• Title/Summary/Keyword: laboratory and field tests

Search Result 738, Processing Time 0.032 seconds

Remote monitoring technique for geotechnical structures using acoustic emission (미소파괴음을 이용한 지반구조물 원격계측기술)

  • Cheon, Dae-Sung;Jung, Yong-Bok;Park, Eui-Seob;Park, Chan;Jang, Hyun-Ick
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.946-956
    • /
    • 2008
  • Acoustic emission(AE) is low-energy seismic event associated with a sudden inelastic deformation such as the sudden movement of existing fractures, the generation of new fractures or the propagation of fractures. These events rapidly increase before major failure and happen within a given rock volume and radiate detectable seismic waves. Rock slopes are usually large in scale and there are many discontinuities in rock mass. AE waves are strongly attenuated when they propagate through joints. Thus we should resolve the attenuation problem to monitor large volume. In this study, we developed waveguide which is composed of two different materials, cement mortar and stainless steel rod. And several laboratory tests on developed waveguide are performed to obtain generalized AE parameters to predict the failure stage in rock slope. Comparing field data with experimental data in laboratory tests, failure stage of rock slope can be evaluated. To verify and optimize the developed monitoring method, we are now carrying out the field application at a rock slope.

  • PDF

The Bearing Capacity Characteristics of Top Base Foundations in Cohesionless Soils (비점착성 지반상 팽이기초 적용에 따른 지지특성)

  • Kim, Chan-Kuk;Kim, Hak-Moon
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.135-145
    • /
    • 2010
  • Top Base Foundation (TBF) is widely used for the increment of bearing capacity and restraining settlement of foundations when the bearing capacity of ground is not enough. The design of bearing capacity obtained from exiting Japanese standard underestimates considerably what is compared with the observation values from the field measurement. Therefore, intensive model tests and site observation programs are carried out to establish more reasonable prediction technique and understanding of TBF in soft ground. In this study, 1/5 scale model tests are performed in order to investigate the behavior of TBF with various shapes in a laboratory. Also, about 100 sites measurement data are evaluated to investigate the field behavior of TBF in various ground conditions. Based on the results of the model tests and field measurement data, it was possible to introduce more reasonable bearing capacity equations of TBF considering N-value of soils, the effect of underground water and failure mechanisms.

Tests on explosion-resisting properties of high-performance equal-sized-aggregate concrete composite sandwich plates

  • Yizhong Tan;Songlin Yue;Gan Li;Chao Li;Yihao Cheng;Wei Dai;Bo Zhang
    • Structural Engineering and Mechanics
    • /
    • v.87 no.4
    • /
    • pp.297-304
    • /
    • 2023
  • Targeted introduction of explosion-resisting and energy-absorbing materials and optimization of explosion-resisting composite structural styles in underground engineering are the most important measures for modern engineering protection. They could also improve the survivability of underground engineering in wartime. In order to test explosion-resisting and energy-absorbing effects of high-performance equal-sized-aggregate (HPESA) concrete, the explosive loading tests were conducted on HPESA concrete composite plates by field simple explosion craters. Time-history curves of the explosion pressure at the interfaces were obtained under six conditions with different explosion ranges and different thicknesses of the HPESA concrete plate. Test results show that under the same explosion range, composite plate structures with different thicknesses of the HPESA concrete plate differ significantly in terms of the wave-absorbing ability. Under the three thicknesses in the tests, the wave-absorbing ability is enhanced with the growing thickness and the maximum pressure attenuation index reaches 83.4%. The energy attenuation coefficient of the HPESA concrete plate under different conditions was regressively fitted. The natural logarithm relations between the interlayer plate thickness and the energy attenuation coefficient under the two explosion ranges were attained.

