• Title/Summary/Keyword: length and diameter

Search Result 4,136, Processing Time 0.041 seconds

Normal Corpus Callosum Dimensions Measured by MRI (MR Midsagittal 영상을 이용한 정상 뇌량의 크기 측정)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.277-285
    • /
    • 2008
  • As a result of measuring the size of corpus callosum in normal Korean people by using MRI, the following conclusions were obtained. 1. Maximum, minimum, and mean values by the region in whole subjects 1) Anteroposterior length amounted to the mean with 69.30mm, the minimum with 50.70mm, and the maximum with 80.40mm. 2) Diameter of genu amounted to the mean with 11.93mm, the minimum with 6.00mm, and the maximum with 18.50mm. 3) Diameter of mid body amounted to the mean with 7.00mm, the minimum with 3.40mm, and the maximum with 10.40mm. 4) Diameter of narrowing portion amounted to the mean with 4.51mm, the minimum with 0.80mm, and the maximum with 9.50mm. 5) Diameter of splenium amounted to the mean with 12.17mm, the minimum with 6.90mm, and the maximum with 17.20mm. 2. Comparison by region according to the gender in the whole subjects 1) Anteroposterior length was bigger in men than in women, and showed the significant difference depending on gender. 2) Diameter of genu, diameter of mid body, and diameter of narrowing portion were bigger in men than in women, but there was no significant difference. 3) Diameter of splenium was bigger in men than in women, and showed the statistically significant difference. 3. Comparison by region according to the age in the whole subjects 1) Anteroposterior length was the biggest in the 50s at the age, and was smaller in heir 10s than other age levels. In addition, the significant difference was indicated depending on age. 2) Diameter of genu and diameter of mid body were the biggest in their 30s, and were smaller in the 60s than other age levels. And, the statistically significant difference was indicated. 3) Diameter of narrowing portion was the thickest in their 20s, and was thinner in their 60s than other age levels. And, the significant difference was indicated depending on age. 4) Diameter of splenium was the thickest in their 30s, and was thinner in their 10s than other age levels. And, the statistically significant difference was indicated. 4. Correlation by region in whole subjects 1) Diameter of genu showed the statistically significant positive correlation with anteroposterior length. 2) Diameter of mid body showed the statistically significant positive correlation with anteroposterior length and diameter of genu. 3) Diameter of narrowing portion didn't show the statistically significant correlation with anteroposterior length, but showed the statistically significant positive correlation with diameter of genu and diameter of mid body. 4) Diameter of splenium showed the statistically significant positive correlation with anteroposterior length, diameter of genu, diameter of mid body, and diameter of narrowing portion.

  • PDF

Discharge Characteristics of Rotating Orifices with Length-to-Diameter Ratios and Inlet Corner Radii (길이 대 직경 비와 입구 모서리 반경에 따른 회전 오리피스의 송출 특성)

  • Ha, Kyoung-Pyo;Kang, Se-Won;Kauh, Sang-Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.957-966
    • /
    • 2000
  • The effect of rotation on the discharge coefficient of orifices with various length-to-diameter ratios and two different inlet corner radii was studied. Length-to-diameter ratios of the orifices range from 0.2 to 10, while the inlet shapes are square edged, or round edges of radius-to-diameter ratio of 0.5. From the experiment, we found that rotational discharge coefficient and Rotation number, when based on ideal exit velocity of the orifice considering momentum transfer from the rotor, describe the effect of rotation very well. In this study, the discharge coefficients of rotating orifices are shown to behave similar to those of the well-known non-rotating orifices. For both rotating and non-rotating orifices, the discharge coefficients increase with the length-to-diameter ratio until a maximum is reached. The flow reattachments in the relatively short orifices are responsible for the increase. The coefficient then decreases with the length-to-diameter ratio due to the friction loss along the orifice bore. The length-to-diameter ratio that yields maximum discharge coefficient, however, increases with the Rotation number because the increased flow-approaching angle requires larger length-to-diameter ratio for complete reattachment. The length-to-diameter ratio for complete reattachment is shorter for round edged orifices than that of square edged orifices by about a unit length-to-diameter ratio.

System Performance for Length and Diameter of Capillary Tube using R-1270 (모세관 길이와 관경 변화에 따른 R-1270의 성능특성)

  • Lee, Ho-Saeng;Kim, Hyun-Woo;Choi, Won-Jae;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.646-652
    • /
    • 2009
  • Experimental results for performance characteristics of HCs refrigerant R-1270 and HCFC refrigerant R-22 during refrigeration system using capillary tube are presented. The system consists of compressor, condenser, capillary tube, evaporator and peripheral devices. Length and diameter of capillary tube are varied for this investigation. The refrigerant mass flow increased as the diameter of capillary tube increased and the length of capillary tube decreased. A refrigeration capacity and compressor work of R-1270 in same length and diameter of capillary tube showed the higher values than those of R-22. A coefficient of performance showed the highest value when the length and diameter of capillary tube are 105 cm and 1.8 mm in this experimental conditions.

