• Title/Summary/Keyword: length of cycle

Search Result 831, Processing Time 0.027 seconds

A Study on Temporal Measurement of Size and Concentration for Soot Aggregates among Exhaust Emissions in Diesel Engines (디젤기관 배기 배출물에 있어서 매연 응집체 크기 및 농도의 시간적 계측에 관한 연구)

  • Bae, Myung-Whan;Kamimoto, Takeyuki;Bae, Chang-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.116-124
    • /
    • 2007
  • An optical method to measure the size and number density of soot aggregates in diesel exhaust has been proposed in this study. Two laser beams in co-axial alignment transmit a soot loaded exhaust gas flow, and the transmittance at each wavelength is detected by a photo diode simultaneously. The volume equivalent diameter and number density of soot aggregates in the optical path can be theoretically given by the transmittance values measured at two wavelengths. A test conducted by a single cylinder, 4 cycle, small and DI diesel engine shows that the temporal variations of the size and number density of soot aggregates in the diesel exhaust can be measured by the proposed method at a transient mode operation. It is found that the volume equivalent diameter varied temporally from 70 to 110 nm during the period that high soot concentration is observed. One can also conclude that the optical length longer than 1 m in the dynamic range regarding this method is preferable for measuring soot concentration at the level of $1\;mg/m^3$.

Cost-Effectiveness Analysis of Home-Based Hospice-Palliative Care for Terminal Cancer Patients

  • Kim, Ye-seul;Han, Euna;Lee, Jae-woo;Kang, Hee-Taik
    • Journal of Hospice and Palliative Care
    • /
    • v.25 no.2
    • /
    • pp.76-84
    • /
    • 2022
  • Purpose: We compared cost-effectiveness parameters between inpatient and home-based hospice-palliative care services for terminal cancer patients in Korea. Methods: A decision-analytic Markov model was used to compare the cost-effectiveness of hospice-palliative care in an inpatient unit (inpatient-start group) and at home (home-start group). The model adopted a healthcare system perspective, with a 9-week horizon and a 1-week cycle length. The transition probabilities were calculated based on the reports from the Korean National Cancer Center in 2017 and Health Insurance Review & Assessment Service in 2020. Quality of life (QOL) was converted to the quality-adjusted life week (QALW). Modeling and cost-effectiveness analysis were performed with TreeAge software. The weekly medical cost was estimated to be 2,481,479 Korean won (KRW) for inpatient hospice-palliative care and 225,688 KRW for home-based hospice-palliative care. One-way sensitivity analysis was used to assess the impact of different scenarios and assumptions on the model results. Results: Compared with the inpatient-start group, the incremental cost of the home-start group was 697,657 KRW, and the incremental effectiveness based on QOL was 0.88 QALW. The incremental cost-effectiveness ratio (ICER) of the home-start group was 796,476 KRW/QALW. Based on one-way sensitivity analyses, the ICER was predicted to increase to 1,626,988 KRW/QALW if the weekly cost of home-based hospice doubled, but it was estimated to decrease to -2,898,361 KRW/QALW if death rates at home doubled. Conclusion: Home-based hospice-palliative care may be more cost-effective than inpatient hospice-palliative care. Home-based hospice appears to be affordable even if the associated medical expenditures double.

Biomechanical Analysis of the Elderly Gait with a Walking Assistive Device (노인의 보행보조기구 사용 보행시 보행패턴의 변화연구)

  • Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.1-9
    • /
    • 2007
  • Walking is not only an essential component of the human mobility, but also is a good exercise. Inability to walk freely can reduce an individual's quality of life and independence substantially. Being a relatively low impact activity, walking is particularly good for the elderly and research has shown that regular walking in the elderly reduces the chance of fall-related injuries and mental diseases as well. In spite of the documented benefits of regular walking, it is still difficult to walk without the aid of assistive devices for the frail elderly who have lower extremity problems. Assistive walking devices(AWD), such as crutches, canes, hiking-poles, T-Poles and walkers, are often prescribed to the elderly to make their walking be safe and efficient. Many researchers have demonstrated the effects of AWDs such as reducing lower extremity loading, improved dynamic/gait stability, yet, no study has been done for gait pattern when the elderly gait with AWDs. Therefore, the purpose of this study was to examine whether T-Poles, one of the AWDs, change the elderly gait pattern. Eight community-dwelling female elderly participated in this study. Laboratory kinematics during walking with T-Poles(PW) and with out T-Poles(NPW) was assessed. PW showed significant increase in step width, stride length, gait velocity and decrease in swing time. No significances were found in lower body joint angles but meaningful trend and pattern were found. Maybe the reason was due to the participants. Our participants were healthy enough so that the effect of T-Poles was minimum. PW also showed typical gait phases which are no single support phase during a gait cycle. It indicates that walking with T-Poles may guarantee safe and confident walking to the frail elderly.

