• 제목/요약/키워드: large source

검색결과 2,518건 처리시간 0.032초

Comparison of Biot-Savart's Law and 3D FEM in the Study of Electromagnetic Forces Acting on End Winding

  • Kim, Ki-Chan
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.369-374
    • /
    • 2011
  • An induction motor operated with high voltage source generally generates high current in starting mode and has a long transient time after being started. This large and sustaining starting current causes the end windings of the stator to have excessive electromagnetic force. This force is the source of vibration and has a negative and serious influence on the insulation of end windings. Therefore, designing the end winding part with an appropriate support system is needed. To design the support ring enclosing the end windings, we analyze the distribution of electromagnetic force on the end windings by applying the Biot-Savart's law and the 3D finite element method (FEM), and comparing two simulation methods. Finally, we verify the safety of the support structure of the end winding part using stress analysis, which is analyzed with the electromagnetic forces from the 3D FEM simulation.

Digital Tomosynthesis using a Flat-panel Detector based Micro-CT

  • Mandai, Koushik Kanti;Choi, Jeong-Min;Cho, Min-Hyoung;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권5호
    • /
    • pp.364-370
    • /
    • 2008
  • Recent development in large area flat-panel x-ray detector technology enables clinical application of digital tomosyntesis. Unlike conventional motion tomography using x-ray films, flat-panel x-ray detectors provide projection images in digital formats so that tomographic images can be synthesized in a more flexible way. For the digital tomosynthesis, precise movements of the x-ray source and the x-ray detector with respect to a fulcrum point are necessary. In this study, we apply the digital tomosynthesis technique to the flat-panel detector based micro-CT in which the flat-panel detector and the x-ray source rotate together on a circular arc. The experimental results suggest that flat-panel detector based 3D CTs can be used for digital tomosynthesis in the clinical environment.

면외변위 측정을 위한 홀로그래픽 간섭계의 민감도백터의 오차 해석 (Analysis on the error of sensitivity vector of holographic interferometer for measuring out-of-plane displacement)

  • 문상준;강영준;백성훈;김철중
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.515-518
    • /
    • 1994
  • Holographic interferometry is a useful whole-field nondestructive testing for measuring deformations and vibrations of engineering structure. A diverging beam is used as a light source int the most of holographic interferometer practically. For a relatively small object the optical arrangement using a collimated light source has no difficulty in use technically, but for a large object it is difficult to use a collimated beam. In this study we calculate the error of measured displacement from the sensitivity vector dominated by the geometry of optical arrangement for holographic interferometer and show the result obtained with 2-D plots. A Plane surface and a cylindrical surface were chosen as objects to be calculated and computer analysis was carried out for the cases of a diverging beam and a collimated one.

  • PDF

해상용 대형 가스터빈의 소음 저감을 위한 흡음형 소음기의 설계 및 성능 측정 (Design and Measurement of Dissipative Silencers for Noise Reduction of Large Maritime Gas Turbine Engines)

  • 백성현;이강희;권대훈;이일재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.367-371
    • /
    • 2014
  • Based on ISO 7235, an experimental setup to measure the acoustic performance of splitter type dissipative silencers are fabricated. The length of each duct, sound source, microphone locations, modal filter, and anechoic termination are considered in the design of this setup. The modal filter is a particularly important factor because it affects the limit of measurement, which is also determined by the amount of flanking transmission of sound generated by the sound source to microphones. The effects of absorptive materials, media which covers the materials, and the number of splitters on the noise reduction of the sample silencers are experimentally investigated. The insertions loss of silencers with media and higher number of splitters increases, especially at higher frequencies.

  • PDF

왕복동식 컴프레셔의 진동 저감 사례 (Vibration Reduction of Reciprocating Compressor)

  • 채상일;김병수;임우섭;양보석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.779-783
    • /
    • 2012
  • The gas compressor is one of the important machine in the petrochemical industry. It is likely to have high vibration problems due to having large reaction source and structural characteristic. In this paper we analyze the cause of high vibration in the reciprocating compressor and present a solution to this problems. By performing this case study, we confirm the effectiveness of vibration reduction through excitation source changes.

