• 제목/요약/키워드: laboratory measurement methods

검색결과 440건 처리시간 0.029초

Effect of an Inpatient Rehabilitation Program for Recovery of Deconditioning in Hematologic Cancer Patients After Chemotherapy

  • Cha, Seungwoo;Kim, Inho;Lee, Shi-Uk;Seo, Kwan Sik
    • Annals of Rehabilitation Medicine
    • /
    • 제42권6호
    • /
    • pp.838-845
    • /
    • 2018
  • Objective To investigate the effect of a rehabilitation program in terms of De Morton Mobility Index (DEMMI) score, in hematologic cancer patients after chemotherapy. Methods Hematologic cancer patients admitted for chemotherapy were reviewed. They received a rehabilitation program during their hospital stay. DEMMI score measurement was performed, before and after rehabilitation. Demographics, diagnosis, chemotherapy information, rehabilitation program duration, mortality, body mass index (BMI), and laboratory test results were collected. For analysis, patients were classified according to diagnosis (multiple myeloma, leukemia, and others), mortality, and additional chemotherapy. Results There was statistically significant improvement in DEMMI score of 10.1 points (95% confidence interval, 5.9-14.3) after rehabilitation. It was more evident in the multiple myeloma group, and they revealed less mortality. When patients were divided according to mortality, survivors received the program earlier, and in a shorter period than in mortality cases. Although survivors revealed higher initial DEMMI score, improvement after rehabilitation did not differ significantly. Conclusion In hematologic cancer patients, rehabilitation program was effective for recovery from deconditioning, revealing significant increase in DEMMI score. Multiple myeloma patients may be good candidates for rehabilitation. Rehabilitation could be sustained during chemotherapy and for high-risk patients.

Seta Flash 밀폐식 장치를 이용한 n-Propanol+n-Hexanol계와 n-Butanol+n-Hexanol계의 인화점 측정 (Flash Point Measurement of n-Propanol+n-Hexanol and n-Butanol+n-Hexanol Systems Using Seta Flash Closed Cup Tester)

  • 하동명;이성진
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.34-39
    • /
    • 2019
  • Flash point is the important indicator to determine fire and explosion hazards of liquid solutions. In this study, flash points of n-propanol+n-hexanol and n-butanol+n-hexanol systems were obtained by Seta flash tester. The methods based on UNIFAC equation and multiple regression analysis were used to calculate flash point. The calculated flash point was compared with the experimental flash point. Absolute average errors of flash points calculated by UNIFAC equation are $2.9^{\circ}C$ and $0.6^{\circ}C$ for n-propanol+n-hexanol and n-butanol+n-hexanol, respectively. Absolute average errors of flash points calculated by multiple regression analysis are $0.5^{\circ}C$ and $0.2^{\circ}C$ for n-propanol+ n-hexanol and n-butanol+n-hexanol, respectively. As can be seen from AAE, the values calculated by multiple regression analysis are noticed to be better than the values by the method based on UNIFAC eauation.

The Effect of Protective Socks with Functional Insoles on Plantar Foot Pressure in Diabetes Patients

  • Kim, Hyun Soo;Jung, Do Young
    • The Journal of Korean Physical Therapy
    • /
    • 제30권6호
    • /
    • pp.224-228
    • /
    • 2018
  • Purpose: The most common cause of plantar ulceration is an excessive plantar pressure in patients with peripheral neuropathy. Foot orthosis and therapeutic footwear have been used to decrease the plantar pressure and prevent the plantar ulceration in in diabetes patients. We investigated whether protective sock with functional insoles reduce plantar pressure while walking in 17 diabetes patients. Methods: An in-shoe measurement device was used to measure the peak plantar pressure while walking. Peak plantar pressure data were collected while walking under two conditions: 1) wearing diabetic sock and 2) wearing the protective sock with functional insoles. Each subject walked 3 times in 10-m corridor under three conditions, and data were collected in 3 steps in the middle of corridor with in right and left feet, respectively. Pared t-test was used to compare the peak plantar pressures in three plantar areas under these two conditions. Results: The protective sock with functional insoles significantly reduced the peak plantar pressure on the lateral rearfoot, but significantly increased the peak plantar pressure on the middle forefoot, and medial midfoot (p<0.05). However, there were not significant in medial and lateral forefoot, lateral midfoot, and medial rearfoot between diabetic sock and the protective sock conditions (p>0.05). Conclusion: The protective sock with functional insoles reduced plantar pressures in the rearfoot and supported the medial longitudinal arch. However, it is necessary to change the position of metatarsal pad in the insole design of forefoot area to prevent diabetic foot ulceration.