Vortex-induced vibration of a long flexible cylinder in uniform cross-flow

  • Ji, Chunning;Peng, Ziteng;Alam, Md. Mahbub;Chen, Weilin;Xu, Dong
    • Wind and Structures
    • /
    • v.26 no.5
    • /
    • pp.267-277
    • /
    • 2018
  • Numerical simulations are performed of a long flexible cylinder undergoing vortex-induced vibration at a Reynolds number of 500. The cylinder is pinned at both ends, having an aspect ratio of 100 (cylinder length to cylinder diameter) and a mass ratio of 4.2 (structural mass to displaced fluid mass). Temporal and spatial information on the cross-flow (CF) and in-line (IL) vibrations is extracted. High modal vibrations up to the $6^{th}$ in the CF direction and the $11^{th}$ in the IL direction are observed. Both the CF and IL vibrations feature a multi-mode mixed pattern. Mode competition is observed. The $2^{nd}$ mode with a low frequency dominates the IL vibration and its existence is attributed to a wave group propagating back and forth along the span. Distributions of fluid force coefficients are correlated to those of the CF and IL vibrations along the span. Histograms of the x'-y motion phase difference are evaluated from the total simulation time and a complete vibration cycle representing the standing or travelling wave pattern. Correlations between the phase difference and the vibrations are discussed. Vortex structures behind the cylinder show an interwoven near-wake pattern when the standing wave pattern dominates, but an oblique near-wake pattern when the travelling wave pattern prevails.

Analysis of the Breakdown repair time of the Building Components in Public Rental-Housing Types (공공임대주택 유형별 부재의 사후보전 수선시기 설정연구)

  • Lee, KangHee;Ahn, YoungHan;Chae, ChangU
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.129-136
    • /
    • 2013
  • The rental housing has played a key role to supply a decent living space for the low-income households. The owner of the rental housing should maintain and manage the building physical condition. On the other hand, rents should use the housing without any damage and pay a certain fare for the rent. A rent is classified into two types : private and public. The public rent is mainly to supply a living space for non-available home owner with a low-rent fare. Many of public rent are built and supplied by the public institution or local government. The supplier would take a responsibility to maintain the building and components, reflected by the maintenance plan and repair scope. In this paper, it aimed at providing the repair time in building components of the public rental housing such as lighting, electrical cable, paintings and etc.. The repair time is analyzed with three calculation methods which are solved by the probability and empirical approach. Results are as follows : First, the repair time of the electrical facilities are maintained with 11yr, 10yr and 7 in permanent, public and redevelopment rent respectively. The roof proof has a repair time with 14yr, 11yr and 8 in permanent, public and redevelopment rent housing respectively. Second, Most of the components has a prior length of the repair time in permanent, public and redevelopment rent sequently. There is a difference in repair time according to the rental types. Therefore, it would continue to research the difference in aspect of the living style, building physics, living consciousness and etc.

Comparison of Plant Growth and Morphological Characteristics Among the Korean Ginseng, the American Ginseng and the Bamboo Ginseng (고려인삼, 미국삼 및 죽절삼의 생육 및 형태적 특성 비교)

  • 정열영;이명구
    • Journal of Ginseng Research
    • /
    • v.22 no.2
    • /
    • pp.147-153
    • /
    • 1998
  • An investigation was conducted to ascertain the basic information on characteristics of growth and morphological characters among the Korean (Panax. ginseng), the American (Panax. quinquefolium) and the Bamboo (Panax. japonicus) ginseng. In aerial parts growth of the ginseng species by age, The Korean ginseng and American ginseng's stem and leaf growth was alike in 2-4 years old, but growth cycle changed in 6 years old. The Korean ginseng was more vigorous than the American ginseng. The Korean ginseng roots were highly observed in ratio of red skin roots among three species, whereas The American ginseng roots were highly infected by root rot. It seems to be variable depending on growing stage and species. The Korean ginseng flowered about the middle of May, the American ginseng early June, and the Bamboo ginseng was late of May, The berry color of the ginseng species was observed, The Korean and American ginseng's mature berry color was red, The Bamboo ginseng's berry was three type of color and shape. In root characteristics of the seedling, Korean (p. ginseng), American (p. quinquefolium) ginseng's root shape was similarity in type, the bamboo ginseng showed different type, which root length and root weight was smaller than those of ginseng. In morphological characters of Leaf surface, pollen, and stoma, the Korean ginseng and American ginseng had crystal rosette on epidermis cell, but the Bamboo ginseng didn't has crystal rosette. Pollen shape observed tricolpate pollen and size was media type among the ginseng species, and also guard cell was anomocytic type, which were observed by scanning electronic microscope.

