• Title/Summary/Keyword: leaks

Search Result 461, Processing Time 0.024 seconds

Experimental and Clinical Study of Staple-Line Reinforcement Using Expanded Polytetrafluoroethylene in Thoracoscopic Bullectomy for Spontaneous Pneumothorax (자연 기흉 환자에서 봉합선 보강이 흉강경 폐부분 절제술에 미치는 영향: 동물실험 및 임상연구)

  • 문석환;심성보;왕영필;윤정섭;조건현;박재길;박만실;최시영;곽문섭
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.904-910
    • /
    • 2003
  • Thoracoscopic bullectomy (VATS-B) is now the preferred treatment for spontaneous pneumothorax despite of higher recurrence rate than open thoracotomy. Several methods have been used to prevent this problem. The effectiveness of staple line reinforcement (SLR) in VATA-B using endostaplers was assessed by clinical and experimental study. Meterial and Method: In experimental study, canine lungs were harvested immediately (group I N=5) and 48 hours (group II N=5) after stapling. The pressures at which initial air leaks occurred were measured. In clinical study from February 1997 to March 1999, 106 procedures in 104 patients undergoing VATS-B for spontaneous pneumothorax were classified into two groups according to the presence of SLR and were compared. Result: The average pressure of the initial air leakage was significantly higher in SLR than that of staples alone (18$\pm$1.6 vs 48$\pm$3 mm Hg in group I; 23.8$\pm$1.9 vs 54$\pm$4.6 mm Hg in group II, p<0.001). In the clinical data, there were significant differences seen in the duration of drainage, the total length of endostaplers used, and the duration of the postoperative hospital stay between patients with staple alone and patients with SLR (4.4$\pm$1.4 vs 3.1$\pm$1.1 days in duration of drainage, 92.3$\pm$28.1 vs 71.1$\pm$30.6 mm in total length of endostaplers used, 5.9$\pm$1.9 vs 4.6$\pm$1.7 days in postoperative hospital stays, p<0.001). Conclusion: SLR was effective for preventing prolonged air leakage and responsible for shorter hospital stays after VATS-B for the treatment of spontaneous pneumothorax.

The 'Consequence Analysis' of Variables Affecting the Extent of Damage Caused by Butane Vapor Cloud Explosions (부탄가스 증기운폭발의 피해범위에 영향을 미치는 변수에 관한 고찰)

  • Char Soon-Chul;Choo Kwang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.1-7
    • /
    • 2001
  • This paper presents a 'consequence analysis' for vapor cloud explosions caused by heavy gas leakages from commercially used storage tanks at petrochemical plants. Particularly, this paper emphasizes on evaluating the results of various vapor cloud explosion accidents from Butane storage tanks. Also this paper analyses the impact of variables on the accidents in order to acquire the optimum conditions for variables. $SuperChems^{TM}$ Professional Edition was applied to analyse the impact (If atmospheric and other variables in the situation where vapor cloud continuously disperses from the ground level. Under the assumption that practical operating conditions are selected as a standard condition, and Butane leaks from the storage tank for 15 minutes, the results show that the maximum distance of LFL (Lower Flammable Limit) was 52 meters and overpressure by the vapor cloud explosion was 1 psi at 128.2 meters. It is observed that the impact of the variables on accidental Butane storage tank leakage mainly varied upon atmospheric stability, wind velocity, pipe line size, visible length, etc., and changes in the simulation result occurred as the variables varied. The maximum distance of the LFL (Lower Flammable Limit) increased as the visible length became shorter, the size of the leak became larger, the wind velocity was decreased, and the climatic conditions became more stable. Thus, by analysing the variables that influence the simulation results of explosions of Butane storage tanks containing heavy gases, I am presenting the most appropriate method for 'consequence analysis' and the selection of standards for suitable values of variables, to obtain the most optimal conditions for the best results.

  • PDF

The Effects of Additional Tetracycline Pleurodesis during Thoracoscopic Procedures for Treating Primary Spontaneous Pneumothorax (일차성 자연 기흉의 흉강경 수술 시 추가로 시행한 Textracycline 흉막 유착술의 효용)

