• 제목/요약/키워드: lateral dose

검색결과 208건 처리시간 0.023초

발목염좌 급성기에 봉독 약침의 용량에 따른 진통 및 회복에 미치는 효과 (Dose Effects of Bee Venom Pharmacopuncture for the Acute Ankle Sprain in Rats)

  • 양승범;김재효
    • Korean Journal of Acupuncture
    • /
    • 제33권4호
    • /
    • pp.194-203
    • /
    • 2016
  • Objectives : The aim of this study was to observe the dose-dependent effects of bee venom (BV) pharmacopuncture on the serious ankle sprain in rats. Methods : The grade III ankle sprain was produced by surgically damaging the lateral ligaments complex of Sprague-Dawley rats. BV pharmacopuncture with the different doses($5{\mu}g/kg$, $10{\mu}g/kg$, $50{\mu}g/kg$) were treated on the different acupoints(GB34, GB39 and GB42) of the affected hind limb, respectively. By measuring foot weight bearing force ratio(FWBFR), the pain levels by ankle sprain and the pain recovery for 7 days were observed under BV pharmacopuncture on each acupoint. Results : In the normal and ankle sprained rat, the BV single administration decreased FWBFR in a dose - dependent pattern. The higher the BV dose, the higher the pain resulted in the normal and the sprained ankles. Especially, the dose - dependent effects of BV resulted in the most pronounced decrease in FWBFR in GB34. The recovery of FWBFR was shown at the low dose($5{\mu}g/kg$) BV and the effect was most remarkable in the BV of GB34, but the others showed no recovery effect compared with the control group. Conclusions : BV pharmacopuncture does not exhibit analgesic effects in acute phase of ankle sprain. However, the recovery of ankle sprain was more effective than the natural recovery in the case of low dose of BV repeated over time. Considering this, it is presumed that it would be important to select appropriate clinic guidelines for acute phase of ankle sprain.

유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가 (Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter)

  • 김재겸;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.1-11
    • /
    • 2016
  • 본 연구는 디지털 방사선촬영 시스템에서 요추검사 시 조사야 크기에 따른 주변 장기선량과 요추 영상의 화질 변화를 정량화하여 의료피폭 저감화를 위한 자료를 제공하고자 하였다. 요추검사 시 조사야 크기는 $8^{\prime\prime}{\times}17^{\prime\prime}$에서 $14^{\prime\prime}{\times}17^{\prime\prime}$ 크기까지 변화하였으며, RANDO 팬텀을 대상으로 요추 전-후방향, 측방향 검사를 실행하였다. 장기선량은 간, 위, 췌장, 신장, 생식선을 선택하여 유리선량계로 측정하였으며, Image J로 영상 분해능을 비교 분석하였다. 전-후방향 촬영에서 요추의 주변 장기선량은 조사야 크기가 작아짐에 따라 감소하였으나, 생식선에서는 조사야의 가로축 길이가 1" 작아질 때마다 3.83%로 감소율의 변화가 없었다. 측방향 촬영에서 간, 신장과 같이 표면과 가까운 장기에서 장기선량은 높은 선량이 나타났으나, 조사야의 가로축 길이가 1" 작아질 때마다 감소율이 5% 이내로 나타났다. 그러나 생식선에서는 조사야의 가로축 길이가 1" 작아질 때마다 감소율이 24.34%로 나타났다. 조사야 내, 외부에 대한 선량 차이는 간에서 $549.8{\mu}Gy$, 위에서 $264.6{\mu}Gy$로 감소하였으나, 생식선에서는 평균 $1,135.1{\mu}Gy$로 큰 변화가 없었다. 조사야 크기에 따른 영상은 전-후방향 촬영에서 $9^{\prime\prime}{\times}17^{\prime\prime}$, 측방향 촬영에서 $10^{\prime\prime}{\times}17^{\prime\prime}$ 이하의 크기에서 30 dB 이상으로 영상의 질적 차이를 구분할 수 없었다. 따라서 요추검사는 다른 검사 부위보다 주변장기들이 많이 포함하고 있기 때문에 불필요한 환자의 피폭선량을 줄이고 양질의 영상을 얻기 위하여 조사야 크기 설정에 관한 권고기준안이 제시되어야 할 것으로 사료된다.

n-Alkanols가 소의 대뇌피질로부터 분리한 Synaptosomal Plasma Membrane Vesicles의 측방확산운동 범위와 속도에 미치는 영향 (The Effect of n-Alkanols on the Lateral Diffusion of Synaptosomal Plasma Membrane Vesicles Isolated from Bovine Cerebral Cortex)

  • 정인교;강정숙;윤일
    • 대한약리학회지
    • /
    • 제29권1호
    • /
    • pp.157-163
    • /
    • 1993
  • n-Alkanols의 분자적 약리작용기전 탐구에 기초자료를 제공하기 위하여 소의 신선한 대뇌피질로부터 분리한 synaptosomal plasma membrane vesicles (SPMV) 지질 이중층의 측방확산운동에 미치는 n-alkanols의 영향을 형광 probe법으로 검색하였다. n-Alkanols는 SPMV 지질 이중층의 측방확산운동 범위와 속도를 농도 의존적으로 증가시켰고 1-nonanol까지는 탄소수가 두개 증가될 때마다 그 효력은 약 10배 가량 증가되었으나 탄소수 10개인 1-decanol의 효력은 오히려 감소되는 경향을 나타내었다.

