• 제목/요약/키워드: lateral load-resisting systems

검색결과 54건 처리시간 0.023초

내부 포스트 텐션 플랫 플레이트 슬래브 기둥 접합부의 이력거동 (Cyclic Behavior of Interior Joints in Post Tensioned Flat Plate Slab Systems)

  • 기성훈;한상환;하상수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.107-110
    • /
    • 2005
  • In general, post tensioned (PT) flat plate slab systems have been used as a Gravity Load Resisting System (GLRS) in buildings. Thus, these systems should be constructed with Lateral Force Resisting Systems (LFRS) such as shear walls and moment resisting frames. When lateral loads such as winds or earthquakes occur, lateral load resisting systems undergo displacement by which connected gravity systems experience lateral displacement. Therefore, GLRS should have some lateral displacement capacity in order to hold gravity loads under severe earthquakes and winds. Since there are the limited number of researches on PT flat plate slab systems, the behavior of the systems have not been well defined. This study investigated the cyclic behavior of post tensioned flat plate slab systems. For this purpose, an experimental test was carried out using 4 interior PT flat plate slab-column specimens. All specimens have bottom reinforcement in the slab around the slab-column connection. Test variables of this experimental study are vertical load level and tendon distribution patterns.

  • PDF

Seismic performance of lateral load resisting systems

  • Subramanian, K.;Velayutham, M.
    • Structural Engineering and Mechanics
    • /
    • 제51권3호
    • /
    • pp.487-502
    • /
    • 2014
  • In buildings structures, the flexural stiffness reduction of beams and columns due to concrete cracking plays an important role in the nonlinear load-deformation response of reinforced concrete structures under service loads. Most Seismic Design Codes do not precise effective stiffness to be used in seismic analysis for structures of reinforced concrete elements, therefore uncracked section properties are usually considered in computing structural stiffness. But, uncracked stiffness will never be fully recovered during or after seismic response. In the present study, the effect of concrete cracking on the lateral response of structure has been taken into account. Totally 120 cases of 3 Dimensional Dynamic Analysis which considers the real and accidental torsional effects are performed using ETABS to determine the effective structural system across the height, which ensures the performance and the economic dimensions that achieve the saving in concrete and steel amounts thus achieve lower cost. The result findings exhibits that the dual system was the most efficient lateral load resisting system based on deflection criterion, as they yielded the least values of lateral displacements and inter-storey drifts. The shear wall system was the most economical lateral load resisting compared to moment resisting frame and dual system but they yielded the large values of lateral displacements in top storeys. Wall systems executes tremendous stiffness at the lower levels of the building, while moment frames typically restrain considerable deformations and provide significant energy dissipation under inelastic deformations at the upper levels. Cracking found to be more impact over moment resisting frames compared to the Shear wall systems. The behavior of various lateral load resisting systems with respect to time period, mode shapes, storey drift etc. are discussed in detail.

Evaluation of lateral stiffness of steel structures having different types of lateral load-resisting systems

  • Kabir Sadeghi;Krekar Kadir Nabi;Fatemeh Nouban
    • Advances in Computational Design
    • /
    • 제9권3호
    • /
    • pp.151-165
    • /
    • 2024
  • In this paper, the evaluation of the elastic lateral stiffness factor (ELSF) of steel frames for different lateral load-resisting systems (LLRSs) is presented. First, 720 steel structural frame models have been analyzed and designed using the equivalent lateral force method. Then by using pushover analysis method, all models have been analyzed, compared and evaluated. Finally, the effects of a number of influenced parameters such as different types of LLRSs, span length, number of stories, number of spans as well as story height of the buildings on the lateral stiffness are assessed and by applying regression analysis some useful equations were submitted. Based on the results obtained for steel frames having different LLRSs, compared to ordinary moment-resisting frames (OMRFs) as a base (having ELSF of 1), the normalized average ELSFs of K-eccentrically braced-frames (K-EBFs), V-, Z-, inverted V-, X-braced-frames, shear walls with thickness of 25 cm (SW25) and shear walls with thickness of 30 cm (SW30) are about 2.2, 6, 7, 9, 11, 95, 155, respectively. Among the braced-frames, X-braced-frames have the maximum ELSF, about 10 times more than OMRF, while OMRFs provide the minimum ELSFs among all LLRSs, and the frames supported by shear walls have ELSFs about 100 to 150 times more than OMRFs.