  • Lee, Hyeon-Woong;Lee, Jae-Ik;Kim, Keun-Woo;Park, Kook-Yang;Park, Chul-Hyun;Hyun, Sung-Youl;Jeon, Yang-Bin;Choi, Chang-Hyu
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.729-735
    • /
    • 2008
  • Background: This study was performed to evaluate the safety and efficacy of performing additional tetracycline pleurodesis during the thoracoscopic treatment of primary spontaneous pneumothorax. Material and Method: Between March 2004 and December 2007, 91 cases of primary spontaneous pneumothorax were treated by video-assisted thoracoscopic surgery. The thoracoscopic procedures included resection of the blebs and mechanical pleurodesis by scrubbing the parietal pleura. For 27 cases (Tetracycline group, group I), 20 mg/kg tetracycline was instilled into the pleural space through a trocar before closing the chest. The control group (group II) consisted of 64 cases of primary spontaneous pneumothorax for which the same thoracoscopic procedures alone were performed during the same study period. Result: There was no significant difference between the two groups in terms of the demographic data, the operative findings and the operation time. The percentage of cases that needed intravenous analgesics and the duration of intravenous analgesics were comparable in both groups. There was no significant difference in the duration of air leaks and complications between the two groups. The patients treated with tetracycline pleurodesis had a longer period of postoperative chest drainage (4.2 days vs 3.5 days, respectively, p=0.03) and hospitalization (5.0 days vs 4.0 days, respectively, p=0.006). During the follow up period, the ipsilateral recurrence rate was much lower for the patients who were treated with tetracycline pleurodesis (0% vs 10.9%, respectively, p=0.099), and freedom from recurrence tended to be more favorable for group I (p=0.077), although this was not statistically significant. Conclusion: Additional tetracycline pleurodesis during thoracoscopic treatment for primary spontaneous pneumothorax caused prolongation of chest drainage and a prolonged hospital stay. However, further investigations are needed because tetracycline pleurodesis can be performed safely without serious complications and it showed a distinct tendency to reduce the rate of recurrence.

Sewer Decontamination Mechanism and Pipe Network Monitoring and Fault Diagnosis of Water Network System Based on System Analysis (시스템 해석에 기초한 하수관망 오염 매카니즘과 관망 모니터링 및 이상진단)

  • Kang, OnYu;Lee, SeungChul;Kim, MinJeong;Yu, SuMin;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.980-987
    • /
    • 2012
  • Nonpoint source pollution causes leaks and overtopping, depending on the state of the sewer network as well as aggravates the pollution load of the aqueous water system as it is introduced into the sewer by wash-off. According, the need for efficient sewer monitoring system which can manage the sewage flowrate, water quality, inflow/infiltration and overflow has increased for sewer maintenance and the prevention of environmental pollution. However, the sewer monitoring is not easy since the sewer network is built in underground with the complex nature of its structure and connections. Sewer decontamination mechanism as well as pipe network monitoring and fault diagnosis of water network system on system analysis proposed in this study. First, the pollution removal pattern and behavior of contaminants in the sewer pipe network is analyzed by using sewer process simulation program, stormwater & wastewater management model for expert (XP-SWMM). Second, the sewer network fault diagnosis was performed using the multivariate statistical monitoring to monitor water quality in the sewer and detect the sewer leakage and burst. Sewer decontamination mechanism analysis with static and dynamic state system results showed that loads of total nitrogen (TN) and total phosphorous (TP) during rainfall are greatly increased than non-rainfall, which will aggravate the pollution load of the water system. Accordingly, the sewer outflow in pipe network is analyzed due to the increased flow and inflow of pollutant concentration caused by rainfall. The proposed sewer network monitoring and fault diagnosis technique can be used effectively for the nonpoint source pollution management of the urban watershed as well as continuous monitoring system.

A Study on groundwater and pollutant recharge in urban area: use of hydrochemical data

