• Title/Summary/Keyword: knee joint motion

Search Result 519, Processing Time 0.031 seconds

Knee-wearable Robot System Using EMG signals (근전도 신호를 이용한 무릎 착용 로봇시스템)

  • Cha, Kyung-Ho;Kang, Soo-Jung;Choi, Young-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.286-292
    • /
    • 2009
  • This paper proposes a knee-wearable robot system for assisting the muscle power of human knee by processing EMG (Electromyogram) signals. Although there are many muscles affecting the knee joint motion, the rectus femoris and biceps femoris among them play a core role in the extension and flexion motion, respectively, of the knee joint. The proposed knee-wearable robot system consists of three parts; the sensor for measuring and processing EMG signals, controller for estimating and applying the required knee torque, and actuator for driving the knee-wearable mechanism. Ultimately, we suggest the motion control method for knee-wearable robot system by processing the EMG signals of corresponding two muscles in this paper. Also, we show the effectiveness of the proposed knee-wearable robot system through the experimental results.

Effects of Landing Height and Knee Joint Muscle Fatigue on Movement of the Lower Extremity during Cutting After Landing (착지 높이와 무릎관절 근육 피로가 착지 후 방향 전환 동작 시 하지관절의 움직임에 미치는 영향)

  • Kim, You-Kyung;Youm, Chang-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.311-322
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the effects of landing height and knee joint muscle fatigue on the movement of the lower extremity during cutting after landing. Method : Subjects included 29 adults (age: $20.83{\pm}1.56years$, height: $172.42{\pm}9.51cm$, weight: $65.07{\pm}10.18kg$). The subjects were asked to stand on their dominant lower limb on jump stands that were 30 and 40 cm in height and jump from each stand to land with the dominant lower limb on a force plate making a side step cutting move at a $45^{\circ}$ angle with the non-dominant lower limb. The fatigue level at 30% of the knee extension peak torque using an isokinetic dynamometer. Results : The results showed that the difference of landing height increased maximum range of motion and angular velocity of hip, knee, and ankle joints in the sagittal plane, and in the angular velocity of motion of the hip joint in the sagittal plane. The maximum range of motion of the knee joint in the sagittal plane and the frontal plane decreased on landing from both heights after the fatigue exercise. The angular velocity of the hip joint in the sagittal plane, and the maximum range of motion of the hip joint in the transverse plane decreased for both landing heights after the fatigue exercise. The angular velocity of the hip joint in the frontal plane decreased for the 30 cm landing height after the fatigue exercise. On the other hand, the angular velocity and maximum range of motion of the ankle joint in the sagittal plane for both landing heights, and the angular velocity and maximum range of motion of the ankle joint in the frontal plane increased on landing from the 40 cm height after the fatigue exercise. Conclusion : Different landing heights of 30 and 40 cm and 30% fatigue of peak torque of knee extensor found a forefoot and stiff landing strategy, when cutting after landing. These results might be due to decline in the shock absorption capability of the knee joint and the movement capability related to cutting while increasing the contribution of the ankle joint, which may cause increased ankle joint injuries.

Development of Rehabilitation Medicine Device for Compound Joint Motion (복합관절 운동용 재활의료기기)

  • 정성훈;유범상;김남균;박상민;송문상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.704-708
    • /
    • 2004
  • The RMD(Rehabilitation Medicine Device) with CJM(Compound Joint Motion) is the lower limb unit muscular strengthening promotion rehabilitation medicine device for patients of joint orthopedic operation or the deficient elder of ability to walk, the handicapped. Since the products for the rehabilitation medicine device have limited to the simplicity linear motion, those do not give efficient the lower unit muscular strengthening effects. This device which was under the development gives to exercise of hip joint and knee joint with user's selection at once, get out of the simplicity linear motion. Also it will be contributed to a field of rehabilitation medicine and a mobility aid technology of the deficient elders of ability to walk, the handicapped.