포스트 텐션 플랫 플레이트 슬래브 접합부의 거동 (Structural Behavior of Post-Tensioned Flat Plate Slab-Column Connections)

  • 조경현;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.53-56
    • /
    • 2004
  • Recently, post tension flat plate slab system is widely used for a new slab structural system. Slab-column connections may fail in brittle manner by punching shear. Flat plate slabs have been widely used for gravity load resisting system in buildings. Lateral resistance usually provided by shear walls or moment resisting frames. Since plat plates move together with lateral loading system during earthquake or wind, it is important to evaluate the gravity resistance under a drift experienced by lateral force resisting system during either design earthquake or wind. Thus, this study investigated post tension flat plate slab systems whether they have sufficient strength and deformability to resist gravity loads during specified drift levels. Experimental research was carried out.

  • PDF

Evaluation of cyclic behavior of lateral load resisting system with eccentric brace and steel plate

  • Reza Khalili Sarbangoli;Ahmad Maleki;Ramin K. Badri
    • Structural Engineering and Mechanics
    • /
    • 제89권3호
    • /
    • pp.239-252
    • /
    • 2024
  • Steel plate shear walls (SPSWs) are classified as lateral load-resisting systems. The feasibility of openings in the steel plate is a characteristic of SPSWs. The use of openings in SPSWs can lower the load capacity, stiffness, and energy dissipation. This study proposes a novel form of SPSWs that provides convenient access through openings by combining steel plates and eccentrically braced frames (EBFs). The proposed system also avoids a substantial reduction in the strength and stiffness. Hence, various geometric forms were analyzed through two different structural approaches. Groups 1, 2, and 3 included a steel EBF with a steel plate between the column and EBF in order to improve system performance. In Group 4, the proposed system was evaluated within an SPSW with openings and an EBF on the opening edge. To evaluate the performance of the proposed systems, the nonlinear finite element method (NL-FEM) was employed under cyclic loading. The hysteresis (load-drift) curve, stress contour, stiffness, and damping were evaluated as the structural outputs. The numerical models indicated that local buckling within the middle plate-EBF connection prevented a diagonal tension field. Moreover, in group 4, the EBF and stiffeners on the opening edge enhanced the structural response by approximately 7.5% in comparison with the base SPSW system.

극취성·전단·휨파괴형 수평저항시스템으로 구성된 저층 철근콘크리트 건물의 요구 내력 스펙트럼 (Demand Strength Spectrums of Low-Rise Reinforced Concrete Buildings Consisted of Extremely Brittle, Shear and Flexural Failure Systems)

  • 이강석;김정희;오재근
    • 콘크리트학회논문집
    • /
    • 제19권5호
    • /
    • pp.529-537
    • /
    • 2007
  • 대다수의 저층 RC 건물은 다양한 수평저항시스템으로 이루어져 있으며, 이것들은 각기 다른 변위에서 파괴될 것으로 판단된다. 그 가운데에서도, 강성 및 강도는 높지만 소성영역에서 극취성적인 파괴성상을 나타내는 극단주, 전단벽 등의 전단파괴형 부재 및 비교적 강성 및 강도는 낮지만 연성 능력이 탁월한 기둥 등의 휨파괴형 부재는 전형적인 수평저항시스템으로 다수의 피해지진에 의하여 그것들의 중요성이 대두되었다. 극단주, 전단벽, 휨기둥 등과 같이 서로 다른 성질의 역학적 특성을 가지는 내진 요소로 혼합된 저층 RC 건물의 내진성능을 평가하기 위해서는, 각각 부재의 내력과 변형 능력이 건물 전체의 내진성능에 어떻게 영향을 미치는가를 우선적으로 검토하는 것이 필요하다. 본 연구는 극단주 (극취성파괴형 부재), 전단벽 (전단파괴형 부재) 및 휨기둥 (휨파괴형 부재)이 혼합된 저층 RC 건물의 내진성능 평가법 개발 및 내진설계를 위한 기본적인 자료를 제공하는 것을 주목적으로, 각각 파괴형 부재의 강도와 변형능력 사이의 상관관계를 파악하여, 이것들의 비율이 건물 전체의 내진성능에 어떻게 영향을 미치는가를 비선형 지진응답해석을 실시 검토하여 최종적으로 극취성 전단 휨파괴형 수평저항시스템으로 구성된 저층 RC 건물의 요구 내력 스펙트럼을 제안하였다. 본 연구에서 제안된 요구 내력은 특정 지역에서 요구하는 지진수준에 대하여 지진발생시 특정 연성비 이내로 머물게 하는 하한내력의 범위를 파악할 수 있으므로 요구 내력 스펙트럼은 내진성능 평가 및 내진설계의 기본적인 자료로서 활용 가능하다고 판단된다.

