• Title/Summary/Keyword: laboratory measurement methods

Search Result 431, Processing Time 0.024 seconds

Feasibility of the Depth Camera-based Physical Health Monitoring System for Elderly Living Alone

  • Sungbae, Jo
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.106-112
    • /
    • 2024
  • Objective: This study aimed to evaluate the validity of a depth camera-based system for monitoring physical function, assessing its feasibility for accurately monitoring activities of daily living. Design: A cross-sectional study. Methods: Twenty-three participants were enlisted to perform fifteen activities of daily living within a living laboratory designed to simulate a home environment. Activities were monitored using a depth camera system capable of classifying actions into standing, sitting, and lying down, with a conventional video camera employed for activity recording. The duration of each activity, as measured by the system, was compared to direct observations made by a physical therapist which were analyzed using a motion analysis software. The association between these two measurement approaches was assessed through correlation analysis, coefficient of determination, intraclass correlation coefficient (ICC), and Bland-Altman plots. Results: Our findings indicated that standing activities exhibited the highest correlation (r=0.847) between the system measurements and physical therapist observations, followed by sitting (r=0.817) and lying down (r=0.734), which demonstrated lower correlations. However, the ICC and Bland-Altman plots revealed notable variances between the two measurement methods, particularly for activities involving lying down. Conclusions: In this study, the depth camera-based physical monitoring system showed promise feasibility in distinguishing standing, sitting, and lying down activities at home environments. However, the current study also underlined some necessities of enhancements in capturing lying down activities.

Analysis of PCI Cable Effects in HEMP Conducted Disturbance (HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석)

  • Jang, Tae-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.772-780
    • /
    • 2013
  • The high-altitude electromagnetic pulse(HEMP) conducted environment and the HEMP radiated environment are established as the consequences of a high-altitude nuclear explosion. The IEC 61000-2-10, the international standard, defines the HEMP conducted environment. The IEC 61000-5-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. The IEC 61000-4-24 deals with methods for testing protective devices for HEMP conducted disturbance. The IEC 61000-4-24:1997 mainly describes the measurement method of small protective components. However, it does not provide the measurement method for a combination filter of a protective component and a filter which is widely used in recent. It is important to consider the characteristic of the measurement setup parameters like thickness and length of the cable and its height above ground plane etc. in establishing measurement setup because HEMP conducted disturbances include the frequency spectrum below 50 MHz. This paper deals with the optimized measurement method, considering the frequency spectrum of HEMP conducted disturbance, current waveform, and analyzing the effects of cables existing in the measurement setup.

Standardization of Ice Mechanics Experimental Procedures in a Cold Room (Cold Room을 이용한 얼음 및 동토의 재료특성 계측 실험기법의 표준화)

  • Kim, Jung-Hyun;Choi, Kyung-Sik;Seo, Young-Kyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.2 s.75
    • /
    • pp.60-66
    • /
    • 2007
  • The first Korean cold room facility for ice mechanics experiments was assembled in 2004. Since then, the $4m{\times}6m$ cold room facility has been used, extensively under various environmental and loading conditions. After reviewing published references on cold room testing methods and also by trial and error, the standard procedures for testing and preparing laboratory ice material were established for the measurement of basic ice properties. In this paper, laboratory experimental techniques with the cold room facility and standard procedures established for ice material properties are introduced. Test specimens include laboratory-grown fresh water ice and frozen soils. Tests are carried out for unconfined compressive strength. Preparation and dimension of the specimen are the most important issues arising in cold room tests. The details of specimen preparation, testing procedure and strength test results are also discussed.

Review on innovative small refrigeration methods for sub-Kelvin cooling

  • Dohoon, Kwon;Junhyuk, Bae;Sangkwon, Jeong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.71-77
    • /
    • 2022
  • Sub-Kelvin cooling has been generally demanded for the fields of low temperature physics, such as physical property measurements, astronomical detection, and quantum computing. The refrigeration system with a small size can be appropriately introduced when the measurement system does not require a high cooling capacity at sub-Kelvin temperature. The dilution refrigerator which is a common method to reach sub-Kelvin, however, must possess a large 3He circulation equipment at room temperature. As alternatives, a sorption refrigerator and a magnetic refrigerator can be adopted for sub-Kelvin cooling. This paper describes those coolers which have been developed by various research groups. Furthermore, a cold-cycle dilution refrigerator of which the size of the 3He circulation system is minimized, is also introduced. Subsequently, a new concept of dilution refrigerator is proposed by our group. The suggested cooler can achieve sub-Kelvin temperature with a small size since it does not require any recuperator and turbo-molecular vacuum pump. Its architecture allows the compact configuration to reach sub-Kelvin temperature by integrating the sorption pump and the magnetic refrigerators. Therefore, it may be suitably utilized in the low temperature experiments requiring low cooling capacity.

