• Title/Summary/Keyword: lateral dose

Search Result 209, Processing Time 0.244 seconds

A STUDY OF GOLDEN PROPORTION APPLICATION IN KOREAN NORMAL DENTITION (조화된 치열의 황금분할에 관한 연구)

  • Ryu, Seong-Hee;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.93-106
    • /
    • 1987
  • The purpose of this study was to investigate the fittness of Golden relation items was advocated by Ricketts whether or not it is applicable to the young adult Korean dentitions and also to evaluate the several new Golden relation items conducted by the author. The material was consisted of 81 dental casts (34 male, 47 female) with ideal occlusion, which never undergone orthodontic, prosthodontic procedures. Measurements were made on the arch dimensions using sliding caliper (Mitutoyo. Co) and data were computerized and analyzed. The findings of this study were as follows, 1. The Golden proportion advocated by Ricketts dose not seem to directly applicable to the Korean normal dentition, however, the modification from the Ricketts' original shows the Golden proportion as follow: A first series of progressive Golden relations was found on the Golden ratio among the lower central incisors width, the inter mesioincisal width of the upper lateral incisors, and the upper first premolars width. A second series was found on the Golden ratio among the lower lateral incisors width, lower inter canine tips width and theupper first molar distal cusp tips width. A third series was found on the Golden ratio between the inter distal aspect width of e lower canine and the mesial cusp tips width of the lower second molars or inter cusp tips width of upper second premolars. 2. In addition to Ricketts' original, 4 new Golden proportions were found in young adult Korean dentition, these are as follows; The tips of lower canine width had Golden relation with the width of the upper first premolar buccal cusp tips or the width of the lower first molar central fossae. The distal aspect of the lower first premolars had Golden relation with the buccal surface widths of the lower or upper second molars. The width of upper lateral incisors had Golden relation with the upper second molar height. The width of the lower canine tips had Golden relation with the lower second molar height.

  • PDF

Effects of Chlorpromazine·HCl on the Structural Parameters of Bovine Brain Membranes

  • Jang, Hye-Ock;Jeong, Dong-Keun;Ahn, Shin-Ho;Yoon, Chang-Dae;Jeong, Soo-Cheol;Jin, Seong-Deok;Yun, Il
    • BMB Reports
    • /
    • v.37 no.5
    • /
    • pp.603-611
    • /
    • 2004
  • Fluorescence probes located in different membrane regions were used to evaluate the effects of chlorpromazine HCl on structural parameters (transbilayer lateral mobility, annular lipid fluidity, protein distribution, and lipid bilayer thickness) of synaptosomal plasma membrane vesicles (SPMVs) isolated from bovine cerebral cortex. The experimental procedure was based on the selective quenching of 1,3-di(1-pyrenyl)propane (Py-3-Py) by trinitrophenyl groups, radiationless energy transfer from the tryptophan of membrane proteins to Py-3-Py, and energy transfer from Py-3-Py monomers to 1-anilinonaphthalene-8-sulfonic acid (ANS). In this study, chlorpromazine HCl decreased the lateral mobility of Py-3-Py in a concentration dependent-manner, showed a greater ordering effect on the inner monolayer than on the outer monolayer, decreased annular lipid fluidity in a dose dependent-manner, and contracted the membrane lipid bilayer. Furthermore, the drug was found to have a clustering effect on membrane proteins.

Analysis of Small-Field Dosimetry with Various Detectors

  • Park, So-Yeon;Choi, Byeong Geol;Lee, Dong Myung;Jang, Na Young
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.164-172
    • /
    • 2018
  • We evaluated the performance of various detectors for small-field dosimetry with field sizes defined by a high-definition (HD) multileaf collimator (MLC) system. For small-field dosimetry, diodes referred to as "RAZOR detectors," MOSFET detectors, and Gafchromic EBT3 films were used in this study. For field sizes less than $1{\times}1cm^2$, percent depth doses (PDDs) and lateral profiles were measured by diodes, MOSFET detectors, and films, and absolute dosimetry measurements were conducted with MOSFET detectors. For comparison purposes, the same measurements were carried out with a field size of $10{\times}10cm^2$. The dose distributions were calculated by the treatment planning system Eclipse. A comparison of the measurements with calculations yielded the percentage differences. With field sizes less than $1{\times}1cm^2$, it was shown that most of the percentage difference values were within 5% for 6-MV and 15-MV photon beams with the use of diodes. The measured lateral profiles were well matched with those calculated by Eclipse as the field sizes increased. Except for the depths of 0.5 cm and 20 cm, there was agreement in terms of the absolute dosimetry within 10% when MOSFET detectors were used. There was good agreement between the calculations and measurements conducted using diodes and EBT films. Both diode detectors and EBT3 films were found to be appropriate options for relative measurements of PDDs and for lateral profiles.

