• 제목/요약/키워드: laboratory measurement methods

검색결과 431건 처리시간 0.023초

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Journal of Audiology & Otology
    • /
    • 제24권2호
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • 대한청각학회지
    • /
    • 제24권2호
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Sweet Bee Venom 시술이 Rat의 호흡기계에 미치는 영향 (Effects of Sweet Bee Venom on the respiratory system in Rats)

  • 이종영;권기록
    • 대한약침학회지
    • /
    • 제14권3호
    • /
    • pp.47-53
    • /
    • 2011
  • Objectives: This study was performed to analyse the effects of Sweet Bee Venom(SBV-purified melittin supported by G&V Co., the major component of honey bee venom) on the respiratory system in rats. Methods: All experiments were conducted at Biotoxtech Company, a non-clinical studies authorized institution, under the regulations of Good Laboratory Practice(GLP). Male rats of 5 weeks old were chosen for this study and after confirming condition of rats was stable, SBV was administered in thigh muscle of rats in 0.175, 0.35 and 0.7 mg/kg dosage. And checked the effects of SBV on the respiratory system using the whole body plethysmography. And respiratory rate, tidal volume and minute volume of rats were checked after administered SBV (melittin). Results: 1. In the measurement of respiratory rate, there were not observed any significant differences compared with control group. 2. In the measurement of tidal volume, there was not observed any significant differences compared with control group. 3. In the measurement of minute volume, 0.35mg/kg dosage group showed significant differences compared with control group. But we estimated that this result was caused by individual differences. Conclusions: Above findings suggest that SBV seems to be safe treatment in the respiratory system of rats. And further studies on the subject should be conducted to yield more concrete evidences.

Analysis on Electric Field Based on Three Dimensional Atmospheric Electric Field Apparatus

  • Xing, Hong-yan;He, Gui-xian;Ji, Xin-yuan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1697-1704
    • /
    • 2018
  • As a key component of lighting location system (LLS) for lightning warning, the atmospheric electric field measuring is required to have high accuracy. The Conventional methods of the existent electric field measurement meter can only detect the vertical component of the atmospheric electric field, which cannot acquire the realistic electric field in the thunderstorm. This paper proposed a three dimensional (3D) electric field system for atmospheric electric field measurement, which is capable of three orthogonal directions in X, Y, Z, measuring. By analyzing the relationship between the electric field and the relative permittivity of ground surface, the permittivity is calculated, and an efficiency 3D measurement model is derived. On this basis, a three-dimensional electric field sensor and a permittivity sensor are adopted to detect the spatial electric field. Moreover, the elevation and azimuth of the detected target are calculated, which reveal the location information of the target. Experimental results show that the proposed 3D electric field meter has satisfactory sensitivity to the three components of electric field. Additionally, several observation results in the fair and thunderstorm weather have been presented.

Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone loss

  • Hangmiao Lyu;Li Xu;Huimin Ma;Jianxia Hou;Xiaoxia Wang;Yong Wang;Yijiao Zhao;Weiran Li;Xiaotong Li
    • 대한치과교정학회지
    • /
    • 제53권2호
    • /
    • pp.77-88
    • /
    • 2023
  • Objective: To develop a method for generating three-dimensional (3D) digital models of the periodontal ligament (PDL) using 3D cone-beam computed tomography (CBCT) reconstruction and to evaluate the accuracy and agreement of the 3D PDL models in the measurement of periodontal bone loss. Methods: CBCT data collected from four patients with skeletal Class III malocclusion prior to periodontal surgery were reconstructed at three voxel sizes (0.2 mm, 0.25 mm, and 0.3 mm), and 3D tooth and alveolar bone models were generated to obtain digital PDL models for the maxillary and mandibular anterior teeth. Linear measurements of the alveolar bone crest obtained during periodontal surgery were compared with the digital measurements for assessment of the accuracy of the digital models. The agreement and reliability of the digital PDL models were analyzed using intra- and interexaminer correlation coefficients and Bland-Altman plots. Results: Digital models of the maxillary and mandibular anterior teeth, PDL, and alveolar bone of the four patients were successfully established. Relative to the intraoperative measurements, linear measurements obtained from the 3D digital models were accurate, and there were no significant differences among different voxel sizes at different sites. High diagnostic coincidence rates were found for the maxillary anterior teeth. The digital models showed high intra- and interexaminer agreement. Conclusions: Digital PDL models generated by 3D CBCT reconstruction can provide accurate and useful information regarding the alveolar crest morphology and facilitate reproducible measurements. This could assist clinicians in the evaluation of periodontal prognosis and establishment of an appropriate orthodontic treatment plan.

흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교 (Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH)

