• Title/Summary/Keyword: lead(II)

Search Result 524, Processing Time 0.03 seconds

A Study on Activation Characteristics Generated by 9 MeV Electron Linear Accelerator for Container Security Inspection (컨테이너 보안 검색용 9 MeV 전자 선형가속기에서 발생한 방사화 특성평가에 관한 연구)

  • Lee, Chang-Ho;Kim, Jang-Oh;Lee, Yoon-Ji;Jeon, Chan-Hee;Lee, Ji-Eun;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.563-575
    • /
    • 2020
  • The purpose of this study is to evaluate the activation characteristics that occur in a linear accelerator for container security inspection. In the computer simulation design, first, the targets consisted of a tungsten (Z=74) single material target and a tungsten (Z=74) and copper (Z=29) composite target. Second, the fan beam collimator was composed of a single material of lead (Z=82) and a composite material of tungsten (Z-74) and lead (Z=82) depending on the material. Final, the concrete in the room where the linear accelerator was located contained magnetite type and impurities. In the research method, first, the optical neutron flux was calculated using the MCNP6 code as a F4 Tally for the linear accelerator and structure. Second, the photoneutron flux calculated from the MCNP6 code was applied to FISPACT-II to evaluate the activation product. Final, the decommissioning evaluation was conducted through the specific activity of the activation product. As a result, first, it was the most common in photoneutron targets, followed by a collimator and a concrete 10 cm deep. Second, activation products were produced as by-products of W-181 in tungsten targets and collimator, and Co-60, Ni-63, Cs-134, Eu-152, Eu-154 nuclides in impurity-containing concrete. Final, it was found that the tungsten target satisfies the permissible concentration for self-disposal after 90 days upon decommissioning. These results could be confirmed that the photoneutron yield and degree of activation at 9 MeV energy were insignificant. However, it is thought that W-181 generated from the tungsten target and collimator of the linear accelerator may affect the exposure when disassembled for repair. Therefore, this study presents basic data on the management of activated parts of a linear accelerator for container security inspection. In addition, When decommissioning the linear accelerator for container security inspection, it is expected that it can be used to prove the standard that permissible concentration of self-disposal.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Cohort Observation of Blood Lead Concentration of Storage Battery Workers (축전지공장 근로자들의 혈중 연농도에 대한 코호트 관찰)

  • Kim, Chang-Yoon;Kim, Jung-Man;Han, Gu-Wung;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.324-337
    • /
    • 1990
  • To assess the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, 156 workers (116 exposed subjects and 40 controls) of a newly established battery factory were examined for their blood lead concentration (Pb-B) in every 3 months up to 18 months. Air lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean Pb-B of the controls was $21.97{\pm}3.36{\mu}g/dl$ at the preemployment examination and slightly increased to $22.75{\pm}3.38{\mu}g/dl$ after 6 months. Mean Pb-B of the workers who were employed before the factory was in operation (Group A) was $20.49{\pm}3.84{\mu}g/dl$ on employment and it was increased to $23.90{\pm}5.30{\mu}g/dl$ after 3 months (p<0.01). Pb-B was increased to $28.84{\pm}5.76{\mu}g/dl$ 6 months after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $26.83{\mu}g/dl\;and\;28.28{\mu}g/dl$ in the subsequent 4 tests. Mean Pb-B of the workers who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $16.58{\pm}4/53{\mu}g/dl$ before the exposure and it was increased to $28.82{\pm}5.66{\mu}g/dl$(P<0.01) in 3 months later (1 month after the intervention). The values of subsequent 4 tests remained between 26.46 and $28.54{\mu}g/dl$. Mean Pb-B of the workers who were employed after intervention program had been started (Group C) was $19.45{\pm}3.44{\mu}g/dl$ at the preemployment examination and gradually increased to $22.70{\pm}4.55{\mu}g/dl$ after 3 months(P<0.01), $23.68{\pm}4.18{\mu}g/dl$ after 6 months, and $24.42{\pm}3.60{\mu}g/dl$ after 9 months. Work stations were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3\;and\;0.208mg/m^3$ in follow-up tests. The Pb-A of part II was decreased from $0.232mg/m^3\;to\;0.148mg/m^3,\;and\;0.120mg/m^3$ after the intervention. Pb-A of part III and W was tested only after intervention and the Pb-A of part III were $0.124mg/m^3$ in Jannuary 1988 and $0.081mg/m^3$ in August 1988. The Pb-A of part IV not stationed at one place but moving around, was $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-B and Pb-A. Pb-B of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. Pb-B of the workers in the part of the lowest Pb-A incerased more rapidly. Pb-B of group C workers was the highest in part I and the lowest in part IV. These findings suggest that Pb-B is more valid method than Pb-A for monitoring the health of lead workers and intervention in personal hygiene is more effective than environmental intervention.

