• 제목/요약/키워드: lateral flow test

검색결과 99건 처리시간 0.02초

변형을 고려한 요트 세일의 2차원 단면 해석 (Analysis of a Two-Dimensional Section of Deforming Yacht Sails)

  • 이희범;이신형;유재훈
    • 대한조선학회논문집
    • /
    • 제48권4호
    • /
    • pp.308-316
    • /
    • 2011
  • Although a yacht sails operate with large displacement due to very thin thickness, many studies for flow around yacht sails have not considered the sail deformation. The sail deformation not only caused a change in the center of effect(CE) on the sail but also a change in the thrust of the sail. The change of the CE and thrust affects the center of lateral resistance(CLR) and side forces of the hull, and the balance of the yacht. These changes affect the motion of the yacht which changes the velocity of the yacht. Thus, when analyzing the flow around yacht sails, the sail deformation should be considered. In the present study, fluid-structure-interaction(FSI) analysis of a two dimensional section of yacht sails was performed to consider the effects of sail deformation on the lift and drag performance. FSI and moving mesh methods were studied. Computational methods were verified using benchmark test cases such as the flow around horizontal and vertical cantilever beams. Shape deformation, pressure distribution, lift forces and separation flow were compared for both rigid and deformable sail.

Clinical evaluation of a rapid diagnostic test kit for detection of canine coronavirus

  • Yoon, Seung-Jae;Seo, Kyoung-Won;Song, Kun-Ho
    • 대한수의학회지
    • /
    • 제58권1호
    • /
    • pp.27-31
    • /
    • 2018
  • Canine coronavirus is a single-stranded RNA virus that causes enteritis in dogs of any age. Coronaviral enteritis is seldom definitively diagnosed, since it is usually much less severe than many other types of enteritis and is self-limiting. Conventional diagnostics for the canine coronaviral enteritis such as polymerase chain reaction (PCR), virus isolation, and electron microscopic examination are inappropriate for small animal clinics due to the complicated experimental processes involved. Therefore, a commercially available lateral flow test kit based on chromatographic immunoassay techniques was tested to evaluate its performance as a first-line diagnostic test kit that could be used in clinics. The coronavirus antigen test kit detected canine coronavirus-infected dogs with 93.1% sensitivity and 97.5% specificity. The detection limit of the test kit was between $1.97{\times}10^4/mL$ and $9.85{\times}10^3/mL$ for samples with a 2-fold serial dilution from $1.25{\times}10^6\;TCID_{50}$ ($TCID_{50}$, 50% tissue culture infectious dose). Additionally, the test kit had no cross-reactivity with canine parvovirus, distemper virus, or Escherichia coli. Overall, the commercially available test kit showed good diagnostic performance in a clinical setting, with results similar to those from PCR, confirming their potential for convenient and accurate use in small animal clinics.

스마트 무인기 TR-S2 형상의 정적 풍동시험 (Static Wind Tunnel Test of Smart Un-manned Aerial Vehicle(SUAV) for TR-S2 Configuration)

  • 최성욱;조태환;정진덕
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.755-762
    • /
    • 2005
  • To evaluate the aerodynamic efficiency of TR-S2 configuration designed by SUDC, wind tunnel tests of $40\%$ scaled model were done in KARI LSWT. The aerodynamic characteristics of plain and Semi-Slotted Flaperon were compared, and vortex generators were installed to improve flow pattern along the wing surface. Effects of the control surface such as elevator, rudder, aileron, and incidence angle of horizontal tail are measured for various testing conditions. Test results showed that Semi-Slotted Flaperon produced more favorable lift, lift/drag, and stall margins and application of vortex generator would be best choice to enhance wing performance. Longitudinal, lateral and directional characteristics of TR-S2 were found to be stable for the pitch and yaw motions.

Wind loads on industrial solar panel arrays and supporting roof structure

  • Wood, Graeme S.;Denoon, Roy O.;Kwok, Kenny C.S.
    • Wind and Structures
    • /
    • 제4권6호
    • /
    • pp.481-494
    • /
    • 2001
  • Wind tunnel pressure tests were conducted on a 1:100 scale model of a large industrial building with solar panels mounted parallel to the flat roof. The model form was chosen to have the same aspect ratio as the Texas Tech University test building. Pressures were simultaneously measured on the roof, and on the topside and underside of the solar panel, the latter two combining to produce a nett panel pressure. For the configurations tested, varying both the lateral spacing between the panels and the height of the panels above the roof surface had little influence on the measured pressures, except at the leading edge. The orientation of the panels with respect to the wind flow and the proximity of the panels to the leading edge had a greater effect on the measured pressure distributions. The pressure coefficients are compared against the results for the roof with no panels attached. The model results with no panels attached agreed well with full-scale results from the Texas Tech test building.