프리캐스트 콘크리트 벽체의 상하부에 C형강 보가 결합된 복합 패널의 개발 (Development of Hybrid Panel with C-shaped Steel Beam at Top and Bottom of Precast Concrete Wall)

  • 이상섭;박금성
    • 한국강구조학회 논문집
    • /
    • 제29권6호
    • /
    • pp.435-442
    • /
    • 2017
  • 모듈러 건축물을 중고층화하기 위해 횡력저항시스템은 반드시 필요한 구조 요소로 10~20층 규모에서 콘크리트 코어는 가장 전형적인 횡력저항시스템으로 알려져 있다. 습식 공법인 콘크리트 코어 공사는 모듈의 오염과 파손 가능성으로 모듈 적층과의 동시 작업이 곤란하다. 이에 모듈 적층과 콘크리트 코어의 동시 시공이 가능한 복합 PC 패널 공법을 개발하였다. 복합 PC 패널은 일정 간격을 두고 웨브가 마주보는 한 쌍의 C형강을 콘크리트 벽체의 상부와 하부에 결합한 구조 부재로 볼트로 접합하여 적층하는 건식 공법으로 콘크리트 코어를 구축할 수 있다. 이 연구에서는 복합 PC 패널이 콘크리트 벽체와 동등한 성능을 갖도록 해석을 통해 상세 개선 과정을 제시하였다.

Experimental study on cyclic behavior of reinforced concrete parallel redundancy walls

  • Lua, Yiqiu;Huang, Liang
    • Structural Engineering and Mechanics
    • /
    • 제52권6호
    • /
    • pp.1177-1191
    • /
    • 2014
  • Reinforced concrete (RC) shear walls are one of the most commonly used lateral-load resisting systems in high-rise buildings. RC Parallel redundancy walls studied herein consist of two parts nested to each other. These two parts have different mechanical behaviors and energy dissipation mechanisms. In this paper, experimental studies of four 1/2-scale specimens representing this concept, which are subjected to in-plane cyclic loading, are presented and test results are discussed. Two specimens consist of a wall frame with barbell-shaped walls embedded in it, and the other two consist of a wall frame and braced walls nested each other. The research mainly focuses on the failure mechanism, strength, hysteresis loop, energy dissipation capacity and stiffness of these walls. Results show that the RC parallel redundancy wall is an efficient lateral load resisting component that acts as a "dual" system with good ductility and energy dissipation capacity. One main part absorbs a greater degree of the energy exerted by an earthquake and fails first, whereas the other part can still behave as an independent role in bearing loads after earthquakes.

Seismic response analysis of mega-scale buckling-restrained bracing systems in tall buildings

  • Gholipour, Mohammadreza;Mazloom, Moosa
    • Advances in Computational Design
    • /
    • 제3권1호
    • /
    • pp.17-34
    • /
    • 2018
  • Tall buildings are categorized as important structures because of the large number of occupants and high construction costs. The choice of competent lateral load resisting systems in tall buildings is of crucial importance. Bracing systems have long been an economic and effective method for resisting lateral loads in steel structures. However, there are some potential adverse aspects to bracing systems such as the limitations they inflict on architectural plans, uplift forces and poor performances in compression. in order to eliminate the mentioned problems and for cost optimization, in this paper, six 20-story steel buildings and frames with different types of bracing, i.e., conventional, mega-scale and buckling-restrained bracing (BRB) were analyzed. Linear and modal push-over analyses were carried out. The results pointed out that Mega-Scale Bracing (MSB) system has significant superiority over the conventional bracing type. The MSB system is 25% more economic. Some other advantages of MSB include: up to 63% less drift ratio, up to 38% better performance in lateral displacement, up to 100% stiffer stories, and about 50% smaller uplift forces. Moreover, MSB equipped with BRB attests even a better seismic behavior in the aforementioned parameters.

Seismic performance of low and medium-rise RC buildings with wide-beam and ribbed-slab

  • Turker, Kaan;Gungor, Ilhan
    • Earthquakes and Structures
    • /
    • 제15권4호
    • /
    • pp.383-393
    • /
    • 2018
  • In this study, seismic performance of low and medium-rise RC buildings with wide-beam and ribbed-slab were evaluated numerically. Moment resisting systems consisting of moment and dual frame were selected as structural system of the buildings. Sufficiency of moment resisting wide-beam frames designed with high ductility requirements were evaluated. Upon necessity frames were stiffen with shear-walls. The buildings were designed in accordance with the Turkish Earthquake Code (TEC 2007) and were evaluated by using the strain-based nonlinear static method specified in TEC. Second order (P-delta) effects on the lateral load capacity of the buildings were also assessed in the study. The results indicated that the predicted seismic performances were achieved for the low-rise (4-story) building with the high ductility requirements. However, the moment resisting frame with high ductility was not adequate for the medium-rise building. Addition of sufficient amount of shear-walls to the system proved to be efficient way of providing the target performance of structure.