• 제목/요약/키워드: lead metal

검색결과 1,166건 처리시간 0.026초

고출력 레이저에 의한 이종금속 용접특성 (Welding characteristics of Dissimilar Metal by High Power Laser)

  • 신호준;유영태;임기건;안동규
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.250-256
    • /
    • 2004
  • For many years and primarily for economical reasons, Dissimilar Metal Welds have been used as transition joints in a variety of equipment and applications. But Dissimilar Metal Welds have several fabrication and metallurgical drawbacks that can often lead to in-service failures. In this paper, the laser weldability of STS304 stainless steel and SM45C at dissimilar metal welds using a continuous wave Nd:YAG laser are experimentally investigated. An experimental study was conducted to determine effects of welding parameters, on eliminating or reducing the extent welding zone formation at dissimilar metal welds and to optimize those parameters that have the most influence parameters such as focus length, power, beam speed, shielding gas, and wave length of laser were tested.

  • PDF

Lead Poisoning: Historical Aspects of a Paradigmatic "Occupational and Environmental Disease"

  • Riva, Michele Augusto;Lafranconi, Alessandra;D'orso, Marco Italo;Cesana, Giancarlo
    • Safety and Health at Work
    • /
    • 제3권1호
    • /
    • pp.11-16
    • /
    • 2012
  • Lead poisoning is one of the earliest identified and most known occupational disease. Its acute effects have been recognized from antiquity when this condition principally afflicted manual workers and slaves, actually scarcely considered by the medicine of that time. The Industrial Revolution caused an epidemic of metal intoxication, urging scientists and physician of that period to study and identify specific symptoms and organ alterations related to chronic lead poisoning. During the 20th century, the acknowledgment of occupational and environmental toxicity of lead fostered public awareness and legislation to protect health. More recently, the identification of sub-clinical effects have greatly modified the concept of lead poisoning and the approaches of medicine towards this condition. Nowadays, lead poisoning is rarely seen in developed countries, but it still represents a major environmental problem in certain areas. Consequently, it may appear as a paradigm of "occupational and environmental disease," and the history of this condition seems to parallel the historical development of modern "Occupational and Environmental Health" as a more complete medical discipline.

중금속의 위해성 평가에 관한 연구 (A Study on Risk Analysis of Heavy Metals)

  • 김종석;안승구
    • 한국대기환경학회지
    • /
    • 제8권4호
    • /
    • pp.269-276
    • /
    • 1992
  • 인체에 영향을 미치는 중금속은 대개 환경중에서 음식물, 공기, 먼지 및 음료수를 통하여 축적된다. 본 연구는 중금속중 납이 인체에 미치는 유해정도를 평가하기 위하여 서울과 여주등 대기중 납농도가 차이가 나는 지역주민들의 혈액중 납농도를 측정하여 Bio kinetic Model을 이용 납에 대한 인체의 위해성 정도를 알아보았으며 그 결과는 다음과 같다. - 지역별로는 혈액중 납농도가 별다른 차이를 보이지 않았으나 나이와 성별에 따라서는 다소 차이가 나고 있다. - 또한 혈액중 납농도는 log normal 분포를 나타내고 있음. - 기하표준편차는 1.2 $\sim$ 1.3 정도의 값으로 미국 EPA에서 추정한 1.31 $\sim$ 1.41의 값보다 약간 적은 값을 나타냈다.

  • PDF

탄광부 진폐증자의 혈액 중 납, 철 및 아연 농도 (Concentrations of lead, iron, and zinc in blood of coal wokers' pneumoconiosis patients)

  • 최호춘;정호근;김해정
    • Journal of Preventive Medicine and Public Health
    • /
    • 제22권4호
    • /
    • pp.486-494
    • /
    • 1989
  • Lead, iron, and zinc concentrations in whole blood were determined by atomic absorption spectrophotometry, using a simple one-step dilution procedure, which were measured in 3 groups, 98 officers unexposed to dust or to metal, 58 coal miners without pneumoconiosis, and 113 coal workers' pneumoconiosis (CWP) patients. The results were as follows : 1. The precisions (C. V.%) of lead, iron, and zinc in blood were $12.65{\pm}6.95%,\;1.47{\pm}1.25%\;and\;6.35{\pm}3.34%$, respectively. 2. Lead and zinc in blood showed the log-normal distribution unlike iron in blood which showed normal distribution. 3. Lead, iron, and zinc concentrations in blood of 3 groups were follows : There was significant difference of concentration for zinc in blood by groups statistically. 4. The difference of lead, iron, and zinc concentrations in blood was not significant (p>0.05) by profusion on chest radiographs.