Calculation of depth dose for irregularly shaped electron fields (부정형 전자선 조사면의 심부선량과 출력비의 계산)

  • Lee, Byoung-Koo;Lee, Sang-Rok;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.79-84
    • /
    • 2002
  • The main cause factor for effective the output, especially in small & irregular shaped field of electron beam therapy, are collimation system, insert block diameter and energy. In the absorption deose of treatment fields, we should consider the lateral build-up ratio (LBR), which the ratio of dose at a point at depth for a given circular field to the dose at the same point for a 'broad-field', for the same incident fluence and profile. The LBR data for a small circular field are used to extract radial spread of the pencil beam, ${\sigma}$, as a function of depth and energy. It's based on elementary pencil beam. We consider availability of the factor, ${\sigma}$, in the small & irregular fields electron beam treatment.

  • PDF

Effect of Mixture of Recombinant Human Bone Morphogenic Protein-2 and Demineralized Bone Matrix in Lateral Lumbar Interbody Fusion

  • Jun Ik Son;Young-Seok Lee;Myeong Jin Ko;Seong-Hyun Wui;Seung Won Park
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.3
    • /
    • pp.354-363
    • /
    • 2024
  • Objective : This study aims to determine the optimal dose of recombinant-human bone morphogenic protein-2 (rhBMP-2) for successful bone fusion in minimally invasive lateral lumbar interbody fusion (MIS LLIF). Previous studies show that rhBMP is an effective alternative to autologous iliac crest bone graft, but the optimal dose remains uncertain. The study analyzes the fusion rates associated with different rhBMP doses to provide a recommendation for the optimal dose in MIS LLIF. Methods : Ninety-three patients underwent MIS LLIF using demineralized bone matrix (DBM) or a mixture of rhBMP-2 and DBM as fusion material. The group was divided into the following three groups according to the rhBMP-2 usage : group A, only DBM was used (n=27); group B, 1 mg of rhBMP-2 per 5 mL of DBM paste (n=41); and group C, 2 mg of rhBMP-2 per 5 mL of DBM paste (n=25). Demographic data, clinical outcomes, postoperative complication and fusion were assessed. Results : At 12 months post-surgery, the overall fusion rate was 92.3% according to Bridwell fusion grading system. Groups B and C, who received rhBMP-2, had significantly higher fusion rates than group A, who received only DBM. However, there was no significant increase in fusion rate when the rhBMP-2 dosage was increased from group B to group C. The groups B and C showed significant improvement in back pain and Oswestry disability index compared to the group A. The incidence of screw loosening was decreased in groups B and C, but there was no significant difference in the occurrence of other complications. Conclusion : Usage of rhBMP-2 in LLIF surgery leads to early and increased final fusion rates, which can result in faster pain relief and return to daily activities for patients. The benefits of using rhBMP-2 were not significantly different between the groups that received 1 mg/5 mL and 2 mg/5 mL of rhBMP-2. Therefore, it is recommended to use 1 mg of rhBMP-2 with 5 mL of DBM, taking both economic and clinical aspects into consideration.

Influence of Intraventricular Ouabain on the Renal Function of the Rabbit (가토(家兎) 신장기능(腎臟機能)에 미치는 측뇌실내(側腦室內) Ouabain의 영향(影響))

  • Lee, Shin-Woong
    • The Korean Journal of Pharmacology
    • /
    • v.12 no.1
    • /
    • pp.31-44
    • /
    • 1976
  • It has been reported that many of the effects of digitalis glycosides could be mediated partly through the central nervous system. In this study the effects of ouabain given directly into the lateral ventricle of the brain on the renal function of the rabbit were investigated. Intraventricular ouabain elicited antidiuresis in doses ranging from 0.1 to $3\;{\mu}g$, exhibiting a rough dose-response relationship, and decreased the renal plasma flow, glomerular filtration rate and urinary excretion of sodium and potassium, concomitant with the decrease of urine flow. These decreases in urine flow, excretory rate of electrolytes significantly correlated with the decrease in renal plasma flow or glomerular filtration rate, suggesting that the antidiuresis might have been induced by the hemodynamic changes. Intravenous ouabain in a dose of $1\;{\mu}g$ did not affect the renal function. Systemic blood pressure as well as cardiac activity was not affected by the intraventricular ouabain. Effects of the intraventricular ouabain on renal function were abolished by the intravenous phentolamine-pretreatment but not affected by intraventricular phentolamine-pretreatment. Neither vasopressin infusion nor hydration did affect the renal effects of intraventricular ouabain. From these observations, it is suggested that the antidiuresis of intraventricular ouabain is induced by the increased sympathetic influence to the kidney.

  • PDF

In vivo and in vitro Confirmation of Dose Homogeneity in Total Body Irradiation with Thermoluminescent Dosimeter (인체 및 인형 팬톰에서 전신방사선조사시 열형광선량계(TLD)를 이용한 선량분포 균일성 확인)