Fast and Accurate Single Image Super-Resolution via Enhanced U-Net

  • Chang, Le;Zhang, Fan;Li, Biao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권4호
    • /
    • pp.1246-1262
    • /
    • 2021
  • Recent studies have demonstrated the strong ability of deep convolutional neural networks (CNNs) to significantly boost the performance in single image super-resolution (SISR). The key concern is how to efficiently recover and utilize diverse information frequencies across multiple network layers, which is crucial to satisfying super-resolution image reconstructions. Hence, previous work made great efforts to potently incorporate hierarchical frequencies through various sophisticated architectures. Nevertheless, economical SISR also requires a capable structure design to balance between restoration accuracy and computational complexity, which is still a challenge for existing techniques. In this paper, we tackle this problem by proposing a competent architecture called Enhanced U-Net Network (EUN), which can yield ready-to-use features in miscellaneous frequencies and combine them comprehensively. In particular, the proposed building block for EUN is enhanced from U-Net, which can extract abundant information via multiple skip concatenations. The network configuration allows the pipeline to propagate information from lower layers to higher ones. Meanwhile, the block itself is committed to growing quite deep in layers, which empowers different types of information to spring from a single block. Furthermore, due to its strong advantage in distilling effective information, promising results are guaranteed with comparatively fewer filters. Comprehensive experiments manifest our model can achieve favorable performance over that of state-of-the-art methods, especially in terms of computational efficiency.

치과 3D 프린팅용 광중합 시간에 따른 중합도 비교 (Comparison of polymerization by time of light curing for dental 3D printing)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제44권3호
    • /
    • pp.76-80
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the depth according to curing using photocurable resin for dental three-dimensional printing. Methods: A stainless mold with a height of 4 mm was prepared. Ultraviolet (UV) polymerization resin was injected into the mold. Photocuring was then performed for 5 minutes using a photopolymerizer, and the height was measured using a digital measuring instrument (first group). Second, light polymerization was also performed outside the mold for 5 minutes, and the height was measured using a digital measuring instrument. Third, light polymerization was further performed for 5 minutes, and the height was measured using a digital measuring instrument. Statistical analysis was performed with the Kruskal-Wallis test, which is a nonparametric test (α=0.05). Results: The third group had the largest measurement length, whereas the first group had the smallest. However, the difference between groups was not statistically significant (p>0.05). The color of the first group was different from that of the second and third groups. Conclusion: All of the 4-mm-thick photocured specimens had a curing reaction, but the part that was not directly irradiated with UV did not show its original color.

간단한 화학적 합성을 통한 고성능 슈퍼캐패시터용 수산화 구리 전극 (Facile Chemical Growth of Cu(OH)2 Thin Film Electrodes for High Performance Supercapacitors)

  • ;남민식;;전성찬
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.175-180
    • /
    • 2015
  • 본 연구에서는 간단한 화학적 합성 방법을 통하여 스테인레스 기판 위에 nano-bud 형태의 수산화 구리 박막을 형성하였다. 그리고 또 다른 합성 방법인 chemical bath deposition을 이용하여 수산화 구리 나노 구조를 간단하고 친환경적으로 형성하였다. 수산화 구리 박막의 구조적 연구는 X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM) 방법을 통하여 이루어졌으며 다결정의 nano-bud 형상을 확인할 수 있었다. 또한 나노 구조로 합성된 수산화구리 전극의 전기화학적 측정은 1M KOH의 전해질 조건에서 cyclic voltammetry (CV) and galvanostatic charge-discharge (GCD)에서 측정되었으며 $340Fg^{-1}$의 높은 비 용량을 보였다. 또한 $1mA\;cm^{-2}$ 의 전력 밀도에서 ${\sim}83Wh\;kg^{-1}$의 높은 에너지 밀도와 ${\sim}3.1kW\;kg^{-1}$의 높은 출력 밀도를 가지며 향상된 전극의 성능을 보였다. 이러한 뛰어난 의사 캐패시터의 성능은 수산화 구리의 nano-bud 형상에 의한 효과로 확인할 수 있었다. 본 연구를 통하여 화학적 합성 방법의 확장을 통하여 수산화 구리 전극의 에너지 저장 장치로써의 성능을 확인할 수 있었다.