  • PDF

감각신경전도 이상을 동반한 근위축성측색경화증 (Amyotrophic Lateral Sclerosis Combined with Abnormal Sensory Nerve Conduction)

  • 서상혁;안재영;이택준;서연림;신경진;김병준
    • Annals of Clinical Neurophysiology
    • /
    • 제7권2호
    • /
    • pp.133-137
    • /
    • 2005
  • Underlying neuropathies combined with amyotrophic lateral sclerosis (ALS) cast doubt on the diagnosis of ALS when present. Abnormal sural nerve conductions were found in 3 patients with clinically definite ALS. Pathologically demyelinating, axonal, or vasculitic neuropathy was suggested respectively. High dose oral corticosteroid had no effect and clinical courses were deteriorating in all the patients. The causes of combined neuropathies were unclear. Possibility of direct consequence of ALS, concomitant neuropathies, or rare variants of ALS should be considered in these cases.

  • PDF

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

악관절 단층촬영시의 두경부 주요 기관의 흡수선량 (Absorbed Doses in Organs of the Head and Neck from Conventional Temporomandibular Joint Tomography)

  • 조봉혜
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.411-416
    • /
    • 1999
  • Purpose : This study was done to evaluate the absorbed doses in organs of the head and neck for the conventional temporomandibular joint tomography. Materials and Methods : Dosimetry was performed with 32 LiF thermoluminescent dosimeters, which were placed in a tissue-equivalent phantom when the temporomandibular joint was examined by both lateral and frontal temporomandibular joint tomography. Results : For lateral tomography, parotid gland and preauricular area towards tube showed relatively high absorbed dose of 1056.9 μGy and 519.9 μGy respectively. For frontal tomography, the two largest absorbed doses were 259.2 μGy in orbit towards tube and 212.0 μGy in lens towards tube. Conclusion : Conventional temporomandibular joint tomography showed relatively low absorbed doses on critical organs. Thus, responsible use of it may not be limited.

  • PDF

금속 나노 스탬퍼 점착방지막으로서의 자기조립 단분자막 특성 연구 (Study on Properties of Self-Assembled Monolayer as Anti-adhesion Layer on Metallic Nano Stamper)

  • 최성우;강신일
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.367-370
    • /
    • 2003
  • In this study, application of SAM (self-assembled monolayer) to nano replication process as an anti-adhesion layer was presented to reduce the surface energy between the nano mold and the replicated polymeric nano patterns. The electron beam lithography was used for master nano patterns and the electorforming process was used to fabricate the nickel nano stamper. Alkanethiol SAM as an anti-adhesion layer was deposited on metallic nano stamper using solution deposition method. To analyze wettability and adhesion force of SAM, contact angle and LFM (Lateral Force Microscopy) were measured at the actual processing temperature and pressure for the case of nano compression molding and at the actual UV dose for the case of nano UV molding. It was found that the surface energy due to SAM deposition on the nickel nano stamper markedly decreased and the quality of SAM on the nickel stamper maintained under the actual molding environments.

  • PDF

유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구 (A Study on Dose Reduction in Infant Skull Radiography)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.387-392
    • /
    • 2017
  • 영 유아는 사건, 사고 및 교통사고 또는 질병으로 인해 머리에 골절 및 혈관파열, 피부에 상처를 받아 병원에 내원하여 영상의학과에서 머리 검사인 전 후(Skull AP) 및 측면(Skull LAT) 촬영을 받게 된다. 머리검사에서 성인 머리(Skull) 촬영은 격자를 이용하여 촬영에 적용하면 방사선 2차선을 제거하여 영상의 대조도를 높인다. 그러나 방사선 노출조건 중 관전압을 8~10 kVp 높게 주어야 하며 환자피폭이 증가한다. 본 연구는 영 유아 머리촬영시 격자(grid)를 이용하지 않고 동등한 영상을 얻을 수 있다면 피폭선량 감소 및 Grid Cut off에 의한 아티팩트를 방지할 수 있어 연구해 보았다. 연구자는 방사선계측기 이용 방사선선량을 측정 하고 의료영상평가 방법 중에서 주관적 평가(ROC,receiver operationg characteristic)을 해 보았다. 결과에서 격자를 이용하지 않고 촬영하면 환자 피폭선량 감소와 영상 평가에서도 영 유아의 머리 촬영시 격자를 이용하지 않고 촬영을 하게 되면 머리 전 후촬영에서 0.019 mGy 와 측면촬영 0.02 mGy 피폭선량 감소가 있었고 영상평가에서도 4점을 높게 받았다. 결론으로 병원에 내원한 영 유아 머리촬영은 격자를 이용하지 않고 촬영하면 피폭 선량 감소 및 영상 아티팩트인 Grid Cut off을 방지 할 수 있고 엑스선관 수명이 연장되리라 사료된다.

