• Title/Summary/Keyword: large volume apparatus

Search Result 26, Processing Time 0.024 seconds

Laminar Flame Speed Model of Fuel Blends at Elevated Temperatures and Pressures (고온 고압에서 혼합연료의 층류화염속도 예측 모델에 대한 연구)

  • Byun, Jung Joo
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.2
    • /
    • pp.9-16
    • /
    • 2012
  • Iso-octane, n-heptane and their blends were tested in a constant volume combustion chamber to measure laminar flame speeds. The experimental apparatus was automatically controlled to enhance the accuracy and data acquisition speed. A large database of laminar flame speeds at elevated temperatures and pressures was established. From this database, laminar flame speeds of iso-octane, n-heptane and their blends were investigated and analysed to derive new correlation to predict laminar flame speeds at any blending ratio. The new flame speed model was successfully applied to these fuels with limited range of errors.

High pressure X-ray diffraction study on a graphite using Synchrotron Radiation (고압하에서 방사광을 이용한 흑연에 대한 연구)

  • Kim, Young-Ho;Na, Ki-Chang
    • The Journal of the Petrological Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.34-40
    • /
    • 1994
  • High pressure X-ray diffraction study was carried out on a graphite to investigate its compressibility as well as any possible phase transition to the hexagonal diamond structure at room temperature. Energy dispersive X-ray diffraction method was introduced using a Mao-Bell type diamond anvil cell with Synchrotron Radiation. Polycrystalline sodium chloride was compressed together with graphite for the high pressure determinations. Because of the poor resolution of the X-ray diffraction pattern of graphite, its compressibility was estimated to be almost same as that of NaCl by graphite (002) X-ray diffraction peak only. An observation of any new peak from a possible hexagonal diamond phase seems very unplausible for its definite identification based on the present data. Alternative approaches such as an Wiggler Radiation source as well as a Large Volume high pressure apparatus will be necessary for the detailed studies on a graphite in future.

  • PDF

An Experimental Study on the Quality Estimation of the High-Quality of Recycled Sand by the differences between Small. Large Sand Flux Apparatus (샌드플럭스 장치의 대 . 소용량 차이에 따른 고품질 순환모래의 품질특성에 관한 연구)

  • Lee, Yun-Sung;Lee, Ji-Hwan;Bae, Kee-Sung;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.81-85
    • /
    • 2009
  • This study was to execute the basic property evaluation of recycled sand which produced by the sand flux device in order to evaluate the performance of differences between small large sand flux device. As a result, this study has found out that the recycled sand after passing the sand flux device had excellent quality characteristics compared with the One before passing the device. In additional experiment On the basic material properties, this study showed a tendency to improve the quality and performance significantly in case of fineness modulus, absolute surface dried density, 0.08mm sieve throughput, volume of clay lumps, and content of organic foreign matter. In conclusion, it was considered as various quality performances of recycled sand were improved through the production stage of prototype.

  • PDF

The Effect of Geometric Shape of Amorphous Silicon on the MILC Growth Rate (MILC 성장 속도에 비정질 실리콘의 기하학적 형상이 미치는 영향)

  • Kim Young-Su;Kim Min-Sun;Joo Seung-Ki
    • Korean Journal of Materials Research
    • /
    • v.14 no.7
    • /
    • pp.477-481
    • /
    • 2004
  • High quality polycrystalline silicon is very critical part of the high quality thin film transistor(TFT) for display devices. Metal induced lateral crystallization(MILC) is one of the most successful technologies to crystallize the amorphous silicon at low temperature(below $550^{\circ}C$) and uses conventional and large glass substrate. In this study, we observed that the MILC behavior changed with abrupt variation of the amorphous silicon active pattern width. We explained these phenomena with the novel MILC mechanism model. The 10 nm thick Ni layers were deposited on the glass substrate having various amorphous silicon patterns. Then, we annealed the sample at $550^{\circ}C$ with rapid thermal annealing(RTA) apparatus and measured the crystallized length by optical microscope. When MILC progress from narrow-width-area(the width was $w_2$) to wide-width-area(the width was $w_1$), the MILC rate decreased dramatically and was not changed for several hours(incubation time). Also the incubation time increased as the ratio, $w_1/w_2$, get larger. We can explain these phenomena with the tensile stress that was caused by volume shrinkage due to the phase transformation from amorphous silicon to crystalline silicon.

