• Title/Summary/Keyword: large-area particle measurement

Search Result 20, Processing Time 0.025 seconds

Simultaneous Measurement of Fluid Velocity and Particle Velocity in a Particle-Containing Fluid Flow (입자가 포함된 유동장에서 유체속도와 입자속도의 동시 측정기법)

  • Jin Dong-Xu;Lee Dae-Young;Lee Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2005
  • A novel method for simultaneously measuring the fluid velocity and the large particle velocity in a particle-containing fluid flow is developed in this study. In this method, the fluid velocity and the large particle velocity are measured by PIV and PTV, respectively. The PIV and PTV images are obtained from the same flow images. Since a PIV result represents the average displacement of all particles in an interrogation area, it will include an error caused by the relative displacement between the large particles and the fluid. In order to reduce the false influence of large particles on the PIV calculation, the mean brightness of small PIV particle images is substituted to the locations of large particles in the PIV images. The simulation results showed that the new method significantly reduces the PIV error caused by the large particles even at the case where the large particles occupy area fraction as large as $20\%$ of the full image.

A PTV Applied to Measuring the Solid Particle Velocity of Slurry Flow in a Vertical Pipe (PTV를 이용한 수직관 내 슬러리유동의 고체입자 속도계측 연구)

  • Yang, Chan-Kyu;Choi, Jong-Su;Hong, Sup
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.213-219
    • /
    • 2001
  • In this paper, particle velocity of slurry flow, a kind of solid-particle two phase flow, was measured by using a particle tracking velocimetry. Particles are modeled by sphere-shaped glass whose diameters are 3mm, 5mm, and 7mm At first, a particle which is falling in the water is captured and analyzed to give their free falling velocity. The falling velocity was very high up to about 4m/sec in the air, which needs special algorithm for the accurate measurement. For the upwelling slurry flow in the straight duct, there are some noises caused by cavity. However, the effect was so small that it does not affect the measurement of large particles. From the preliminary study of applying the PTV to measurement of particle movement in slurry flow, we could find out the optimum value of parameters: threshold value., searching area radius and correlation area size.

  • PDF

Real-time High Resolution PM Monitoring in Seoul (서울지역 미세먼지의 실시간 고해상도 모니터링 방안)

  • Kang, Doo Soo;Bong, Choon Keun;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.67-78
    • /
    • 2019
  • Since existing measurement sites are required to construct a high-cost PM measuring device and a measuring site of a large area, there is a limit to the construction of a high-resolution measurement network. Therefore, it is necessary to develop a low-cost, high-performance PM measuring device (as an alternative technology) that can increase the resolution of PM measurement, and it is necessary to establish a base to provide real-time PM information for whole people. Therefore, in this study, the alternative technique (light scattering method) for achieving the above object was examined, performance evaluation was carried out, and it was verified that the light scattering method was usable. Various PM measurement results were compared and analyzed to find PM monitoring points and resolutions we would like to propose.

Abdominal-Deformation Measurement for a Shape-Flexible Mannequin Using the 3D Digital Image Correlation

  • Liu, Huan;Hao, Kuangrong;Ding, Yongsheng
    • Journal of Computing Science and Engineering
    • /
    • v.11 no.3
    • /
    • pp.79-91
    • /
    • 2017
  • In this paper, the abdominal-deformation measurement scheme is conducted on a shape-flexible mannequin using the DIC technique in a stereo-vision system. Firstly, during the integer-pixel displacement search, a novel fractal dimension based on an adaptive-ellipse subset area is developed to track an integer pixel between the reference and deformed images. Secondly, at the subpixel registration, a new mutual-learning adaptive particle swarm optimization (MLADPSO) algorithm is employed to locate the subpixel precisely. Dynamic adjustments of the particle flight velocities that are according to the deformation extent of each interest point are utilized for enhancing the accuracy of the subpixel registration. A test is performed on the abdominal-deformation measurement of the shape-flexible mannequin. The experiment results indicate that under the guarantee of its measurement accuracy without the cause of any loss, the time-consumption of the proposed scheme is significantly more efficient than that of the conventional method, particularly in the case of a large number of interest points.