Measurement of undesirable neutron spectrum in a 120 MeV linac

  • Yihong Yan ;Xinjian Tan;Xiufeng Weng ;Xiaodong Zhang ;Zhikai Zhang ;Weiqiang Sun ;Guang Hu ;Huasi Hu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3591-3598
    • /
    • 2023
  • Photoneutron background spectroscopy observations at linac are essential for directing accelerator shielding and subtracting background signals. Therefore, we constructed a Bonner Sphere Spectrometer (BSS) system based on an array of BF3 gas proportional counter tubes. Initially, the response of the BSS system was simulated using the MCNP5 code. Next, the response of the system was calibrated by using neutrons with energies of 2.86 MeV and 14.84 MeV. Then, the system was employed to measure the spectrum of the 241Am-Be neutron source, and the results were unfolded by using the Gravel and EM algorithms. Using the validated system, the undesirable neutron spectrum of the 120 MeV electron linac was finally measured and acquired. In addition, it is demonstrated that the equivalent undesirable neutron dose at a distance of 3.2 m from the linac is 19.7 mSv/h. The results measured by the above methods could provide guidance for linac-related research.

Utility of Pyloric Length Measurement for Detecting Severe Metabolic Alkalosis in Infants with Hypertrophic Pyloric Stenosis

  • Hyun Jin Kim
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.2
    • /
    • pp.88-94
    • /
    • 2024
  • Purpose: Infantile hypertrophic pyloric stenosis (IHPS) is a common gastrointestinal disease in neonates and hypochloremia metabolic alkalosis is a typical laboratory finding in affected patients. This study aimed to analyze the clinical characteristics of infants with IHPS and evaluate the association of clinical and laboratory parameters with ultrasonographic findings. Methods: Infants diagnosed with IHPS between January 2017 and July 2022 were retrospectively evaluated. Results: A total of 67 patients were included in the study. The mean age at diagnosis was 40.5±19.59 days, and the mean symptom duration was 11.97±9.91 days. The mean pyloric muscle thickness and pyloric canal length were 4.87±1.05 mm and 19.6±3.46 mm, respectively. Hyponatremia and metabolic alkalosis were observed in five (7.5%) and 36 (53.7%) patients, respectively. Serum sodium (p=0.011), potassium (p=0.023), and chloride levels (p=0.015) were significantly lower in patients with high bicarbonate levels (≥30 mmol/L). Furthermore, pyloric canal length was significantly higher in patients with high bicarbonate levels (p=0.015). To assess metabolic alkalosis in IHPS patients, the area under the receiver operating characteristic curve of pyloric canal length was 0.910 and the optimal cutoff value of the pyloric canal length was 23.5 mm. Conclusion: We found a close association between laboratory and ultrasonographic findings of IHPS. Clinicians should give special consideration to patients with pyloric lengths exceeding 23.5 mm and appropriate fluid rehydration should be given to these patients.

Real-Time Monitoring of Mitochondrial ATP Synthesis and Hydrolysis by Surface Infrared Spectroscopy

  • Yamaguchi, Ryo-Taro;Hirano-Iwata, Ayumi;Aonuma, Yuki;Yoshimura, Yuya;Shinohara, Yasuo;Kimura, Yasuo;Niwano, Michio
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.108-109
    • /
    • 2013
  • Mitochondria play key roles in the production of cell's energy. Their dominant function is the synthesis of adenosine 5'-triphosphate (ATP) from adenosine diphosphate (ADP) and phosphate (Pi) through the oxidative phosphorylation. Evaluation of drug-induced mitochondrial toxicity has become increasingly important since mitochondrial dysfunction has recently been implicated in numerous diseases including cancer and diabetes mellitus. Mitochondrial functions have been monitored via oxygen consumption, mitochondrial membrane potential, and more importantly via ATP synthesis since ATP synthesis is the most essential function of mitochondria. Various analytical methods have been employed to investigate ATP synthesis in mitochondria, including high performance liquid chromatography (HPLC), bioluminescence technique, and pH measurement. However, most of these methods are based on destructive analysis or indirect monitoring through the enzymatic reaction. Infrared absorption spectroscopy (IRAS) is one of the useful techniques for real-time, label-free, and direct monitoring of biological reactions [1,2]. However, the strong water absorption requires very short path length in the order of several micrometers. Transmission measurements with thin path length are not suitable for mitochondrial assays because solution handlings necessary for evaluating mitochondrial toxicity, such as rapid mixing of drugs and oxygen supply, are difficult in such a narrow space. On the other hand, IRAS in the multiple internal reflection (MIR) geometry provides an ideal optical configuration to combine solution handling and aqueous-phase measurement. We have recently reportedon a real-time monitoring of drug-induced necrotic and apoptotic cell death using MIR-IRAS [3,4]. Clear discrimination between viable and damaged cells has been demonstrated, showing a promise as a label-free and real-time detection for cell-based assays. In the present study, we have applied our MIR-IRAS system to mitochondria-based assays by monitoring ATP synthesis in isolated mitochondria from rat livers. Mitochondrial ATP synthesis and hydrolysis were in situ monitored with MIR-IRAS, while dissolved oxygen level and solution pH were simultaneously monitored with O2 and pH electrodes, respectively. It is demonstrated that ATP synthesis and hydrolysis can be monitored by the IR spectral changes in phosphate groups in adenine nucleotides and MIR-IRAS is useful for evaluating time-dependent drug effects of mitochondrial toxicants.

