The Effect of Occupational Health Service on the Improvement of Worker’s Health in a Lead Using Industry (모연취급 사업장에서의 산업보건사업이 근로자 건강증진에 미치는 효과)

  • Lee, Byeong-Guk;Lee, Gwang-Muk;An, Gyu-Dong
    • 산업보건소식
    • /
    • no.46
    • /
    • pp.3-13
    • /
    • 1987
  • For the purpose of investigating the effect of occupational health service in terms of environmental control and health provision of workers on the improvement of worker's health, authors analysed the data of environmental measurement and health check-up of one lead using industry who started his investment to environmental improvement from 1980. Six hundred million won was invested for environmental improvement from 1980 to 1986. This investment brought about apparent improvement of working conditions of all of the workplaces from mean concentration of lead in air over 0.15mg/$m^3$ 1981 to mean concentration of lead in air less than 0.15mg/$m^3$. Environmental control reduced mean blood lead level from 51.2 $\pm$ 11.5ug/이 in 1983 to 39.2 $\pm$ 16.0ug/dl in 1986, and delta-aminolevulinic acid concentration 3.15 $\pm$ 2.1mg/l in 1982 to 1.96 $\pm$ 1. 7mg/l in 1986, respectively. Blood ZPP levels were decreased from 76.1 $\pm$ 58.9ug/dl in 1983 to 42.23 $\pm$ 30.3ug/dl in 1986. If 150ug/dl of blood ZPP is considered as unacceptable limit of lead intoxication, more than 10 percent of workers belonged to this category in 1983, but only 0.5 of workers showed their blood ZPP level over the 150ug/dl in 1986 It was observed that no workers whose work duration were less than one year showed their blood ZPP level over 100ug/dl, but there were high percentages of lead workers with high blood ZPP (over 150 ug/dl) who were working in uncontrolled had working condition and whose work duration were less than one year.

  • PDF

Bioaccumulation Patterns and Responses of Fleece-flower; Persicaria thunbergii to Cadmium and Lead

  • Kim, In-Sung;Kyung Hong kang;Lee, Eun-Ju
    • 한국생태학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.119-125
    • /
    • 2002
  • Application of phytoremediation in the polluted area to remove undesirable materials is a complex and difficult subject without detailed investigation and experimentation. We investigated the accumulation patterns of cadmium and lead in plants naturally grown, the bioavailability of plants to accumulate these toxic metals and the responses of P. thunbergii to cadmium and lead. The soil samples contained detectable lead (<17.5$\mu\textrm{g}$/g), whereas cadmium was not detected in the soils of study area. The whole body of Persicaria thunbergii contained detectable lead (<320.8$\mu\textrm{g}$/g) but cadmium was detected only in the stem (<7.4$\mu\textrm{g}$/g) and root (<10.4$\mu\textrm{g}$/g) of P. thunbergii. Cadmium was not detected in Trapa japonica and Nymphoides peltata, whereas lead was detected in T. japonica (<323.7$\mu\textrm{g}$/g) and N. peltata (<177.5$\mu\textrm{g}$/g). Correlation coefficient between lead content in soil and in these plant samples represented positive correlation. The total content of lead in each plant sample increased in the order of N.peltata$\leq$P.thunbergii

  • PDF

Bioaccumulation Patterns and Responses of Fleece-flower; Persicaria thunbergii to Cadmium and Lead

  • Kim, In Sung;Kang, Kyung Hong;Lee, Eun Ju
    • The Korean Journal of Ecology
    • /
    • v.25 no.4
    • /
    • pp.253-259
    • /
    • 2002
  • Application of phytoremediation in the polluted area to remove undesirable materials is a complex and difficult subject without detailed investigation and experimentation. We investigated the accumulation patterns of cadmium and lead in plants naturally grown, the bioavailability of plants to accumulate these toxic metals and the responses of P. thunbergii to cadmium and lead. The soil samples contained detectable lead (<$17.5_\mu$g/g), whereas cadmium was not detected in the soils of study area. The whole body of Persicaria thunbergii contained detectable lead (<320.$8_\mu$g/g/g) but cadmium was detected only in the stem (<7.$4_\mu$g/g/g) and root (<10.$4_\mu$g/g/g) of P. thunbergii. Cadmium was not detected in Trapa japonica and Nymphoides peltata, whereas lead was detected in T. japonica (<323.$7_\mu$g/g/g) and N. peltata (<177.$5_\mu$g/g/g). Correlation coefficient between lead content in soil and in these plant samples represented positive correlation. The total content of lead in each plant sample increased in the order of N. peltata$\leq$P. thunbergii

System Configuration of Ultrasonic Nuclear Fuel Cleaner and Quantitative Weight Measurement of Removed CRUD (초음파 핵연료 세정장비의 시스템 구성과 제거된 크러드의 정량적 무게 측정법)