Organ Dose Conversion Coefficients Calculated for Korean Pediatric and Adult Voxel Phantoms Exposed to External Photon Fields

  • Lee, Choonsik;Yeom, Yeon Soo;Griffin, Keith;Lee, Choonik;Lee, Ae-Kyoung;Choi, Hyung-do
    • Journal of Radiation Protection and Research
    • /
    • 제45권2호
    • /
    • pp.69-75
    • /
    • 2020
  • Background: Dose conversion coefficients (DCCs) have been commonly used to estimate radiation-dose absorption by human organs based on physical measurements of fluence or kerma. The International Commission on Radiological Protection (ICRP) has reported a library of DCCs, but few studies have been conducted on their applicability to non-Caucasian populations. In the present study, we collected a total of 8 Korean pediatric and adult voxel phantoms to calculate the organ DCCs for idealized external photon-irradiation geometries. Materials and Methods: We adopted one pediatric female phantom (ETRI Child), two adult female phantoms (KORWOMAN and HDRK Female), and five adult male phantoms (KORMAN, ETRI Man, KTMAN1, KTMAN2, and HDRK Man). A general-purpose Monte Carlo radiation transport code, MCNPX2.7 (Monte Carlo N-Particle Transport extended version 2.7), was employed to calculate the DCCs for 13 major radiosensitive organs in six irradiation geometries (anteroposterior, posteroanterior, right lateral, left lateral, rotational, and isotropic) and 33 photon energy bins (0.01-20 MeV). Results and Discussion: The DCCs for major radiosensitive organs (e.g., lungs and colon) in anteroposterior geometry agreed reasonably well across the 8 Korean phantoms, whereas those for deep-seated organs (e.g., gonads) varied significantly. The DCCs of the child phantom were greater than those of the adult phantoms. A comparison with the ICRP Publication 116 data showed reasonable agreements with the Korean phantom-based data. The variations in organ DCCs were well explained using the distribution of organ depths from the phantom surface. Conclusion: A library of dose conversion coefficients for major radiosensitive organs in a series of pediatric and adult Korean voxel phantoms was established and compared with the reference data from the ICRP. This comparison showed that our Korean phantom-based data agrees reasonably with the ICRP reference data.

세로 자기장에서 6 MeV 전자선의 선량분포에 관한 몬데칼로 계산 (Monte Carlo Calculation of the Dose Profiles for a 6 MeV Electron Beam with Longitudinal Magnetic Fields)

  • 오영기;정동혁;신교철;김기환;김정기;김진기;김부길;이정옥;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.195-201
    • /
    • 2002
  • 측방 산란이 상대적으로 많은 6 MeV 전자선에 대하여 세로 자기장에서 반음영의 변화를 몬테칼로 계산을 이용하여 연구하였다. 전자의 물질과의 상호작용 계산에서 외부 자기장의 효과를 반열하기 위하여 자기장에서 전자의 방향변화에 관한 알고리즘을 개발하여 EGS4 시스템에 삽입하였다. 완성된 코드를 이용하여 점선원 기하구조를 설정하고 SSD 100 cm에서 직경 5 cm인 전자선에 대하여 0-3 T의 세로 자기장이 걸려있는 팬텀속 1.5 cm, 2.0 cm, 2.4 cm 깊이에서의 빔 프로파일을 계산하였다. 자기장의 세기에 따른 반음영의 감소를 나타내기 위해 같은 질이에서의 기존 반음영의 폭과 자기장에 의한 반음영 폭의 감소 비로 반음영 감소율(PRR)을 정의하였다. 계산결과 팬텀속 1.5 cm, 2.0 cm, 2.4 cm 깊이에 대하여 자기장의 세기가 2 T인 경우에 PRR은 각각 27%, 36%, 36%로 나타났으며, 3 T인 경우에는 각각 46%, 50%, 50%로 나타났다 0.5 T와 1 T에서는 자기장의 효과가 매우 미약하였다. 이 결과는 6 MeV 전자선의 경우에 2 T 이상의 자기장을 세로방향으로 인가한는 경우에 측방산란된 전자들이 자기장에 의하여 편향되면서 반음영의 폭이 크게 줄어드는 것으로 해석할 수 있다. 결론적으로 전자선치료에서 세로 자기장을 병행하는 경우에 조사면 가장자리의 선량감소가 보상됨으로써 치료효과의 증대를 기대할 수 있다.

  • PDF