  • PDF

Coated Wire Lead(Ⅱ) Ion-Selective Electrodes based on Crown Ethers (Crown Ether를 이용한 탐침형 납 이온선택성 전극)

  • Jang, Mi Kyeong;Ha, Kwang Soo;Seo, Moo Lyong
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.7
    • /
    • pp.337-342
    • /
    • 1997
  • Acryloylmethylbenzo-15-crown-5 was prepared from the reaction of 4'-hydroxymethylbenzo-15-crown-5 with acryloyl chloride. And, poly(acryloylmethylbenzo-15-crown-5) [poly(AMB15C5)] was synthesized by radical polymerization using AIBN as initiator in benzene. Coated wire lead(II) ion-selective electrodes ($Pb^{2+}$-CWISEs) using either poly(AMB15C5) or B15C5 as neutral carrier were prepared, respectively. $Pb^{2+}$-CWISEs gave linear responses with slopes of 28$\pm$ 1mV per decade within the concentration range of $10^{-5} M{\sim}10^{-1}$ M, respectively. Also, the detection limits were $10^{-6}$ M and response times were either 3 or 5 min. for B15C5 and poly(AMB15C5), respectively. $Pb^{2+}$-CWISE base on B15C5 was rather unstable than poly(AMB15C5)'s due to solubility of the B15C5 in water. The selectivity coefficients of a variety of interfering ions such as $Mg^{2+},\; Ca^{2+},\; Co^{2+},\; Ni^{2+},\; Cu^{2+},\; Zn^{2+}$ and $Cd^{2+}$ were small ($10^{-4}{\sim}10^{-5}$), while those of $Na^+$ and $K^+$ were large (0.1∼0.01). In addition, the electrode responses depended upon the pH of test solution and the composition of the membrane. In the range pH 3∼6 of test solution, potentials of Pb2+-CWISEs were hardly changed. The optimal contents of B15C5 and poly(AMB15C5) were 7.7 wt% and 13.1 wt%, respectively.

  • PDF

Effect of Acutely Increased Glucose Uptake on Insulin Sensitivity in Rats (단기간의 당섭취 증가가 인슐린 감수성에 미치는 영향)

  • Kim, Yong-Woon;Ma, In-Youl;Lee, Suck-Kang
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.53-66
    • /
    • 1997
  • Insulin resistance is a prominent feature of diabetic state and has heterogeneous nature. However, the pathogenetic sequence of events leading to the emergence of the defect in insulin action remains controversial. It is well-known that prolonged hyperglycemia and hyperinsulinemia are one of the causes of development of insulin resistance, but both hyperglycemia and hyperinsulinemia stimulate glucose uptake in peripheral tissue. Therefore, it is hypothesized that insulin resistance may be generated by a kind of protective mechanism preventing cellular hypertrophy. In this study, to evaluate whether the acutely increased glucose uptake inhibits further glucose transport stimulated by insulin, insulin sensitivity was measured after preloaded glucose infusion for 2 hours at various conditions in rats. And also, to evaluate the mechanism of decreased insulin sensitivity, insulin receptor binding affinity and glucose transporter 4 (GLUT4) protein of plasma membrane of gastrocnemius muscle were assayed after hyperinsulinemic euglycemic clamp studies. Experimental animals were divided into five groups according to conditions of preloaded glucose infusion: group I, basal insulin ($14{\pm}1.9{\mu}U/ml$) and basal glucose ($75{\pm}0.7mg/dl$), by normal saline infusion; group II, normal insulin ($33{\pm}3.8{\mu}U/ml$) and hyperglycemia ($207{\pm}6.3mg/dl$), by somatostatin and glucose infusion; group III, hyperinsulinemia ($134{\pm}34.8{\mu}U/ml$) and hyperglycemia ($204{\pm}4.6mg/dl$), by glucose infusion; group IV, supramaximal insulin ($5006{\pm}396.1{\mu}U/ml$) and euglycemia ($l00{\pm}2.2mg/dl$), by insulin and glucose infusion; group V, supramaximal insulin ($4813{\pm}687.9{\mu}U/ml$) and hyperglycemia ($233{\pm}3.1mg/dl$), by insulin and glucose infusion. Insulin sensitivity was assessed with hyperinsulinemic euglycemic clamp technique. The amounts of preloaded glucose infusion(gm/kg) were $1.88{\pm}0.151$ in group II, $2.69{\pm}0.239$ in group III, $3.54{\pm}0.198$ in group IV, and $4.32{\pm}0.621$ in group V. Disappearance rates of glucose (Rd, mg/kg/min) at steady state of hyperinsulinemic euglycemic clamp studies were $16.9{\pm}3.88$ in group I, $13.5{\pm}1.05$ in group II, $11.2{\pm}1.17$ in group III, $13.2{\pm}2.05$ in group IV, and $10.4{\pm}1.01$ in group V. A negative correlation was observed between amount of preloaded glucose and Rd (r=-0.701, p<0.001) when all studies were combined. Insulin receptor binding affinity and content of GLUT4 were not significantly different in all experimental groups. These results suggest that increased glucose uptake may inhibit further glucose transport and lead to decreased insulin sensitivity.