식품 색소 Canthaxanthin의 HPLC 최적 분석법 확인 및 타당성과 측정불확도 평가 (Validation and Uncertainty Evaluation of an Optimized Analytical Method Using HPLC Applied to Canthaxanthin, a Food Colorant)

  • 서희재;김경수;홍미나;이찬
    • 한국식품영양과학회지
    • /
    • 제45권3호
    • /
    • pp.342-351
    • /
    • 2016
  • 본 연구는 한국에서 식용색소로 지정되지 않은 keto-carotenoid계의 canthaxanthin에 대한 최적 분석방법을 확보하기 위해 수행되었다. HPLC-UVD를 이용한 외국의 canthaxanthin 공인분석법을 검토하여 직선성, 분리능, 민감도, 검출한계(LOD), 정랑한계(LOQ)를 도출하고, 각 실험 데이터를 비교하여 최적의 canthaxanthin 분석방법을 확보하였다. 또한 확보된 최적 분석방법에 대한 정밀도, 정확도, 회수율, 실험실 간 교차검증, 측정불확도를 산출하여 canthaxanthin 최적 분석법에 대한 타당성을 검증하였다. AOAC법, 일본 및 영국의 공인분석법을 이용하여 canthaxanthin 표준용액을 5, 10, 20, 50, 100, $300{\mu}g/mL$의 6 point로 희석한 후 얻은 검량선의 상관계수는 모두 $R^2=0.999$ 이상으로 나타나 우수한 직선성을 보였으나 분리능, 민감도, LOD, LOQ는 일본의 공인분석법이 가장 우수하였다. 일본 공인분석법의 LOD와 LOQ는 각각 0.084 mg/kg, 0.254 mg/kg으로 나타났으며, 1보다 낮은 정밀도, 100%에 가까운 정확도, $100{\pm}10%$ 사이의 회수율, 교차검증 시 세 기관의 변동계수가 5이하로 나타나 canthaxanthin 분석을 위해 가장 최적화된 방법으로 확인되었다. 또한 측정하는 중에 나타나는 불확실성을 알아보기 위하여 canthaxanthin이 함유된 가공식품을 분석하여 측정불확도를 산출한 결과 $39.5{\pm}5.29mg/kg$(95% 신뢰구간, k=2.78)으로 나타났다. 확장불확도는 측정 농도의 13.4%로 나타나 유럽연합의 기준(16% 이하)에 적합한 결과를 보였다.

12.5 GHz 대역 위상 함수 특성 측정을 통한 RET 모델링 (RET Modelling through the Phase Function Measurement at 12.5 GHz)

  • 한일탁;배석희;정명원;백정기
    • 한국전자파학회논문지
    • /
    • 제18권3호
    • /
    • pp.334-340
    • /
    • 2007
  • 현재 ITU-R에서 제시하고 있는 RET(Radiative Energy Transfer)모델을 이용하여 수풀에 의한 손실을 예측을 하기 위해서는 6개의 입력 파라미터가 필요하다. 이중에서 수풀의 산란 특성과 관련된 4개의 파라미터를 도출하는 방법으로는 측정된 거리에 따른 수풀 손실 곡선과 RET모델의 피팅을 통해 도출하는 방법과 수풀 손실 및 추가의 위상 함수(phase function)측정을 통해서 도출하는 방법이 있다. 첫 번째 방법을 통해 RET 모델 파라미터를 도출하는 경우 피팅이 상당히 어렵고, 측정 결과로 얻은 수풀 손실 곡선에 따라 유일한 피팅 결과가 도출되지 않는 경우가 있으며, 도출된 파라미터의 물리적 의미도 결여되어 있다. 따라서 본 논문에서는 위상 함수 측정 방법과 위상 함수 측정을 통해 보다 정확하고 물리적인 타당성을 갖는 RET모델 파라미터를 도출하는 방법, 그리고 이를 이용하여 도출된 RET 모델 파라미터를 제시하였다. 본 논문에서 제시한 RET 모델링 방법, 측정 결과, 측정 결과로부터 도출한 RET 모델 파라미터는 2006년 ITU-R 회의에 기고서로 제출하여 ITU-R 보고서, 개정 권고서로 채택되었다.

