• 제목/요약/키워드: laser device

검색결과 824건 처리시간 0.032초

위험기계 방초장치에 적용되는 레이저에 관한 연구 (The Study on the Laser in the Safety Device for Dangerous Machine)

  • 이충렬;김창봉
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.22-29
    • /
    • 2002
  • The safety device of infrared type for dangerous machine being used currently has a harmful effect on human's eye and skin. In this paper we explain about the characteristics of lasr source and analyze the amount of harmfulness on human's eye by simulation method. We used the datas given by ANSI in this simulation.

InGaAs 양자점 레이저 다이오드와 양자우물 레이저 다이오드의 특성 비교 (Comparisons of lasing characteristics of InGaAs quantum-dot and quantum well laser diodes)

  • 정경욱;김광웅;유성필;조남기;박성준;송진동;최원준;이정일;양해석
    • 한국진공학회지
    • /
    • 제16권5호
    • /
    • pp.371-376
    • /
    • 2007
  • 분자선 에피택시(molecular beam epitaxy, MBE)로 성장된 InGaAs 양자점 레이저 다이오드(quantum dot laser diode, QD-LD)와 InGaAs 양자우물 레이저 다이오드(quantum well laser diode, QW-LD)의 특성을 비교하였다. 펄스 입력전류 하에서 문턱전류밀도(threshold current density, $J_{th}$), 특성온도(characteristic temperature, $T_0$), 온도에 따른 발진파장의 변화도($d{\lambda}/dT$)를 측정한 결과, 양자우물 레이저 다이오드는 $J_{th}\;=\;322\;A/cm^2,\;T_0\;=\;55.2\;K,\;d{\lambda}/dT\;=\;0.41\;nm/^{\circ}C$로 측정되었으며, 양자점 레이저 다이오드는 $J_{th}\;=\;116\;A/cm^2,\;T_0\;=\;81.8\;K,\;d{\lambda}/dT\;=\;0.33\;nm/^{\circ}C$로 측정되었다. 양자점 레이저 다이오드는 양자우물 레이저 다이오드와 비교하였을 때, 문턱전류밀도 및 발진 광 파워가 상대적으로 우수한 결과를 보여주었다.

Laser Diode Tester 개발과 비젼 피드백을 이용한 위치 보정 (Development of Laser Diode Tester and Position Compensation using Feedback with Machine Vision)

  • 김재희;유철우;박상민;유범상
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.30-36
    • /
    • 2004
  • The development of LD(Laser Diode) tester and its control system based on the graphical programming language(LabVIEW) is addressed. The ill tester is used to check the optic power and the optic spectrum of the LD Chip. The emitter size of LD chip and the diameter of the Detector(optic fiber and photo diode) are very small, therefore the test device needs high accuracy. But each motion part of the test device could not accomplish high accuracy due to the limit of the mechanical performance. So, an image processing with machine vision is proposed to compensate for the error. By adopting our method we can reduce the error of position within $\pm$5$\mu\textrm{m}$.

칼만 필터를 이용한 레이저 간섭계의 측정 정밀도 향상에 관한 연구 (A Study on the Improvement of Measurement Accuracy of Laser Interferometer using the Kalman filter)

  • 이재호;박태동;정준흥;박기헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1783-1784
    • /
    • 2006
  • A laser interferometer is the unique measurement device that can measure the range up to a few meters with sub-nano resolution and this characteristic makes it as the important sensing device for the emerging nano-mechatronics technologies. The laser interferometer, however, is very sensitive to the environments such as temperature, humidity, sound noises, vibrations and air turbulences and these factors result in a few hundred nano meter errors. There have been many efforts to reduce these environmental errors. The output of the laser interferometer is assumed to be the sum of a real displacement and a Markov process noise. The purpose of this paper is to develop Kalman filter algorithms to reduce the laser interferometer measurement errors by exploiting the information of displacements in position-servo systems.

  • PDF

레이저 우식진단기기 'DIAGNODent$^{(R)}$'의 활용 (Use of laser fluorescence device 'DIAGNODent$^{(R)}$' for detecting caries)

  • 이병진
    • 대한치과의사협회지
    • /
    • 제49권8호
    • /
    • pp.461-471
    • /
    • 2011
  • The detection of carious lesions is a key point to apply appropriate preventive measures or operative treatment of dental caries. A laser fluorescence device DIAGNOdent$^{(R)}$ (KaVo, Biberach, Germany) has also been shown to be of additional clinical value in the detection of initial caries. This report focus on the DIAGNOdent$^{(R)}$ for caries detection. DIAGNOdent$^{(R)}$ irradiate visible red light at a wavelength of 655 nm to elicit near-infrared fluorescence from caries lesion. This device is known as a reproducible method for caries detection, with good sensitivity and specificity especially for caries detection on occlusal and accessible smooth surfaces. DIAGNOdent$^{(R)}$ tended to be more sensitive method of detecting occlusal dentinal caries, however, showed more false-positive diagnoses than the visual inspection. So Clinician should not use the device as a clinician's primary diagnostic method and it is recommended that the device should be used in the decision-making process in relation to the diagnosis of caries as a second opinion in cases of doubt after visual inspection. The trend of modern dentistry would be a preventive approach rather than invasive treatment of the disease. This is possible only with early detection and respective preventive measures, DIAGNOdent$^{(R)}$ can help the changes.