Subsurface Contaminant Leak Detection System using Electrical Resistivity Measurement (전기비저항을 이용한 지반오염누출감지시스템 개발)

  • 박준범;오명학;이주형
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.11a
    • /
    • pp.42-71
    • /
    • 2001
  • Leakage detection system can possibly locate leak point without laboratory analysis. Several different types of sensors provide these benefits. But the use of these technologies is not widespread, mainly because of cost. Each of the leakage detection systems available has different advantages and disadvantages. The ideal system would be affordable, durable enough to last through the life of the landfill, automated, and applicable to all types of landfills. The laboratory tests were performed to investigate the relationship between electrical resistivity and the unsaturated subsurface condition and to evaluate the contamination due to leachate based on measuring electrical resistivity. The results of experiment show that the electrical resistivity of soil decreases as moisture density increases. The electrical resistivity of soil decreases as the concentration of leachate in pore fluid increases. These facts indicate that electrical resistivity method can be a promising tool in detecting of leachate. Also, the field model tests were conducted to verify that detection of leachate leak point on detection system using electrical characteristics is accurate. Field model test results of leakage detection system imply that the leakage detection system using electrical characteristics have the great potential of detecting exactly the leak point of leachate.

  • PDF

Comparison of retention characteristics of ferroelectric capacitors with $Pb(Zr, Ti)O_3$ films deposited by various methods for high-density non-volatile memory.

  • Sangmin Shin;Mirko Hofmann;Lee, Yong-Kyun;Koo, June-Mo;Cho, Choong-Rae;Lee, June-Key;Park, Youngsoo;Lee, Kyu-Mann;Song, Yoon-Jong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.3
    • /
    • pp.132-138
    • /
    • 2003
  • We investigated the polarization retention characteristics of ferroelectric capacitors with $Pb(Zr,Ti)O_3$ (PZT) thin films which were fabricated by different deposition methods. In thermally-accelerated retention tests, PZT films which were prepared by a chemical solution deposition (CSD) method showed rapid decay of retained polarization charges as the thickness of the films decreased down to 100 nm, while the films which were grown by metal organic chemical vapor deposition (MOCVD) retained relatively large non-volatile charges at the corresponding thickness. We concluded that in the CSD-grown films, the thicker interfacial passive layer compared with the MOCVD-grown films had an unfavorable effect on retention behavior. We observed the existence of such interfacial layers by extrapolation of the total capacitance with thickness of the films and the capacitance of these layers was larger in MOCVD-grown films than in CSD-grown films. Due to incomplete compensation of surface polarization charges by the free charges in the metal electrodes, the interfacial field activated the space charges inside the interfacial layers and deposited them at the boundary between the ferroelectric layer and the interfacial layer. Such space charges built up an internal field inside the films, which interfered with domain wall motion, so that retention property at last became degraded. We observed less imprint which was a result of less internal field in MOCVD-grown films while large imprint was observed in CSD-grown films.

Joint Stiffness Tests for Precast Concrete Pavement (프리캐스트 콘크리트 포장의 하중전달 성능 실험)

  • Yang, Sung-Chul;Kim, Seong-Min;Yoo, Tae-Seok;Han, Seung-Hwan
    • International Journal of Highway Engineering
    • /
    • v.10 no.2
    • /
    • pp.229-239
    • /
    • 2008
  • This paper compares the load transfer efficiency between precast concrete pavement specimen and typical concrete pavement specimen by means of laboratory and field tests. An experimental method was developed to evaluate the load transfer efficiency of the dowel bars buried in the concrete pocket and grouted with cement mortar. The test results showed that the load transfer efficiency of the specimen for the dowel bars repaired with grout was equivalent to that of the control specimen. In addition, a series of FWD field tests were conducted on the precast pavement to evaluate the joint stiffness. The field test results revealed that the central deflection of the precast slab slightly increased but the load transfer efficiencies at the joints were almost the same as those in the typical concrete pavement slab.

