• Title/Summary/Keyword: lateral view of body

Search Result 53, Processing Time 0.027 seconds

Wearing Test for New-Bunka Pattern Making of Men's Body Type through Virtual Garment

  • Jeong, Mi-E.;Choi, Mee-Sung
    • Journal of Fashion Business
    • /
    • v.9 no.3
    • /
    • pp.88-98
    • /
    • 2005
  • This study focuses on the needs at both consumers and manufacturers. It aims to find ways for consumers to purchase outfits that would fit their particular body type and preferences at reasonable prices, choose raw materials and style at garments, and virtually try them on. In addition, the study is designed to help apparel manufacturers identity customers' changing needs, reduce inventories, manage information on customers' body type in a digitalized form, and eventually contribute to promoting electronic commerce. Based on nine basic patterns that tit each subject, 108 virtual garments are created by adjusting the size of the patterns (9 subjects $\times$ 4 body parts $\times$ 3 patterns = 108 outfits). In order to determine fitting preferences for each body part and find optimized conditions, cross-tabulation analysis including $X^2$ and frequency analysis were performed to measure the appearance rate. A style of virtual garment, which is minus 2cm from chest size was chosen as the most appropriate pattern to the baseline location of front the chest. For the waist parts, the C style as an appropriate virtual garment to front and back view. In the front, lateral and back view, a style was chosen in the response to the sleeve-bodice combinations, the ease amount of armhole area, the armhole depth and the loosening of tightening or armhole line.

The Study on Standard Bodytype for Korean Women between the ages of 18 and 24 years old(Part I) -focusing on the analysis of the High-frequency type and the High-frequency range- (18~24세 한국인 여성의 표준체형에 관한 연구(제1보) -다빈도유형 및 다빈도구간에 대한 분석을 중심으로-)

  • 이정임;남윤자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.5
    • /
    • pp.630-641
    • /
    • 2002
  • The purpose of this study is to suggest the standard of bodytype which offers various data with regard to three-dimensional characteristics of body, and which offers the criterion for the sizes and shapes to interpret various bodytypes, to estimate filling, and to construct ready-made clothing. In this study, standard bodytype was defined as a typical type with beautiful proportion and shape which a large number of people have, too. In order to continue this study, there were two ways of analyzing bodytypes of subjects in the view of statistics and beauty. We primarily carried on statistical analysis in this report. Taken as a sample, the subjects were ninety-seven females who were between the ages of 18 and 24 years o1d. They were measured on November 1999. The data of seven hundred and few females, 18∼24 year-old, from the National Somatometry Survey of 1997 were used for analysis, too. Three kinds of classification methods were used for statistical analysis. The first method was based on the lateral view of the body, the second was based on the Factor and Cluster analysis of the photographic measurements of each of the anterior and lateral body, and the third was based on the Factor and Cluster analysis of the anthropometric measurements of the whole body. From the analysis on the distribution of R hrer Index the difference of width, the difference of depth, the proportion of height and head height, the High-frequency Proportion(H.P.)range were selected. The straight type from the lateral view, High-frequency type from each method, and subjects in H.P. range were compared with each other. As the result, it was confirmed that it is proper to base on the size and shape of subjects in H.P. range to analyze the standard bodytype.

Control of Vehicle Lateral Dynamics using Sliding Mode with Time-Varying Switching Surface (시변 절환면을 갖는 슬라이딩 모드에 의한 차량의 횡방향 운동제어)

  • Lee, Chang-Ro;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.458-463
    • /
    • 2000
  • This paper presents a design of the controller for vehicle lateral dynamics using active yaw moment. Vehicle lateral motion is incorporated with directional controllability and stability. These are conflicting each other from the view of vehicle handling performance. To compromise the trade-off between these two aspects, we suggest a new control algorithm based on the sliding mode with time-varying switching surface according to the body side slip angle. The controller can deal with the nonlinear region in vehicle driving and be robust to the parameter uncertainties in the plant model. Control performance was evaluated from the simulation.

  • PDF

The Adequacy of a Cross Table Lateral Cervical X-ray in Severely Traumatized Korean Patients (한국인 중증 외상 환자에서 촬영한 경추 외측면 단순 방사선 영상의 적절성)