  • PDF

The Study of 3D Motion Analysis on Lower Limb during Walking with Walker on Older People (노인의 워커 사용에 따른 보행 시 하지 관절 3차원 동작 분석에 관한 연구)

  • Kim, Seonchil;Lee, Sangyeol
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.1
    • /
    • pp.19-24
    • /
    • 2017
  • Purpose : The purpose of this study was to find out the difference motion of hip, knee and ankle joint during walking according to using walker on older people. Method : Korean older people of 34 subjects was participated in this study. Participants was measured joint motion on hip, knee and ankle joint during both conditions (walking with walker and without walker). The measured data were analyzed using independent t-test to investigate the difference of joint motion on the both condition. The statistical analyses were performed using Predictive Analytics Soft Ware (PASW) for windows(Ver. 19) and p-value less than .05 were considered significant for all cases. Result : The study showed that more joint motion on hip flexion and ankle pronation is increased by using walker. And hip extension, knee external rotation and ankle plantar flexion is decreased by using walker. Conclusion : This study suggest that using walker on older people was change the motion of the lower limb joint during walking. Therefore, It is necessary to develop a new walker that can reduce dependency and ensure stability on older people during walking.

Effect of Subtalar Joint Neutral Position and Knee Position on the Passive Ankle Dorsiflexion Range of Motion (목말밑 관절의 중립자세와 무릎관절 자세가 수동적인 발등굽힘 가동범위에 미치는 영향)

  • Jung, Do-young
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.23-31
    • /
    • 2019
  • Background: Measurement of passive ankle dorsiflexion range of motion (ADROM) is often part of a physical therapy assessment. Objects: The objective of this study was to identify the effects of subtalar joint neutral position (SJNP) on passive ADROM according to knee position in young adults. Methods: We recruited 14 young adult participants for this study. Two examiners used a universal goniometer to measure passive ADROM with and without SJNP. Dorsiflexion force was applied to the forefoot until maximum resistance was reached in two knee positions (extension and $90^{\circ}$ flexion) in the prone position. Subtalar joint position was also recorded at maximum ADROM. Passive ADROM was measured three times at different knee and subtalar joint positions, in random order. Two-way repeated-measures analysis of variance was used to compare the effects of subtalar joint and knee position on passive ADROM. Results: Passive ADROM was significantly lower with than without SJNP during both knee extension (mean difference: $7.4^{\circ}$) and $90^{\circ}$ flexion (mean difference: $16.9^{\circ}$) (p<.01). Passive ADROM was significantly higher during $90^{\circ}$ knee flexion than during knee extension both with (mean difference: $5.8^{\circ}$) and without SJNP (mean difference: $15.2^{\circ}$) (p<.01). The valgus position of the subtalar joint was significantly lower with than without SJNP during both knee extension (mean difference: $3.3^{\circ}$) and $90^{\circ}$ flexion (mean difference: $4.3^{\circ}$) (p<.01). Conclusion: Our results indicate that the gastrocnemius may limit ankle dorsiflexion more than the soleus does. Greater dorsiflexion at the subtalar and midtarsal joints was observed during passive ADROM measurement without than that with SJNP; therefore, SJNP should be maintained for accurate measurement of ADROM.

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

Clinical Characteristics of Hip Joint Rotations and Knee Adduction Moment through 3D Gait Analysis (3차원 보행분석을 통한 무릎 모음 모멘트와 고관절 내외회전의 임상적 특성)

  • Kim, Yongwook;Kang, Seungmook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.4
    • /
    • pp.41-48
    • /
    • 2017
  • Purpose : The purpose of this study was to verify the relationships among the knee adduction moment, hip rotation range, strength of hip rotators, and Foot Posture Index of healthy young adults. Method : Thirty-two healthy adults(24 male, 8 females) participated in this study. Subjects performed 5 walking trials to evaluate the knee adduction moments using a three-dimensional motion analysis system. Hip rotation ranges and hip rotator strengths were measured using a standard goniometer and a handheld dynamometer, respectively. The mean of three trials of clinical tests was used for data analysis. Results : The first peak knee adduction moment was significantly correlated with the hip rotation ranges and hip rotator strengths (P<.05). The second peak knee adduction moment was showed significant correlations with hip external rotation and rotation ratio. There were no correlations between Foot Posture Index and all knee adduction moments (P>.05). Conclusion : This study suggests that imbalances of the range of motion and strength of the internal and external rotation of the hip joint can affect knee adduction moments. The impact may exacerbate musculoskeletal disorders such as osteoarthritis of the knee. Therefore, further studies should be conducted to evaluate the effects of clinical interventions to correct these imbalances on the reduction of the knee adduction moments in patients with knee osteoarthritis.

