• Title/Summary/Keyword: leakage test

Search Result 1,010, Processing Time 0.02 seconds

A Study of Surface leakage current of AlGaN/GaN Heterostructures (AlGaN/GaN 이종접합구조의 표면누설전류에 관한 연구)

  • Seok, O-Gyun;Choi, Young-Hwan;Lim, Ji-Yong;Kim, Young-Shil;Kim, Min-Ki;Han, Min-Koo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.89-90
    • /
    • 2009
  • Three kind of surface-leakage-test-patterns were fabricated and measured in order to investigate the surface leakage current of AlGaN/GaN heterostructures through etched GaN buffer surface and mesa wall. The pattern which contain the mesa wall has the largest surface leakage current among them. The leakage current due to the mesa wall is predominant source of the leakage current of AlGaN/GaN devices.

  • PDF

Development of Leakage Detector for Electric Equipment Failure in Fountain (분수대에서의 전기설비 고장에 대한 누전 감지 장치 개발)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.35-40
    • /
    • 2018
  • This research aimed to develop an leakage detector of analyzing the electric potential generated from the electric leakage of electric equipment of the fountain. To accomplish this goal, the potential gradient was analyzed against path 1 ~ path 4; this was done by taking the lighting of a fountain as the electric leakage point based on code analyses in Korea and other countries. Lighting 1 was taken as the electric leakage point, and the earthing point was set against lightings(2~3). It appeared that the allowable touch voltage against the 1 type(under 2.5 V) exceeded 60.0%. Therefore, the lighting of fountain turned out to be the most dangerous point, and electric shock could be formed by the electric leakage of electric equipment in underwater as well as by the lighting. An leakage detector was developed based on this risk; this detector is capable of analyzing the electric potential of a electric equipments of the fountain in underwater. Then, a verification test was carried out. This leakage detector can be used to measure electric potential in various submerged areas such as swimming pools, flooded spaces, and fountains.

Performance Test of Inter-propellant Seal (추진제 혼합 방지 실의 성능시험)

  • Kwak, Hyun-D.;Jeon, Seong-Min;Kim, Jin-Han
    • Tribology and Lubricants
    • /
    • v.26 no.6
    • /
    • pp.322-328
    • /
    • 2010
  • An inter-propellant seal (IPS) for 75 ton class thrust turbopump was tested. Leakage characteristics were presented with a given range of pressure difference under cryogenic as well as room temperature conditions. For cryogenic tests, liquid nitrogen was used as analogic fluid of liquid oxygen (LOX) while water was used instead of kerosene for room temperature condition. Test results showed that IPS had satisfactory leakage performance. Additionally endurance test was conducted to prove the life time of manufactured IPS and the tested IPS had successfully survived during required life time, 2100 seconds.

Durability Properties of Liquid Phase LPG Injection System with Various Qualities of LPG Fuels (LPG연료품질에 따른 LPG액상분사방식의 내구특성연구)

  • 김창업;오승묵;강건용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.73-78
    • /
    • 2004
  • The liquid phase LPG injection (LPLi) system (the third generation technology) has been considered as one of the next generation fuel supply systems for LPG vehicles, since it has a very strong potential to accomplish the higher power, higher efficiency, and lower emission characteristics than the mixer type(the second generation technology) fuel supply system. To investigate the durability property of core part of injector in liquid phase LPG injection system, leakage test, SEM test of injectors and analysis of unvaporized fuel components with various LPG fuel qualities were tested. The experimental results showed that no serious problem in durability test using favorable LPG fuel quality, while high leakage amount due to the large scratches in the needle and nozzle of the injector were found using LPG fuel with highly containing olefin components, especially butadiene species.

Development of leakage test facility for leak signal characteristic analysis in water pipeline (상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발)

  • Park, Sanghyuk;Kwak, Philljae;Lee, Hyundong;Choi, Changho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

A STUDY ON THE MICROLEAKAGE OF RETROFILLED TEETH WITH VARIOUS MATERIALS AND INSTRUMENTS FOR CAVITY PREPARATION (역행충전시 와동형성 기구 및 수복재에 따른 변연누출에 관한 연구)

  • Lee, Jae-Yong;Cho, In-Ho;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.187-196
    • /
    • 1993
  • The purpose of this study was to evaluate the microleakage of retrofilled teeth with various materials [non-zinc Amalgam, IRM, Ketac-silver, CGP(cold-burnished, ultrafil)[and instruments for cavity preparation. Root apex were resected 2mm from apex horizontally and class I cavities were prepared in 2mm denpth, 1.5mm width and were filled with above mentioned materials. Root apex were resected 2mm from apex horizontally and class I cavities were prepared in 2mm depth, 1. 5mm width and were filled with above mentioned materials. 2% methylene blue dye solution was used for 4 days immersion and the linear leakage was measured with calipers and the volumetric leakage was determined with a spectrophotometer. The results were as follows : 1. Amalgam group showed the greatest amount of leakage and Ketac-silver group showed the least value. 2. By linear leakage test, the group retrofilled with Ketac-silver, or CGP showed better seal than the group of Amalgam or IRM. This was shown in both retrograde tip and Conventional method. 3. By volumetric leakage test, the group retrofilled with Ketac-silver showed significantly better seal than the group with IRM in retrograde tip method. 4. By volumetric leakage test, the group retrofilled with Ketac-silver showed significantly better seal than the group with Amalgam in the Conventional method.

