• Title/Summary/Keyword: large size area

Search Result 1,253, Processing Time 0.026 seconds

Donor Site Morbidity after Sural Nerve Harvesting for Peripheral Nerve Reconstruction (장딴지 신경이식술 후 공여부 합병증에 대한 연구)

  • Chang, Jung-Woo;Choi, M. Seung-Suk;Lee, Jang-Hyun;Ahn, Hee-Chang;Kang, Nak-Heon
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.421-426
    • /
    • 2011
  • Purpose: Although the sural nerve is the most commonly used donor for autologous nerve graft, its morbidity after harvesting is sparsely investigated. The sural nerve being a sensory nerve, complications such as sensory changes in its area and neuroma can be expected. This study was designed to evaluate the donor site morbidity after sural nerve harvesting. Methods: Among the 13 cases, who underwent sural nerve harvesting between January 2004 and August 2009, 11 patients with proper follow up were included in the study. The collected data included harvested graft length, actual length of the grafted nerve, anesthetic and paresthetic area, presence of Tinel sign and symptomatic neuroma, and scar quality. Results: In 7 patients, no anesthetic area could be detected. Of the patients with a follow up period of more than 2 years, all the patients showed no anesthetic area except two cases who had a very small area of sensory deficit ($225mm^2$) on the lateral heel area, and large deficit ($4,500mm^2$) on the lateral foot aspect. The patients with a short follow up period (1~2 m) demonstrated a large anesthetic skin area ($6.760mm^2$, $12,500mm^2$). Only one patient had a Tinel sign. This patient also showed a subcutaneous neuroma, which was visible, but did not complain of discomfort during daily activities. One patient had a hypertrophic scar in the retromalleolar area, whereas the two other scars on the calf were invisible. Conclusion: After a period of 2 years the size of anesthetic skin in the lateral retromalleolar area is nearly zero. It is hypothesized that the size of sensory skin deficit may be large immediately after the operation. This area decreases over time so that after 2 years the patient does not feel any discomfort from nerve harvesting.

A Study on the Size Distribution and Chemical Composition of total Suspended Particulates at Industrial Region (공단지역에서 대기중 총 부유분진의 입자크기 분포와 화학적 성분에 관한 분석과 연구)

  • Park, Heung-Jae;Lee, Seong-Uk;Park, Won-U
    • Journal of Environmental Science International
    • /
    • v.2 no.3
    • /
    • pp.201-206
    • /
    • 1993
  • The concentration of Total Suspended Particulates(T.S.P), size distribution of suspended particulates, and soluble anions of T.S.P in atmosphere of industrial region in Busan were investigated. T.S.P was measured by High-Volume Air Sampler and particle size distribution was measured by Anderson Air Sampler. We analyzed the chemical component of the T.S.P by ion Chromatography and measure4 the shape and size of T.S.P by Scanning Electron Micrography The small size of T.S.P mainly exist in industrial region, but the large size of T.S.P mainly exist in residentail area.

  • PDF

Application of Local Axial Flaps to Scalp Reconstruction

  • Zayakova, Yolanda;Stanev, Anton;Mihailov, Hristo;Pashaliev, Nicolai
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.564-569
    • /
    • 2013
  • Background Scalp defects may be caused by various etiological factors, and they represent a significant surgical and aesthetic concern. Various surgical techniques can be applied for reconstructive work such as primary closure, skin grafting, pedicled or free flaps. In this article, the authors share their clinical experience with scalp operations using the technique of local flaps and discuss the application of this method from the perspective of not only the size of the defect, but also in relation to the anatomical area, quality of surrounding tissue, and patient's condition. Methods During the period from December 2007 to December 2012, 13 patients with various scalp defects, aged 11 to 86 years, underwent reconstruction with local pedicle flaps. The indications were based on the patients' condition (age, sex, quality of surrounding tissue, and comorbidities) and wound parameters. Depending on the size of the defects, they were classified into three groups as follows: large, 20 to 50 $cm^2$; very large, 50 to 100 $cm^2$; extremely large, 100 $cm^2$. The location was defined as peripheral (frontal, temporal, occipital), central, or combined (more than one area). We performed reconstruction with 11 single transposition flaps and 1 bipedicle with a skin graft on the donor area, and 2 advancement flaps in 1 patient. Results In all of the patients, complete tissue coverage was achieved. The recovery was relatively quick, without hematoma, seroma, or infections. The flaps survived entirely. Conclusions Local flaps are widely used in scalp reconstruction since they provide healthy, stable, hair-bearing tissue and require a short healing time for the patients.

