• Title/Summary/Keyword: lateral process

Search Result 771, Processing Time 0.027 seconds

3-DOF automatic printed board positioning system using impact drive mechanism

  • Mendes, J.;Nishimura, M.;Yamagata, Y.;Higuchi, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.129-132
    • /
    • 1996
  • There is a tendency nowadays to produce increasingly miniaturized electronic equipment which incorporate parts that have to be precisely positioned, like lenses, heads and CCD's in scanners, printers, copiers, VCR's, optical fiber modules, etc. In contrast to the production process of precision parts, which is currently being carried out automatically, the assemblage process is still being performed by specially skilled technicians. The assemblage process comprises normally the following steps: firstly, the parts are roughly positioned and partially fixed, secondly, the parts are manually nudged towards the target position and finally glued, screwed or welded. This paper presents a system that uses six piezo Impact Drive Mechanisms for accurate micro positioning within three degrees of freedom (lateral and longitudinal translation and rotation). The system is designed to positioning a printed circuit board with an accuracy better than 3 .mu.m (for translations), 5 mrad (for rotation).

  • PDF

New Fabrication Process of Vertical-Type Organic TFTs for High-Current Drivers

  • Kudo, Kazuhiro;Nakamura, Masakazu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.307-309
    • /
    • 2009
  • We have fabricated vertical-type organic transistors (static induction transistors; SITs) with built-in nano-triode arrays formed in parallel by a colloidal-lithography technique. Using this technique, we could fabricate a microstructure in a lateral direction within a large-scale organic device without relying on photolithography. The organic transistor showed low operating voltages, high current output, and large transconductance.

  • PDF

Giant Leiomyoma of the Esophagus - A Case Report - (거대 식도평활근종 수술치험 1예)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.22 no.3
    • /
    • pp.518-523
    • /
    • 1989
  • A 42-year old male was seen with symptoms of dysphagia, chest pain and dyspnea of 9 months duration. A benign tumor of the posterior mediastinum was diagnosed from x-ray studies and a transthoracic needle aspiration biopsy which was inconclusive. A left thoracotomy revealed a huge mass occupying the retrocardiac space and the contra-lateral mediastinum. It was resected by blunt dissection and, during this process, a 3.0 cm laceration was created in the esophageal wall. This was repaired with Tevdec sutures and staplers and was reinforced with an intercostal muscle flap to prevent leakage. The postoperative course was entirely uneventful.

  • PDF

A Comparative study of Simple Tracing with Gothic Arch Tracing (Gothic arch tracing technique에 비교된 Simple tracing에 관한 연구)

  • Bae, Bong-Jin
    • Journal of Technologic Dentistry
    • /
    • v.2 no.1
    • /
    • pp.25-27
    • /
    • 1980
  • In the process of arranging artificial teeth the simple atracing technique was shown to be more precise and convenient for general use in dental clinic than gothic arch tracing. The simple tracing technique had some advantages over other ones in that they were very useful to check protrusive, lateral and central occlusion of mandible movement, and it was very easy to transfer the oral condition and mandible movements precisely onto the articulator. Also the technique was more effective than when using wax bite in that the functional movement range has shifted to 0.2 - 0.4mm form central occlusion.

  • PDF

A Study on the Characteristics of Color for Peter Eisenman Architecture (피터 아이젠만 건축의 색채사용특성에 관한 연구)

  • Lee, Seon-Min;You, Yeon-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.2
    • /
    • pp.61-70
    • /
    • 2009
  • Architectural color would be understood as a essential tool to be reflected the architect's value criteria, thinking process and the specific methodology. This study was established the characteristics of color use correlated with Eisenman's architectural features based on his point of view. At first, it could be organized with data and use the color in view points with the becomming process. Especially it would be expressed the color as a trace of unsynchronized formation. Second, it was introduced the color by graphics engaged with form, to be expressed the dividing, folding, reiteration for deliver of escape from graphic thinking process. Third, it was analyzed to be imported the color to have a multi-lateral space experience in center of user's space recognition and behavior by introduction of color. Finally, it could be inducted the consistent color by viewpoint of interfacial between interior and exterior environment, communicated with strong meaning by conversion from interior elements to color from these processes. A characteristics of Eisenman's architecture color is reflected his thinking process in architecture color as it is and can be understand of 'becomming process use of color' as a tool that is corresponded in form creation. Specially, it would be kept continuous viewpoint of interior and exterior space, giving user color as a viewpoint of linking space, enable many-sidedness experiences through space.

