• Title/Summary/Keyword: lateral dose

Search Result 209, Processing Time 0.025 seconds

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

Administration of ethylenethiourea during organogenesis periods in pregnant rats. 1. Effects on teratogenic effects, amino acids and protein concentrations in amniotic fluids (Ethylenethiourea의 임신랫트에 있어서 기관형성기 투여시험 1. 기형발생과 양수내의 아미노산 및 단백질 함량에 미치는 영향)

  • Kim, Sung-hoon;Huh, Rhin-soo
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.4
    • /
    • pp.411-418
    • /
    • 1991
  • This study was carried out to investigate the amino acid and protein concentrations in amniotic fluid and the potency of the teratogenic effect of ethylenethiourea(2-imidazolidinethione, ETU) in the fetuses due to different dose amounts of this compound. The S.P.F. Sprague-Dawley female rats(10 weeks) were used in this study and these animals were divided into four groups; control group(25pregnant female rats), group I (dosed ETU from day 7 to day 17 of gestation at 10mg/kg/day), group II (dosed ETU from day 7 to day 17 of gestation at 30mg/kg/day), group III (dosed ETU from day 7 to day 17 of gestation at 50mg/kg/ day). 250mg/100mg ETU in group I, 750mg/100ml ETU in group II and 1,250mg/100ml ETU in group III were administered 4ml/kg 13.W by oral route. The results obtained were summarized as follows; 1. The anomalies of the external examination werf meningocele in the head, kinky tail, clubfoot and sharp tail.(Meningocele, in group III, significantly increased from control value at p<0.001). 2. The skeletal variations and delayed ossification were Lumbar ribs, asymmetric sternebrae, asymmetric 13th rib and delayed ossification of skull. Asymmetric sternebrae(group III ) was significantly increased from control value at p<0.05 and delayed ossification of skull (group II and III ) were significantly increased from control value at p<0.05 and p<0.01, respectively. 3. The internal soft tissue anomalies were hydroencephaly of 3th lateral ventricle, dilatation of ureter, dilatation of renal pelvis and cleft palate. (Hydroencephaly, 28.1% in group I, 88.3% in group II and 100% in group III ). 4. Protein values in amniotic fluids are not significantly decreased in 10mg/kg group but significantly(p<0.05) decreased in 30mg/kg group and 50mg/kg group from control group. 5. In the levels of amino acid in amniotic fluids, the levels of glntamic acid, iso-lencine, leucine, tyrosine and phenylalanine of 10mg/kg group are significantly decreased from control group. In 50mg/kg group, except for glycine, valine and methionine, all amino acid levels are significantly(p<0.05) decreased from control group.

  • PDF

The Anti-tumor Effect of Polysaccharide from the Leaves of Panax Ginseng C.A. Meyer(MB40) in a Murine Squamous Cell Carcinoma Model (편평세포암 동물 모델에서 고려인삼잎-다당체(MB40)의 항암치료효과)

  • Joo, Eun-Jung;Choi, Jun;Chung, Eun-Jae;Hong, Seok-Jin;Cho, Jae-Gu;Baek, Seung-Kuk;Woo, Jeong-Soo;Jung, Kwang-Yoon;Kwon, Soon-Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.25 no.1
    • /
    • pp.3-7
    • /
    • 2009
  • Background and Objectives : Panax ginseng C.A. Meyer is a medical plant that has been widely utilized as a tonic and nutritional agent since ancient times in Korea. Ginseng has anti-metastatic property of cancer and immunomodulating activity. The novel acidic polysaccharide compound(MB40) was isolated from the leaves of Panax ginseng C.A. Meyer. To determine immunomodulating activities of MB40, we evaluate anti-cancer and anti-metastatic effects of MB40 in tumor bearing immune competent mice. Material and Methods : C3H mice were divided into three equal groups(Cisplatin treatment group, MB40 treat-ment group, Cisplatin and MB40 treatment group) and were transplanted SCC(Squamous Cell Carcinoma) cells(2${\times}$106) to the lateral side of abdomen. From day 4 after transplantation, MB40 was administrated at dose of 10mg/kg, respectively, every other day by intratumoral injection. Cisplatin was systemically administrated at doses of 1mg/kg, respectively, every week by intraperitoneal injection. Results : 5 days after administration, tumors can be palpated in every mice group. After 13 days of administration, the mice group to which MB40 were administrated exhibited reduction in tumor size respectively, compared to cisplatin group. Overall status of mice such as body weight and activity were superior in MB40 group than cisplatin group. Conclusion : The result of this study indicates MB40 may have significant therapeutic effect and decreases complications induced by systemic chemotheraphy. MB40 may be developed as a novel and potent immunotropics to improve the cell immune system and anti-cancer drug for the treatment of cancer patients in head and neck squamous cell carcinoma.