  • PDF

Metal Recycling Technologies from Fly-Ashes by the Metal Mining Agency of Japan

  • Kazuyuki, Kikuta;Nobuyuki, Masuda;Nobuyuki, Okamoto;Eiichi, Arai;Junichi, Kobayashi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.659-663
    • /
    • 2001
  • In Japan, the municipal solid waste, which amounts to 50 million tons, is generated every year and most of it is incinerated. The bottom and fly ashes are disposed to the registered disposal areas under the provisions of The Waste Disposal and Public Cleaning Law. Especially, as the fly ash from the municipal waste incineration (the primary fly ash) contains heavy metals (lead, zinc, etc) and dioxins, it cannot be disposed directly without decontamination, such as moiling, cementation, chelating and dissolving processes provided in the law. However, these procedures for decontamination, except melting, are not enough for dioxins. Even in case of melting, the fly ash from the process (the secondary fly ash) contains high concentration of heavy metals (e.g., Zn; 1-20%, Pb; 1-10%). For these reasons, Metal Mining Agency of Japan (MMAJ), a governmental organization, started a four-year project to develop the treatment technologies of these fly ashes in 1999. The purpose of the project is to establish the integrated technologies to recover the valuable metals from, and to decontaminate, the primary and secondary fly-ashes in the practical scale by utilizing the existing metallurgical processes and facilities, along with the energy saving and the reduction of the environmental impact.

  • PDF

In Vivo Effects of Lead on Erythrocytes Following Chronic Exposure through Drinking Water

  • Lee, Moo-Yeol;Shin, Jung-Hun;Han, Hee-Shim;Chung, Jin-Ho
    • Archives of Pharmacal Research
    • /
    • 제29권12호
    • /
    • pp.1158-1163
    • /
    • 2006
  • More than 95% of lead, a environmental heavy metal, entering into blood accumulates in erythrocytes suggesting erythrocytes as an important target of lead toxicity. Recent studies reported that erythrocytes could contribute to blood coagulation via phosphatidylserine (PS) exposure in erythrocytes. However, in vivo effects of chronic lead exposure especially by drink-ing water on procoagulant activity of erythrocytes have not been studied yet. In the present study, we investigated the effects of chronic exposure of lead by drinking water on erythrocytes in rats. Groups of 40 male rats were provided with drinking water containing various concentrations of lead for 4 weeks and complete blood cell count, procoagulant activities of erythrocytes and platelets were evaluated with basic inspections on body weight and food/water consumption. The administration of lead containing drinking water increased the blood lead level (BLL) in a dose-dependent manner up to $22.39{\pm}2.26\;{\mu}g/dL$. Water consumption was significantly decreased while food consumption or body weight gain was not affected. In contrast to the previous findings with acute lead exposure, chronic lead exposure failed to increase PS exposure in erythrocytes with statistical significance although some trends of enhancement were observed. It implies that a certain adaptation might have happened in body during repeated exposure to lead, resulting in attenuation of PS exposure. With this study, we believe that a valuable information was provided for the study on the toxicological significance and the risk assessment of lead contaminated drinking water.

재활용 현황파악을 위한 공공 자료별 국내 납 물질 흐름 상호 확인 (A Cross-check of Domestic Lead Material Flow in Public Database Sets for the Recycling Status Analysis)

