• Title/Summary/Keyword: laser device

Search Result 824, Processing Time 0.029 seconds

A Study on the Development of the Position Detection System of Small Vessels for Collision Avoidance (충돌 회피를 위한 소형 선박의 위치 검출 시스템 개발에 관한 연구)

  • Le, Dang-Khanh;Nam, Teak-Kun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.2
    • /
    • pp.202-209
    • /
    • 2014
  • In this paper, a developed device for detecting target's location and avoiding collision is proposed. Velocity and acceleration model of target are derived to estimate target's information, i.e. position, velocity and acceleration considering process and measurement noise. Kalman filtering method applied to the estimation process and its results was confirmed by simulation. The distance measurements system using laser sensor for moving target system is also developed to confirm the effectiveness of the proposed scheme. Experiments to get information of moving target with velocity and acceleration model was executed. The data with filtering and without filtering was compared by experiments. Discontinuous measured data was changed to smooth and continuous data by Kalman filtering. It is confirmed that desired data was obtained by applying proposed scheme. UI for measuring and monitoring the target data is developed and visual and auditory alarm function is attached on the system Finally, position estimation system of moving target with good performance is achieved by low price equipments.

A Study on the Analysis of Multi-beam Energy for High Resolution with Maskless Lithography System Using DMD (DMD를 이용한 마스크리스 리소그래피 시스템의 고해상도 구현을 위한 다중 빔 에너지 분석에 관한 연구)

  • Kim, Jong-Su;Shin, Bong-Cheol;Cho, Yong-Kyu;Cho, Myeong-Woo;Lee, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.829-834
    • /
    • 2011
  • Exposure process is the most important technology to fabricate highly integrated circuit. Up to now, mask type lithography process has been generally used. However, it is not efficient for small quantity and/or frequently changing products. Therefore, maskless lithography technology is raised in exposure process. In this study, relations between multi-beam energy and overlay were analyzed. Exposure experiment of generating pattern was performed. It was from presented scan line by multi- beam simulation. As a result, optimal scan line distance was proposed by simulation, and micro pattern accuracy could be improved by exposure experiment using laser direct imaging system.

A Research About P-type Polycrystalline Silicon Thin Film Transistors of Low Temperature with Metal Gate Electrode and High Temperature with Gate Poly Silicon (실리콘 게이트전극을 갖는 고온소자와 금속 게이트전극을 갖는 P형 저온 다결정 실리콘 박막 트랜지스터의 전기특성 비교 연구)

  • Lee, Jin-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.6
    • /
    • pp.433-439
    • /
    • 2011
  • Poly Si TFTs (poly silicon thin film transistors) with p channel those are annealed HT (high temperature) with gate poly crystalline silicon and LT (low temperature) with metal gate electrode were fabricated on quartz substrate using the analyzed data and compared according to the activated grade silicon thin films and the size of device channel. The electrical characteristics of HT poly-Si TFTs increased those are the on current, electron mobility and decrease threshold voltage by the quality of particles of active thin films annealed at high temperature. But the on/off current ratio reduced by increase of the off current depend on the hot carrier applied to high gate voltage. Even though the size of the particles annealed at low temperature are bigger than HT poly-Si TFTs due to defect in the activated grade poly crystal silicon and the grain boundary, the characteristics of LT poly-Si TFTs were investigated deterioration phenomena those are decrease the electric off current, electron mobility and increase threshold voltage. The results of transconductance show that slope depend on the quality of particles and the amplitude depend on the size of the active silicon particles.

Growth and characterization of molecular beam epitaxy grown GaN thin films using single source precursor with ammonia

  • Chandrasekar, P.V.;Lim, Hyun-Chul;Chang, Dong-Mi;Ahn, Se-Yong;Kim, Chang-Gyoun;Kim, Do-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.174-174
    • /
    • 2010
  • Gallium Nitride(GaN) attracts great attention due to their wide band gap energy (3.4eV), high thermal stability to the solid state lighting devices like LED, Laser diode, UV photo detector, spintronic devices, solar cells, sensors etc. Recently, researchers are interested in synthesis of polycrystalline and amorphous GaN which has also attracted towards optoelectronic device applications significantly. One of the alternatives to deposit GaN at low temperature is to use Single Source Molecular Percursor (SSP) which provides preformed Ga-N bonding. Moreover, our group succeeds in hybridization of SSP synthesized GaN with Single wall carbon nanotube which could be applicable in field emitting devices, hybrid LEDs and sensors. In this work, the GaN thin films were deposited on c-axis oriented sapphire substrate by MBE (Molecular Beam Epitaxy) using novel single source precursor of dimethyl gallium azido-tert-butylamine($Me_2Ga(N_3)NH_2C(CH_3)_3$) with additional source of ammonia. The surface morphology, structural and optical properties of GaN thin films were analyzed for the deposition in the temperature range of $600^{\circ}C$ to $750^{\circ}C$. Electrical properties of deposited thin films were carried out by four point probe technique and home made Hall effect measurement. The effect of ammonia on the crystallinity, microstructure and optical properties of as-deposited thin films are discussed briefly. The crystalline quality of GaN thin film was improved with substrate temperature as indicated by XRD rocking curve measurement. Photoluminescence measurement shows broad emission around 350nm-650nm which could be related to impurities or defects.