Fabrication of Superjunction Trench Gate Power MOSFETs Using BSG-Doped Deep Trench of p-Pillar

  • Kim, Sang Gi;Park, Hoon Soo;Na, Kyoung Il;Yoo, Seong Wook;Won, Jongil;Koo, Jin Gun;Chai, Sang Hoon;Park, Hyung-Moo;Yang, Yil Suk;Lee, Jin Ho
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.632-637
    • /
    • 2013
  • In this paper, we propose a superjunction trench gate MOSFET (SJ TGMOSFET) fabricated through a simple p-pillar forming process using deep trench and boron silicate glass doping process technology to reduce the process complexity. Throughout the various boron doping experiments, as well as the process simulations, we optimize the process conditions related with the p-pillar depth, lateral boron doping concentration, and diffusion temperature. Compared with a conventional TGMOSFET, the potential of the SJ TGMOSFET is more uniformly distributed and widely spread in the bulk region of the n-drift layer due to the trenched p-pillar. The measured breakdown voltage of the SJ TGMOSFET is at least 28% more than that of a conventional device.

Ununited Anconeal Process in a Labrador Retriever Dog

  • Lee, Jae-Hoon;Yang, Wo-Jong;Kang, Eun-Hee;Chang, Hwa-Seok;Chung, Dai-Jung;Choi, Chi-Bong;Lee, Jeong-Ik;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.537-539
    • /
    • 2008
  • A 6 month-old male Labrador retriever was presented for intermittent lameness on the left forelimb after exercise. The dog was suffering progressive lameness that had started two months before. On mediolateral radiographic view of the left elbow, proximal margin of the anconeal process was irregular. A lucent, indistinct line separating the anconeal process from the ulna was observed, when the elbow joint was flexed. The lateral approach to the elbow joint was used and the ununited anconeal process was removed. The limb was bandaged after surgery for 7 days to support soft tissue and exercises were restricted. The dog showed normal limb function 3 weeks after surgery. On a telephone conversation with the owner 18 months after surgery, the dog was reported to maintain normal function of the limb.

Optimal parameter derivation for Muskingum method in consideration of lateral inflow and travel time (측방유입유량 및 유하시간을 고려한 Muskingum 최적 매개변수 도출)

  • Kim, Sang Ho;Kim, Ji-sung;Lee, Chang Hee
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.827-836
    • /
    • 2017
  • The most important parameters of the Muskingum method, widely used in hydrologic river routing, are the storage coefficient and the weighting factor. The Muskingum method does not consider the lateral inflow from the upstream to the downstream, but the lateral inflow actually occurs due to the rainfall on the watershed. As a result, it is very difficult to estimate the storage coefficient and the weighting factor by using the actual data of upstream and downstream. In this study, the flow without the lateral inflow was calculated from the river flow through the hydraulic flood routing by using the HEC-RAS one-dimensional unsteady flow model, and the method of the storage coefficient and the weighting factor calculation is presented. Considering that the storage coefficient relates to the travel time, the empirical travel time formulas used in the establishment of the domestic river basin plan were applied as the storage coefficient, and the simulation results were compared and analyzed. Finally, we have developed a formula for calculating the travel time considering the flow rate, and proposed a method to perform flood routing by updating the travel time according to the inflow change. The rise and fall process of the flow rate, the peak flow rate, and the peak time are well simulated when the travel time in consideration of the flow rate is applied as the storage coefficient.

Anatomical Morphometric Study of the Cervical Uncinate Process and Surrounding Structures

  • Kim, Sung-Ho;Lee, Jae Hack;Kim, Ji Hoon;Chun, Kwon Soo;Doh, Jae Won;Chang, Jae Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.300-305
    • /
    • 2012
  • Objective : The purpose of this study is to elucidate the anatomic relationships between the uncinate process and surrounding neurovascular structures to prevent possible complications in anterior cervical surgery. Methods : Twenty-eight formalin-fixed cervical spines were removed from adult cadavers and were studied. The authors investigated the morphometric relationships between the uncinate process, vertebral artery and adjacent nerve roots. Results : The height of the uncinate process was 5.6-7.5 mm and the width was 5.8-8.0 mm. The angle between the posterior tip of the uncinate process and vertebral artery was $32.2-42.4^{\circ}$. The distance from the upper tip of the uncinate process to the vertebral body immediately above was 2.1-3.3 mm, and this distance was narrowest at the fifth cervical vertebrae. The distance from the posterior tip of the uncinate process to the nerve root was 1.3-2.0 mm. The distance from the uncinate process to the vertebral artery was measured at three different points of the uncinate process : upper-posterior tip, lateral wall and the most antero-medial point of the uncinate process, and the distances were 3.6-6.1 mm, 1.7-2.8 mm, and 4.2-5.7 mm, respectively. The distance from the uncinate process tip to the vertebral artery and the angle between the uncinate process tip and vertebral artery were significantly different between the right and left side. Conclusion : These data provide guidelines for anterior cervical surgery, and will aid in reducing neurovascular injury during anterior cervical surgery, especially in anterior microforaminotomy.