The Study of Pore Structure in Shale Gas Reservoir Using Large-area Particle Measurement Method (대면적 입자 측정 분석법을 이용한 셰일 가스 저류층 내공극 구조 연구)

  • Park, Sun Young;Ko, Yong-kyu;Choi, Jiyoung;Lee, Junhee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.4
    • /
    • pp.209-218
    • /
    • 2021
  • Studies of pore structure in shale gas reservoirs are essential to increase recovery rates, which is in the spotlight concerning unconventional resources. In this study, the distribution of pores in shale gas reservoir sample were observed using Scanning Electron Microscope Particle Analysis (SELPA), which is appropriate to analyze the distribution of particle or shape for sample in large area. A sample from the A-068 borehole drilled in the Liard Basin was analyzed; calcite is the main mineral. The pore size ranges from tens of nanometers to hundreds of micrometers and the contribution of each pore size to overall sample porosity was determined using SELPA. The distribution of pores was determined by observing the surface in the same area at magnifications of ×1000, ×3000 and ×5000. Pores less than 100 nm were observed at high magnifications and confirm that small-scale pore distribution can be analyzed and identified rapidly using SELPA. The method introduced in this study will be useful to understand pore structures in unconventional reservoirs.

Characteristics of particles at Kosan, Cheju Island: Intensive study results duting March 11 .sim. 17 1994 (제주도 고산지역 입자특성 : 1994년 3월 11일 - 17일 측정결과)

  • 김용표;심상규;문길주;백남준;김성주;허철구;강창희
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.263-272
    • /
    • 1995
  • Characteristics of anbient at Korean, Cheju Island have been studied during the intensive field study period on March 11 .sim. 17, 1994 in collaboration with other research organizations from Korea and abroad. The particle size distribution was measured using an Electrical Aerosol Analyzer(EAA) and an Optical particle Counter(OPC). Fine particles(PM1 and PM3) have been collected by filter pack samplers and their ionic compositions have been analyzed. sampling errors inherent to the filter pack sampling method are discussed and the method to analyze those errors are presented. The rine mass concentrations of this study show very similar mass concentrations when Seoul is clear. This is somewhat surprising result, because the most of researchers believe that Kosan is one of the cleanest area in Korea. Bimodal volume size distributions with peak values around 0.1 .sim. 0.2.mu.m and 3.mu.m in particle dimeter were observed for most of the measurement period, particle mass loadings and ionic composition data show a large fraction of particles are from non-sea salt origins. Estimation of water content and acidity of particles based on measurement by a gas/particle equilibrium model, SCAPE, reveals that the pH values of particles are comparable to or lower than those estimated based on measurements in Los Angeles, U.S.A. during the SCAQS study. These findings with the meteorological conditions during the study period suggest that the particles collected during the period have originated from outside Cheju Island.

  • PDF

Error Analysis of Image Velocimetry According to the Variation of the Interrogation Area (상관영역 크기 변화에 따른 영상유속계의 오차 분석)

  • Kim, Seojun;Yu, Kwonkyu;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.8
    • /
    • pp.821-831
    • /
    • 2013
  • Recently image velocimetries, including particle image velocimetry (PIV) and surface image velocimetry (SIV), are often used to measure flow velocities in laboratories and rivers. The most difficult point in using image velocimetries may be how to determine the sizes of the interrogation areas and the measurement uncertainties. Especially, it is a little hard for unskilled users to use these instruments, since any standardized measuring techniques or measurement uncertainties are not well evaluated. Sometimes the user's skill and understanding on the instruments may make a wide gap between velocity measurement results. The present study aims to evaluate image velocimetry's uncertainties due to the changes in the sizes of interrogation areas and searching areas with the error analyses. For the purpose, we generated 12 series of artificial images with known velocity fields and various numbers and sizes of particles. The analysis results showed that the accuracy of velocity measurements of the image velocimetry was significantly affected by the change of the size of interrogation area. Generally speaking, the error was reduced as the size of interrogation areas became small. For the same sizes of interrogation areas, the larger particle sizes and the larger number of particles resulted smaller errors. Especially, the errors of the image velocimetries were more affected by the number of particles rather than the sizes of them. As the sizes of interrogation areas were increased, the differences between the maximum and the minimum errors seemed to be reduced. For the size of the interrogation area whose average errors were less than 5%, the differences between the maximum and the minimum errors seemed a little large. For the case, in other words, the uncertainty of the velocity measurements of the image velocimetry was large. In the viewpoint of the particle density, the size of the interrogation area was small for large particle density cases. For the cases of large number of particle and small particle density, however, the minimum size of interrogation area became smaller.