  • PDF

The Bearing Capacity of Top Base Foundations in Soft Ground (연약지반상 팽이기초 적용에 따른 지지특성)

  • Kim, Chan-Kuk;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.401-414
    • /
    • 2010
  • Top Base Foundation(TBF) is a stabilization method for light weight structures particularly in the soft ground. It is widely used for the increment of bearing capacity and restraining settlement of foundations when the bearing capacity of ground is not enough. However, when the design values from exiting Japanese standard are compared with the observation values from the field measurement, the bearing capacity of exiting standard estimated smaller For this reason, it is necessary to establish more reasonable prediction technique considering to understand the behavior of TBF in soft ground. In this study, 1/5 scale model tests were performed in the laboratory. Also, full scale tests were carried out in order to investigate the behavior of TBF with various shapes. In addition, about 100 sites measurement data were evaluated to investigate the behavior of TBF in various ground conditions. Based on the results of the model tests and field measurement data, it was possible to establish more reasonable the bearing capacity equation of TBF considering various N-value of soil, the effect of underground water and failure shapes.

  • PDF

Optimal mixing proportion of bottom-ash-based controlled low strength material for high fillability

  • Youngsu Lee;Taeyeon Kim;Bongjik Lee;Seongwon Hong
    • Geomechanics and Engineering
    • /
    • v.38 no.6
    • /
    • pp.541-551
    • /
    • 2024
  • Bottom ash classifies as a hazardous industrial-waste material that adversely affects human health. This study proposes its mixing with controlled low strength materials (CLSM) as a probable recycling approach. To this end, experiments have been performed to investigate the applicability of bottom-ash-based CLSM that comprises eco-friendly soil binders, water, fly ash, and a combination of bottom ash and weathered granite soil. The physical and chemical properties of the weathered granite soil, bottom ash, fly ash, and soil binders are analyzed via laboratory tests, including X-ray diffraction and scanning electron microscopy. To determine an appropriate CLSM mixing proportion, the flowability test is first performed on three mixture types having three replacement ratios of fly ash each. Subsequently, compressive-strength tests are performed. Based on the results of these tests, four mixtures are selected for the freeze-and-thaw test to determine the appropriate mixing proportion. Finally, the ground model and soil-contamination tests are performed to examine the field applicability of the mixture. This study confirms that bottom-ash-based CLSM causes negligible soil contamination, and it satisfies the prescribed performance requirements and contamination standards in Korea.

Evaluation of Field Compaction Density by Non-nuclear Density Gauge (다짐밀도 측정장비(Non-nuclear Type)를 사용한 현장 다짐밀도 평가)

  • Kim, Yeong Min;Im, Jeong Hyuk;Yang, Sung Lin;Kim, Ki Hyun;Hwang, Sung Do;Jeong, Kyu Dong
    • International Journal of Highway Engineering
    • /
    • v.17 no.1
    • /
    • pp.51-58
    • /
    • 2015
  • PURPOSES : The objective of this study is to compare the densities of asphalt pavements measured both in the field and in the laboratory, and also to evaluate the applicability of field density measuring equipment, such as the pavement quality indicator (PQI), by using statistical analysis. METHODS : For the statistical analysis of the density measured from asphalt pavement, student t-tests and a coefficient of correlation are investigated. In order to compare the measured densities, two test sections are prepared, with a base layer and an intermediate layer constructed. Each test section consists of 9 smaller sections. During construction, the field densities are measured for both layers (base and intermediate) in each section. Core samples are extracted from similar regions in each section, and moved to the laboratory for density measurements. All the measured densities from both the field and laboratory observations are analyzed using the selected statistical analysis methods. RESULTS AND CONCLUSION : Based on an analysis of measured densities, analysis using a correlation coefficient is found to be more accurate than analysis using a student t-test. The correlation coefficient (R) between the field density and the core density is found to be very low with a confidence interval less than 0.5. This may be the result of inappropriate calibration of the measuring equipment. Additionally, the correlation coefficient for the base layer is higher than for the intermediate layer. Finally, we observe that prior to using the density measuring equipment in the field, a calibration process should be performed to ensure the reliability of measured field densities.