Analysis on the Chemical and Electrical Characteristic of Vegetable oil by Accelerated Aging (가속열화에 따른 식물성절연유의 화학적.전기적 특성 분석)

  • Choi, Sun-Ho;Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.984-989
    • /
    • 2011
  • Electrical insulation is one of the most important part in a high voltage apparatus. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. Accelerated aging transformer insulating material in vegetable oil was compared to that of mineral oil. Accelerated aging oil samples produced in the oven at $140^{\circ}C$ for 500, 1000, 1500, 2000hours. And Real transformer insulation oils samples of vegetable oil and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. Samples were analyzed at 42, 63, 93, 143, 190, 240, 300 cycles. The mineral and vegetable insulating oils were investigated for breakdown voltage, water content, total acid number, viscosity, volume resistivity, insulating paper and oil permittivity, and dissolved gas analyses. The breakdown voltage of the vegetable insulating oil is higher than that found for the mineral oil; the accelerated aging progress decreased the breakdown voltage. The vegetable oil had a higher water saturation than the mineral oil; the vegetable oil has the superior water characteristics and breakdown voltage. And high viscosity of vegetable oil, care has to be taken, especially when designing the cooling system for a large transformer.

Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter (광센서 점적계를 이용한 정맥내 주입률 조절기의 개발)

  • Yang, Y.S.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF

Development of the active magnetic regenerative refrigerator for room temperature application (상온 능동형 자기 재생 냉동기의 개발)

  • Park, I.;Kim, Y.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.60-64
    • /
    • 2012
  • In this paper, an investigation of a room temperature active magnetic regenerative refrigerator is carried out. Experimental apparatus includes two active magnetic regenerators containing 186 g of Gd spheres. Four E-type thermocouples are installed inside the Active magnetic regenerator(AMR) to observe the instantaneous temperature variation of AMR. Both warm and cold heat exchangers are designed for large temperature span. The cold heat exchanger, which separates the two AMRs, employs a copper tube with length of 80 mm and diameter of 6.35 mm. In order to minimize dead volume between the warm heat exchanger and AMRs, the warm heat exchangers are located close to the AMRs. The deionized water is used as a heat transfer fluid, and maximum 1.4 T magnetic field is supplied by Halbach array of permanent magnets. The AMR plate, which contains the warm and the cold heat exchangers and the AMRs, has reciprocating motion using a linear actuator and each AMR is alternatively magnetized and demagnetized by a Halbach array of permanent magnet. Since the gap of the Halbach array of permanent magnets is 25 mm and two warm heat exchangers have the motion through it, a compact printed circuit heat exchanger (PCHE) is used as a warm heat exchanger. A maximum no-load temperature span of 26.8 K and a maximum cooling power of 33 W are obtained from the fabricated Active Magnetic Regenerative Refrigerator (AMRR).

Reduction of Patient Dose in Radiation Therapy for the Brain Tumors by Using 2-Dimensional Vertex or Oblique Vertex Beam Technique