Care-giver's Needs and Evaluation on the Actual Condition of the Playgrounds in Child Care Facilities (보육시설의 실외놀이 환경실태 및 환경특성에 대한 교사의 평가와 요구)

  • Choi, Mock-Wha;Byun, Hea-Ryun
    • Journal of the Korean housing association
    • /
    • v.19 no.6
    • /
    • pp.105-114
    • /
    • 2008
  • The purpose of this study is to classify playground types according to the physical characteristics of playgrounds in child care facilities, to analyze the needs of care-givers and to evaluate the adequacy of playgrounds according to playground types. The specific areas discussed in this study were the evaluation of the adequacy in the physical characteristics of playgrounds for children's outdoor play activities by the care-givers, who assist in the outdoor play activities of children and manage safety in the playground, and a report on playground requirements of them. Data was collected from field survey carried out to investigate the physical characteristics of playgrounds of 21 child care facilities. This survey incorporated a structured-questionnaire for the purpose of evaluating the adequacy of the physical characteristics of playgrounds (location and size of the playground, play equipments, the composition of play areas, ground covers, and location of sidewalk in the playground) by the 181 care-givers from the facilities and investigating the needs of them. The major results showed the following. 1) In field survey, it was observed that while the location and the size of the playgrounds varied widely, ground cover, play equipments, and the composition of play area turned out to be identical, regardless of the location and the size of the playgrounds. 2) The playgrounds were classified into five types according to the number of children and the size of the playground. The five types include A-type as a large-scale facility/smallsize playground, B-type as a small-scale facility/large-size playground, C-type as a small-scale facility/small-size playground, D-type as a middle-scale facility/large-size playground, and E-type as a large-scale facility/large-size playground. 3) The adequacy of the physical characteristics of playground in the D-type was evaluated to be higher than that of the other types. The adequacy of the C-type playground was evaluated to be lower than that of the other types in terms of size and the composition of play areas within the playground. 4) The care-givers of the D-type and the E-type playground expressed a desire to install various play equipments, while the care-givers of the C-type playground did not wish to install play equipment. 5) Various outdoor play areas were needed in the D-type playground.

A Novel Large Area Negative Sputter Ion Beam source and Its Application

  • Kim, Steven
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.73-73
    • /
    • 1999
  • A large area negative metal ion beam source is developed. Kinetic ion beam of the incident metal ions yields a whole nucleation and growth phenomena compared to the conventional thin film deposition processes. At the initial deposition step one can engineer the surface and interface by tuning the energy of the incident metal ion beams. Smoothness and shallow implantation can be tailored according to the desired application process. Surface chemistry and nucleation process is also controlled by the energy of the direct metal ion beams. Each individual metal ion beams with specific energy undergoes super-thermodynamic reactions and nucleation. degree of formation of tetrahedral Sp3 carbon films and beta-carbon nitride directly depends on the energy of the ion beams. Grain size and formation of polycrystalline Si, at temperatures lower than 500deg. C is obtained and controlled by the energy of the incident Si-ion beams. The large area metal ion source combines the advantages of those magnetron sputter and SKIONs prior cesium activated metal ion source. The ion beam source produces uniform amorphous diamond films over 6 diameter. The films are now investigated for applications such as field emission display emitter materials, protective coatings for computer hard disk and head, and other protective optical coatings. The performance of the ion beam source and recent applications will be presented.

  • PDF

AAO Template Morphology Controlled by Variation of Anodizing Condition (양극 산화 조건 변화에 따른 AAO Template Morphology 제어)

  • Jo, Ye-Won;Lee, Sung-Gap;Kim, Kyeong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.249-251
    • /
    • 2015
  • In this study, the application of biosensor having a large surface area for more effective and AAO (anomic aluminium oxide) template in order to gain concentration and voltage of anodizing process morphology changes to the control of experiments were conducted. The biosensor surface may increase the response characteristics by having a large surface area. So the entrance to a little more efficient wide depth sensing experiment was carried out to obtain a structure body with a branch shape with a large surface area with increasing. Experimental results from the FE-SEM observation was obtained template morphology. As a result, depending on the anodizing time, the depth of the layer of aluminum oxide was found that it was confirmed that the deepening of the pore size changes according to anodizing condition. And measuring the detection performance according to the conditions in the electrolyte and the reaction because of blood using a biosensor measuring sensing property according to the depth of the pore depth is considered that does not have a significant impact.

Continuous Measurements of Size Separated Atmospheric Aerosol Number Concentration in Background Area (대기배경지역 에어로졸의 입경별 수농도 연속 측정)

