• 제목/요약/키워드: laser stimulation

검색결과 97건 처리시간 0.026초

The Effects of Transcutaneous Electrical Nerve Stimulation and Ultrasound Treatment Combined with High Intensity Laser Treatment on Pain, Grip Strength, and Hand Function in Patients with Carpal Tunnel Syndrome

  • Jawon Kim;Myunggi Cho;Yijung Chung
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권2호
    • /
    • pp.231-239
    • /
    • 2024
  • Objective: This study was conducted to investigate the effect of high-intensity laser therapy(HILT), transcutaneous electrical nerve stimulation(TENS), and ultrasound(US) treatment on pain, grip strength, and hand function in patients who had undergone carpal tunnel syndrome surgery. Design: A randomized controlled trial. Methods: Thirty patients who had undergone carpal tunnel syndrome surgery were randomly assigned to receive either TENS combined with HILT, US combined with HILT, or only HILT as the control group. Treatments were applied around the surgical site, and pre- and post-treatment changes were evaluated. Pain was assessed using NPRS, hand symptoms using CTS-6 and BCTQ-SSS, grip strength with an electronic dynamometer, and hand function using BCTQ-FSS. Treatments were administered seven times over two weeks. Results: The pain and symptoms were significantly reduced(p<0.05) and grip strength and hand function were significantly increased(p<0.05) after treatment compared to before treatment for all subjects. Pain was significantly reduced(p<0.05) and grip strength was significantly increased(p<0.05) in the TESN+HILT group and US+HILT group compared to the Control group. Hand symptoms were significantly reduced(p<0.05) and hand function significantly increased(p<0.05) in the TENS+HILT group compared to the Control group. Conclusions: TENS combined with HILT was found to be more effective than US combined with HILT in reducing pain and symptoms and improving grip strength and hand function in patients following carpal tunnel syndrome surgery. These findings suggest that these treatment modalities can be beneficially applied in clinical practice.

InGaAlP 레이저다이오드를 적용한 Rat의 착상 치유에서 면역조직화학적 연구 (A Study on the Immunohistology in Injury Cure of Rat by using InGaAlP Laser Diode)

  • 유성미;박용필;천민우
    • 한국전기전자재료학회논문지
    • /
    • 제22권5호
    • /
    • pp.431-435
    • /
    • 2009
  • The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a InGaAlP laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. The study has executed in-vivo experiment by employing our own developed laser diode irradiation system to investigate the effects of the InGaAlP laser diode irradiation on the wound healing as a preliminary study aimed at the application of InGaAlP laser diode to wound healing of human skin injury. The study cut out whole skin layers of Sprague-Dawley rat on the back part in 1 cm circle and observed developing effects after executing light irradiation for 9 days, and in result it is found that the light irradiation rat showed earlier wound healing than non-irradiation rat during the experimental period. In addition, there are some differences found regarding the healing process between laser diode irradiated rats and non-irradiated ones.

Expression of Nociceptin within Dura Mater in Response to Electrical Trigeminal Ganglion Stimulation in Rats

  • Kim, Jeong-Hee;Lee, Won-Suk
    • 대한의생명과학회지
    • /
    • 제11권3호
    • /
    • pp.375-382
    • /
    • 2005
  • This study aimed to investigate whether nociceptin is implicated in the, trigeminovascular responses to electrical stimulation of trigeminal ganglion in rats. An open cranial window was prepared on the right parietal bone of male Sprague-Dawley rats. Trigeminovascular system was stimulated by electrical stimulation of trigeminal ganglion (ETS; 5ms, 5Hz, 3V). Neonatal capsaicin treatment was performed with subcutaneous administration of capsaicin (50mg/kg) within the first 24 hours after birth. Changes in regional cerebral blood flow were continuously measured through the cranial window by laser-Doppler flowmetry, and the expression of nociceptin-like immunoreactivity was determined by immunohistochemistry. ETS caused increases in regional blood flow of pial arteriole in a voltage-dependent manner. ETS markedly and voltage-dependently increased the expression of nociceptin-like immunoreactivity in dura mater ipsilateral rather than contralateral to ETS. The nociceptin-like immunoreactivity was markedly reduced by pretreatments with calcitonin gene-related peptide(8-37) ($CGRP_{8-37},\;a\;CGRP_1$ receptor antagonist), L-733060 (a $NK_1$ receptor antagonist), and $[Nphe^1]$ nociceptin(1-13)$NH_2$ (a selective and competitive nociceptin receptor antagonist) as well as by neonatal capsaicin treatment. These results suggest that the electrical stimulation of trigeminal ganglion causes prominent expression of nociceptin within dura mater, in which not only neuropeptides inducing substance P and CGRP but also nociceptin are implicated in the trigeminovascular responses to electrical trigeminal ganglion stimulation.