  • Lee, Ju-Hee;Kwon, Jang-Soon;Yun, Seong-Taek;Chae, Gi-Tak;Park, Seong-Sook
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.119-120
    • /
    • 2004
  • Urban groundwater has a unique hydrologic system because of the complex surface and subsurface infrastructures such as deep foundation of many high buildings, subway systems, and sewers and public water supply systems. It generally has been considered that increased surface impermeability reduces the amount of groundwater recharge. On the other hand, leaks from sewers and public water supply systems may generate the large amounts of recharges. All of these urban facilities also may change the groundwater quality by the recharge of a myriad of contaminants. This study was performed to determine the factors controlling the recharge of deep groundwater in an urban area, based on the hydrogeochemical characteristics. The term ‘contamination’ in this study means any kind of inflow of shallow groundwater regardless of clean or contaminated. For this study, urban groundwater samples were collected from a total of 310 preexisting wells with the depth over 100 m. Random sampling method was used to select the wells for this study. Major cations together with Si, Al, Fe, Pb, Hg and Mn were analyzed by ICP-AES, and Cl, N $O_3$, N $H_4$, F, Br, S $O_4$and P $O_4$ were analyzed by IC. There are two groups of groundwater, based on hydrochemical characteristics. The first group is distributed broadly from Ca-HC $O_3$ type to Ca-C1+N $O_3$ type; the other group is the Na+K-HC $O_3$ type. The latter group is considered to represent the baseline quality of deep groundwater in the study area. Using the major ions data for the Na+K-HC $O_3$ type water, we evaluated the extent of groundwater contamination, assuming that if subtract the baseline composition from acquired data for a specific water, the remaining concentrations may indicate the degree of contamination. The remainder of each solute for each sample was simply averaged. The results showed that both Ca and HC $O_3$ represent the typical solutes which are quite enriched in urban groundwater. In particular, the P$CO_2$ values calculated using PHREEQC (version 2.8) showed a correlation with the concentrations of maior inorganic components (Na, Mg, Ca, N $O_3$, S $O_4$, etc.). The p$CO_2$ values for the first group waters widely ranged between about 10$^{-3.0}$ atm to 10$^{-1.0}$ atm and differed from those of the background water samples belonging to the Na+K-HC $O_3$ type (<10$^{-3.5}$ atm). Considering that the p$CO_2$ of soil water (near 10$^{-1.5}$ atm), this indicates that inflow of shallow water is very significant in deep groundwaters in the study area. Furthermore, the P$CO_2$ values can be used as an effective parameter to estimate the relative recharge of shallow water and thus the contamination susceptibility. The results of our present study suggest that down to considerable depth, urban groundwater in crystalline aquifer may be considerably affected by the recharge of shallow water (and pollutants) from an adjacent area. We also suggest that for such evaluation, careful examination of systematically collected hydrochemical data is requisite as an effective tool, in addition to hydrologic and hydrogeologic interpretation.ion.ion.

  • PDF

Comparison of Perception Differences About Nuclear Energy in 4 East Asian Country Students: Aiming at $10^{th}$ Grade Students who Participated in Scientific Camps, from Four East Asian Countries: Korea, Japan, Taiwan, and Singapore (동아시아 4개국 학생들의 핵에너지에 대한 인식 비교: 과학캠프에 참가한 한국, 일본, 대만, 싱가포르 10학년 학생들을 대상으로)

  • Lee, Hyeong-Jae;Park, Sang-Tae
    • Journal of The Korean Association For Science Education
    • /
    • v.32 no.4
    • /
    • pp.775-788
    • /
    • 2012
  • This study was done at a scientific camp sponsored by Nara Women's University Secondary School, Japan. In this school, $10^{th}$ grade students from 4 East Asian countries: Korea, Japan, Taiwan, and Singapore, participated. We made a research on students' perceptions about nuclear energy. Sample populations include 77 students in total, with 12 Korean, 46 Japanese, 9 Taiwanese and 10 Singaporean students. Overall perceptions comparison about nuclear energy shows average values from the order of highest Korea, Taiwan, Singapore, and to lowest, Japan. We implemented a T-test to identify perception differences about nuclear energy, with one group that include 3 countries (Korea, Taiwan and Singapore) and another group that includes all the Japanese students. T-test results of perceptions about nuclear energy shows students from the 3 countries of Korea, Taiwan and Singapore having higher average than Japanese students. (p<.05). Korean average scores regarding overall perceptions about nuclear energy show as the highest in all 4 East Asian countries and also highest in all subcategories. On the contrary in Japan, they have lower and negative perceptions of nuclear energy. In spite of these facts, perceptions of Japanese students about nuclear energy seem lowest and negative mainly because of the recent Fukushima nuclear power plant disaster, caused by the tsunami and its subsequent damages and fears of radiation leaks, etc. This shows that negative information about future disasters and its resulting damages like the Chernobyl nuclear accident could influence more on people's risk perception than general information like nuclear energy-related technologies or the news that the plant is operating normally, etc. Even if the possibility of this kind of accident is very low, just one accident could bring abnormal risks to technology itself. This strong signal makes negative image and strengthens its perceptions to the people. This could bring a stigma about nuclear energy. This study shows that Government's policy about the highest priority for nuclear energy safety is most important. As long as such perception and decision are fixed, we found that it might not be easy to get changed again because they were already fortified and maintained.