NREL 5 MW 풍력터빈 모형의 후류 유동장에 대한 실험적 연구 (An Experimental Study on Wake Flow-Field of NREL 5 MW Wind Turbine Model)

  • 강승희;유기완
    • 한국항공우주학회지
    • /
    • 제45권2호
    • /
    • pp.85-91
    • /
    • 2017
  • 본 연구에서는 NREL 5 MW 해상풍력터빈 모형의 후류 유동장 분석을 위해 1/86 축소모형을 사용한 실험적 연구를 수행하였다. 정격출력 속도 11.4 m/s와 회전수 1,045 rpm 조건에서 열선풍속계를 사용하여 반경의 6배까지 후류에서 속도 결핍 및 난류도 변화를 측정하는 풍동시험을 수행하였다. 그 결과 풍력터빈의 후류에서의 속도결핍은 횡방향과 수직 방향으로는 반경의 2배 이내에서 회복됨을 볼 수 있었으며, 끝단 와류에 의한 영향은 반경의 5배 이후에는 나타나지 않음을 볼 수 있었다. 또한, 후류의 난류도는 블레이드 끝단 부근에서 크게 나타나며 길이방향으로 반경 거리까지는 급격한 감소가 일어나지만 이 이후부터 반경의 6배까지 유지되었다.

전자부품의 방열방향에 따른 접촉열전도 특성 (Characterization of a Thermal Interface Material with Heat Spreader)

  • 김정균;;이선규
    • 한국정밀공학회지
    • /
    • 제27권1호
    • /
    • pp.91-98
    • /
    • 2010
  • The increasing of power and processing speed and miniaturization of central processor unit (CPU) used in electronics equipment requires better performing thermal management systems. A typical thermal management package consists of thermal interfaces, heat dissipaters, and external cooling systems. There have been a number of experimental techniques and procedures for estimating thermal conductivity of thin, compressible thermal interface material (TIM). The TIM performance is affected by many factors and thus TIM should be evaluated under specified application conditions. In compact packaging of electronic equipment the chip is interfaced with a thin heat spreader. As the package is made thinner, the coupling between heat flow through TIM and that in the heat spreader becomes stronger. Thus, a TIM characterization system for considering the heat spreader effect is proposed and demonstrated in detail in this paper. The TIM test apparatus developed based on ASTM D-5470 standard for thermal interface resistance measurement of high performance TIM, including the precise measurement of changes in in-situ materials thickness. Thermal impedances are measured and compared for different directions of heat dissipation. The measurement of the TIM under the practical conditions can thus be used as the thermal criteria for the TIM selection.

흡연이 치은혈류량에 미치는 영향 (Effect of Smoking on Gingival Blood Flow)

  • 오현정;박병기;신광용;한경윤;김병옥
    • Journal of Periodontal and Implant Science
    • /
    • 제30권2호
    • /
    • pp.471-482
    • /
    • 2000
  • Recent studies have demonstrated that smoking may be one of the most significant risk factors in the development and progression of periodontal disease. Reports have indicated that smoking causes gingival blood flow to be decreased. However, studies on the effects of smoking on gingival blood flow have yielded contradictory results. The purpose of the present study was to determine the effect of smoking on gingival blood flow. One hundred volunteers(fifty non-smokers and fifty smokers) with good general and periodontal health, aged twenties(non-smoker : 22-29 years, mean=25.36, smoker : 23-29 years, mean=26.64) were selected. Laser Doppler flowmetry (floLAB, Moor Instruments Ltd., England) was applied to measure the gingival blood flow of interdental papilla, marginal gingiva, attached gingiva and alveolar mucosa of left and right upper lateral incisors. In smokers, following an overnight abstinence from smoking, gingival blood flow was measured before smoking, immediately after smoking, 1-, 2-, 3-, 4-, 5- and 6- hour after smoking from 9 a.m. to 3:30 p.m. The difference of blood flow in each tissue of non-smokers and that of each measuring time and each tissue of smokers were statistically analyzed by one way ANOVA and Tukey test. And the difference of blood flow between smokers and nonsmokers in each tissue was statistically analyzed by t-test. The results were as follows : 1. Mean blood flow was highest in alveolar mucosa, followed by interdental papilla, attached gingiva and marginal gingiva in both smokers and nonsmokers. There was a statistically significant difference in each tissue(p<0.05) . 2. There was no consistent result between mean blood flow before smoking in smokers and that of nonsmokers in each tissue. 3. There was a statistically significant difference between gingival blood flow at measuring time point and gingival blood flow of smokers in each tissue(p<0.05). The present study suggested that smoking could alter the gingival blood flow, thus might be partly contributed to periodontal destruction.