일일 정도관리를 위한 Daily check device 의 제작 및 효율성 평가 (Daily check device manufacture and efficiency Evaluation for daily Q.A)

  • 김찬용;제영완;이제희;박흥득
    • 대한방사선치료학회:학술대회논문집
    • /
    • 대한방사선치료학회 2005년도 춘계학술대회 초록집
    • /
    • pp.19-22
    • /
    • 2005
  • 방사선 종양학과에서 실시하고 있는 일일 정도관리 항목인 out put laser alignment, field size, SSD indicator 점검을 간편하고 정확하게 할 수 있도록 phantom 모양의 daily check device를 설계하고 제작하였다. 본 장치를 사용하여 4개월(2005. $2\~5$)월 동안 4대의 선형가속기 일일 정도관리에 사용한 곁과 측정과정이 편리하고 시간이 단축되어 일일점검의 효율성이 향상 되었고, 출력선량 측정은 각 장비별로 ${\pm}\;2\%$ 이내였으며 laser, field size, SSD indicator 는 ${\pm}\;1mm$ 이내의 범위에서 측정되었다. 일일 정도관리 기록을 기초로 하여 월간, 연간 정도관리의 객관적인 기초 자료로 활용할 수 있었다. 제작된 daily check device는 기존 상품화된 고가의 측정 장비를 대체 사용가능하게 함으로써 비용절감 효과가 기대되며, 향후 장치 재질의 견고성 및 가벼운 소재의 개발이 필요할 것으로 사료된다.

  • PDF

미세 3차원 구조물 제조를 위한 디지털 마이크로미러소자 응용 마이크로 광조형 (Digital Micromirror Device Based Microstereolithography for the Fabrication of 3D Microstructures)

  • 주재영;김성훈;정성호
    • 한국레이저가공학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2006
  • In order to increase the productivity of conventional microstereolithography (MSL), digital micromirror device($DMD^{TM}$) based MSL is proposed and the feasibility of 3D rnicrocomponents fabrication is demonstrated in two ways; free surface and constrained surface techniques. The clearness of optical images at the exposure plane was confirmed for the fabrication of an accurate 3D structure by controlling the dynamic viscosity of FA1260T and the shape accuracy of a structure fabricated with epoxy-based resin ($Somos^{\circledR}$ 10120) was analyzed to determine the optimum curing conditions. After finding the appropriate process variables, the feasibility of multiple microstructures is then demonstrated. Due to the high productivity, MSL using $DMD^{TM}$ showed the potential to replace the existing focused laser beam MSL.

  • PDF

Development of Optical Device Housing Compacted Using SUS304L Granulated Powders

  • Suzuki, Hironori;Hara, Toshihiro;Ogino, Yukinobu;Sato, Yasushi;Tomota, Yo
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.754-755
    • /
    • 2006
  • In order to develop the SUS304L housing by powder metallurgy for an optical device useful for the FTTH communication system, the optimum compacting pressure and sintering temperature were investigated using granulated powder as the material to satisfy high air-tightness and high laser-weldability. Then the laser-welding test of specimen made under the optimum condition was carried out to observe welding sputters.

  • PDF

라인레이저를 이용한 3D 모델 추출 방법 (3D Extraction Method Using a Low Cost Line Laser)

  • 윤춘호;김태기;조용욱;남기원;임충혁
    • 한국생산제조학회지
    • /
    • 제26권1호
    • /
    • pp.108-113
    • /
    • 2017
  • In this paper, we proposed a three-dimensional(3D) scanning system based on laser vision technique for 3D model reconstruction. The proposed scanning system consists of line laser, camera, and turntable. We implemented the 3D scanning system using low quality elements. Although these are low quality elements, we reduced the 3D data reconstruction errors greatly using two methods. First, we developed a maximum brightness detection algorithm. This algorithm extracts the maximum brightness of the line laser to obtain the shape of the object. Second, we designed a new laser control device. This device helps to adjust the relative position of the turntable and line laser. These two methods greatly reduce the measuring noise. As a result, point cloud data can be obtained without complicated calculations.