• Title/Summary/Keyword: lambda test

Search Result 161, Processing Time 0.028 seconds

Application of sound scattering models to swimbladdered fish, red seabream (Chrysophys major)

  • Kang Donhyug;Hwang Doojin;Na Jungyul;Kim Suam
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.233-236
    • /
    • 2000
  • The acoustical response of fish depends on size and physical structure na, most important, on the presence or absence of a swimbladder. Acoustic scattering models for swimbladdered fish represent a fish by an ideal pressure-release surface having the size and shape as the swimbladder. Target strength experiments of red seabream (Chrysophrys major) have been conducted using 38 (split-beam), 120 (split-beam) and 200kHz (dual-beam) frequencies. At each start of each experiment, the live fish are placed in the cage at the surface, then the cage is lowed to about $4{\cal}m$ depth where it remains during the measurements. To test the acoustic models, predictions of target strength based on swimbladder morphometries of 10 red seabream offish total length from $103{\cal}mm{\;}to{\;}349{\cal}mm$ ($3 <$TL/\lambda$ < 45)are compared with conventional target strength measurements on the same, shock-frozen immediately after caged experiments. X-ray was projected along dorsal aspect to know the morphological construction of swimbladder. and fish body. At high frequencies, Helmholtz-kirchhoff(HK) approximation would greatly enhance swimbladdered fish modeling. Sound scattering model [HK-ray approximation model] for comparison to experimental target strength data was used to model backscatter measurements from individual fish. The scattering data can be used in the inverse method along with multiple frequency sonar systems to investigate the adequacy of classification and identification of fish

  • PDF

A Study on NOx Reduction Characteristics of LNT Catalyst with Fuel Injection Control in Light-duty Diesel Engine (승용디젤엔진의 연료분사 제어를 통한 LNT 촉매의 NOx 저감 특성에 관한 연구)

  • Hwang, Seung-Kwon;Ko, A-Hyun;Yoon, Joo-Wung;Myung, Cha-Lee;Park, Sim-Soo;Kim, Eun-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.150-155
    • /
    • 2012
  • Lean NOx Trap (LNT) catalysts are capable of reducing exhaust NOx emissions from diesel engines. LNT stores NOx in lean condition and exhausts N2 by reducing NOx in rich condition. NOx reduction characteristic of LNT catalysts using throttle position sensor and fuel injection timing control for light-duty diesel engine was investigated. In contrast to SCR system, LNT catalyst uses diesel fuel in resuctant. Also if the concentration of reductant is exceeded, excessive amount of reductant will slip throughout LNT and cause another emission problem. Thus LNT regeneration with precise engine control established that can make higher NOx conversion efficiency and lower fuel penalty, prevent another emission problem. NOx and reductant concentration were measured by the NOx sensor and Mexa7100D equipped inlet and outlet of catalyst. As a result of engine test, regeneration strategy has reached high of 77.8% NOx conversion efficiency according to engine operation condition. Moreover, we have proved that it is possible to use regeneration strategy of LNT within 5% fuel penalty.

Compensating algorithm of the secondary voltage for CCVT considering the hysteresis of a iron core (철심의 히스테리시스 특성을 고려한 CCVT 2차 전압 보상방법)

  • Kang, Y.C.;Lee, B.E.;Zheng, T.Y.;Lee, J.H.;Kim, Y.H.;Park, J.M.;So, S.H.;Jang, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.261-263
    • /
    • 2005
  • In the extra and ultra high voltage system, the coupling capacitor voltage transformer (CCVT) measures the primary voltage with a small scale of voltage transformer (VT). However, the CCVT generates errors caused by the hysteresis characteristics of iron core and by the ferroresonance, inevitably. This paper proposes a compensation algorithm for the secondary voltage of a CCVT considering the hysteresis characteristics of an iron core. The proposed algorithm calculates the seconda교 current of a VT by summing the current flowing the ferroresonance circuit and the burden current; it estimates the secondary voltage of a VT; then the core flux is calculated by integrating of the secondary voltage of a VT, then estimates the exciting current using ${\lambda}-i$ characteristic of the core. The method calculates a primary voltage of a VT considering the estimated primary current. Finally, the correct voltage is estimated by compensating the voltage across the inductor and capacitor. The performance of the proposed algorithm was tested in a 345kV transmission system. The test results show that the proposed method can improve the accuracy of the seconda교 voltage of a CCVT.