  • PDF

GREAT 셀을 이용한 삼축압축시험의 수치모사: 예비연구 (Numerical Simulation of Triaxial Compression Test Using the GREAT Cell: Preliminary Study)

  • 박도현;박찬희
    • 터널과지하공간
    • /
    • 제32권3호
    • /
    • pp.219-230
    • /
    • 2022
  • GREAT 셀은 실험실에서 심부지층의 열-수리-역학적 조건을 구현하기 위해 설계된 시험장비로서, 시료 길이방향 축을 중심으로 회전하는 측면의 가압장치를 이용하여 다축 응력장을 생성할 수 있고 균열이 포함된 시료에 대해 유체유동 실험이 가능하다. 본 연구에서는 GREAT 셀을 이용한 삼축압축시험을 수치 해석적으로 모사하고 시료 측면에 작용하는 구속압 조건에 따른 역학적 거동을 분석하였다. 균열이 없는 고분자 재질의 시료에 대한 삼축압축시험 사례를 수치모사하여 실험결과와 비교하였다. 수평 구속압의 균등 및 불균등 조건에서 시료 표면의 변형률(원주변형률)을 분석하였으며, 실험결과와 유사한 경향을 보이는 것으로 검토되었다. 추가로 균열이 포함된 가상의 시료모델을 구성하여 균열면의 마찰 특성 및 형상이 시료 변형에 미치는 영향을 조사하였다.

여수로 유도벽 설계를 위한 접근수로의 2차원 흐름해석 (Two-Dimensional Flow Analysis of Approach Channel for the Design of Spillway Guidewall)

  • 이길성;김남일
    • 한국수자원학회논문집
    • /
    • 제31권4호
    • /
    • pp.491-501
    • /
    • 1998
  • 접근수로의 유황 파악과 안정적인 흐름조건을 만족시키는 여수로 유도벽 설계를 위하여 수치모의를 수행하였다. 복잡한 지형 재현이 용이한 2차원 유한요소모형인 RMA-2를 사용하였으며, 수리모형실험의 결과를 이용하여 모형의 매개변수를 추정하였다. 세부구간과 확장구간으로 나누어서 수치모의를 수행하였으며, 이를 통하여 경계의 영향을 무시할 수 있는 수리모형실험의 상류경계의 위치를 설정하였다. 접근수로 내의 흐름을 안정화시키기 위하여 유도벽의 대안 설계를 하였으며, 이에 대한 수치모의를 통해서 각 대안에 대하여 흐름해석을 하였다. 대안설계에 대한 해석결과, 접근수로 내의 유황이 안정적이며 횡방향 수위편차가 여수로 월류부 전면에서 거의 해소되는 것으로 나타났다.

  • PDF

인천지역 다층지반에 시공된 SCP의 침하거동 분석 (The Settlement Behavior Analysis of SCP of Multi-Layered Ground in Incheon)

  • 윤원섭;김종국;박상준;조철현;채영수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1042-1050
    • /
    • 2008
  • In this study, SCP method was used by purpose to improve loose sand and soft clay that is drilled Sand Compaction Pile in underground. Settlement behavior of field analyzed through SCP method. When sand Compaction Pile drilled in clay, forming composite ground that foundation and Sand Compaction Pile behavior. According to SCP method can expect bearing capacity improvement, Settlement reduction, lateral flow protection. SCP increase the consolidation settlement of ground and it reduce settlement for that purpose increase liquefaction resistance, lateral Resistance. Because SCP had been widely used for sand. Area of Inchon-A by sand compose clay and silt to upper Ground and compose soft clay to under ground. After pre-loading, it measured settlement by extensometer and settlement extensometer that purpose of ground improvement with 13% in replacement ratio. The result analyzed settlement behavior is similar to Multi-layered Ground that it happened to elastic settlement at upper ground and to consolidation settlement at under ground.

  • PDF