• Title/Summary/Keyword: length of copper pipe

Search Result 34, Processing Time 0.028 seconds

A Study on the Thermal Performance of Concentric Annular Heat Pipes (동심형 히트파이프의 열성능에 관한 연구)

  • Kim, D.H.;Park, S.Y.;Boo, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1412-1417
    • /
    • 2004
  • Concentric annular heat pipes having the length of 200 mm and the outside diameter of 25.4 mm were manufactured and tested. The inside diameters of the heat pipes were 11.3 mm and 8.1 mm and the material of the container was copper. To compare with thermal performances between the concentric annular heat pipe and a copper block with same shape, start-up and isothermal performance were tested. In the result, the start-up of the concentric annular heat pipe was influenced by the start-up of their heat source. The concentric annular heat pipe reached at steady state faster then the same shape of copper block. The maximum wall temperature difference of the concentric annular heat pipe on whole surface was $4.6^{\circ}C$, and the case of the copper block was $16.5^{\circ}C$.

  • PDF

Electronics Cooling Using the Porous Metallic Materials

  • Lucaci, Mariana;Orban, Radu L.;Lungu, Magdalena;Enescu, Elena;Gavriliu, Stefania
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.315-316
    • /
    • 2006
  • The paper presents some results regarding the obtaining of some copper heat pipes with a porous copper internal layer for electronic components cooling. The heat pipes were realized by sintering of spherical copper powders of $90{\div}125\;{\mu}m$ size directly on the internal side of a copper pipe of 18 mm in diameter. The obtained pipes were then brazed in order to obtain a heat pipe of 0.5 m in length. After that, the heat pipe was sealed and filled with a small quantity of distilled water as working fluid. To establish the total heat transport coefficient and the thermal flow transferred at the evaporator, some external devices were realized to allow the heating of the evaporator and the cooling of the condenser. Water heat pipes are explored in the intermediate temperature range of 303 up to 500 K. Test data are reported for copper water heat pipe, which was tested under different orientations. The obtained results show that the water heat pipe has a good thermal transfer performance in the temperatures range between 345 and 463 K.

  • PDF

DEFECT DETECTION WITHIN A PIPE USING ULTRASOUND EXCITED THERMOGRAPHY

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.637-646
    • /
    • 2007
  • An UET (ultrasound excited thermography) has been used for several years for a remote non-destructive testing in the automotive and aircraft industry. It provides a thermo sonic image for a defect detection. A thermograhy is based On a propagation and a reflection of a thermal wave, which is launched from the surface into the inspected sample by an absorption of a modulated radiation. For an energy deposition to a sample, the UET uses an ultrasound excited vibration energy as an internal heat source. In this paper the applicability of the UET for a realtime defect detection is described. Measurements were performed on two kinds of pipes made from a copper and a CFRP material. In the interior of the CFRP pipe (70mm diameter), a groove (width - 6mm, depth - 2.7mm, and length - 70mm) was engraved by a milling. In the case of the copper pipe, a defect was made with a groove (width - 2mm, depth - 1mm, and length - 110 mm) by the same method. An ultrasonic vibration energy of a pulsed type is injected into the exterior side of the pipe. A hot spot, which is a small area around the defect was considerably heated up when compared to the other intact areas, was observed. A test On a damaged copper pipe produced a thermo sonic image, which was an excellent image contrast when compared to a CFRP pipe. Test on a CFRP pipe with a subsurface defect revealed a thermo sonic image at the groove position which was a relatively weak contrast.

A Study on the Miniature Loop Heat Pipe with Non-inverted Meniscus type Capillary Structure (Non-inverted Meniscus식 모세관 구조물을 이용한 소형 루프히트파이프에 관한 실험적 연구)

  • Chung, Won-Bok;Park, Soo-Yong;Doctarau, Viachaslau-V.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2142-2147
    • /
    • 2007
  • Experimental study was conducted to evaluate the performance of a miniature loop heat pipe (MLHP) with non-inverted meniscus type capillary structure. All parts of MLHP in this study were made of copper including the capillary structure and the distilled water was used as a working fluid of MLHP. The outer diameter of evaporator was 9 mm and its length was 119 mm. The effective pore size of the capillary structure was 30 micron and its porosity was 60%. The vapor transport line, the liquid transport line and the condenser were consisted of single 4.0 mm copper tube. The distance between the evaporator and the condenser region was 200 mm and the length of the loop was 969 mm. This MLHP was operated successfully at any orientation but the gravity highly influenced the thermal performance of the MLHP. The maximum thermal load was 130 watts at the bottom heat mode and the 20 watts at the top heat mode.

  • PDF

Analysis on Pressure and Temperature wave of Self Oscillating Heat Pipe (자려 진동 히트파이프의 압력 및 온도 파형 해석)

  • Choi, J.H.;Yoon, D.H.;Oh, C.;Kim, M.H.;Yoon, S.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.43-49
    • /
    • 2000
  • Heat transfer characteristics of self oscillating heat pipe were experimentally investigated for the effect of fill charge ratios and heat loads. The heat pipe used for this study is made of copper capillary, has 0.002m internal diameter, a 0.34m length in one turn and consists of 19 turns. Heating and cooling section each have a length of 70mm. Water was used as working fluid inside heat pipe. As the experimental results, the self oscillating heat pipe was operated by self-exited oscillation and circulation of working fluid and the oscillation within the self oscillating heat pipe assumed chaotic behavior.