Effect of Diameter and Length on the Absorption Performance in a Vertical Absorber Tube (수직형 흡수기 성능에 미치는 흡수기 전열관의 직경과 길이의 영향)

  • 서정훈;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1214-1222
    • /
    • 2001
  • The present study investigated the effect of diameter and length on the absorption performance of a vertical falling film type absorber using $LiBr-H_2$O solution of 60 wt%. The parameters were diameter of absorber (17.2, 23.4, 31.1 mm), length of absorber (771, 1150, 1528 mm), and film Reynolds numbers (50, 70, 90, 110, 130, 150). As the diameter of the absorber was increased, the absorption mass flux, Sherwood number, heat flux, and heat transfer coefficient were increased, in which Sherwood number and heat transfer coefficient were increased up to 13% and 30% respectively. As the length of the absorber was increased, the total absorption rate and heat transfer coefficient were increased by 37% and 35% respectively, while the absorption mass flux was decreased.

  • PDF

Diallel Cross Analysis of Characters in Barley (이면교잡에 의한 대맥형질의 유전분석)

  • Chung, Won-Bok;Chung, Dae-Soo;Takeda, Kazuyoshi;Sato, Kazuhiro
    • Journal of Life Science
    • /
    • v.7 no.1
    • /
    • pp.59-65
    • /
    • 1997
  • In this experiment, gene actions were analysized for seven barley parents in order to obtain basic information on their genetic improvement by diallel crosses. The results obtained were summarized as follows. In analysis of variance, additive, dominant, maternal and reciprocal effects were observed significantly for culm length, tiller number, number of spiked per plant, culm diameter, awn length, leaf width, number of grains per spike, and 1000 grain weight. Over-dominance was shown by Vr-Wr graphic analysis in five characters such as tiller number, number of spikes per plant, length of flag leaf, number of grains per spike, and 1000 grain weight, and partial dominance in four characters such as culm length, culm diameter, awn length, and leaf width. Component of genetic varience analyzed for four characters such as culm diameter, awn length, length of flag leaf, and leaf width showed that additive effects were higher than dominant effects. Culm length, tiller number, number of spikes per plant, number of grains per spike, and 1000 grain weight showed dominant effects higher than additive effects. The narrow-sense heritability for awn length, leaf width, and number of grains per spike showed high values as more than 0.62, while broad-sense heritability for culm length, number of spikes per plant, culm diameter, awn length, leaf width, number of grains per spike, and 1000 grain weight showed high values as more than 0.65.

  • PDF

The Characteristics and Correlation Coefficients of Characters in Panax ginseng, Violet-stem Variant and Yellow. berry Variant, and Panax quinquefolium. (고려인삼과 미국삼의 형질특성 및 형질간 상관관계)

  • 최광태;안상득;박규진;양덕조
    • Journal of Ginseng Research
    • /
    • v.7 no.2
    • /
    • pp.133-147
    • /
    • 1983
  • This study was carried out to obtain the basic information for the development of new ginseng varieties. The two variants (violet-stem variant and yellow-berry variant) of Korean ginseng (Panax ginseng C.A. Meyer) and American ginseng (Panax quinquefolium L.) of one to four-year were used for this study. All of the characteristics, such as leaf length, leaf width, petiol length, number of leaves per plant, number of leaflets per plants, stem diameter, stem length, number of stems per plant, root length, primary root length, root diameter, root weight were determined and correlations among them were estimated. The results obtained were summarized as follows. 1. Leaf length, petiol length, number of leaves per plant, and number of leaflets per plant of Panax ginseng, violet-stem variant and yellow-berry variant, were larger than those of Panax quinquefolium at all of the plant ages, while leaf width was wider in Panax quinquefolium. 2. The length of stem of Panax quinquefolium was shorter than that of Panax ginseng, and the frequency of multi-stem plants at 4-year-old ginseng was larger in violet-stem variant than in Panax quinquefolium and yellow-berry variant. 3. In the characteristics of ginseng root, the primary root length of Panax ginseng, violet-stem variant and yellow-berry variant, were less than that of Panax quinquefolium, while root weight, root diameter, and umber of secondary root related to yield were larger in Panax ginseng. 4. The root weight per plant related to the yield had positive and highly significant correlations with stem diameter, leaf length, leaf length, leaf width, number of compound leaves and leaflets in Panax ginseng and Panax quinguefolium. 5. The root weight related to the wield of ginseng had been influenced to stem diameter, leaf length, and leaf width directly, and number of compound leaves and leaflets indirectly. 6. The number, total area and activity of stomate per mm2 of Panax quinquefolium were more, larger and stronger than those of Panax ginseng.