  • PDF

파장별 레이저 자극과 전침 결합 시술이 신경병리성 동통에 미치는 영향 (Combined Effects of Different Wavelength Laser Stimulations and Electroacupuncture on Neuropathic Pain)

  • 조명래;김명훈;문영민;정성호;나창수
    • Korean Journal of Acupuncture
    • /
    • 제38권3호
    • /
    • pp.151-161
    • /
    • 2021
  • Objectives : The effects of a combined stimulation of 658 nm, 830 nm, 904 nm, and 1064 nm laser acupuncture treatment (LAT) and electroacupuncture treatment (EAT) on GB39 and GB34 on neuropathic pain in rats induced by tibial and sural nerve transection were studied in this paper. Methods : To express a neuropathic pain model, surgery was performed to transection rats' tibial and sural nerves. The rats were divided into normal group, control group, and experimental groups. In addition, the experimental groups were divided into 658 nm laser and electroacupuncture (LAT658+EAT), 830 nm laser and electroacupuncture (LAT830+EAT), 904 nm laser and electroacupuncture (LAT904+EAT), and 1064 nm laser and electroacupuncture (LAT830+EAT). For the treatment of the experimental groups, electroacupuncture and different laser wavelengths were alternately applied to GB34 and GB39 twice a week for 3 weeks for 1 minute 30 seconds. The withdrawal response of neuropathic rats' legs by acetone stimulation was observed, as well as the c-Fos in the central gray region in the midbrain of neuropathic rats together with Bax, Bcl2, and mGluR5 expressions associated with apoptosis. Results : Compared with the control group, a significant decrease in the frequency of paw withdrawal in response to acetone allodynia was observed in LAT658+EAT and LAT830+EAT groups in 6th times, LAT904+EAT group in 2nd, 3rd, and 6th times, and LAT1064+EAT group in 2nd and 6th times, respectively. For c-fos positive cells in the central gray region, a significant decrease was observed in LAT830+EAT, LAT904+EAT, and LAT1064+EAT groups in comparison with the control group. In Bax expression, LAT1064+EAT group showed a significant decrease compared to the control group. In Bcl-2 expression, the LAT658+EAT,the LAT904+EAT, and the LAT1064+EAT groups increased significantly compared to the control group. LAT830+EAT, LAT904+EAT, and LAT1064+EAT groups showed significantly increased mGlu5 expression compared to the control group. Conclusions : The combination of laser for each wavelength and electroacupuncture alternately performed in this study is thought to be effective in improving neuropathic pain and apoptosis.

655nm 레이저 다이오드 조사에 따른 생물학적 특성 평가 (The biomedical effect of 655nm Laser Diode irradiation)

  • 천민우;김성환;박용필;이호식;김태곤;박노봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.397-398
    • /
    • 2008
  • This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the 655nm laser diode and microprocessor unit. The apparatus used a 655 nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. And then, each experiment was performed to irradiation group and non-irradiation group for cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590nm transmittance of ELISA reader. As a result, the cell increase of cells was verified in irradiation group as compared to non-irradiation group.

  • PDF

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).

Comparison of the effects of transcutaneous electrical nerve stimulation, low level laser, and placebo treatment on temporomandibular joint disorders: a single-blind randomized controlled trial

  • Kim, Hyunjoong
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권4호
    • /
    • pp.244-251
    • /
    • 2020
  • Objective: Physical therapy techniques are required for patients with temporomandibular joint disorder (TMD), but the effects of treatment have not been compared. Therefore, effects of transcutaneous electrical nerve stimulation (TENS) and low level laser (LLL), which are most commonly used interventions, were compared. Design: Randomized controlled trial. Methods: Thirty-six participants with pain in the temporomandibular joint were enrolled, and 12 participants were randomly assigned to either the TENS group, LLL group, or placebo group. Each intervention was performed for a total of 6 sessions for 2 weeks. For the evaluation of the participants, the mouth opening (MO), pressure pain threshold (PPT), and stress were measured at three time periods: baseline, post-test, and follow-up at 2 weeks. Results: Significant interaction between groups according to each evaluation point was found only in PPT-masseter (p<0.05). The evaluation time point at which a significant difference appeared was at the post-test and follow-up at 2 weeks time periods. As a result of the post-test, the LLL group showed a significant improvement compared to the TENS group (p<0.05), and at 2 weeks follow-up, the TENS group showed a significant improvement compared to the placebo group (p<0.05). Conclusions: In this study, an experiment was conducted to compare the treatment effects when TENS, LLL, and placebo were given to patients with TMD. In addition, by quantitatively presenting the effect size of each treatment, this study suggests clinical use of TENS and LLL treatment for TMD.