  • PDF

Changes in Dimension and Mechanical Characteristics of Copper Pipe System during Pipe Processing (동 파이프 성형 시 치수 변화 및 배관 시스템의 기계적 특성 변화)

  • Choi, Jei Min;Kim, Soo Min;Chae, Soo-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.7
    • /
    • pp.615-622
    • /
    • 2014
  • Copper pipes have been widely used as components of System Air-Conditioner due to high thermal conductivity. This system consists of 150 pipes, which are approximately 10m long in total. Dimensional changes occur during pipe processing such as expansion, reduction and bending. This processing induces changes in length of pipes and makes dimensional differences from original pipes. The summation of the differences of pipes components leads to make huge cumulative dimensional differences. The cumulative differences can cause serious problems such as crack, refrigerant leakage. However the differences have not been considered so far. To satisfy target quality of the system, it is essential to predict and calibrate the differences. In this paper, the changes in dimension were predicted using FEM and it was found that cumulative differences could cause indesirable stress during assembly process. As a result, dimensional differences or indesirable stress could be reduced using the proposed method.

Experimental Investigations on the Temperature Characteristics of Oscillating Heat Pipe with Various Filling Ratio

  • Jeong, Hyo-Min;Chung, Han-Shik;Lee, Kwang-Sung;Tanshen, Md.Riyad;Lee, Tae-Jin;Lee, Sin-Il
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.47-53
    • /
    • 2013
  • The article focuses on the Temperature characteristics inside single loop oscillating heat pipe (OHPs). In this paper, heat pipe is experimentally studied thereby providing vital information on the parameter dependency of their thermal performance. The impact depiction has been done for the variation of tube model of the device. OHPs are made of copper capillary tubes of outer diameter 6.25 mm, inner diameter 4 mm heated by constant temperature water bath cooled by ambient temperature. Using four types of OHPs of copper capillary tubes length of 1500mm and HP length 650mm inside tubes working fluid is R-22 Pressure 8 bar and mass 34g,32g,28g,16g. The results indicate a strong influence of filling ratio on the performance.

Experimental Study of Heat Transfer Performance of Variable Conductance Heat Pipe with Screen Mesh Wick (Mesh Wick형 가변전열 히트파이프의 열전달 성능에 관한 실험적 연구)

  • Park, Y.S.;Byon, G.S.;Suh, J.S.;Park, K.H.;Lee, K.W.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.7-12
    • /
    • 2003
  • heat pipe with screen meshed wick. The heat pipe was designed in 200 screen meshs, 500 mm length and 12mm O.D tube of copper, water as working fluid and nitrogen as non-condensible gas. Heat pipe used in this study has evaporator, condenser and adiabatic section, respectively. Experimental data of wall temperature distribution along axial length is presented for heat transport capacity, condensor cooling water temperature change, degrees of an inclination angle, and operating temperature.

  • PDF

Effects of Rectifier and Copper Grid Interference on the Detection Reliability of Coating Flaws on Buried Pipes (매설 배관 피복 결함 탐상 정확도에 미치는 인접 정류기 및 접지 구리망 간섭의 영향)

  • Kim, M.G.;Lim, B.T.;Kim, K.T.;Chang, H.Y.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.211-223
    • /
    • 2020
  • The external corrosion of buried piping can be controlled using both coating and cathodic protection. Several factors are involved in the damage and deterioration of the coating on pipes. There are many detection methods for coating defects on pipes and the direct current voltage gradient (DCVG) method is one of the most powerful methods. However, the detection reliability of DCVG can be affected by interferences such as stray current, metal objects connected to rectifiers, and copper grids. Therefore, this study focused on the interference effects of rectifiers and a copper grid on the reliability of coating flaw detection. As the length of the interference pipe connected to the rectifier increased, the reliability decreased. In contrast, as the distance between the pipe and the copper grid increased, the reliability of the coating flaw detection increased. The detection results produced by the DCVG method were discussed using current and potential simulations for a pipe with a rectifier and copper grid interference in the soil.

Experimental study of the heat pipe phenomenon in porous media heated from above (상부가열인 다공물질내의 열파이프 현상에 관한 실험적 연구)

  • 이진호;김홍제;함윤영;남궁규완
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.825-832
    • /
    • 1988
  • An experiment was performed to study the heat pipe phenomenon of porous media heated above at one-dimensional steady state for the range of heat flux, 300 W/ $m^{2}$ ~ 2000w/ $m^{2}$. Glass beads, sand, and copper particles were used as porous media and distilled water was used as a working fluid. Result of experiment shows that the length of the two-phase zone increases with the decreasing particle size for the same heat flux. At relatively lower heat flux the length of the two-phase zone increases with the increasing heat flux, which contradicts the result of earlier work. However, its length remains nearly constant when the heat flux increases above a certain value. The length of the two-phase zone is proportional to the product of the heat flux by the hydrostatic capillary height under the limited value on heat flux, that is, $l_{t}$ = A(q. $l_{cap}$)+B, q.leg.1/A(C+B/ $l_{cap}$) where A is 1.7*10$^{-4}$ $m^{2}$/w, B is 1.9*10$^{-2}$ m, and C is 0.43 for copper particles and 0.31 for glass beads and sand.d.d.d.