  • PDF

DEVELOPMENT OF 230 GHZ RADIO RECEIVER SYSTEM FOR SRAO

  • Lee, Jung-Won;Kim, Chang-Hee;Kang, Hyunwoo;Lee, Bangwon;Han, Junghwan;Lee, Seok-Ho;Jeong, Il-Gyo;Koo, Bon-Chul;Park, Yong-Sun
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.6
    • /
    • pp.225-234
    • /
    • 2013
  • We develop a radio receiver system operating at ${\lambda}{\sim}1.3$ mm for the 6 m telescope of Seoul Radio Astronomy Observatory. It consists of a dual polarization receiver, a couple of IF processing units, two FFT spectrometers, and associated software. By adopting sideband-separating superconductor mixers with image band terminated to waveguide load at 4.2 K, we achieve $T_{RX}{\leq}100$ K and $T_{sys}$ less than 150 K at best weather condition over 210-250 GHz frequency range. The intermediate frequency signal of 3.5-4.5 GHz is down converted to 0-1 GHz and fed into the FFT spectrometers. The spectrometer covers 1 GHz bandwidth with a spectral resolution of 61 KHz. Test observations are conducted toward several radio sources to evaluate the performance of the system. Aperture and beam efficiencies measured by observing planets are found to be typically 44 ~ 59% and 47 ~ 61%, respectively over the RF band, which are consistent with those measured at 3 mm band previously.

CONSTRAINING COSMOLOGICAL PARAMETERS WITH IMAGE SEPARATION STATISTICS OF GRAVITATIONALLY LENSED SDSS QUASARS: MEAN IMAGE SEPARATION AND LIKELIHOOD INCORPORATING LENS GALAXY BRIGHTNESS

  • Han, Du-Hwan;Park, Myeong-Gu
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.1
    • /
    • pp.83-92
    • /
    • 2015
  • Recent large scale surveys such as Sloan Digital Sky Survey have produced homogeneous samples of multiple-image gravitationally lensed quasars with well-defined selection effects. Statistical analysis on these can yield independent constraints on cosmological parameters. Here we use the image separation statistics of lensed quasars from Sloan Digital Sky Survey Quasar Lens Search (SQLS) to derive constraints on cosmological parameters. Our analysis does not require knowledge of the magnification bias, which can only be estimated from the detailed knowledge on the quasar luminosity function at all redshifts, and includes the consideration for the bias against small image separation quasars due to selection against faint lens galaxy in the follow-up observations for confirmation. We first use the mean image separation of the lensed quasars as a function of redshift to find that cosmological models with extreme curvature are inconsistent with observed lensed quasars. We then apply the maximum likelihood test to the statistical sample of 16 lensed quasars that have both measured redshift and magnitude of lens galaxy. The likelihood incorporates the probability that the observed image separation is realized given the luminosity of the lens galaxy in the same manner as Im et al. (1997). We find that the 95% confidence range for the cosmological constant (i.e., the vacuum energy density) is $0.72{\leq}{\Omega}_{\Lambda}{\leq}1.0$ for a flat universe. We also find that the equation of state parameter can be consistent with -1 as long as the matter density ${\Omega}_m{\leq}0.4$ (95% confidence range). We conclude that the image separation statistics incorporating the brightness of lens galaxies can provide robust constraints on the cosmological parameters.

Study about Oriental Medical Diagnosis and Approach Related to Weighting According to Differentiation of Chronic Tension-type Headaches (만성 긴장성 두통의 한의학적 진단 및 변증의 가중치에 대한 접근방법 연구)

  • Lee, Ki-Su;Kim, Min-Jung;Park, Mi-Ra;Lee, Sang-Bong;Hong, Kwon-Eui
    • The Journal of Korean Medicine
    • /
    • v.31 no.5
    • /
    • pp.41-59
    • /
    • 2010
  • Objective: Headache is one of the most common symptoms in primary medical care. The purpose of this study was to support medical treatment by consideration of a new CTTH (chronic tension-type headache) oriental medical diagnosis index. Methods: An Oriental medical diagnosis questionnaire was administered to a CTTH group, migraine group and normal group. The result was classified by using LDA, CART, factor diagnosis and tested in comparison with the original diagnosis. Also, weighting method based on expert opinions was done. Results: 1. The result analyzed by using LDA has an accuracy of 93.9% in comparison with the original diagnosis. 2. High accuracy showed when the test was performed with about 35 significant questions and four questions selected based on SPSS Wilks' lambda. 3. There was accuracy of 90.9% when differentiation was performed by using CART compared with original diagnosis. 4. 10 factors has a high initial value after factor analysis, consisting of questions to the similar differentiation. 5. Diagnosis formula of headache was made by using weighting method based on expert opinions. Conclusion: Oriental medical diagnosis questionnaires make it possible to classify headaches significantly. The study about weighting method of CTTH can make it possible to classify symptoms more accurately.