A standardized procedure on building spectral library for hazardous chemicals mixed in river flow using hyperspectral image (초분광 영상을 활용한 하천수 혼합 유해화학물질 표준 분광라이브러리 구축 방안)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.845-859
    • /
    • 2020
  • Climate change and recent heat waves have drawn public attention toward other environmental issues, such as water pollution in the form of algal blooms, chemical leaks, and oil spills. Water pollution by the leakage of chemicals may severely affect human health as well as contaminate the air, water, and soil and cause discoloration or death of crops that come in contact with these chemicals. Chemicals that may spill into water streams are often colorless and water-soluble, which makes it difficult to determine whether the water is polluted using the naked eye. When a chemical spill occurs, it is usually detected through a simple contact detection device by installing sensors at locations where leakage is likely to occur. The drawback with the approach using contact detection sensors is that it relies heavily on the skill of field workers. Moreover, these sensors are installed at a limited number of locations, so spill detection is not possible in areas where they are not installed. Recently hyperspectral images have been used to identify land cover and vegetation and to determine water quality by analyzing the inherent spectral characteristics of these materials. While hyperspectral sensors can potentially be used to detect chemical substances, there is currently a lack of research on the detection of chemicals in water streams using hyperspectral sensors. Therefore, this study utilized remote sensing techniques and the latest sensor technology to overcome the limitations of contact detection technology in detecting the leakage of hazardous chemical into aquatic systems. In this study, we aimed to determine whether 18 types of hazardous chemicals could be individually classified using hyperspectral image. To this end, we obtained hyperspectral images of each chemical to establish a spectral library. We expect that future studies will expand the spectral library database for hazardous chemicals and that verification of its application in water streams will be conducted so that it can be applied to real-time monitoring to facilitate rapid detection and response when a chemical spill has occurred.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • Fiber Technology and Industry
    • /
    • v.2 no.4
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF

The Effects of Autologous Blood Pleurodesis in the Pneumothorax with Persistent Air Leak (지속성 기흉에서 자가혈액을 이용한 흉막유착술의 효과)

  • Yoon, Su-Mi;Shin, Sung-Joon;Kim, Young-Chan;Shon, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Chung, Won-Sang;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.724-732
    • /
    • 2000
  • Background : In patients with severe chronic lung diseases even a small pneumothorax can result in life-threatening respiratory distress. It is important to treat the attack by chest tube drainage until the lung expands. Pneumothorax with a persistent air leak that does not resolve under prolonged tube thoracostomy suction is usually treated by open operation to excise or oversew a bulla or cluster of blebs to stop the air leak. Pleurodesis by the instillation of chemical agents is used for the patient who has persistent air leak and is not good candidate for surgical treatment. When the primary trial of pleurodesis with common agent fails, it is uncertain which agent should be used f or stopping the air leak by pleurodesis. It is well known that inappropriate drainage of hemothorax results in severe pleural adhesion and thickening. Based on this idea, some reports described a successful treatment with autologous blood instillation for pneumothorax patients with or without residual pleural space. We tried pleurodesis with autologous bood for pneumothorax with persistent air leak and then we evaluated the efficacy and safety. Methods : Fifteen patients who had persistent air leak in the pneumothorax complicated from the severe chronic lung disease were enrolled. They were not good candidates for surgical treatment and doxycycline pleurodesis failed to stop up their air leaks. We used a mixture of autologous blood and 50% dextrose for pleurodesis. Effect and complications were assessed by clinical out∞me, chest radiography and pulmonary function tests. Results : The mean duration of air leak was 18.4${\pm}$6.16 days before ABP (autologous blood and dextrose pleurodesis) and $5.2{\pm}1.68$ days after ABP. The mean severity of pain was $2.3{\pm}0.70$ for DP(doxycycline pleurodesis) and $1.7{\pm}0.59$ for ABDP (p<0.05). There was no other complication except mild fever. Pleural adhesion grade was a mean of $0.6{\pm}0.63$. The mean dyspnea scale was $1.7{\pm}0.46$ before pneumothrax and $2.0{\pm}0.59$ after ABDP (p>0.05). The mean $FEV_1$ was $1.47{\pm}1.01$ before pneumothorax and $1.44{\pm}1.00$ after ABDP (p>0.05). Except in 1 patient, 14 patients had no recurrent pneumothorax. Conclusion : Autologous blood pleurodesis (ABP) was successful for treatment of persistent air leak in the pneumothorax. It was easy and inexpensive and involved less pain than doxycycline pleurodesis. It did not cause complications and severe pleural adhesion. We report that ABP can be considered as a useful treatment for persistent air leak in the pneumothorax complicated from the severe chronic lung disease.

  • PDF