  • PDF

The Study on the Current Status and Condition of Internet Addiction related to Disabled Person Information Technology Education (장애인 정보화교육에 따른 인터넷 중독 현황 및 실태에 관한 연구)

  • Lee, S.D.;Hong, J.A.;Yeum, D.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.63-69
    • /
    • 2012
  • The analysis was conducted for studying the degree of internet addiction and the difference between addicted group and non-addicted group based on usage time. The target group is consisted of 30 people who receive the training at home. The purpose of this training is to reduce digital divide for the disabled with reduced mobility. As a result, the typical user group, less than the 31-point appeared as 4 cases, the potentially dangerous user I group, from 31 to 54 points appeared as 25 cases, the potentially dangerous user II group, from the 54-67 points appeared as only one person. However, there was no game addiction case, more than 67 points. In addition, there was no significant difference in impulsivity and aggression between the high-risk group of 9 persons using internet more than 2.7 hours and the typical user group of 21 persons with less risk. From the result, there are two possibilities. On the one hand, an increase of the usage time for the disabled might not lead to addiction. Or, on the other hand, a measure of addiction for non-disabled might not suitable for the disabled addiction examination.

  • PDF

Identification of the Nonrecurrent Laryngeal Nerve during Thyroid Surgery: Variations, Associated Vascular Malformation, Adequate Surgical Technique (갑상선 수술시 발견된 비회귀성 후두신경; 유형, 동반 혈관 이상, 신경 손상 예방에 대한 고찰)

  • Lee Jan-Dee;Yun Ji-Sup;Lim Chi-Young;Nam Kee-Hyun;Chang Hang-Seok;Chung Woong-Youn;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.22 no.1
    • /
    • pp.3-7
    • /
    • 2006
  • Purpose: The nonrecurrent laryngeal nerve(NRLN) is a rare anomaly that is associated with the developmentally aberrant subclavian artery. Although rare on the right side and exceptional on the left, an aberrant nonrecurrent pathway for RLN represents a major surgical risk. Three course variations of right NRLN can be distinguished: descending(type I) , horizontal(type II), ascending(type III). This study is performed to characterize the variations of NRLN, associated vascular anomaly, and proper surgical methods for preventing nerve damage. Materials and Methods: Between January 1998 and March 2006 3,381 thyroidectomy were performed at our institution, and during these operations a nonrecurrent laryngeal nerve was observed in 13 cases (0.38%). There were 1 men and 12 women with a median age of 48 years(range 28-57). All of them are identified on the right side. Results: In all cases, there were no clinical symptoms observed preoperatively. The nerve anomaly was diagnosed preoperatively in only one case. There were type I variations of right RLN in 2 cases and type II variations in 11 cases. The retroesophageal aberrant right subcalvian artery; no innominate(brachiocephalic) artery was found and the right common carotic artery was arising directly from the aortic arch, was seen in 12 cases. A vocal cord palaysis caused by NRLN damage during operation was observed in one patient(7.6%) , where the nerve was close to the superior thyroid artery. No other complications were noted. Conclusion: It can be possible to predict NRLN from signs associated with the vascular anomaly; clinical symptoms or imaging studies. When an vascular anomaly is not detected preoperatively, overlooking possibility of NRLN may lead to severe operative morbidity. Hence, It is most important to identify all the thyroid structures carefully during thyroid surgery and to be aware of the possibility of anatomic variations of RLN.