  • PDF

A Study on Field Application and Laboratory Performance Evaluation of Warm Mix Asphalt (중온아스팔트 혼합물의 현장 적용성 및 실내 공용성 평가)

  • Yang, Sung-Lin;Baek, Cheol-Min;Jeong, Kyu-Dong;Kim, Yeong-Min;Kim, Yong-Joo;Hwang, Sung-Do
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.9-18
    • /
    • 2012
  • PURPOSES : This study evaluated the field applicability and laboratory performance of warm-mix asphalt (WMA) as an alternative technology in asphalt pavement. METHODS : The pilot road using two different types of WMA mixture and one HMA mixture was constructed in Waegwan-Seokjeok road construction site and the mixtures were sampled at the asphalt plant for laboratory testings. The field applicability was assessed in environmental aspects, such as $CO_2$ emission, and in aspects of constructibility using the existing equipment and procedure, i.e., thickness and density measurement. The laboratory testings included the moisture susceptibility test by AASHTO T283, dynamic modulus test, triaxial repeated load permanent deformation test, and the fatigue test. RESULTS : The temperatures for production and compaction of WMA were $20{\sim}30^{\circ}C$ lower than those for HMA and therefore, the noxious gas emission were significantly reduced. The field density of WMA pavements was similar or better than that of HMA pavement. From the laboratory testings, it was found that WMA mixtures exhibit comparable performance to HMA mixture in moisture susceptibility, permanent deformation, and fatigue performance. CONCLUSIONS : With these results, it would be concluded that WMA could replace the existing HMA technology without any significant issue. To support this conclusion, it is necessary to track the long-term performance of WMA in pilot road.

Aberrant Expression of E-cadherin in Lung Tissues of Patients with Probable Lung Cancer

  • Yuan, Yu-Lin;Wang, Yu-Ming;Liu, Hua;Qin, Gui-Fang;Tang, Ai-Guo;Duan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.5149-5153
    • /
    • 2012
  • Introduction: This study assessed the relationship of E-cadherin mRNA and protein expression with the diagnosis of lung cancer with the aim of providing an auxiliary diagnostic method. Methods: Semi-quantitative nested RT-PCR and western blotting were applied to detect E-cadherin mRNA transcripts and protein, respectively, in 30 cases of diagnostic lung cancer, 30 cases of clinically suspected patients with lung cancer and 30 cases of other disease. Immunohistochemical staining was also used to detect E-cadherin. Results: Remarkably decreased levels of relative E-cadherin mRNA value and increased E-cadherin protein negativity were observed in probable lung cancer, when compared with possible lung cancer and others. With a threshold of 1.45, relative E-cadherin mRNA value showed a sensitivity of 90% and a specifity of 83% for the diagnosis of lung cancer. The combination of decreased relative E-cadherin mRNA value and negative E-cadherin protein increased the specificity and sensitivity. Conclusion: These data suggest that Chinese patients with diagnostic lung cancer have similar decreased levels of relative E-cadherin mRNA and E-cadherin protein value in the lung cancer tissues as in lung cancer patients in other countries. Measurement of relative E-cadherin mRNA and protein values in lung cancer tissues has potential for lung cancer diagnosis.

Stereo-digital image correlation in the behavior investigation of CFRP-steel composite members

  • Dai, Yun-Tong;Wang, Hai-Tao;Ge, Tian-Yuan;Wu, Gang;Wan, Jian-Xiao;Cao, Shuang-Yin;Yang, Fu-Jun;He, Xiao-Yuan
    • Steel and Composite Structures
    • /
    • v.23 no.6
    • /
    • pp.727-736
    • /
    • 2017
  • The application of carbon fiber reinforced polymer (CFRP) in steel structures primarily includes two categories, i.e., the bond-critical application and the contact-critical application. Debonding failure and buckling failure are the main failure modes for these two applications. Conventional electrometric techniques may not provide precise results because of the limitations associated with single-point contact measurements. A nondestructive full-field measurement technique is a valuable alternative to conventional methods. In this study, the digital image correlation (DIC) technique was adopted to investigate the bond behavior and buckling behavior of CFRP-steel composite members. The CFRP-to-steel bonded joint and the CFRP-strengthened square hollow section (SHS) steel column were tested to verify the suitability of the DIC technique. The stereo-DIC technique was utilized to measure continuous deformation. The bond-slip relationship of the CFRP-to-steel interface was derived using the DIC data. Additionally, a multi-camera DIC system consisting of four stereo-DIC subsystems was proposed and applied to the compressive test of CFRP-strengthened SHS steel column. The precise buckling location and CFRP delamination of the CFRP-strengthened SHS steel column were identified. The experimental results confirm that the stereo-DIC technique can provide effective measurements for investigating the behaviors of CFRP-steel composite members.