자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가 (Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer)

  • 조용준;이소영;박해일;김영식;이제훈;김용구;한경자
    • Laboratory Medicine Online
    • /
    • 제2권1호
    • /
    • pp.10-14
    • /
    • 2012
  • 배경: HbA1c의 측정은 최근 6-8주간의 혈당조절을 평가하고 당뇨를 진단하기 위해 사용되고 있다. 최근 라텍스 면역비탁법을 사용하는 HbA1c 측정법이 개발되어 분석 능력과 임상검사실에서의 유용성을 평가하였다. 방법: 2009년 4월부터 7월까지 TBA-200FR에 Autolab HbA1c을 장착하여 CLSI guideline (EP5-A2, EP6-P, EP9-A2)에 따라 직선성, 정밀도, 상관성을 평가하였다. 결과: Autolab HbA1c는 고농도(15.1%)와 저농도(3.1%)의 검체의 혼합에서 r2=0.9997의 높은 직선성을 보였다. 12.1%의 경우 검사 일내 정밀도와 검사 일간 정밀도의 표준편차는 각각 0.06, 0.12였고 변이계수는 0.5%, 1.0%였다. 5.1%의 경우 각각 표준편차는 0.04, 0.09이었고 변이계수는 0.8%, 1.6%이었다. 비교식은 Autolab HbA1c=1.0859×HPLC-0.6957이었다. 결론: 본 연구에서 Autolab HbA1c는 Tosoh G7과 비교하여 좋은 수행능력을 보였다. 문헌고찰에서 변이형 혈색소에 따른 간섭은 없는 것으로 알려졌다. Tosoh G7에 비해 결과획득시간은 지연되는 단점이 있지만 Autolab HbA1c의 장점은 일반 화학분석기에 적용이 가능하고 검체의 전처리가 필요없으며 증류수를 사용하여 자동적으로 용혈과정이 이루어진다는 점이다.

중형과학로켓, KSR-II를 이용한 이온층 전자 밀도 및 온도 분포 측정에 관한 연구 (A STUDY OF THE IONOSPHERIC ELECTRON MEASUREMENT ON THE MEDIUM-SIZED SCIENTIFIC ROCKET , KSR-II)

  • 이재진;김준;이수진;민경욱;표유선;조광래;이황재
    • Journal of Astronomy and Space Sciences
    • /
    • 제15권2호
    • /
    • pp.401-415
    • /
    • 1998
  • 1998년 6월 11일 오전 10시(KST)에 태안 반도(37。N, 126。E)에서 발사된 국산 로켓 KSR-II는 73km에서 130km고도에 걸쳐 전자 밀도, 전자 온도, 부동 전위 등을 관측하는데 성공하였다. 이 지역은 이온 층의 E-region에 해당하는 지역으로 전자 온도가 낮고 특히 Probe의 오염 효과에 의해 오차가 생길 수 있기 때문에 전자 온도에 대한 정확한 데이터를 얻기가 쉽지 않다. 본 실험에서 사용된 장비는 Langmuir Probe (LP)와 Electron Temperature Probe (ETP)로 두 가지 서로 다른 probe를 통해 얻은 전자 온도를 비교하여 검증된 전자 온도를 구할 수 있었다. 실험 결과 전자 밀도는 약 90km지점에서 급격히 증가하여 약 102km지점에서 최대 전자 밀도를 갖고 이 이상의 고도에서는 점차 감소하는 것으로 나타났다. 이는 최대 전자밀도가 110km에서 나타나는 IRI(International Reference Ionosphere)95-model이나 PIM(Parameterized Ionospheric Model)과 비교해 보면 다소 낮은 고도에서 최대 전자 밀도가 존재하였음을 알 수 있으며 측정된 값은 모델 계산에 비해 약간 큰 값을 갖는 것으로 나타났다. 한편 ETP로 측정된 전자 온도는 200$^{\circ}$K에서 700$^{\circ}$K에서 LP에 의한 교란 효과로 추정되는 요동현상을 보였으며 이를 제외하면 전자 온도가 고도에 따라 다소 증가하는 경향을 볼 수 있었다. LP를 통해 구한 전자 온도는 125km이상의 고도에서 ETP를 통하여 구한 전자 온도와 어는 정도 일치한다는 점에서 신뢰할 만한 측정값을 얻었다고 판단된다.

  • PDF