  • Lee, Kyung-Hag;Kim, Yeong Cheol;Choi, Seok Ho;Han, Gook Nam;Lee, Soo Un;Lee, Jung Eun;Suh, Gil Joon;Yoon, Yeo-Kyu
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.241-246
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the appropriateness of the cross table lateral cervical X-ray used in the emergency department for severely traumatized Korean patients. Methods: Patients visiting our institution from May 2011 to May 2012, who had injury severity score (ISS) > 15 and who received a cervical X-ray in the emergency department, were included in this study. Data including demographics, ISS score, GCS score, and place where the x-ray was taken were collected to evaluate their relationship with appropriate coverage of the cervical X-ray. The appropriateness of a cervical cross lateral view X-ray was evaluated using exposure of the basion, and the opisthion, as well as the distal level of exposure. Results: Fifty-two patients were included in this study. The identification rate of the basion was 79.2%, and the identification rate of the opisthion was 88.7%. Complete exposure of C7/T1 was accomplished in 3.8% of the patients. The ISS was higher for X-ray taken in the trauma bay, but the range of exposure showed no difference between the places where the X-rays taken. Patients who had exposure of C 5/6 or more had lower body weight and body mass index (BMI) compared with unexposed patients. Conclusion: In severely traumatized Korean patients, the adequacy of the cross table lateral cervical X-ray was inappropriate in most cases. No difference was observed in the exposure range between the places where the X-rays were taken, and patients with less exposure showed higher body weight and higher BMI.

Control of Vehicle Yaw Moment using Sliding Mode with Time-Varying Switching Surface (시변절환면을 갖는 슬라이딩 모드에 의한 차량의 요-모멘트 제어)

  • Lee, Chang-Ro;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.5
    • /
    • pp.666-672
    • /
    • 2003
  • This paper presents a design of the controller for vehicle lateral dynamics using active yaw moment. Vehicle lateral motion is incorporated with directional controllability and stability. These are conflicting each other from the view of vehicle handling performance. To compromise the trade-off between these two aspects, we suggest a new control algorithm based on the sliding mode with time-varying switching surface according to the body side slip angle. The controller can deal with the nonlinear region in vehicle driving condition and be robust to the parameter uncertainties in the plant model. Control performance is evaluated from the simulation for the vehicle of real parameters on the road with various tire-road frictions.

Analysis of the Acceleration Characteristics on the Conventional line for Korean High Speed Train- in il point of passing speed on the curve (한국형 고속전철의 기존선 주행 진동가속도 특성 분석 - 곡선 통과속도 중심으로)

  • 김영국;김석원;목진용;박찬경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.222-227
    • /
    • 2004
  • Korean High Speed Train(KHST) has been tested on the high speed test line in Osung site, since it was developed through the G7 Project Plan in 2002. It was also tested on the conventional line such as KyongBu and Honan Line to know the possibility of increasing the limited speed for the high speed trains. This paper introduces the method to improve the speed on the conventional line with body lateral acceleration among the several considered issues and explains the parameters related to those analysis, such as the cant deficiency, the radius of curve, speed and etc. When a train pass on the curved track, the lateral accelerations of body are divided into the quasi-static and the maximum accelerations according to the UIC 518 which is the international specification for testing and approval of railway vehicles from the point of view of their dynamic behaviour, especially for safety and ride comfort. This paper shows that it is safe and comfort from the results of test when KHST runs on the conventional line with the curves and proposes that the limited speed of conventional curved line could be changed to a little higher speed if the analysises of other fields are completed.

  • PDF

Usefulness of 3-Dimensional Body Surface Scanning in the Evaluation of Patients with Pectus Carinatum

  • Song, Seung Hwan;Kim, Chong Hoon;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.301-305
    • /
    • 2020
  • Background: Radiographic modalities have been commonly used to evaluate pectus carinatum (PC), and compressive orthotic bracing is the most widely accepted treatment method. The aim of this study was to determine the efficacy of 3-dimensional (3D) body surface scanning as an alternative modality for the evaluation of PC. Methods: The medical records of 63 patients with PC who were treated with compressive orthotic bracing therapy between July 2017 and February 2019 were retrospectively analyzed. Using both 2-view chest radiography (posteroanterior and lateral view) and 3D body scanning, the height of maximal protrusion of the chest wall was measured both before and after 2 weeks of bracing therapy. The difference between the pre- and post-treatment measurements was calculated for both modalities, and these differences were compared and analyzed. Results: Based on the comparison between the pre- and post-treatment radiographs, bracing therapy produced favorable outcomes in all patients (p<0.001). The measurements obtained via 3D scanning were strongly correlated with those obtained via chest radiography (r=0.60). Conclusion: Based on the findings of this study, 3D body surface scanning appears to be an effective, radiation-free, and simple method for the post-treatment follow-up evaluation of PC, and thus can be considered an alternative to radiography.

