• 제목/요약/키워드: leakage component

검색결과 187건 처리시간 0.027초

누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향 (Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement)

  • 길경석;한주섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF

2액형 점착 실링재의 누수보수재 평가에 관한 연구 (2 Component Adhesive Leakage Repair Sealant Evaluation)

  • 조일규;김근허;오상근
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.396-403
    • /
    • 2016
  • 본 연구에서는 지하 콘크리트 구조물에 누수 발생 시 콘크리트 배면에 주입하여 보수를 시행하는 1액형 점착 실링재에 대해 알아보고 새로운 콘크리트 배면 주입재인 2액형 점착 실링재에 대한 평가를 진행하였다. 2액형 점착 실링재는 아스팔트 계열의 주제와 라텍스 계열의 증점제로 구성된 실링재이며, 주제와 증점제의 배합비에 따라 실링재의 점도편차가 크게 나타났다. 이에 주제와 증점제의 배합비를 투수시험을 통해 확인한 결과 주입성, 경제성, 성능을 고려하여 적정배합비를 6:1로 정하고 KS F 4935 평가를 진행하였다. 2액형 점착 실링재는 static mixer를 활용한 카트리지 타입의 용기를 이용하여 주입이 가능하고 KS F 4935 시험방법에 따라 평가를 진행한 결과 KS 기준을 만족하였다.

배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석 (Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

누설전류측정에 의한 피뢰기 열화진단에 있어 전원고조파의 영향 (Influence of Harmonics in Power System Voltage on Arrester Deterioration Diagnostics by Leakage Current Measurement)

  • 길경석;한주섭;주문노
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권1호
    • /
    • pp.42-46
    • /
    • 2003
  • Arresters are deteriorated by overvoltages or impulse currents, and the resistive leakage current of arresters increases as the deterioration of the arrester progresses, showing an increase in the 3$^{rd}$ harmonic component of the leakage current. In this reason, arrester diagnostic techniques based on the 3$^{rd}$ harmonic leakage current as a reference parameter of deterioration are widely used. The technique, however, includes an error due to the harmonics of power system voltage. Therefore, the influence of the harmonics on arrester diagnostics should be considered. In this paper, we designed a PSpice ZnO arrester model to simulate the influence of the voltage harmonics described above. A pure sinusoidal voltage and its the 3r harmonic voltage were applied to the model, and the leakage current components were analyzed. From the simulation results, it is confirmed that the peak value of resistive leakage current depends not only on the phase of the 3$^{rd}$ harmonic voltage but also on the magnitude of it. Consequently, the errors caused 1)y the harmonic voltage could be minimized by correcting the magnitude of leakage current upon analyzing the harmonics.cs.

유효성분 동작형 누전차단기(Igc Free ELB)의 원리 및 동작 특성 해석 (Analysis of the Principle and Operation Characteristics of an (Igc-Free ELB) Operated by an Active Component)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.456-461
    • /
    • 2010
  • This study compares the criteria of earth leakage breakers (ELB) and analyzes the characteristics of an Igc-free ELB operated by an active component which is not misoperated by capacitive current. Even for the same ELB, the earth leakage current flowing through the human body is estimated to be differ greatly depending on the power source, voltage, location and status of contact, contact time duration, etc. Earth leakage breakers are classified based on the rated voltage, rated sensing current, rated operating time etc. Mounting and demounting of the existing equipment can be performed easily since an $I_{gc}$-free ELB is manufactured with the same structure as a conventional ELB. The rated operating current of a conventional and an $I_{gc}$-free ELB is 30mA, the sensing current is 25mA and the rated non-operating current is 15mA. In the analysis of non-operating current characteristics, the rated non-operating current of 15mA was satisfied up to a 20mA charging current in the conventional ELB, but does not satisfy the rated non-operating current as it operates when the resistive leakage current is lower than 15mA for a charging current exceeding 20mA. Also, the ELB is misoperated without a resistive leakage current when the charging current exceeded 25mA. However, the newly developed $I_{gc}$-free ELB satisfied the rated non-operating current even when the charging current was 60mA. Also, in comparison to the interrupting characteristics, it was confirmed that the charging current satisfying the rated non-operating current of the $I_{gc}$-free ELB was three times higher than that of the conventional ELB.