  • 지현석;박용범;최재철;안창혁;유지훈;김재열;박인원;최병휘
    • Tuberculosis and Respiratory Diseases
    • /
    • 제48권5호
    • /
    • pp.773-780
    • /
    • 2000
  • 연구배경 : 흉수의 pH 측정은 흉막천자시 흉수의 원인 진단을 위해 시행되는 중요한 검사항목이며, 특히 부폐렴흉막염이 농흉화되는지를 확인할 수 있는 지표중 하나이다. 흉수의 pH 측정은 혈액가스분석기계를 이용하는 것이 표준이나, 상황에 따라서는 pH meter나 pH strip을 이용하기도 한다. 본 연구에서는 흉수중 삼출액을 대상으로 위의 세가지 방법으로 pH를 측정하고 측정치들을 비교하여 보았다. 방법 : 1999년 8월부터 2000년 3월까지 중앙대학교 부속 용산의료원에 입원하여 삼출성 흉수로 의심되어 흉막 천자를 시행한 34례 (결핵성 흉막염 16명, 부폐렴성 흉수 9명, 폐암 5명, 농흉 3명, 심부전 1명)의 흉수에서 혈액가스분석기계, pH meter, pH strip의 세 가지 방법으로 pH를 측정하였다. 혈액가스분석기계와 pH meter에 의한 측정은 천자후 $0^{circ}C$로 유지하면서 30분 내에 시행하였으며, pH strip 측정은 흉막천자 직후에 pH strip으로 pH를 측정하고, 상온 상태로 검사실에 내려서 보고되는 결과를 이용하였다. 결과 : 34례 흉수의 pH 값 (평균값$\pm$표준편차)은 혈액가스 분석법 7.34$\pm$0.12, pH meter 법 7.52$\pm$0.25, pH strip 법 중, 흉막천자후 즉시검사의 경우에는 7.37$\pm$0.16 였으며, 검사실에서 측정한 pH strip법은 6.93$\pm$0.20으로, 혈액가스분석법을 기준으로 한 평균치 분석에서 검사실에서 측정한 pH strip 법은 의미있는 차이를 보였다(p<0.05). 혈액가스분석법과 pH meter 방법, 그리고 혈액가스 분석법과 천자직후 pH strip법의 사이에는 의미있는 상관관계가 있었고, 혈액가스분석법과 pH strip 법 사이에는 의미있는 상관관계가 없었다. 결론 : 흉수천자 직후에 측정한 pH strip 법은 비교적 간단하고 정확하게 흉수의 pH를 측정할 수 있을 것으로 판단된다.

  • PDF

철도 소형구조물에서의 동상저감방안 연구 (The Study about Reduction of Frost-heaving in Railway Small Structures)

  • 한창용;이준석;조국환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1129-1135
    • /
    • 2011
  • Recently, In Korea region becoming subtropical climate, freezing index values have been increasing in winter. The climate condition in Korean became polarized. Since freezing index is increased recently, track heaving from frost is often occurred, which is ignored in past couple of years. Methods to prevent frost-heaving are circumfusion of calcium chloride and replacement of gravel ballast in usual. The effects of those methods are minimal, incontinuous, and not eco-friendly. Therefore, maintenances are performed repeatedly every year. This study discussed utilizing the waste-tire-chips and insulators in the small structures(bridge and box etc) for prevention of frost-heaving. In order to prove effect of waste-tire-chips, laboratory and field tests were conducted with CBR and measurement of frost-heaving amount to prove and verify effect of insulators.

  • PDF

비파괴시험기법을 이용한 토량환산계수 산정 방법 제시 (Estimation of Soil Volume Conversion Factors using Nondestructive Testing Methods)

  • ;류희환;조계춘;홍은수;진규남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.717-721
    • /
    • 2010
  • Soil volume conversion factors are used for estimation of an excavated the soil volume which will be removed or added in levelling the ground surface of a construction site. An accurate evaluation method will help us reduce a construction cost and time consuming. In this study, we performed the laboratory tests, including grain size measurement, water content, specific gravity, porosity, density and XRD tests, to suggest reliable soil volume conversion factors and weathering indices in field using nondestructive methods. The weathering index and soil volume conversion factor L are obtained for different types of soils. At results, the CIW index is the best method measuring the weathering index and the factor L is relative to natural porosity, void ratio, density and dry density.

  • PDF

Solid-Phase Extraction of Sulfamerazine from Shrimp Residue and Determination by Reversed Phase High Performance Liquid Chromatography

  • Jang, Won-Cheoul;Heo, Gang-Joon
    • Toxicological Research
    • /
    • 제12권2호
    • /
    • pp.163-169
    • /
    • 1996
  • The focus of this study was to investigate the suitable analytical methods for measurement of sulfamerazine and its metabolite in shrimp hepatopancreas and tail tissue, in addition to the methods for the optimization of solid-phase extraction cartridge conditions and the elucidation of sulfamerazine concentrations in aqueous buffer using HPLC with UV and EC detectors. Compared with UV detector the EC detector appears to be 10 times more sensitive than that of the UV detector. After the shrimp was exposed to 10 ppm sulfamerazine, the accumulation levels of sulfamerazine and its metabolite in tail tissue, which is edible portion, were considerably lower than 0.1 ppm. The data indicate that sulfamerazine continues to be a candidate for use at levels of sulfamerazine concentration used in aquaculture of shrimp.

  • PDF

Damage identification of belt conveyor support structure using periodic and isolated local vibration modes

  • Hornarbakhsh, Amin;Nagayama, Tomonori;Rana, Shohel;Tominaga, Tomonori;Hisazumi, Kazumasa;Kanno, Ryoichi
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.787-806
    • /
    • 2015
  • Due to corrosion, a large number of belt conveyors support structure in industrial plants have deteriorated. Severe corrosion may result in collapse of the structures. Therefore, practical and effective structural assessment techniques are needed. In this paper, damage identification methods based on two specific local vibration modes, named periodic and isolated local vibration modes, are proposed. The identification methods utilize the facts that support structures have many identical members repeated along the belt conveyor and there exist some local modes within a small frequency range where vibrations of these identical members are much larger than those of the other members. When one of these identical members is damaged, this member no longer vibrates in those modes. Instead, the member vibrates alone in an isolated mode with a lower frequency. A damage identification method based on frequencies comparison of these vibration modes and another method based on amplitude comparison of the periodic local vibration mode are explained. These methods do not require the baseline measurement records of undamaged structure. The methods is capable of detecting multiple damages simultaneously. The applicability of the methods is experimentally validated with a laboratory model and a real belt-conveyor support structure.