  • 이상훈;김정은
    • 자원리싸이클링
    • /
    • 제30권3호
    • /
    • pp.63-69
    • /
    • 2021
  • 폐기물에서의 납 회수 및 재활용을 통해 원료공급 안정화와 환경오염 예방을 동시에 도모할 수 있고 실제로도 최근 폐납축전지 위주의 재활용을 통해 납 원자재 공급 측면에서 긍정적인 효과를 보고 있다. 다만 향후 납 회수 및 재활용의 효과를 극대화하기 위해서 납의 물질 흐름의 현황을 효과적으로 파악할 필요가 있는데, 배출원 등의 복잡성과 다양성으로 인해 관련 조사가 번거로울 수 있다. 이 경우 편의상 인터넷 공개자료를 통한 예비 조사의 선수행이 효과적일 수 있다. 따라서, 본 연구에서는 공공기관 공개자료를 통해 국내 납의 흐름을 파악하여 향후 납 회수/재활용에 효율성을 기여하고자 한다. 이에 본 연구에서는 UN Comtrade와 국내 화학물질배출×이동량 사이트 자료를 이용하여 납의 수입량 및 배출×이동량을 파악하고 이를 국가통합자원관리시스템에서 제시된 납의 흐름과 비교하였다. 그 결과 폐납축전지 등 주요 항목별 관련 납의 흐름이 각 사이트 간에 대략적인 일치를 보였다.

Isolation and Characterization of Pb-Solubilizing Bacteria and Their Effects on Pb Uptake by Brassica juncea: Implications for Microbe-Assisted Phytoremediation

  • Yahaghi, Zahra;Shirvani, Mehran;Nourbakhsh, Farshid;de la Pena, Teodoro Coba;Pueyo, Jose J.;Talebi, Majid
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권7호
    • /
    • pp.1156-1167
    • /
    • 2018
  • The aim of this study was to isolate and characterize lead (Pb)-solubilizing bacteria from heavy metal-contaminated mine soils and to evaluate their inoculation effects on the growth and Pb absorption of Brassica juncea. The isolates were also evaluated for their plant growth-promoting characteristics as well as heavy metal and salt tolerance. A total of 171 Pb-tolerant isolates were identified, of which only 15 bacterial strains were able to produce clear haloes in solid medium containing PbO or $PbCO_3$, indicating Pb solubilization. All of these 15 strains were also able to dissolve the Pb minerals in a liquid medium, which was accompanied by significant decreases in pH values of the medium. Based on 16S rRNA gene sequence analysis, the Pb-solubilizing strains belonged to genera Bacillus, Paenibacillus, Brevibacterium, and Staphylococcus. A majority of the Pb-solubilizing strains were able to produce indole acetic acid and siderophores to different extents. Two of the Pb-solubilizing isolates were able to solubilize inorganic phosphate as well. Some of the strains displayed tolerance to different heavy metals and to salt stress and were able to grow in a wide pH range. Inoculation with two selected Pb-solubilizing and plant growth-promoting strains, (i.e., Brevibacterium frigoritolerans YSP40 and Bacillus paralicheniformis YSP151) and their consortium enhanced the growth and Pb uptake of B. juncea plants grown in a metal-contaminated soil. The bacterial strains isolated in this study are promising candidates to develop novel microbe-assisted phytoremediation strategies for metal-contaminated soils.

Characteristics of electrically conductive adhesives filled with silver-coated copper

  • Nishikawa, Hiroshi;Terad, Nobuto;Miyake, Koich;Aoki, Akira;Takemoto, Tadashi
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.217-220
    • /
    • 2009
  • Conductive adhesives have been investigated for use in microelectronics packaging as a lead-free solder substitute due to their advantages, such as low bonding temperature. However, high resistivity and poor mechanical behavior may be the limiting factors for the development of conductive adhesives. The metal fillers and the polymer resins provide electrical and mechanical interconnections between surface mount device components and a substrate. As metal fillers used in conductive adhesives, silver is the most commonly used due to its high conductivity and the stability. However the cost of conductive adhesives with silver fillers is much higher than usual lead-free solders and silver has poor electro-migration performance. So, copper can be a promising candidate for conductive filler metal due to its low resistivity and low cost, but oxidation causes this metal to lose its conductivity. In this study, electrically conductive adhesives (ECAs) using surface modified copper fillers were developed. Especially, in order to overcome the problem associated with the oxidation of copper, copper particles were coated with silver, and the silver-coated copper was tested as a filler metal. Especially the effect of silver coating on the electrical resistance just after curing and after aging was investigated. As a result, it was found that the electrical resistance of ECA with silver-coated copper filler was clearly lower and more stable than that of ECA with pure copper filler after curing process. And, during high temperature storage test, the degradation rate of electrical resistance for ECA with silver coated copper filler was quite slower than that for ECA with pure copper filler.

  • PDF