The 2nd Stability Appraisement on Cultural Property Material with the Replacing Fumigation Gas of Methyl Bromide II (Methyl Bromide를 대체하는 훈증 가스의 문화재 재질 안정성 평가 II)

  • Kang, Dai-Ill
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.465-471
    • /
    • 2009
  • In this study, the substitution fumigation gases (15% Ethylene Oxide + 85% HFC 134a, 20% Ethylene Oxide + 80% $CO_2$, 99% Sulfuryl Fluoride + 1% Inert Gas) were applied on the metal, pigment, fabric and paper specimen. The result of the fumigation treatment with 15% Ethylene Oxide + 85% HFC 134a (200g/$m^3$, 48hours) is the color changes (${\Delta}E$) of 1st and 2nd Cu specimens showed significant difference as 3.40, 4.17. On the other hand, other specimens except for Cu showed less than 3.0 in chrominance values. The result with 20% Ethylene Oxide + 80% $CO_2$ (150g/$m^3$, 48hours) is that the color changes (${\Delta}E$) of 1st and 2nd specimens were overall less than 3.0 so that color differences were subtle and hardly recognized with naked eyes. So it is proved that the fumigation treatment with Ethylene Oxide 20% + $CO_2$ 80% is relatively stable on materials in this study. In the case of 99% Sulfuryl Fluoride + 1% Inert Gas (50g/$m^3$, 48hours), the color difference of Lead red ($PbO_4$) of pigment was more than 3.0 that was compared with contrast specimens. But chrominance values in the other specimens were less than 3.0 on average.

  • PDF

Genetic Relationship Between Weaning Weight and Carcass Traits in Hanwoo (한우의 이유시 체중과 도체형질과의 유전적 관계)

  • Hwang, J.M.;Choi, J.G.;Kim, H.C.;Choy, Y.H.;Lee, C.;Yang, B.K.;Shin, J.S.;Kim, Jong-Bok
    • Journal of Animal Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.177-182
    • /
    • 2007
  • The objective of this study was to evaluate the genetic relationship between weaning weight (WW) and carcass traits. Carcass traits were eye muscle area(EMA), back fat thickness(BFT), marbling score 1(MS1) in 21 grade scales, marbling score 2(MS2) in 7 grade scales and meat color scores(Mcolor). Parameters were estimated by REML procedure with MTDFREML package. Models included contemporary group as defined by the same year-season-sex at birth, linear covariates of age(days) at weaning, age of dam(days) and age at slaughter(days) as fixed effects and animal random effects for all the traits. Heritability estimates of WW, EMA, BFT, MS1, MS2 and Mcolor were 0.25, 0.20, 0.20, 0.32, 0.32 and 0.22, respectively. Genetic(phenotypic) correlation coefficients of WW with EMA, BFT, MS1, MS2 and Mcolor were 0.75(0.16), 0.18(0.05), -0.41(-0.09), -0.40(0.11) and -0.07(0.05), respectively. Results from this study suggest that single trait selection for weaning weight would lead to progeny population having carcass with large EMA, thick BFT and decreased MS.

A Basic Study on the Effective Management for MSWI Fly Ash (II) - Effect of Leaching Parameter - (소각 비산재의 적정처리를 위한 기초연구(II) - 용출인자의 영향 -)

  • Kim, Jin-Beom;Lee, Woo-Keun;Shim, Yeong-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1357-1364
    • /
    • 2000
  • Our study was performed to evaluate the effect of leaching parameters including the physicochemical characteristics and the fractionated composition of heavy metals on the release of heavy metals in fly ash discharged from MSWI. Leaching parameters such as pH, CEC, particle size, and exchangeable fraction among the fractional composition classified by sequential extraction procedure are considered. The leaching rate of heavy metal released by KSLT method is largely dependent on the pH of fly ash. The effect of pH on the release of heavy metals is different from elements. It appears that the leaching rate of cadmium and copper decreases with increasing pH, while lead and zinc increases at the condition of neutral or strong alkali condition, which suggests that the leaching of heavy metals are limited by the solubility. It is found that the effect of CEC is similarly to that of pH, $D_{10}$ among the particle size of fly ash is negative correlated with the concentration of heavy metals leached by KSLT method. In the case of exchangeable fraction, the leaching rate of heavy metals is linearly correlated with the exchangeable fraction for the fly ash below 40 meq/l00g of CEC, but not related out of the range.

  • PDF