  • Kang, Chang-Hee;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.21 no.4
    • /
    • pp.535-543
    • /
    • 2012
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan site, which is known as background area in Korea, from January to September 2011. The temporal variation and the size distribution of aerosol number concentration have been investigated. The entire averaged aerosol number concentration in the size range 0.25~32.0 ${\mu}m$ is about 252 particles/$cm^3$. The number concentration in small size ranges(${\leq}0.5{\mu}m$) are very higher than those in large size ranges, such as, the number concentration in range of larger than 6.5 ${\mu}m$ are almost zero particles/$cm^3$. The contributions of the number concentration to PM10 and/or PM2.5 are about 34%, 20.1% and 20.4% in the size range 0.25~0.28 ${\mu}m$, 0.28~0.30 ${\mu}m$ and 0.30~0.35 ${\mu}m$, respectively, however, the contributions are below 1% in range of larger than 0.58 ${\mu}m$. The monthly variations in the number concentration in smaller size range(<1.0 ${\mu}m$) are evidently different from the variations in range of larger than 1.0 ${\mu}m$, but the variations are appeared similar patterns in smaller size range(<1.0 ${\mu}m$), also the variations in range of larger than 1.0 ${\mu}m$ are similar too. The diurnal variations in the number concentration for smaller particle(<1.0 ${\mu}m$) are not much, but the variations for larger particle are very evident. Size-fractioned aerosol number concentrations are dramatically decreased with increased particle size. The monthly differences in the size-fractioned number concentrations for smaller size range(<0.7 ${\mu}m$) are not observed, however, the remarkable monthly differences are observed for larger size than 0.7 ${\mu}m$.

Relationship between Morphological and Physiological Characters of White Clover Cultivars with Different Leaf Size (잎의 크기가 다른 White Clover 품종들의 몇가지 형태 및 생리적 특성간의 관계)

  • ;Geoffrey B. Brink
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.15 no.4
    • /
    • pp.259-264
    • /
    • 1995
  • Several benefits provided by white clover (Tnifoliurn repens L.) can be elevated as relationship between its morphological and physiological characteristics is clarified. The experiment was done to analyze the relationship between them in the clover with different leaf size. Individual plants of Osceola (large leaf), Grasslands Huia (medium leaf) and Aberystwyth S184 (small leaf) were grown in 15m plastic pot containing a 1:2:1 soil:sand:Promix mixture for 55 days, and then clipped to remove all fully expanded leaves every 7, 14 or 28 days. To measure the cultivar response, plants were sampled for morphological and physiological parameters on the date (0) after final harvest and 1, 3, 7, 14 and 28 days after the final harvest and then their relationship was analyzed. Osceola had greater leaf area per trifoliolate but less no. of leaves per plant to result in similar total leaf area per plant of all cltivars. Stolon length and no. of growing tips per plant declined with smaller leaf size although the result in biomass was reverse. Stolon of all cultivars showed the greatest fluctuation in total nonstructud carbohydrate during the regrowing period but nitrogen concentrations of all their fractions and dinitrogen fixation did similar patterns. Stolon and root of Osceola, moreover, were the highest ones. Biomass, stolon length and total leaf area per plant of all cultivars were positively correlated to carbohydrate concentration of all frauions and dinitrogen fixation. In Osceola relationship between nitrogen concentration of stolon and the characters showed in Osceola was positively done.

  • PDF

Feeding Habits of Paralichthys olivaceus in the Uljin Marine Ranching Area (동해 울진바다목장에 서식하는 넙치(Paralichthys olivaceus)의 식성)

  • Choi, Jung-Hwa;Yoon, Sang-Cheoul;Lee, Sung-Il;Kim, Jong-Bin;Kim, Hye-Rim
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.6
    • /
    • pp.684-688
    • /
    • 2011
  • The feeding habits of Paralichthys olivaceus in the Uljin marine ranching area, located on the mid-eastern coast of Korea, were studied from January to November 2009. In total, 381 specimens were collected; fish ranged in size from 15.4 to 59.0 cm in total length. P. olivaceus is a carnivore, mainly consuming other fishes and crustaceans. The prey items of P. olivaceus changed ontogenetically. Small individuals fed on decapod crustaceans while large ones fed heavily on other fishes. The diet of P. olivaceus varied seasonally. Fish comprised the main prey items throughout the year. The stomach contents index (SCI) of each size class increased and the dietary breadth index (DBI) of each size class decreased as individuals grew.

An Efficient List Successive Cancellation Decoder for Polar Codes

  • Piao, Zheyan;Kim, Chan-Mi;Chung, Jin-Gyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.550-556
    • /
    • 2016
  • Polar codes are one of the most favorable capacity-achieving codes due to their simple structure and low decoding complexity. However, because of the disappointing decoding performance realized using conventional successive cancellation (SC) decoders, polar codes cannot be used directly in practical applications. In contrast to conventional SC decoders, list SC (SCL) decoders with large list sizes (e.g. 32) achieve performances very close to those of maximum-likelihood (ML) decoders. In SCL decoders with large list sizes, however, hardware increase is a severe problem because an SCL decoder with list size L consists of L copies of an SC decoder. In this paper, we present a low-area SCL decoder architecture that applies the proposed merged processing element-sharing (MPES) algorithm. A merged processing element (MPE) is the basic processing unit in SC decoders, and the required number of MPEs is L(N-1) in conventional SCL decoders. Using the proposed algorithm reduces the number of MPEs by about 70% compared with conventional SCL decoders when the list size is larger than 32.