  • PDF

Closed-Suction Drainage and Cerebrospinal Fluid Leakage Following Microvascular Decompression : A Retrospective Comparison Study

  • Kim, Young-Hoon;Han, Jung Ho;Kim, Chae-Yong;Oh, Chang Wan
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.112-117
    • /
    • 2013
  • Objective : We performed this study to investigate whether the use of closed-suction drainage following microvascular decompression (MVD) causes cerebrospinal fluid (CSF) leakage. Methods : Between 2004 and 2011, a total of 157 patients with neurovascular compression were treated with MVD. MVD was performed for hemifacial spasm in 150 (95.5%) cases and for trigeminal neuralgia in 7 (4.5%) cases. The mean age of the patients was $49.8{\pm}9.6$ years (range, 20-69). Dural substitutes were used in 44 (28.0%) patients. Ninety-two patients (58.6%) were underwent a 4-5 cm craniotomy using drainage (drainage group), and 65 (41.4%) did a small 2-2.5 cm retromastoid craniectomy without closed-suction drainage (no-drainage group). Results : Eleven (7.0%) patients experienced CSF leakage following MVD based on the criteria of this study; all of these patients were in the drainage group. In the unadjusted analyses, the incidence of CSF leakage was significantly related with the use of closed-suction drainage following MVD (12.0% in the drainage group vs. 0% in the no-drainage group, respectively; p=0.003; Fisher's exact test). Those who received dural substitutes and the elderly (cut-off value=60 years) exhibited a tendency to develop CSF leakage (p=0.075 and p=0.090, respectively; Fisher's exact test). In the multivariate analysis, only the use of closed-suction drainage was significantly and independently associated with the development of CSF leakage following MVD (odds ratio=9.900; 95% confidence interval, 1.418 to infinity; p=0.017). Conclusion : The use of closed-suction drainage following MVD appears to be related to the development of CSF leakage.

The Performance Analysis Method with New Pressure Loss and Leakage Flow Models of Regenerative Blower

  • Lee, Chan;Kil, Hyun Gwon;Kim, Kwang Yeong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.221-229
    • /
    • 2015
  • For efficient design process of regenerative blower, the present study provides new generalized pressure and leakage flow loss models, which can be used in the performance analysis method of regenerative blower. The present performance analysis on designed blower is made by incorporating momentum exchange theory between impellers and side channel with mean line analysis method, and its pressure loss and leakage flow models are generalized from the related fluid mechanics correlations which can be expressed in terms of blower design variables. The present performance analysis method is applied to four existing models for verifying its prediction accuracy, and the prediction and the test results agreed well within a few percentage of relative error. Furthermore, the present performance analysis method is also applied in developing a new blower used for fuel cell application, and the newly designed blower is manufactured and tested through chamber-type test facility. The performance prediction by the present method agreed well with the test result and also with the CFD simulation results. From the comparison results, the present performance analysis method is shown to be suitable for the actual design practice of regenerative blower.

Effect of Thermal Mechanical Stresses on Electrical Characteristics of Polymer Housed Surge Arresters (열-기계적 스트레스가 폴리머 피뢰기의 전기적 특성에 미치는 영향)

  • Cho, Han-Goo;You, Dae-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.555-560
    • /
    • 2007
  • This paper describes the results of a study on the sealing integrity of polymer housed surge arrester based on the thermal mechanical test. The polymer housed surge arrester employs silicone insulating materials for its housing, instead of the conventional porcelain housing. The polymer housed surge arresters exhibited the highest sealing integrity because it is not air volume between the FRP(fiber reinforced plastics) module and the silicone housing. In accordance, the sealing integrity of station class surge arresters is investigated with moisture ingress test. And, the influence of sealing integrity was evaluated through such as measurement of the deflection, reference voltage, leakage current. In electrical characteristics, reference voltage decreased in the range of $16.45{\sim}16.15\;kV$ with after thermal mechanical test. In contrary, despite the continued moisture ingress, the polymer housed surge arresters exhibited almost the same leakage current value and the resistive leakage current has risen slightly. As a results, It was thought that the polymer housed surge arresters shows good stability with sealing integrity.

DetGas: A Carbon Monoxide Gas Leakage Detector Mobile Application

  • Kamaruddin, Farhan Fikri Mohd;Hadiana, Ana;Lokman, Anitawati Mohd
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.59-66
    • /
    • 2021
  • Many incidents of Carbon Monoxide (CO) poisoning have occurred because of people being unaware of its presence. There are currently available systems on the market, but they are limited to measuring CO in a certain area and lack vital functions. Additionally, little to no evidence-based information on their quality was available. Thus, a mobile application for detecting CO gas leakage in a vehicle and critical features to assist victims was developed. A usability and functionality test were conducted to determine the product's quality utilizing nine usability and six functionality task scenarios (n=5). Then, a System Usability Scale test was performed to obtain system satisfaction, usability, and learnability (n=50). The usability and functionality test shows that all the tasks given for both tests were 100% successful. The overall score obtained for SUS was 71.4, which indicates good acceptance and usability. Around 20% of respondents claimed that they would need the support of a technical person to be able to use the application and that they needed to learn a lot of things before they could use the application, which indicates the overall high learnability of the application. The result provides empirical evidence that the CO gas leakage detection mobile application is successful and receives good usability, functionality, acceptability, learnability, and satisfaction assessments. DetGas could benefit automobile owners and other stakeholders by mitigating the risk and harm associated with gas leaking that exceeds the safe limit.