A Study on the Vibration Characteristics of Subway Structure by Train Load (열차 하중에 의한 지하철 구조물의 진동 특성에 관한 연구)

  • Park, Sung Woo;Park, Seung Su;Hwang, In Baek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.107-115
    • /
    • 2011
  • In this study, the vibration analysis of the underground box structures induced train movement is studied. In order to perform these analysis, dynamic data, which was measured when subway is in service, are gained by attaching accelerometers on the structure such as lower beam, lateral wall and upper slab. Also, accelerometers are attached on the lower beams and side walls of the gravel ballast and concrete ballast sections in order to compare vibration due to ballast materials. The vibration results of upper slabs and lower beams reveal that the vibration on the upper slabs is greater than the lower beams. Also, the results of the crack gauge on the upper slab show that crack width dose not change due to vibration, These means that the effect of the vibration on the structure is very limited. In order to evaluate the vibration of the structure, acceleration unit is converted to velocity unit comparing with the existing velocity data gained from the platforms.

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

Comparison of Intensity-modulated Radiation Therapy (IMRT), Uniform Scanning Proton Therapy (USPT), and Intensity-modulated Proton Therapy (IMPT) for Prostate Cancer: A Treatment Planning Study (전립선 암 환자의 IMRT, USPT, 및 IMPT 기법에 따른 치료효과 비교)

  • Son, Kihong;Cho, Seungryong;Kim, Jin Sung;Han, Youngyih;Ju, Sang Gyu;Ahn, Sung Hwan;Shin, Eunhyuk;Shin, Jung Suk;Park, Won;Pyo, Hongryul;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.154-161
    • /
    • 2013
  • This study assessed compared photon and proton treatment techniques, such as intensity modulated radiation therapy (IMRT), uniform scanning proton therapy (USPT), and intensity modulated proton therapy (IMPT), for a total of 10 prostate cancers. All treatment plans delivered 70 Gy to 95% of the planned target volume in 28 fractions. IMRT plans had 7 fields for the step and shoot technique, while USPT and IMPT plans employed two equally weighted, parallel-opposed lateral fields to deliver the prescribed dose to the planned target. Inverse planning was then incorporated to optimize IMPT. The homogeneity index (HI) and conformity index (CI) for the target and the normal tissue complication probability (NTCP) for organ at risk (OAR) were calculated. Although the mean HI and CI for target were not significantly different for each treatment techniques, the NTCP of the rectum was 2.233, 3.326, and 1.707 for IMRT, USPT, and IMPT, respectively. The NTCP of the bladder was 0.008, 0.003, and 0.002 respectively. The NTCP values at the rectum and bladder were significantly lower using IMPT. Our study shows that using proton therapy, particularly IMPT, to treat prostate cancer could be beneficial compared to 7-field IMRT with similar target coverage. Given these results, radiotherapy using protons, particularly optimized IMPT, is a worthwhile treatment option for prostate cancer.

A Case of the Shoulder-Hand Syndrome Caused by a Crush Injury of the Shoulder (견관절부 외상후 발생된 Shoulder-Hand Syndrome)

  • Jeon, Jae-Soo;Lee, Sung-Keun;Song, Hoo-Bin;Kim, Sun-Jong;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.2 no.2
    • /
    • pp.155-166
    • /
    • 1989
  • Bonica defined, that reflex sympathetic dystrophy (RSD) may develop pain, vasomotor abnoramalities, delayed functional recovery, and dystrophic changes on an affected area without major neurologic injury following trauma, surgery or one of several diseased states. This 45 year old male patient had been crushed on his left shoulder by a heavily laden rear car, during his job street cleaning about 10 years ago (1978). At first the pain was localizea only to the site of injury, but with time, it spreaded from the shoulder to the elbow and hand, with swelling. X-ray studies in the local clinic, showed no bone abnormalities of the affected site. During about 10 years following the injury, the had recieved several types of treatments such as nonsteroidal analgesics, steroid injections into the glenoidal cavity (10 times), physical therapy, some oriental herb medicines, and acupuncture over a period of 1~3 months annually. His shoulder pain and it's joint dysfunction persisted with recurrent paroxysmal aggrevation because of being mismanaged or neglected for a sufficiently long period these fore permiting progression of the sympathetic imbalance. On July 14 1988 when he visited our clinic. He complained of burning, aching and had a hyperpathic response or hyperesthesia in touch from the shoulder girdle to the elbow and the hand. Also the skin of the affected area was pale, cold, and there was much sweating of the axilla and palm, but no edema. The shoulder girdle was unable to move due to joint pain with marked weakness. We confirmed skin temperatures $5^{\circ}C$ lower than those of the unaffected axilla, elbow and palm of his hand, and his nails were slightly ridged with lateral arching and some were brittle. On X-ray findings of both the shoulder AP & lateral view, the left humerus and joint area showed diffuse post-traumatic osteoporosis and fibrous ankylozing with an osteoarthritis-like appearance. For evaluating the RSD and it's relief of pain, the left cervical sympathetic ganglion was blocked by injecting 0.5% bupivacaine 5 ml with normal saline 5 ml (=SGB). After 15 minutes following the SGB, the clinical efficacy of the block by the patients subjective score of pain intensity (=PSSPI), showed a 50% reduction of his shoulder and arm pain, which was burning in quality, and a hyperpathic response against palpation by the examiner. The skin temperatures of the axilla and palm rose to $4{\sim}5^{\circ}C$ more than those before the SGB. He felt that his left face and upper extremity became warmer than before the SGB, and that he had reduced sweating on his axilla and his palm. Horner's sign was also observed on his face and eyes. But his deep shoulder joint pain was not improved. For the control of the remaining shoulder joint pain, after 45 minutes following the SGB, a somatic sensory block was performed by injecting 0.5% bupivacaine 6 ml mixed with salmon calcitonin, $Tridol^{(R)}$, $Polydyn^{(R)}$ and triamcinolone into the fossa of the acromioclavicular joint region. The clinical effect of the somatic block showed an 80% releif of the deep joint pain by the PSSPI of the joint motion. Both blocks, as the above mentioned, were repeated a total of 28 times respectively, during 6 months, except the steroid was used just 3 times from the start. For maintaining the relieved pain level whilst using both blocks, we prescribed a low dose of clonazepam, prazocin, $Etravil^{(R)}$, codeine, etodolac micronized and antacids over 6 months. The result of the treatments were as follows; 1) The burning, aching and hyperpathic condition which accompanied with vaosmotor and pseudomotor dysfunction, disappeared gradually to almost nothing, within 3 weeks from the starting of the blocks every other day. 2) The joint disability of the affected area was improved little by little within 6 months. 3) The post-traumatic osteoporosis, fibrous ankylosis and marginal sclerosis with a narrowed joint, showed not much improvement on the X-ray findings (on April 25, 1989) 10 months later in the follow-up. 4) Now he has returned to his job as a street cleaner.