  • Jung Cheol Shin;Hak Yun Lee;Un Hak Seong;Yeong Jong Joo;Yong Chan Kim;Wook Jin Han
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • Crud is a corrosion deposit that forms in equipments and piping of nuclear reactor's primary systems. When crud circulates through the reactor's primary system coolant and adheres to the surface of the nuclear fuel cladding tube, it can lead to the Axial Offset Anomaly (AOA) phenomenon. This occurrence is known to potentially reduce the output of a nuclear power plant or to necessitate an early shutdown. Consequently, worldwide nuclear power plants have employed ultrasonic cleaning methods since 2000 to mitigate crud deposition, ensuring stable operation and economic efficiency. This paper details the system configuration of ultrasonic nuclear fuel cleaning equipment, outlining the function of each component. The objective is to contribute to the local domestic production of ultrasonic nuclear fuel cleaning equipment. Additionally, the paper introduces a method for accurately measuring the weight of removed crud, a crucial factor in assessing cleaning effectiveness and providing input data for the BOA code used in core safety evaluations. Accurate measurement of highly radioactive filters containing crud is essential, and weighing them underwater is a common practice. However, the buoyancy effect during underwater weighing may lead to an overestimation of the collected crud's weight. To address this issue, the paper proposes a formula correcting for buoyancy errors, enhancing measurement accuracy. This improved weight measurement method, accounting for buoyancy effects in water, is expected to facilitate the quantitative assessment of filter weights generated during chemical decontamination and system operations in nuclear power plants.

Direct Measurement of Blast Pressure in Near Field with Lead Plate Blast Pressure Meter (Lead Plate Blast Pressure Meter를 이용한 근거리 기폭의 발파압 계측)

  • Ko, Young-Hun;Jang, Hyong-Doo;Yang, Hyung-Sik
    • Tunnel and Underground Space
    • /
    • v.22 no.1
    • /
    • pp.54-59
    • /
    • 2012
  • Deformation of Lead plate blast pressure meter were measured after they were exposed to surface blasting. Blasting pressure was determined by comparing the data with calibration graph which was drawn from the laboratory experiments with gas gun of Hopkinson bar tester. The results were compared with calculated values from the equations of CONWEP (Conventional Weapons Effects Program) and DDESB (Department of Defence Explosives Safety Board). Measured values were lower than calculated values in near field. Gradual decaying tendency of the pressure was observed. It means that estimated blasting pressure of very near field with theoretical equations can be uncertain.

CC-CV Charging Time Characteristics of Lead-Acid Batteries Based on Compact Estimation Model (간결한 예측 모형에 기반한 납축전지의 정전류-정전압 충전시간 특성화)

  • Han, Jeong-gyeon;Shin, Donghwa
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.5
    • /
    • pp.305-312
    • /
    • 2016
  • Modern embedded systems are typically operated by the rechargeable batteries in our daily life. Since charge of batteries is considered as an time consuming task, there have been extensive efforts to manage the charge time from the perspective of materials, circuits, and systems. Estimation of battery charge time is one of the essential information to design the charge circuitry. A compact macro model for the constant-current and constant-voltage charge protocol was recently introduced, which gives us a quick estimation of charge time with similar shape to the famous Peukert's law for discharge time estimation. The CC-CV charging protocol is widely used for Lithium-based batteries and Lead-acid batteries. In this paper, we characterize the lead-acid battery by measurement to extract the model coefficients, which was not covered by the previous studies. By our proposed model, the key coefficient Kcc results in 1.18-1.31, which is little bit higher than that of Lithium batteries. The accuracy of our model is within the range of ${\pm}10%$ error, which is compatible with the other studies such as Peukert's law.

Electroplating on the Lead Frames Fabricated from Domestic Copper Plate (국산동판을 사용한 리드프레임 도금기술에 관한 연구)

  • Jang, Hyeon-Gu;Lee, Dae-Seung
    • Journal of the Korean institute of surface engineering
    • /
    • v.19 no.3
    • /
    • pp.92-108
    • /
    • 1986
  • An electroplating on the lead frame fabricated from domestic copper plate was studied experimentally. In this study, nickel was plated on the thin copper lead frame and silver layer was coated on the nickel film in the cyanide electrolyte. The effect of process variables such as current density, plating time, coating thickness and flow rate of electrolytic solution on the properties of coating was investigated. Some samples on each step were fabricated during electroplating. The results obtained from polarization measurement, observation of SEM photograph, adhesion test of coating and microhardness test are as follows. On silver plating, polarization resistance of potentiostatic cathodic polarization curve is reduced as the flow rate of Ag electrolytic solution increases. And above resistance is also reduced when the minor chemicals of sodium cyanide and sodium carbonate are added in potassium silver cyanide bath. The reduced polarization resistance makes silver deposition on the cathode easy. An increase in the current density and the coating thickness causes the particle size of deposit to coarsen, and consequently the Knoop microhardness of the coating decreases. On selective plating an increase in the flow rate of plating solution lead to do high speed plating with high current density. In this case, the surface morphology of deposit is of fine microstructure with high Knoop hardness. An increasing trend of the adhesion of coating was shown with increasing the current density and flow rate of electrolytic solution.

