원일수 관련 요인에 대한 다수준분석: 2010년과 2015년 국민건강보험공단 맞춤형 데이터베이스 자료를 바탕으로)

  • Choi, Boyoung;Lee, Hae-Jong
    • Health Policy and Management
    • /
    • v.30 no.3
    • /
    • pp.418-429
    • /
    • 2020
  • Background: This study aims to analyze the cost and the length of stay (LOS) of acute myocardial infarction (AMI) patients with coronary artery stenting according to the characteristics of individuals and institutions. Methods: The data was collected from Korean National Health Insurance Service's customized database in 2010 and 2015. Chi-square test, t-test, analysis of variance, and multilevel analysis were performed. Results: The intraclass correlation coefficients for cost were 7.02% in 2010, 5.61% in 2015 and for LOS were 3.17%, 1.40%, respectively. The average costs were 9,067,000 won in 2010 and 9,889,000 won in 2015 (p<0.0001). However, the cost in 2015 was lower than the cost applying increased fee. The costs increased in aged 50-59 years, 60-69 years, and aged ≥70 years versus in aged under 49 years. The cost was higher in Charlson comorbidity index (CCI) 3 to 4 and ≥5 than in CCI 0. The costs were lower in male, medical aid recipients, metropolises, and local hospitals in other regions in 2010. LOS decreased from 8.1 days in 2010 to 7.4 days in 2015. It decreased in male, high income group, and the group of admission via emergency room. However, it increased in higher ages and medical aid recipients, and it also increased when CCI rose. The Internal Herfindahl Index was related to LOS in 2010. Conclusion: The variation of hospital level was small compared to the patient level. Therefore, it is important to implement applicable policies at the patient level in order to reduce cost and LOS of AMI patients.

Design of Drilled Shafts Foundation by LRFD in Incheon Bridge Project (인천대교 민자구간의 대구경 현장타설 말뚝기초의 LRFD 설계 적용 사례)

  • Kim, Jeong-Hwan;Lee, Hyun-Gun;Shin, Hyun-Yang;Youn, Man-Geun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.551-561
    • /
    • 2006
  • Incheon bridge project is to construct total 12km long bridges on the sea consist of 800m span length cable stayed bridge, approach bridge and viaduct bridge based on LRFD design specification. To design pile foundations by RCD of each bridge unit, total 4 number of preliminary full scale pile load tests with Osterberg cell method were carried out on the piles for testing. The test load was planned to more than the expected design ultimate capacity and about 29,000tons maximum load was recorded. From the interpretation of test results, design parameters are evaluated and applied to the design. Preliminary pile load test plan and detailed execution of pile load tests are introduced and summarized. The resistance factors are presented for pile design of Incheon Bridge Project in LRFD considering variation of ground conditions and number of test piles.

  • PDF

Experimental testing and evaluation of coating on cables in container fire test facility

  • Aurtherson, P. Babu;Hemanandh, J.;Devarajan, Yuvarajan;Mishra, Ruby;Abraham, Biju Cherian
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1652-1656
    • /
    • 2022
  • Fire tests were conducted on cables using fire-retardant paint employed in nuclear power plants that transmit electrical power, control and instrument signals. The failure criteria of various power and control cables coated with fire retardant coating at three different coating thicknesses (~0.5 mm, 1.0 mm & 1.5 mm) were studied under direct flame test using Container Fire Test Facility (CFTF) based on standard tests for bare cables. A direct flame fire test was conducted for 10 min with an LPG ribbon burner rated at ten by fixing the cable samples in a vertical cable track. Inner sheath temperature was measured until ambient conditions were achieved by natural convection. The cables are visually evaluated for damage and the mass loss percentage. Cable functionality is ascertained by checking for electrical continuity for each sample. The thickness of cable coating on fire exposure is also studied by comparing the transient variation of inner sheath temperature along the Cable length. This study also evaluated the adequacy of fire-retardant coating on cables used for safety-critical equipment in nuclear power plants.

The Effect of Focal Length on Fuel Mixing And Combustion in One-focusing Oxygen Burner (일 초점 산소 버너의 초점 거리가 연료 혼합 및 연소에 미치는 영향)

  • Park, Kweon-Ha;Kim, Ju-Youn
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.814-819
    • /
    • 2011
  • An Oxy-fuel combustion has been studied in order to reduce exhaust emissions and fuel consumption. The flow and flame behaviors are analyzed with focal length variation in one-focussing oxygen burner introduced in this study. Oxygen is supplied into the center of the nozzle, methane fuel is into the outer nozzle of the center, and then oxygen is again supplied into the outer of the fuel nozzle. The test conditions are 5 focal lengths of 100mm to 500mm. The mixing behaviors and temperature distributions are analyzed. The result shows that the shorter the focal length is, the longer the mixing length becomes, and the flame width and length are the biggest in the case of 300mm.

A Study on Bending Fatigue Strength of One Side Fillet Welded T-Joint by SM 490A steel (Sm 490A강으로 제작된 T형 편면용접이음재의 굽힘피로강동에 관한 연구)

  • 엄동석;강성원;이태훈;이해우;조수형
    • Journal of Welding and Joining
    • /
    • v.16 no.5
    • /
    • pp.134-141
    • /
    • 1998
  • In this study, a fillet size for bending fatigue strength of one side fillet welded T-joint, used in box type girder and other welding structure, was investigated by bending fatigue test with or without edge preparation and burn through, with variation of joint shape. As a result, the following conclusions were obtained. (1) In one side fillet welded T-joint, the larger the leg length, the greater the bending fatigue strength. The increase in bending fatigue strength. (2) One side filet welded T-joint with edge preparation showed higher bending fatigue strength than that with twofold-large leg length and without edge preparation. (3) In one side fillet welded T-joint without edge preparation, both manual welding and automatic welding were carried out with same condition. In this case, automatic welding shoed deeper penetration and more increased horizontal leg length than manual welding, so that automatic welding offers grater bending fatigue strength. (4) For one side fillet welded T-joint without edge preparation, the ratio(h/t) of the leg length (h) and the main plate thickness (t) in which toe crack can occur was 1.2 over. (5) In one side fillet welded T-joint with edge preparation, the burn through led to reduced bending fatigue strength. However, this bending fatigue strength was higher than that of one side fillet welded T-joint without edge preparation and with a larger leg length.

  • PDF