  • PDF

An Experimental Study on Aerodynamic Characteristics of a Flapping Wing (플래핑 날개의 공력특성에 관한 실험적 연구)

  • Song, Woo-Gil;Chang, Jo-Won;Jeon, Chang-Su
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.17 no.4
    • /
    • pp.8-16
    • /
    • 2009
  • An experimental study was carried out to investigate aerodynamic characteristics on reduced frequency of flapping wings. The half span of the wing is 28cm, and the mean chord length of wing is 10cm. In flight, the Reynolds Number range of birds is about $10^4$, and the reduced frequency during a level flight is 0.25. The experimental variables of present study were set to have similar conditions with the bird flight's one. The freestream velocities in a wind tunnel were 2.50, 3.75 and $5.00^m/s$, and the corresponding Reynolds numbers were $1.7{\times}10^4$, $2.5{\times}10^4$ and $3.3{\times}10^4$, respectively. The wing beat frequencies of an experimental model were 2, 3 and 4Hz, and the corresponding reduced frequency was decided between 0.1 and 0.5. Aerodynamic forces of an experimental flapping model were measured by using 2 axis load-cell. Inertial forces measured in a vacuum chamber were removed from measuring forces in the wind tunnel in order to acquire pure aerodynamic forces. Hall sensors and laser trigger were used to make sure the exact position of wings during the flapping motion. Results show that the ratio of downstroke in a wing beat cycle is increased as a wing beat frequency increases. The instantaneous lift coefficient is the maximum value at the end of downstroke of flapping wing model. It is found that a critical reduced frequency with large lift coefficient is existed near k=0.25.

  • PDF

Firing Test of Core Engine for Pre-cooled Turbojet Engine

  • Taguchi, Hideyuki;Sato, Tetsuya;Kobayashi, Hiroaiki;Kojima, Takayuki;Fukiba, Katsuyoshi;Masaki, Daisaku;Okai, Keiichi;Fujita, Kazuhisa;Hongoh, Motoyuki;Sawai, Shujiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.115-121
    • /
    • 2008
  • A core engine for pre-cooled turbojet engines is designed and its component performances are examined both by CFD analyses and experiments. The engine is designed for a flight demonstration of precooled turbojet engine cycle. The engine uses gas hydrogen as fuel. The external boundary including measurement devices is set within $23cm{\times}23cm$ of rectangular cross section, in order to install the engine downstream of the air intake. The rotation speed is 80000 rpm at design point. Mixed flow compressor is selected to attain high pressure ratio and small diameter by single stage. Reverse type main combustor is selected to reduce the engine diameter and the rotating shaft length. The temperature at main combustor is determined by the temperature limit of non-cooled turbine. High loading turbine is designed to attain high pressure ratio by single stage. The firing test of the core engine is conducted using components of small pre-cooled turbojet engine. Gas hydrogen is injected into the main burner and hot gas is generated to drive the turbine. Air flow rate of the compressor can be modulated by a variable geometry exhaust nozzle, which is connected downstream of the core engine. As a result, 75% rotation speed is attained without hazardous vibration and heat damage. Aerodynamic performances of both compressor and turbine are obtained and evaluated independently.

  • PDF

Dynamic Characteristics of Coaxial Swirl-jet Injector with Acoustic Excitation (동축형 스월-제트 분사기의 음향가진에 따른 동특성)

  • Bae, Jinhyun;Kim, Taesung;Jeong, Seokgyu;Jeong, Chanyeong;Choi, Jeong Yeol;Yoon, Youngbin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.99-107
    • /
    • 2018
  • In this study, the injector transfer function (ITF) of a gas-gas coaxial jet-swirl injector is measured by perturbing jet or swirl flow using a speaker as jet flow increases. As a result of measuring the ITF varying feed system length, a peak occurs at a resonance frequency of space where the perturbed flow passes. With jet excitation, the ITF magnitude decreases, but increases thereafter as increasing the jet flow. Therefore the larger the velocity difference between jet and swirl flow, the larger the ITF. With swirl excitation, ITF decreases as increasing the jet flow because of the energy decrease with respect to the constant downstream flow.

Performance Evaluation of Propane(R290)/Isobutane(R600a) Mixture as a Substitute for CFC12 in Domestic Refrigerators (프로판/이소부탄 혼합냉매를 적용한 가정용 냉장고의 성능에 관한 연구)

  • Lim, B.H.;Park, Y.B.;Yoo, H.K.;Jung, D.S.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.249-265
    • /
    • 1995
  • The performance of a refrigerant mixture of propane(R290)/isobutane(R600a) as a substitute for CFC12 was investigated in a domestic refrigerator with single evaporator. A thermodynamic cycle simulation indicated an increase in COP of a 1.7 to 2.4% with R-290/600a in the composition range of 0.2 to 0.6 mass fraction of R290 compared to CFC12. For the tests, two units($299{\ell}$, $465{\ell}$) were used. All refrigeration components remained the same throughout the tests, except that the length of capillary tube and amount of charge were changed for the mixture. The refrigerators were fully instrumented with more than 20 thermocouples, 2 pressure transducers, and watt/watt-hour meter for each refrigerator. 'Energy consumption test' and 'no load pulldown test' were performed under the same condition. The experimental results obtained with the same compressor indicated that R-290/600a mixture at 0.6 mass fraction of R290 showed a 3 to 5% increase in energy efficiency and a faster cooling speed compared to CFC12. The R-290/600a mixture showed a shorter compressor on-time and a lower compressor dome temperature than CFC12. In conclusion, the proposed hydrocarbon mixture seems to be an appropriate candidate to replace CFC12 without causing more environmental problems.

  • PDF