  • PDF

Analysis of Quantum Effects Concerning Ultra-thin Gate-all-around Nanowire FET for Sub 14nm Technology

  • 이한결;김성연;박재혁
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제4회(2015년)
    • /
    • pp.357-364
    • /
    • 2015
  • In this work, we investigate the quantum effects exhibited from ultra-thin GAA(gate-all-around) Nanowire FETs for Sub 14nm Technology. We face designing challenges particularly short channel effects (SCE). However traditional MOSFET SCE models become invalid due to unexpected quantum effects. In this paper, we investigated various performance factors of the GAA Nanowire FET structure, which is promising future device. We observe a variety of quantum effects that are not seen when large scale. Such are source drain tunneling due to short channel lengths, drastic threshold voltage increase caused by quantum confinement for small channel area, leakage current through thin gate oxide by tunneling, induced source barrier lowering by fringing field from drain enhanced by high k dielectric, and lastly the I-V characteristic dependence on channel materials and transport orientations owing to quantum confinement and valley splitting. Understanding these quantum phenomena will guide to reducing SCEs for future sub 14nm devices.

  • PDF

VCC를 첨가한 다중 전류형 인버터 구동에 관한 연구 (A Study on Drive of the Multicurrent Source Inverter Inserting the VCC)

  • 정연택;홍일선;황락훈
    • 대한전기학회논문지
    • /
    • 제38권4호
    • /
    • pp.269-278
    • /
    • 1989
  • When the induction motor is operated by CSI, the commutation capacitance in the CSI circuit is increased according to the increase of large capacitor system. The output voltage spikes are generated at the moment of charge and discharge of the commutation capacitor. Also, since output current comprise a great number of harmonics, torque ripples of the motor are generated, having bad effects on the motor. In this study, by adopting the 18-phase multiple high Frequency Current Source Inverter (HFCSI), torque ripples generated by the voltage spikes are mostly eliminated except the 17th and 19th harmonics. To reduce the voltage spikes comprised in the output voltage, particularly, the methods of eliminating the cause of bad effect upon the motor are proposed in this paper. In the proposed method, by using additional voltage Clamping Curcuit (VCC), it is possible to select the values of commutation capacitor energy loss in commutating, the commutating capacitor, and the capacitor in the clamping circuit.

자려식 SVC용 5레벨 인버터의 직류측 콘덴서 전압제어에 관한 연구 (A study on the DC Capacitor Voltage control of 5 Level Inverter for Static Var Compensator)

  • 김종윤;;류승각;오진석;김윤식;노창주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1899-1901
    • /
    • 1998
  • A five-level VSI(Voltage Source Inverter) is introduced as a SVC(Static Var Compensator) like a large scale power source. The problems in using SVC are that the power device can easily be destroyed by voltage unbalance and accurate reactive power control is difficult because of voltage variation. A asymmetrical PAM(Pulse Amplitude Modulation) switching pattern is proposed to solve this problem and analyze both fundamental component and harmonic current in the system. Through experimental results of 3.5 kVA experimental test system. It is confirmed that DC capacitor voltage can be controlled by asymmetrical PAM switching pattern control.

  • PDF

STATUS OF THE PSHA IN KOREA FOR NUCLEAR POWER PLANT SITES

  • Seo, Jeong-Moon;Noh, Myung-Hyun;Chang, Chun-Joong;Yun, Kwan-Hee
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1255-1262
    • /
    • 2009
  • This paper introduces the status of and issues related to the PSHA (Probabilistic Seismic Hazard Analysis) of Korean Nuclear Power Plant sites. PSHA was first introduced to the nuclear industry in the mid-1980s. The Korean PSHA is based on Cornell and accommodates the modem approach for eliciting expertise and statistical treatment. Due to the low seismicity in Korea, large uncertainties exist in the PSHA database including seismic source maps, seismicity parameters of seismic sources, and attenuation formulae. Though research in seismology, geology, and earthquake engineering since the mid-1990s has significantly reduced uncertainties, a considerable amount still exists. Considering the low seismicity of the Korean Peninsula, especially the lack of strong motion data, further reduction will take several decades.

규칙파중을 항행하는 선박의 유탄성응답해석 (A Hydroelastic Response Analysis of Ships with Forward Speed in Regular Waves)

  • 이승철;배성용
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.48-55
    • /
    • 2010
  • When a large ship is advancing in waves, ship undergoes the hydroelastic response, which has influences on structural stability and the fatigue destruction etc. of the ship. Therefore, to predict accurate hydroelastic response, it is necessary to analyze hydroelastic response including fluid-structure interaction. In this research, a ship is divided into many hull elements to calculate the fluid forces and wave exciting forces on each elements using three-dimensional source distribution method. The calculated fluid forces and wave exciting forces are assigned to nodes of hull elements. The neighbor nodes are connected with elastic beam elements. We analyzed hydroelastic responses, and those are formulated by using finite element method. Particularly, to estimate the influence of forward speed on the hydroelastic responses, we use two different methods : Full Hull Rotation Method(FHRM) and Sectional Hull Rotation Method(SHRM).