  • PDF

Influence of the Fluorine-doping Concentration on Nanocrystalline ZnO Thin Films Deposited by Sol-gel Process

  • Yoon, Hyunsik;Kim, Ikhyun;Kang, Daeho;Kim, Soaram;Kim, Jin Soo;Son, Jeong-Sik;Leem, Jae-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.204.2-204.2
    • /
    • 2013
  • Wide band gap II-VI semiconductors have attracted the interest of many research groups during the past few years due to the possibility of their applications in light-emitting diodes and laser diodes. Among the II-VI semiconductors, ZnO is an important optoelectronic device material for use in the violet and blue regions because of its wide direct band gap (Eg ~3.37 eV) and large exciton binding energy (60 meV). F-doped ZnO (FZO) and undoped ZnO thin films were grown onto quartz substrate by the sol-gel spin-coating method. The doping level in the solution, designated by F/Zn atomic ratio of was varied from 0 to 5 in 1 steps. To investigate the effects of the structure and optical properties of FZO thin films were investigated using X-ray diffraction (XRD), UV-visible spectroscopy, and photoluminescence (PL). In the XRD, the residual stress, FWHM, bond length, and average grain size were changed with increasing the doping concentration. For the PL spectra, the high INBE/IDLE ratio of the FZO thin films doping concentration at 1 at.% than the other samples.

  • PDF

Dental Hygienist's Job Perception of Some Prospective Graduates (일부 치위생학과 졸업예정자의 치과위생사 직무에 대한 인식)

  • Hwang, Soo-Jeong;Bae, Soo-Myoung;Yu, Ji-Su;Han, Yang-Keum
    • Journal of Korean Dental Hygiene Science
    • /
    • v.3 no.1
    • /
    • pp.25-36
    • /
    • 2020
  • Introduction: The legal duties of Korean dental hygienists are different from the actual tasks. These factors cause dental hygienists to experience work stress. Therefore, it is necessary to investigate what tasks the dental hygienist expects to perform. Methods: This study examined the perception of dental hygienists' work on 158 prospective graduates of the 3rd-year and 4th-year course of dental hygiene. The questionnaire about the dental hygienist's duties was prepared based on the job description of dental hygienists by the Korea Health Personnel Licensing Examination Institute. Results: More than 84% said that all of the work in the second job description was possible as dental hygienists. subjects responded that the following items were not dental hygienists' duties: treatment plan based on medical history and dental history, treatment plan based on an intraoral and extraoral examination, treatment plan based on the results of teeth and periodontal examination, analysis of oral health data in community, planning of oral health promotion in community, planing of water fluoridation, reading of radiography, root planing, physical treatment on head and neck, using an ultrasonic device on head and neck, dealing with laser devices, making a temporary crown, suture and stitch-out, and intramuscular injection. Conclusions: Most graduates of dental hygiene departments have recognized that the tasks described in the second job description are dental hygienists' work; therefore, it is necessary to improve the gap between expected work and legal work.

Development of Smart Tote Bags with Marquage Techniques Using Optical Fiber and LEDs (광섬유와 LED를 활용한 마카쥬(marquage) 기법의 스마트 토트백 개발)

  • Park, Jinhee;Kim, Sang Jin;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.25 no.1
    • /
    • pp.51-64
    • /
    • 2021
  • The purpose of this study was to develop smart bags that combining fashion-specific trends and smart information technologies such as light-emitting diodes(LED) and optic fibers by grafting marquage techniques that have recently become popular as part of eco-fashion. We applied e-textiles by designing leather tote bags that could show off LED luminescence. A total of two tote bags, a white-colored peacock design and a black-colored paisley design, divided the LED's light-emitting method into two types, incremental lighting and random light-emission to suit each design, and the locations of the optical fibers were also reversed depending upon the design. The production of circuits for the LEDs and optical fibers was based on the design, and a flexible conductive fabric was laser-cut instead of wire line and attached to the circuit-line location. A separate connector was underwent three-dimensional(3D)-modeling and was connected to high-luminosity LEDs and optic fiber bundles. The optical fiber logo part expressed a subtle image using a white-colored LED, which did not offset the LED's sharp luminous effects, suggesting that using LEDs with fiber optics allowed for the expression of each in harmony without being heterogeneous. Overall, the LEDs and fiber optic fabric were well-harmonized in the fashion bag using marquage techniques, and there was no sense of it being a mechanical device. Also, the circuit part was made of conductive fabric, which is an e-textile product that feels the same as a thin, flexible fabric. The study confirmed that the bag was developed as a smart wearable product that could be used in everyday life.