Alterations in Meningeal Blood Flow by Stimulation of Trigeminovascular System in Rats

  • Kim, Byung-Soo;Choi, Chang-Hwa;Lee, Won-Suk
    • 대한의생명과학회지
    • /
    • 제11권3호
    • /
    • pp.365-373
    • /
    • 2005
  • The aim of this study was to investigate the alterations in meningeal blood flow by stimulation of trigeminovascular system. An open cranial window was prepared on the right parietal bone of male Sprague-Dawley rats. Trigeminovascular system was stimulated by electrical stimulation of trigeminal ganglion (ETS), somatosensory (whisker) stimulation, or topical applications of capsaicin and neuropeptides including substance P and calcitonin gene-related peptide (CGRP). Neonatal capsaicin pretreatment was performed with subcutaneous administration of capsaicin (50 mg/kg) within the first 24 hours after birth. Changes in regional blood flow of dural artery (rDBF) and pial artery (rPBF) were continuously measured through the cranial window by laser-Doppler flowmetry. Both ETS and capsaicin caused a chain of alterations in rPBF and rDBF responses, i.e., an immediate transient decrease followed by rapid and marked increase in rPBF, which were significantly attenuated not only by pretreatments with L-733,060, a $NK_1$ receptor blocker, $CGRP_{8-37}$, a $CGRP_1$ receptor blocker, and 7-nitroindazole monosodium salt (7-NINA), a neuronal nitric oxide synthase inhibitor but also by neonatal capsaicin treatment. Exogenous neuropeptides including substance P and CGRP increased the meningeal blood flow, which was significantly attenuated not only by pretreatment with L-733,060 and $CGRP_{8-37}$, respectively, but also by pretreatment with 7-NINA. The rPBF response to whisker stimulation was significantly attenuated not only by trigeminovascular system injuries including nasociliary nerve denervation and neonatal capsaicin treatment but also by pretreatments with L-733,060, $CGRP_{8-37}$ and 7-NINA. These results suggest that the stimulation of trigeminovascular system causes prominent alterations in meningeal blood flow, and that neuropeptides as well as nitric oxide in the trigeminovascular system are importantly implicated in the regulation of meningeal blood flow.

  • PDF

A Comparison with Laser Needle, Conventional TENS, and Acupuncture-like TENS upon Pain and Blood Flow in Healthy People

  • Junhyuck Park;Junke Pan;Hongje Jang;Jongeun Yim
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권2호
    • /
    • pp.185-191
    • /
    • 2023
  • Objective: Transcutaneous electrical nerve stimulation (TENS) is a treatment method for pain, and it can be divided into conventional TENS (C-TENS) and acupuncture-like TENS (A-TENS). More recently, high power lasers have increasingly been used to reduce pain caused by arthritis, residual neuralgia, and musculoskeletal disorders. The aim of this study was to compare the laser needle with C-TENS and A-TENS in terms of pain and blood flow in healthy people, as well as to confirm that the laser needle can replace TENS to treat pain. Design: A randomized controlled trial. Methods: The selected participants were divided using Minimize computer software into a laser group (n=13), a C-TENS group (n=13), and an A-TENS group (n=14); they underwent a pre-test for blood flow and pain in their forearm. The three groups received their respective interventions; they then underwent a second pain and blood flow test on the same spot. Results: No significant differences were observed in the A-TENS group between the pre- and post-tests, and a comparison among the three groups revealed no significant differences between the laser needle group and the C-TENS group in terms of pain. Regarding blood flow, no significant differences were found between the pre- and post-tests in the laser needle group; a comparison among the three groups only revealed a significant between the laser needle and A-TENS groups. Conclusions: This study confirmed that the laser needle can be used to treat pain when it is necessary to control blood flow.

Calcitonin Gene Related Peptide에 의한 치수미세순환 조절 (REGULATION OF PULPAL MICROCIRCULATION BY CALCITONIN GENE-RELATED PEPTIDE)

  • 김성교;김영경;진명욱
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.470-476
    • /
    • 2005
  • 본 연구에서는 감각성 neuropeptide인 CCRP의 치수혈류 조절에 관해 교감신경과의 유기적 관계를 연구함으로써 CGRP의 치수혈류 조절기전을 밝히고자 하였다. 열두 마리의 전신마취된 고양이에서 실험하였으며 CGRP를 혈관을 통해 전신적 또는 국소적으로 투여하였다. 견치에서 치수혈류의 변화를 측정하고 paired t-test로 통계분석 하였으며 $95\%$ 수준에서 유의성을 검증하였다. CGRP $(0.31{\mu}g/kg)$를 전신정맥으로 주사시, 전신혈압에 현저한 영향을 나타내면서 치수혈류는 평균 $68.85\%$의 일차적인 증가와 감소를 보였고 이차적으로 다시 평균 $161.8\%$ 증가하였다가 감소하였다. CCRP를 저용량 $(0.03{\mu}g/kg)$으로 국소적으로 투여시, 치수혈류는 평균 $2.92\%$의 미약한 증가를 나타내었다. 교감신경을 전기자극시 (10Hz, 4V, 1.5ms), 전신혈압은 영향을 받지 않으면서 치수혈류가 유의하게 평균 $57.88\%$ 감소하였다. 교감신경 자극으로 치수혈류가 저하되어 있는 동안 주입한 CCRP는 저하된 치수혈류를 유의하게 회복시켰다. CGRP의 이 치수혈류 증가 효과는 $CGRP_{8-37}$에 의해 효과적으로 차단되었다.