  • PDF

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.

The Results of Hvperfractionated Radiation Therapy Combined with Taxol for Paraaortic Node Recurrence in Cervix Cancer (대동맥주위 림프절에 재발된 자궁경부암에서 Taxol을 병행한 과분할 방사선치료의 결과)

  • Kim, Jun-Sang;Jang, Ji-Young;Kim, Jae-Sung;Kim, Sam-Yong;Cho, Moon-June
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.27-31
    • /
    • 2000
  • Purpose : The aim of this study was to investigate treatment results, toxicity and efficacy of hypefractionated radiation therapy combined with paclitaxel for paraaortic node recurrence in cervix cancer. Materials and Methods: Between September 1997 to March 1999, 12 patients with paraaortic node recurrence in cervix cancer who previously received radical or postoperative radiotherapy were treated with hypefractionated radiation therapy combined with paclitaxel. Of these, 2 patients who irradiated less than 30 Gy were excluded, 10 patients were eligible for this study. Median age was 51 years. Initial FIGO stage was 1 stage IBI, 2 stage IIA, 7 stage IIB. For initial treatment, 7 patients received radical radiotherapy and 3 received postoperative radiotherapy. The paraaortic field encompassed the gross recurrent disease with superior margin at T12, and inferior margin was between L5 and S1 with gap for previously pelvic radiation field. The radiation field was initially anterior and posterior opposed field followed by both lateral field. The daily dose was 1.2 Gy, twice daily fractions, and total radiotherapy dose was between 50.4 and 60 Gy(median, 58.8 Gy). Concurrent chemotherapy was done with paclitaxel as a radiosensitizer. Dose range was from 20 mg/m$^{3}$ to 30 mg/m$^{3}$ (median, 25 mg/m$^{3}$), and cycle of chemotherapy was from 3 to 6 (median, 4.5 cycle). Follow-up period ranged from 3 to 21 months. Results : Interval between initial diagnosis and paraaortic node recurrence was range from 2 to 63 months (median, 8 months). The 1 year overall survival rate and median survival were 75$\%$ and 9.5 months, respectively. The 1 year disease free survival rate and median disease free survival were 30$\%$ and 7 months, respectively. At 1 month after treatment, 4 (40$\%$) achieved a complete response and 6 (60$\%$) experienced a partial response and all patients showed response above the partial response. There was distant metastasis in 6 patients and pelvic node recurrence In 2 patients after paraaortic node irradiation. There was 2 patients with grade 3 to 4 leukopenla and 8 patients with grade 1 to 2 nausea/ vomiting which was usually tolerable with antlemetic drug. There was no chronic complication in abdomen and pelvis during follow up period. Conclusion : hypefractionated radiation therapy combined with paclitaxel chemotherapy diosensitizer showed high response rate and few complication rate in paraaortic node recurrence in cervix cancer Therefore, present results suggest that hypefractionated radiation therapy combined with paclitaxel chemotherapy can be used as optimal treatment modality in this patients.

  • PDF