Effects of Magnetic Therapy to Improve on Pain Threshold, Blood Flow, and Balance in Patient with Knee Osteoarthritis (자기장 치료법이 무릎 뼈관절염 환자의 통증 역치, 혈류량 및 균형능력에 미치는 영향)

  • Kyong-Hun Kim;Dong-Hoon Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose : This study was performed to evaluate the effects of magnetic therapy (MT) on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Methods : A single-blind, randomized controlled trial (RCT) was conducted with 30 patient with knee osteoarthritis. They were randomly allocated 2 groups; magnetic therapy group (MTG; n=15) and placebo magnetic therapy group (PG; n=15). The MTG group received 30 minutes magnetic therapy and 20 minute conservative physical therapy (Hotpack, ICT), magnetic therapy was conducted in magnetic therapy device (OM-100, NUGA, Korea). In the placebo magnetic group received 30 minutes placebo magnetic therapy and 20 minute conservative physical therapy. Each group performed 50 minutes a day 3 times a week for 8 weeks. The primary outcome pressure pain threshold test, blood flow, balance ability were measured by a pressure threshold meter (Commander algometer, JTECH medical, USA), laser dofler image (Moor LDI2-IR, Moor instruments, USA), balance measurement system (BioRescue, Marseille, France). The measurement were performed before and after the 8 weeks intervention period. Results : Both groups demonstrated significant improvement of outcome in pain threshold, blood flow, and balance ability during intervention period. magnetic therapy group revealed significant differences in pain threshold, blood flow, and balance as compared to the placebo magnetic therapy group groups (p<.05). Our results showed that magnetic therapy was more effective than placebo therapy on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Conclusion : Our findings indicate that magnetic therapy can improve pain threshold, blood flow, and Balance, highlight the benefits of magnetic therapy. This study will be able to be used as an intervention data for recovering pain threshold, blood flow, and balance in patients with knee osteoarthritis.

DEVELOPMENT OF LIGHTWEIGHT OPTICAL TELESCOPE KIT USING ALUMINUM PROFILE AND ISOGRID STRUCTURE

  • Park, Woojin;Lee, Sunwoo;Han, Jimin;Ahn, Hojae;Ji, Tae-Geun;Kim, Changgon;Kim, Dohoon;Lee, Sumin;Kim, Young-Jae;Kim, Geon-Hee;Kim, Junghyun;Kim, Ilhoon;Pak, Soojong
    • Journal of The Korean Astronomical Society
    • /
    • v.55 no.1
    • /
    • pp.11-22
    • /
    • 2022
  • We introduce the Transformable Reflective Telescope (TRT) kit that applies an aluminum profile as a base plate for precise, stable, and lightweight optical system. It has been utilized for optical surface measurements, developing alignment and baffle systems, observing celestial objects, and various educational purposes through Research & Education projects. We upgraded the TRT kit using the aluminum profile and truss and isogrid structures for a high-end optical test device that can be used for prototyping of precision telescopes or satellite optical systems. Thanks to the substantial aluminum profile and lightweight design, mechanical deformation by self-weight is reduced to maximum 67.5 ㎛, which is an acceptable misalignment error compared to its tolerance limits. From the analysis results of non-linear vibration simulations, we have verified that the kit survives in harsh vibration environments. The primary mirror and secondary mirror modules are precisely aligned within 50 ㎛ positioning error using the high accuracy surface finished aluminum profile and optomechanical parts. The cross laser module helps to align the secondary mirror to fine-tune the optical system. The TRT kit with the precision aluminum mirror guarantees high quality optical performance of 5.53 ㎛ Full Width at Half Maximum (FWHM) at the field center.

Manufacturing and Characteristic Evaluation of Free space Optical Communication Devices in 5G Mobile Base Stations for Emergency Disaster Response (긴급재난 대응용 5G 이동 기지국을 위한 대기공간 광통신 장치의 제작과 특성평가)

  • Jin-Hyeon Chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.131-138
    • /
    • 2023
  • In this paper, a free space optical communication device that can be used in a mobile base station of several km or less was fabricated and its characteristics were investigated. To overcome the loss due to atmospheric transmission, an optical fiber amplifier (EDFA) with an output of 23 dBm or more was used. In order to increase the focusing speed and miniaturization of the laser beam, an optical lens was manufactured, and a transmission lens was designed to have beam divergence within the range of 1.5 to 1.8 [mrad]. A PT module that controls PAN/TILT was fabricated in order to reduce pointing errors and effective automatic alignment between transceiver devices. In this study, Reed-Solomon (RS) code was used to maintain the transmission quality above a certain level. It was manufactured to be able to communicate at a wireless distance of 300m in a weather situation with visibility of 300m. For performance measurement, it was measured using BERT and eye pattern analyzer, and it was confirmed that BER can be maintained at 2.5Gbps.