Utility of False Profile View for Screening of Ischiofemoral Impingement

  • Kwak, Dae-Kyung;Yang, Ick-Hwan;Kim, Sungjun;Lee, Sang-Chul;Park, Kwan-Kyu;Lee, Woo-Suk
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.219-225
    • /
    • 2018
  • Purpose: Ischiofemoral impingement (IFI)-primarily diagnosed by magnetic resonance imaging (MRI)-is an easily overlooked disease due to its low incidence. The purpose of this study was to evaluate the usefulness of false profile view as a screening test for IFI. Materials and Methods: Fifty-eight patients diagnosed with IFI between June 2013 and July 2017 were enrolled in this retrospective study. A control group (n=58) with matching propensity scores (age, gender, and body mass index) were also included. Ischiofemoral space (IFS) was measured as the shortest distance between the lateral cortex of the ischium and the medial cortex of lesser trochanter in weight bearing hip anteroposterior (AP) view and false profile view. MRI was used to measure IFS and quadratus femoris space (QFS). The receiver operating characteristics (ROC), area under the ROC curve (AUC) and cutoff point of the IFS were measured by false profile images, and the correlation between the IFS and QFS was analyzed using the MRI scans. Results: In the false profile view and hip AP view, patients with IFI had significantly decreased IFS (P<0.01). In the false profile view, ROC AUC (0.967) was higher than in the hip AP view (0.841). Cutoff value for differential diagnosis of IFI in the false profile view was 10.3 mm (sensitivity, 88.2%; specificity, 88.4%). IFS correlated with IFS (r=0.744) QFS (0.740) in MRI and IFS (0.621) in hip AP view (P<0.01). Conclusion: IFS on false profile view can be used as a screening tool for potential IFI.

A Double-coin in esophagus (흥미있는 식도이물 1례)

  • 강주원;장혁순;박성남
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.13.2-13
    • /
    • 1983
  • Foreign bodies in air and food passages are not uncommon conditions in otolaryngological field and we can find out numerous causes of esophageal foreign bodies in literatures. Radiological exammination is essential and important method in diagnosis of foreign bodies in esophagus. The authors experienced a case of foreign body double coins, in esophagus in a 4-year - old girl and the authors emphasizing that in cases of esophageal foreign bodies radiological examination should always be included lateral view as well as anteroposterior view of neck especially when coins in the esophagus is suspected.

  • PDF

A Study on the Basic Slacks Pattern for Middle Aged Women Based on Their Lower Body Shape Analysis (중년여성의 하반신 체형분류에 따른 슬랙스 원형 제작)

  • 성옥상;정인향
    • The Research Journal of the Costume Culture
    • /
    • v.7 no.6
    • /
    • pp.140-158
    • /
    • 1999
  • The purposes of this study are to examine the characters of the lower body shape in the middle aged women and to make slacks pattern on the base of four difference body shapes. The lower body shapes were classified into 4 types on the basis of their lateral view silhouettes. The slacks patterns were based on the lower body shape characters and resulted in followings. In “Type 1” of the right body shape with the standard protrusion of abdomen and hips, little difference from conventional patterns was seen in experiment pattern, in which the front waist girth was W/4+0.5㎝+0.5㎝+fold(2.5㎝) and the back waist girth W/4+0.5㎝-0.5㎝+dart(3.5㎝). The front hip girth was defined as H/4+2.0㎝+0.5㎝ and the back hip girth as H/4+2.0㎝-0.5㎝ due to its increased ease amount produced by abdominal fat deposition. In the experimental pattern of “Type 2” with prominent hips, the front and back differences of the waist girth and the hip girth and the hip girth were defined as 1.0㎝ and 2.0㎝ separately. Accordingly, the front waist girth was W/4+0.5㎝+1.0㎝+fold(2.0㎝), the back waist girth W/4+0.5㎝-0.1㎝+dart(6.5㎝), the front hip girth H/4+2.0㎝+1.0㎝ and the back hip girth H/4+2.0㎝-1.0㎝. In “Type 3” with the prominent abdomen and the flat hips, the front waist girth was set up as W/4+0.5㎝+0.5㎝+fold(4.5㎝) for the increased front fold amount and the back waist girth was W/4+0.5㎝+0.5㎝+dart(3.0㎝). The front hip girth was made as H/4+2.5㎝+0.5㎝ and the back hip girth H/4+2.5㎝-0.5㎝. In “Type 4” with prominent abdomen and hips, considered were ① the increased front fold amount due to the abdominal protrusion, ② the increased back dart amount and the decreased back dart length owing to the hips prominent and ③ the front and back differences of waist and hip girth for the lateral view silhouette. Therefore the front waist girth was defined as W/4+0.5㎝+2.0㎝+fold(5.0㎝), the back waist girth as W/4+0.5㎝-2.0㎝+dart(4.0㎝), the front hip girth as H/4+2.0㎝+1.0㎝ and the back hip girth as H/4+2.0㎝-1.0㎝. The sensory evaluation of appearance and comfort was appeared more suitable on the experiment pattern than on the conventional pattern.

  • PDF