A Research on the Vector Search Algorithm for the PIV Flow Analysis of image data with large dynamic range (입자의 이동거리가 큰 영상데이터의 PIV 유동 해석을 위한 속도벡터 추적 알고리즘의 연구)

  • Kim Sung Kyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.13-18
    • /
    • 1998
  • The practical use of the particle image velocimetry(PIV), a whole-field velocity measurement method, requires the use of fast, reliable, computer-based methods for tracking velocity vectors. The full search block matching, the most widely studied and applied technique both in area of PIV and Image Coding and Compression, is computationally costly. Many less expensive alternatives have been proposed mostly in the area of Image Coding and Compression. Among others, TSS, NTSS, HPM are introduced for the past PIV analysis, and found to be successful. But, these algorithms are based on small dynamic range, 7 pixels/frame in maximum displacement. To analyze the images with large displacement, Even and Odd field image separation and a simple version of multi-resolution hierarchical procedures are introduced in this paper. Comparison with other algorithms are summarized. A Results of application to the turbulent backward step flow shows the improvement of new algorithm.

  • PDF

A study on spatial distribution characteristics of air pollutants in Bucheon-si using mobile laboratory (이동측정차량을 활용한 부천시 대기오염의 공간 분포 특성 연구)

  • Kim, Jong Bum;Kim, Chang Hyeok;Noh, Sujin;Hwang, Eun Young;Park, Duckshin;Lee, Jeong Joo;Kim, Jeongho
    • Particle and aerosol research
    • /
    • v.17 no.1
    • /
    • pp.9-20
    • /
    • 2021
  • As a large city advanced, the urban environment is becoming an issue. The contribution of vehicle emissions in air pollutants was very high according to the clean air policy support system (CAPSS). In order to improve the air quality in large cities, it is necessary to establish improvement measures by sources, analyzing the air quality of roadside. We divided Bucheon city into 4 regions to investigate the roadside pollutants of each district using the mobile laboratory (ML) and air quality monitoring station (AQMS). ML was used to measure pollutants emitted from vehicles and AQMS data was used as a comparison group of ML data. As a measurement result of pollutants in the roadside, the concentration of air pollutants in industrial & engineering complex area was the highest and concentration of air pollutants in residential & forest complex area was lower. By street, Bucheon-ro, Sinheung-ro, Sosa-ro, and Gyeongin-ro were identified as high concentrations. Therefore, further researches on preparing management measures for roads in the hot-spot area are needed.

An Investigation of Lattice Boltzmann Multi-phase Model and it Application (래티스볼츠만 다상류 모델의 검토 및 응용)

  • Kang, Ho-Keun;Ahn, Soo-Whan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.269-270
    • /
    • 2006
  • A finite difference lattice Boltzmann model which allows us to simulate gas-liquid two-phase flows with large density difference, for instance, 800 times for air and water is considered. Two-particle model is used and the density difference is introduced by changing the acceleration according to the fluid density. Numerical measurement of surface tension agrees well with theoretical predictions. Simulations of two-phase phenomenon for phase-transition is carried out, showing applicability of the model for two-phase flows. The two-dimensional cavitating flow around a board set up in the fluid way is also simulated. As a result, it was confirmed that the FDLB method with two-particle model was effective in numerical simulation of cavitating flow and the bubble periodically grew up at the low pressure area behind the board, in which the fluid condition was influenced by the cavitation number.

  • PDF