  • Chie Eui Kyu;Park Suk Won;Kang Wee-Saing;Kim Il Han
    • Radiation Oncology Journal
    • /
    • v.17 no.4
    • /
    • pp.321-328
    • /
    • 1999
  • Purpose : Total body irradiation (TBI) or whole body irradiation is used to acquire immune suppression, to treat malignant lymphoma and leukemia, and as an conditioning regimen for bone marrow transplantation. For these purposes, many methods were developed to obtain homogenous dose distribution. The objective of this study was to analyze and confirm the accuracy and the homogeneity of the treatment setup, the parallel opposed lateral technique, currently used in Seoul National University Hospital. Materials and Metheods : Surface dose data, measured with a thermoluminescent dosimeter, of 8 patients among 10 patients, who were given total body irradiation with the parallel opposed lateral technique between September 1996 to August 1998, at Seoul National University Hospital were analyzed. Surface doses were measured at the head, neck, axilla, thigh, and ankle level. Surface and midline doses were measured with similar set-up and technique in the Humanoid phantom. Results : Measured surface doses relative to prescribed dose for the head, neck, axilla, thight, and ankle leve were $91.3{\pm}7.8,{\;}98.3{\pm}7.5,{\;}95.1{\pm}6.3,{\;}98.3{\pm}5.5$, and $95.3{\pm} 6.3\%$, respectively. The midline doses of the head, neck, axilla, thigh, and ankle level estimated from the surface-to-midline ratios in the Humanoid Phantom were $103.4{\pm}9.0,{\;}107.8{\pm}10.5,{\;}91.1{\pm}6.1,{\pm} 93.8{\pm}4.5,{\;}and{\;}104.5{\pm}9.3\%$, respectively. Measured surface doses and estimated midline doses ranged from $-8.9\%$ to $+7.8\%$. Midline doses at the neck and the axilia level deviated more than $5\%$ from the prescribed doses. The difference of the estimated midline doses at the neck and the axilla level and the actual doses were attributed to the thickness differences between the Humanoid phantom and the patients. Conclusion Distribution of the midline doses as well as the suface doses were measured to be within $-8.7\~{\pm}7.8\%$ range. Actual dose distribution in the patient is expected to be better than the measured dose range mainly attributed to thickness difference between the patient and the Humanoid phantom.

  • PDF

A Study on the Usefulness of Copper Filter in Single X-ray Whole Spine Lateral using 3D Printer (단일조사 whole spine Lateral 검사에서 3D 프린터로 제작한 구리 필터 유용성 연구)

  • Kwon, Kyung-Tae;Yoon, Dayeon;Shin, Rae-Un;Han, Bong-Ju;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.899-906
    • /
    • 2020
  • The WSS lateral examination is important for diagnosing spinal disorders. Recently, long-length detectors for large-area diagnose have been popularized to effectively reduce the exposure dose and examination time. It can be applied very efficiently to examinations of patients with high risk of falls, children, and adolescents. However, since the image is acquired through a single irradiation, the volume of cervical vertebra is relatively smaller than the lumbar due to the geometrical anatomy of the spine. Therefore, this study intends to fabricate an additional filter using 3D printing technology and copper filament to obtain uniform image quality in the WSS lateral examination and to analyze the results. 3D printing technology is able to easily print a desired shape, so it is widely used in the entire industrial field, and recently, a copper filament has been developed to confirm the possibility as an additional filter. In the WSS lateral examination, CNR and SNR were excellently measured when the additional filter was applied, confirming the possibility of using the additional filter.

Design and Application of Acrylic Electron Wedge for Improving Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 acrylic electron wedge의 제작 및 사용)

  • Kim, Young-Bum;Kwon, Young-Ho;Whang, Woong-Ku;Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.36-42
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20%$) at the region of junction of fields. In this study, we made Acrylic Electron Wedges to improve dose inhomogeneities(${\pm}5%$) in these junction areas and to apply it to clinical practices. All measurements were made using 6, 9, 12, 16, 20 MeV Electron beams from a linear accelerator for a $10{\times}10\;cm$ field at 100cm of SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm acquires central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance according to the acryl insert, e.g. a 1 mm thick acryl insert reduces the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced to approximately 0.2 MeV. These effects were almost Independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase(less than 3%) in the surface dose and a small increase(less than 1%) in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction at the point of penumbra width($35\;mm{\sim}40\;mm$). We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be used to improve dose uniformity at electron field junctions and it will be effectively applied to clinical practices.

  • PDF

'THE METHOD OF TBI FOR ACCURATE REPRODUCTION OF RADIATION FIELD AND PATIENT POSITION' (방사선 전신 조사 치료시 정확한 환자자세 및 조사야 재현을 위한 방법)

  • KWEON YOUNG-HO;LEE BYOUNG-GOO;WHANG WOONG-KU;KIM YOU-HYUN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.156-166
    • /
    • 1995
  • Total body irradiation (TBI) requires large radiation field and extended source to axis distance (SAD), therefore in needs large size treatment room and it needs compensators which components. Appropriate thickness beam spoiler should be used to raise skin dose. Treatment machine, photon energy, total dose, dose rate, dose fractionation, patient position, shield of normal tissues and organs were known to important parameters for TBI. TBI disturbes regular daily treatment schedule and significantly overloads Radiation on oncology departments and during the treatment session it requires accurate reproduction of radiation field and patient position. We were enable to TBI in small size treatment room and short SAD with parallel opposing lateral fields technique and achieved homogenious whole body dose distribution using pb compensators and controled lung dose by lung shield blocks. Drawing a patient shadow on the wall, we could shortened set up time and possible to accurate reproduction of radiation field and patient position.

  • PDF