  • Kim, Il-Han;Chie, Eui-Kyu;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.225-231
    • /
    • 2003
  • Up-front irradiation technique as 3-dimensional conformation, or intensity modulation has kept large proportion of brain tumors from being complicated with acute radiation reactions in the normal tissue during or shortly after radiotherapy. For years, we've cannot help but counting on 2-D vertex beam technique to reduce acute reactions in the brain tumor patients because we're not equipped with 3-dimensional planning system. We analyzed its advantages and limitations in the clinical application. From 1998 to 2001, vertex or oblique vertex beams were applied to 35 patients with primary brain tumor and 25 among them were eligible for this analysis. Vertex(V) plans were optimized on the reconstructed coronal planes. As the control, we took the bilateral opposed techniques(BL) otherwise being applied. We compared the volumes included in 105% to 50% isodose lines of each plan. We also measured the radiation dose at various extracranial sites with TLD. With vertex techniques, we reduced the irradiated volumes of contralateral hemisphere and prevented middle ear effusion at contralateral side. But the low dose volume increased outside 100%; the ratio of V to BL in irradiated volume included in 100%, 80%, 50% was 0.55+/-0.10, 0.61+/-0.10, and 1.22+/-0.21, respectively. The hot area within 100% isodose line almost disappeared with vertex plan; the ratio of V to BL in irradiated volume included in 103%, 105%, 108% was 0.14+/-0.14, 0.05./-0.17, 0.00, respectively. The dose distribution within 100% isodose line became more homogeneous; the ratio of volume included in 103% and 105% to 100% was 0.62+/-0.14 and 0.26+/-0.16 in BL whereas was 0.16+/-0.16 and 0.02+/-0.04 in V. With the vertex techniques, extracranial dose increased up to $1{\sim}3%$ of maximum dose in the head and neck region except submandibular area where dose ranged 1 to 21%. From this data, vertex beam technique was quite effective in reduction of unnecessary irradiation to the contralateral hemispheres, integral dose, obtaining dose homogeneity in the clinical target. But it was associated with volume increment of low dose area in the brain and irradiation toward the head and neck region otherwise being not irradiated at all. Thus, this 2-D vertex technique can be a useful quasi-conformal method before getting 3-D apparatus.

The Settlement Characteristics of Waste Landfill Site by Consolidation Test (압밀시험에 의한 쓰레기매립지의 침하특성)

  • Shin, Bang-Woog;Lee, Bing-Jik;Bae, Woo-Seok;Lee, Jong-Kyu;Ahn, Byung-Chul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.35-42
    • /
    • 2000
  • The settlement characteristics of waste landfill site must be considered in the design of sanitary landfill as well as in the course of the rehabilitation of the landfill site. Among prediction methods for settlement of landfill site, especially Gibson and Lo model and Power Creep Law have been successfully applied to the landfill site where the amount of settlement was large and the secondary settlement was obvious. Therefore, the effects of organic content on the model parameter values utilized in both Gibson Lo model and Power Creep Law were studied by using a large consolidation testing apparatus. The organic content is each 20%, 40%, 60% of total volume and consolidation load is $0.1{\sim}1.6kg/cm^2$. The main results can be summarized as follows: (1) The reference compressibility of Power Creep Law is decreased according to the increments of consolidation load: (2) The field measurement is more similar to the Power Creep Law than the Gibson and Lo model.

  • PDF

Phase Transition Study on Ilmenite under High Pressure and Temperature (고온-고압하에서 티탄철석에 대한 상면이 연구)

  • Kim, Young-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.161-169
    • /
    • 2002
  • high pressure and temperature conditions. However, those results are not consistent with one another, and phase boundary between ilmenite and perovskite phases determined only from the quenching method may be not so reliable at all. Therefore, in-situ high pressure-temperature (hP-T) X-ray diffraction measurements were performed up to 19 GPa and $700^{\circ}C$ in a large volume press apparatus using synchrotron radiation. Experimental results show that perovskite phase is stable at pressures above 16 GPa, and transforms back to $LiNbO_3$phase near 15 CPa at room temperature, and that the perovskite-ilmenite transition is back and forth near 15 CPa at $500^{\circ}C$. LiNbO$_3$phase transforms to ilmenite at 13 CPa and $300^{\circ}C$ and at 10.8 CPa and $400^{\circ}C$, respectively. These data indicate that $LiNbO_3$phase may have a stability region in the hP-T phase diagram and that the perovskite-ilmenite phase boundary would be quite different from that previously reported.