Specular Reflectance Measurements of Dielectric Plates in Millimeter Frequency Range

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Kwang Yong;Yoon, Dae Hwan;Park, Sung Won
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.78-87
    • /
    • 2018
  • This paper describes specular reflectance measurements of dielectric plates in three waveguide frequency bands: D-band (110-170 GHz), G-band (140-220 GHz), and J-band (220-325 GHz). The transmit (Tx) part of the proposed specular reflectance measurement system is stationary, while the receive (Rx) part and the material under test (MUT) holder are concentric-rotating with a 2:1 speed ratio for specular reflectance measurements. In specular reflectance measurements, the first step measures the specular reflection coefficients of an MUT and a metal plate on the MUT holder located at the center of the Tx and Rx parts, and the second step calculates the specular reflectance defined by the specular reflection power (i.e., intensity) of the MUT normalized to that of the metal plate. Multiple reflection effects between the Tx and Rx antennas and the MUT on the measured specular reflectance are minimized by averaging out the multiple specular reflectances measured with changing the separation distance between the two antennas by ${\lambda}/8$ intervals. Measurement results of the perpendicular-polarized specular reflectance of commonly used dielectric plates are verified by comparing those with the analytic results and show that the results measured over the overlapped frequency range of the D-/G-bands and at the boundary frequency of the G-/J-bands agree well with the results for the other band, respectively.

Psychological, Physical and Genetic Traits of Sasang Typology (사상인(四象人)의 생리적 특성 연구)

  • Chae, Han;Hong, Moo-Chang;Bae, Hyun-Su;Shin, Min-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.304-314
    • /
    • 2005
  • The major concept of Sasang typology is that the disease susceptibility and drug response as well as physiological characteristics are presumed to be different depending on their Sasang types. Although characterizing fundamental basis of their traits are crucial in this research field, only pathological susceptibility and physical appearances were thoroughly studied. We evaluated their physiological characteristics by tapping psychological, physical and genetic traits of each Sasang types. After determining the Sasang type of one hundred three college students based on the Questionnaire for the Sasang Constitution Classification, the psychological, physical and genetic traits of each type were analyzed with the Myers-Briggs Type Indicator (MBTI), Bioelectrical Impedance Analysis and genetic polymorphism test, respectively. Each of the Sasang types showed significantly different profiles (Generalized estimation equation, coef=11.88, z=2.13, p=0.033), and could be distinctively classified based on their MBTI scores (discriminant analysis Wilks Lambda=0.611, df=8, chi-square=36.7, p<0.001). Subjects with the So-Eum type (Introversion and Judging) and the So-Yang type (Extroversion and Perceiving) showed contrasting psychological features, however they had similar anthropometric characteristics. Subjects with the Tae-Eum type showed bigger Body Mass Index ($R^2$=0.22, df=4, 74, F=5.07, p=0.001) and body shape compared to others. Although there were no significant differences in G-protein beta-3 subunit polymorphism, angiotensin-converting enzyme polymorphism and Methylenetetrahydrofolate reductase polymprhisms among groups with Sasang types, it was shown that the dopamine system could be one for genetic marker for Sasang typology. These results demonstrated distinctive and essential traits of Sasang typology using reproducible psychometric, anthropometric and genetic evaluations. We also found that the Sasang typology was a bio-psychological typology which could show trait-specific guideline for individualized medicine.

The Study of Long-Term Performance Evaluation of Vacuum Insulation Panel(VIP) with Accelerated Aging Test (가속노화 시험을 통한 진공단열패널(VIP)의 장기성능 평가 연구)

  • Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.35-47
    • /
    • 2017
  • Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP) is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been applied in buildings for over a decade, it wasn't until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing of VIP. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot box method) and long-term durability was estimated based on a non-linear pressure-humidity dependent equation based on study of IEA/ECBCS Annex 39, with the aim of assessing durability of VIP for use in buildings. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90 % for the thermal conductivity (${\lambda}90/90$) ranged from 0.00726-0.00814 (W/m K) for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.

Visualization of Self-Healing Function of Protective Coating for Concrete (콘크리트 보호코팅재의 자기치유 기능의 시각화)

  • Kim, Dong-Min;Choi, Ju-Young;Jin, Seung-Won;Nam, Kyeong-Nam;Park, Hyeong-Joo;Chung, Chan-Moon
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.10
    • /
    • pp.87-93
    • /
    • 2019
  • Microcapsules were prepared by using a mixture of linseed oil and a small amount of fluorescent fluid as a core material. Self-healing protective coatings were prepared by applying coating formulations containing varying amounts of microcapsules on mortar surface. After scratch or crack was generated in the coating, when the damaged region was exposed to ultraviolet light (${\lambda}=365nm$), it was observed that fluorescence emission area increased with increasing microcapsule loading. In the cases of the self-healing coatings having 20wt% or more microcapsule loading, the damaged region was almost filled with the healing agent. In water sorptivity test, the self-healing coating having 20wt% or more microcapsule loading showed a healing efficiency of about 85%. The fluorescence emission from the damaged region was easily observed at a distance of 3 m. The self-healing protective coating is expected to be useful to confirm its self-healing function with the eye.