  • PDF

Direct Measurement of Diffusion Length in Mixed Lead-halide Perovskite Films Using Scanning Photocurrent Microscopy

  • Kim, Ahram;Son, Byung Hee;Kim, Hwan Sik;Ahn, Yeong Hwan
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.514-518
    • /
    • 2018
  • Carrier diffusion length in the light-sensitive material is one of the key elements in improving the light-current conversion efficiency of solar-cell devices. In this paper, we measured the carrier diffusion length in lead-halide perovskite ($MAPbI_3$) and mixed lead-halide ($MAPbI_{3-x}Cl_x$) perovskite devices using scanning photocurrent microscopy (SPCM). The SPCM signal decreased as we moved the focused laser spot away from the metal contact. By fitting the data with a simple exponential curve, we extracted the carrier diffusion length of each perovskite film. Importantly, the diffusion length of the mixed-halide perovskite was higher than that of the halide perovskite film by a factor of 3 to 6; this is consistent with the general expectation that the carrier mobility will be higher in the case of the mixed lead-halide perovskites. Finally, the diffusion length was investigated as a function of applied bias for both samples, and analyzed successfully in terms of the drift-diffusion model.

Relationship of between blood lead level and lead related symptoms in low level lead exposure (저농도 연폭로에서 혈중 연농도와 자각증상과의 관계)

  • Hwang, Kyu-Yoon;Ahn, Jae-Eog;Ahn, Kyu-Dong;Lee, Byung-Kook;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.2 s.34
    • /
    • pp.181-194
    • /
    • 1991
  • This study intended to obtain an useful information on the prevalence of subjective symptoms, and to clarify the interrelationships between blood lead and lead related symptoms in low level lead exposure. The 93 male workers exposed to lead and 56 male nonexposed workers were examined for their blood lead(PBB), Zinc-protoporphy(ZPP), hemoglobin(HB) and personnal history, and completed 15 questionnaires related to symptoms of lead absorption : also measured lead concentration in air (PBA) in the workplace. The results obtained were as follows ; 1. The means of blood lead (PBB), blood ZPP and hemoglobin (HB) among workers exposed to lead were $26.1{\pm}8.8{\mu}g/dl,\;28.3{\pm}26.0{\mu}g/dl$ and $16.2{\pm}1.2g/dl$ : whereas those of nonexposed workers were $18.7{\pm}5.1{\mu}g/dl,\;20.6{\pm}8.7{\mu}g/dl$ and $17.3{\pm}1.1g/dl$. The means of above three indicies between two groups showed significant difference statistically (p<0.05). 2. The means of blood lead (PBB), blood ZPP and hemoglobin of workers exposed .to different lead concentration in air were as follows : When it was below $25{\mu}g/m^3$, the indices were $24.7{\pm}79,\;26.1{\pm}26.8{\mu}g/dl\;and\;16.4{\pm}1.1g/dl$ respectively : These indices were $27.1{\pm}8.5,\;23.9{\pm}10.92{\mu}g/dl\;and\;16.2{\pm}1.3g/dl$ when the lead concentration in air was $25{\sim}50{\mu}g/m^3$ : and they were $3.4{\pm}9.3,\;42.3{\pm}31.3{\mu}g/dl\;and\;15.5{\pm}1.2g/dl$ when the concentration of lead was above $50{\mu}g/m^3$. Although there were statistical difference in blood lead and hemoglobin among three different lead concentration in air, there was no statistical difference of blood ZPP among the three groups with different exposure levels (p>0.05). 3. The most frequent by complained symptom was 'Generalized weakness and fatigue', and fewest symptom was 'Intermittent pains in abdomen' 4. Only two symptoms out of fifteen symptoms checked by themselves revealed significant difference between exposed and nonexposed groups. These were 'Intermittent pains of abdomen' and 'Joint pain or arthralgia' (p<0.05), No positive correlation was found between the levels of blood lead and symptom groups categorized as gastrointestinal, neuromuscular and constitutional symptoms, 5. Blood lead (r=0.3995) and ZPP (r=0.2837) showed statistically significant correlation with mean lead concentration in air, whereas correlations were not demonstrated between blood lead and lead related symptoms or blood ZPP and lead related symptoms. 6. Blood lead (PBB) and ZPP showed association (r=0.2466) and the equation PBB=23.75+0.0842 ZPP was derived. 7. On stepwise multiple regression, using blood lead level as a dependent variable and ZPP, hemoglobin (HB), age, work duration (WD) and symptom prevalence as a independent variables, only ZPP significantly contributed a lot to blood lead level. 8. While the ZPP measurement was found to be a good indicator in evaluating health effect of lead absorption in low level lead exposure, lead related symptoms were not sensitive enough to evaluate of lead absorption in low level exposure.

  • PDF