A Case Study of a Female Patient with Patellofemoral Pain Syndrome for Effect of Hip Joint Traction and Hip Posterolateral Muscles Strengthening on Knee Pain, Range of Motion, and Lower Extremity Function Scale (슬개대퇴통증 증후군 환자에게 적용한 고관절 견인과 근력 강화 운동이 무릎 통증, 관절가동범위, 하지기능에 미치는 영향-사례 연구)

  • Hong, Hyun-Pyo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.35-38
    • /
    • 2014
  • Background: The case study examined the effect of a hip joint traction and hip posterolateral muscles strengthening on knee pain, range of motion, and lower extremity function scale of patients with patellofemoral pain syndrome (PFPS). Although PFPS has previously been attributed to quadriceps dysfunction, more recent research has linked this condition to impairment of the hip musculature and kinematic. Methods: Subject is a 27-years-old female with PFPS. Performed hip joint traction with belt and posterolateral muscles(hip abductors, external rotators) strengthening for 4 weeks, 3 times a week, once a day. Before and after the therapy, measurements were made on the visual analog scale (VAS) and of the ROM, and a lower extremity functional scale (LEFS) was conducted. Results: The results showed positive changes in VAS and range of motion and lower extremity functional scale. First VAS of knee changed from 6 to 2. Second hip joint range of motion showed that internal rotation recored from $53^{\circ}$ to $58^{\circ}$ and external rotation recorded from $32^{\circ}$ to $37^{\circ}$. Third The lower extremity functional scale showed before therapy of 44; after therapy, 63. Conclusion: The hip joint traction and hip posterolateral muscles strengthening was effective in alleviating knee pain, increasing ROM and Lower extremity functional scale of the PFPS patients.

Effect of Taping Technique Applied to Adults with Knee Instability on Landing Error Scoring System, Lower Extremity Joint Angle

  • Son, Jin-Kyu;Park, Sam-Ho;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.406-413
    • /
    • 2021
  • Objective: The purpose of this study was to investigate effects of taping technique applied to knee instability. Design: Cross sectional study. Methods: Twenty-six participants with knee instabilityparticipated in this study. They were randomly assigned to the Kinesio taping (KT) group (n=13) and the dynamic taping (DT) group (n=13). Both groups applied knee stabilization taping techniques. In order to compare the effects of each taping technique, the change in the landing error scoring system (LESS) and lower extremity joint angle wasrecorded before and after the intervention. Results: Both groups significantly decreased in the change before and after the LESS (p<0.05). At the joint angle of the lower extremities, KT group significantly reduced the valgus angle at the max knee flexion (p<0.05). In DT group knee joint flexion and hip joint flexion angles were significantly increased at foot contact (p<0.05). In max knee flexion, the knee joint flexion angle was significantly increased (p<0.05). In foot contact, max knee flexion, the knee joint valgus angle was significantly increased (p<0.05). DT group showed more significant changes in knee joint flexion angle at foot contact and hip joint flexion angle at max knee flexion. Conclusions: Dynamic taping is a clinically applicable intervention method for lowering the risk of non-contact injury in participants with knee instability and for knee stability during rehabilitation exercises.

Development of a Modified Exoskeletal Linkage Type Instrument for 3-D Motion Measurement of the Human Knee Joint (무릎관절의 3차원 회전량 측정을 위한 개선된 외골격 링크장치 형태의 측정기구 개발)

  • 김영은;안정호
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.289-294
    • /
    • 1994
  • A new type of electrogoniometer to measure the three dimensional motion of the human knee joint was developed. This instrument is composed of six potentiometers: four arranged for two universal joints, one for pin joint, and one for axial rotation measurement. The voltage change in six potentiometers were collected through A/D converter for acquisition, storage and analysis. With a developed instrument, gait analysis was performed. Compared to earlier developed triaxial type goniometer, new instrument shows its convenience in application and accuracy in measurement.

  • PDF