  • PDF

Length Effects of Hetero-Core Optical Biosensor based on Evanescent Field Absorption

  • Shim, Joon-Hwon;Chan, Joo-Kwong;Sohn, Kyung-Rak
    • Journal of Navigation and Port Research
    • /
    • v.32 no.9
    • /
    • pp.723-727
    • /
    • 2008
  • Sensing performances of evanescent field absorption (EFA) hetero-core fiber sensor has been presented based on EFA by changing the length and the core diameter of the single mode fiber. Experimental results have demonstrated a good feature in their relationship between the length and the core diameter of the single mode fiber. The sensor consists of 2 fiber optics which have the same cladding diameter of $125{\mu}m$ However one fiber optic used is single mode and has varying core diameter ranging from 3.3 to $5.6{\mu}m$. The other fiber is multimode type and has a thicker fixed core diameter of $62.5{\mu}m$. The 2 fiber optics are thermally spliced together. Experiments conducted to measure the resonance wavelength were carried out over a range of refractive index, to find the optimum sensing length Experiments show that core diameter of the single mode fiber and sensing length offects the linearity and sensitivity.

Degree of Heterosis and Heterobeltiosis in F1 Hybrids of Eggplant (가지 F1세대의 잡종강세 정도)

  • Oh Ju-Sung;Hwang Pil-Seong;Chung Won-Bok
    • Journal of Life Science
    • /
    • v.15 no.1 s.68
    • /
    • pp.132-135
    • /
    • 2005
  • This experiment was performed to obtain the basic information on heterosis and heterobeltiosis of quantitative characters in the eggplant by crossing of varieties. The heterosis and heterobeltiosis were estimated in Fl generation. The results were as follows, based on the graphical analysis, the characters, plant height, stem diameter, fruit weight, leaf length, leaf width, and fruit number per plant(yield) were assumed to inherit dominance, and fruit length and fruit diameter were found to inherit incomplete dominance. The degree of positive heterosis of plant height, stem diameter, fruit weight, fruit length, fruit diameter, leaf length, leaf width, and fruit diameter, leaf width, leaf length, fruit weight, and stem diameter showed negative heterobeltiosis.

Analysis of a Cylindrical Pin Fin with Variable Diameter (직경이 변하는 원통형 Pin 핀의 해석)

  • Kang, Hyung-Suk;Kim, Jong-Ug
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.71-75
    • /
    • 2007
  • A cylindrical pin fin with variable diameter is analyzed by using the one dimensional analytical method. Heat loss and fin efficiency are presented as a function of the fin diameter, length and convection characteristic numbers ratio. The relationship between the fin diameter and convection characteristic number over the fin for the same amount of heat loss is shown. One of the results indicates the fin efficiency increases as the fin diameter increases while that decreases as the fin length increases.

  • PDF

The Surface Roughness of Aluminium Material according to Cutting Conditions in the CNC Lathe Working (CNC 선반가공(旋盤加工)에서 절삭조건(切削條件)에 따른 알루미늄의 표면(表面)거칠기 변화(變化))

  • Kim, Tae-Wook;Son, Ki-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.201-208
    • /
    • 2002
  • The machine tool which operates by hand is replacing by CNC machine tool to improve the quality of the product and the productivity in modem mechanic industry. The precision of machine part is influenced greatly the surface roughness by cutting condition of machine tool. So this study was performed to examine the aluminium surface roughness of section according to change of strength rating, nose radius, cutting speed, using live center. The results of this study are as follows; 1. In the case of 56mm diameter of test piece(length is below triple of diameter), whether establish the live center or not, doesn't influence to the surface roughness, and it is possible to make product without the live center. 2. The average surface roughness of 42mm diameter(length is quadruple of diameter) is similar to the 56mm diameter in the cutting condition of nose radius 0.8mm and cutting speed 140mm/min, but there are increases and differences in other cutting conditions. 3. In the case of test piece length more 70m/min(140m/mm) and nose radius improved greatly using the live center. 4. In the case of test piece length is quintuple of diameter, the nose radius must choose big tool and increase the cutting speed in preference live center establishment availability to improve that is surface roughness. Conclusively, if aluminum test piece length is fewer than triple of diameter, can process without establishing live center. If aluminum test piece length is more than quintuple of diameter, cutting conditions to improve surface roughness are (1) cutting speed (2) nose radius (3) whether the live center uses or not.

  • PDF