월성1호기 계속운전 관련 결함연료위치탐지계통 배관의 열화관리평가 (Assessment on Aging Management of Delayed Neutron Monitoring System Tubing for Continued Operation of Wolsong Unit 1)

  • 송명호;김홍기;이영호
    • 한국압력기기공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.14-20
    • /
    • 2011
  • The end of design lifetime for Wolsong unit 1 will be reached on 20th November in 2012. So the license renewal documents for the continuous operation of Wolsong unit 1 is under reviewing now. Major components of primary system such as pressure tubes, feeder pipes including delayed neutron monitoring system tubing are being replaced and many components of secondary system are also being repaired. In this paper, the assessment on the wear degradation of delayed neutron monitoring system tubing(on the other hand, DN tube was called) was performed for the ageing management of the same component. The wear defects of this component was one of causes that resulted in heavy water leakage accidents. Therefore design specifications of Wolsong uint 1 and heavy water leakage accidents of pressurized heavy water reactors were reviewed and causes of wear defect for DN tubes were analyzed. Wear propagation equations based on the heavy water leakage history were made and the proper repairing time was possible to be expected if the continued operation was considered. Finally design change items of DN tubes that were conducted for the long term operation of Wolsong unit 1 are introduced.

익단간극이 원심압축기 성능에 미치는 영향에 관한 수치해석적 연구 (Numerical Study on Tip Clearance Effect on Performance of a Centrifugal Compressor)

  • 음학진;강신형
    • 대한기계학회논문집B
    • /
    • 제27권3호
    • /
    • pp.389-397
    • /
    • 2003
  • Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASC flow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on Performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected Performance equally. while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully.

상수관망 블록의 대표적인 용수사용 유형에 대한 최소 용수사용 시간의 결정 (Determining the Time of Least Water Use for the Major Water Usage Types in District Metered Areas)

  • 박수완;정소연
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.415-425
    • /
    • 2015
  • Aging water pipe networks hinder efficient management of important water service indices such as revenue water and leakage ratio due to pipe breakage and malfunctioning of pipe appurtenance. In order to control leakage in water pipe networks, various methods such as the minimum night flow analysis and sound waves method have been used. However, the accuracy and efficiency of detecting water leak by these methods need to be improved due to the increase of water consumption at night. In this study the Principal Component Analysis (PCA) technique was applied to the night water flow data of 426 days collected from a water distribution system in the interval of one hour. Based on the PCA technique, computational algorithms were developed to narrow the time windows for efficient execution of leak detection job. The algorithms were programmed on computer using the MATLAB. The presented techniques are expected to contribute to the efficient management of water pipe networks by providing more effective time windows for the detection of the anomaly of pipe network such as leak or abnormal demand.

Single-Phase Transformerless PV Power Conditioning Systems with Low Leakage Current and Active Power Decoupling Capability

  • Nguyen, Hoang Vu;Park, Do-Hyeon;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.997-1006
    • /
    • 2018
  • This paper proposes a transformerless photovoltaic (PV) power converter system based on the DC/AC boost inverter, which can solve the leakage current and second-order ripple power issues in single-phase grid-connected PV inverters. In the proposed topology, the leakage current can be decreased remarkably since most of the common-mode currents flow through the output capacitor, by-passing parasitic capacitors, and grounding resistors. In addition, the inherent ripple power component in the single-phase grid inverter can be suppressed without adding any extra components. Therefore, bulky electrolytic capacitors can be replaced by small film capacitors. The effectiveness of the proposed topology has been verified by simulation and experimental results for a 1-kW PV PCS.

절연물의 초기사고 감지를 위한 누설 임펄스 전류의 해석 (Analysis of the Leakage Impulse Current in Faulty Insulators for Detection of Incipient Failures)

  • 김창종;이흥재;신정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.390-398
    • /
    • 2000
  • Leakage impulse current of the contaminated insulators by using experiment data were studied. The impulse current in phase-time relationship was analyzed on line post insulators. Also, frequency components and crest factor of the leakage current were investigated to provide a scheme for an early detection of insulator incipient failure. The study shows that the phase-time characteristic is non-stationary and random and, non-harmonic component and crest factor can be promising parameters for detecting insulator leakage currents.

  • PDF