• 제목/요약/키워드: kappa values

검색결과 262건 처리시간 0.025초

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

Estimation of Growth Curve Parameters for Body Weight and Length in Miniature Pigs

  • Kang, Hyun Sung;Nam, Ki Chang;Cabling, Meriam M.;Lee, Myeong Seop;Choi, Te Jung;Yoon, Jong Taek;Seo, Kang Seok
    • Journal of Animal Science and Technology
    • /
    • 제54권6호
    • /
    • pp.395-400
    • /
    • 2012
  • This study was conducted to estimate the growth curve parameters for the body weight (BW) and body length (BL) of miniature pigs in Korea. Growth curve parameters were estimated through a nonlinear regression model using Gompertz, Logistic, and von Bertalanffy methods. A total of 25 piglets were measured monthly from birth up to 15 months of age to estimate both body weight and length. Results showed that the estimated average values for the body weight (body length) were 31.83 kg (58.77 cm) for the mature weight (A), 3.06 (1.74) for the growth ratio (${\beta}$), and 0.28 (0.52) for the maturing rate (${\kappa}$). Average inflection points showing maximum growth rate estimated each month for body weight were 3.97 kg and 11.70 cm, while for the body length were 1.06 kg and 21.61 cm. Moreover, the estimated maturation rates of the body weight and length for the group of Sire 1 were 0.22 and 0.40 respectively, whereas for the group of Sire 2 these values were 0.34 and 0.39. On the other hand, for the groups of Dam 1, Dam 2, and Dam 3, maturation rates for their body weights were 0.26, 0.28 and 0.33 respectively, while for their body lengths these values were 0.43, 0.37, and 0.38, respectively. The study also indicated a negative relationship between the values of mature weight and maturity rate for the body weight will result to a higher inflection point which is in contrast for the body length where results show that a positive relationship between the values of mature length and the maturity rate will result to a higher inflection point. Furthermore, the growth performance of miniature pig varies across stages but using these estimated growth curve parameters could improve the genetic traits of miniature pig.

영양부족 환자의 조기발견을 위한 선별검사의 적용 및 효용성 평가 (Application and Efficacy Evaluation of Nutritional Screening Tool)

  • 남궁환
    • 한국건강관리협회지
    • /
    • 제4권1호
    • /
    • pp.1-11
    • /
    • 2006
  • "본 논문은 대한외과학회지 2006년 제70권제1호에 실렸던 논문으로 대한외과학회 편집위원회 승인을 득하고 본 협회지에 게재함. Purpose: Malnutrition has been frequently reported for patients on their admission to the hospital and it has been associated with an increase in morbidity, mortality and the length of the hospital stay. Although a number of screening tools have been developed to identify those patients at risk for malnutrition, there is no' gold standard' for defining malnutrition and the malnourished patients remain largely unrecognized. The aim of this study is to evaluate the efficacy of a nutritional screening tool for use in Dankook University Hospital. Methods Nutritional evaluation was performed for 53 patients who were admitted to the department of surgery and internal medicine between October and December 2004. The screening tool was completed by the ward nurse and the nutritional support team nurse on the same patients within24 hours of admission. The nutritional support team nurse performed the full assessment. The screening sheet included 4 questions regarding body mass index, recent unintentional weight loss, food intake and disease severity. Each answer was scored and a total of 5 was tested as the criterion fey malnutrition. The full assessment included current body weight, recent weight loss, triceps skinfold thickness, mid-arm muscle circumference, serum albumin)in and total lymphocyte count. Malnutrition was defined by 3 or more values below the reference values. The reliability of the screening tool was assessed using kappa statistic. Sensitivity, specificity and accuracy were calculated to evaluate the validity of the screening tool. The receiver operating characteristic(ROC) curve was drawn to choose a cutoff valve that maximizes sensitivity and specificity. Results' The level of agreement between the ward nurse and the NST nurse was good for BMI and food intake and moderate for weight loss and disease severity. The full assessment identified7 patients(13.2%) as malnourished. The screening sheet had a sensitivity of 86% and a specificity of 80%. According to the ROC curve, a score of 5 points provided the best validity. Conclusion The nutritional screening tool is reliable when completed by different observers and it is valid for nutritional assessment.

  • PDF

MODIS 다중시기 영상을 이용한 북한 다락밭 분류 (Terrace Fields Classification in North Korea Using MODIS Multi-temporal Image Data)

  • 정승규;박종훈;박종화;이동근
    • 한국환경복원기술학회지
    • /
    • 제19권1호
    • /
    • pp.73-83
    • /
    • 2016
  • Forest degradation reduces ecosystem services provided by forest and could lead to change in composition of species. In North Korea, there has been significant forest degradation due to conversion of forest into terrace fields for food production and cut-down of forest for fuel woods. This study analyzed the phenological changes in North Korea, in terms of vegetation and moisture in soil and vegetation, from March to Octorber 2013, using MODIS (MODerate resolution Imaging Spectroradiometer) images and indexes including NDVI (Normalized Difference Vegetation Index), NDSI (Normalized Difference Soil Index), and NDWI (Normalized Difference Water Index). In addition, marginal farmland was derived using elevation data. Lastly, degraded terrace fields of 16 degree was analyzed using NDVI, NDSI, and NDWI indexes, and marginal farmland characteristics with slope variable. The accuracy value of land cover classification, which shows the difference between the observation and analyzed value, was 84.9% and Kappa value was 0.82. The highest accuracy value was from agricultural (paddy, field) and forest area. Terrace fields were easily identified using slope data form agricultural field. Use of NDVI, NDSI, and NDWI is more effective in distinguishing deforested terrace field from agricultural area. NDVI only shows vegetation difference whereas NDSI classifies soil moisture values and NDWI classifies abandoned agricultural fields based on moisture values. The method used in this study allowed more effective identification of deforested terrace fields, which visually illustrates forest degradation problem in North Korea.

Intra-Rater Test-Retest Reliability of Ely's Test Using Smartphone in Patients With Lumbar Extension-Rotation Syndrome

  • Park, Kyue-Nam;Ha, Sung-Min;Chung, Sung-Dae;Kim, Si-Hyun;Jang, Jun-Hyeok
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.46-54
    • /
    • 2012
  • Ely's test is commonly used to assess rectus femoris muscle flexibility. however, a reliability limit of this test was demonstrated by a previous study. In this study, we present an alternative method using an application for a digital horizontal level in a smartphone (DHLS) to complement the reliability limit of Ely's test. The aim of this study was to examine the reliability of Ely's test using DHLS on the pelvis, compared to using visual observation (VO) of pelvic and hip motions. Nineteen patients with lumbar extension-rotation syndrome were recruited for this study. An examiner examined the rectus femoris flexibility (both pass/fail and goniometer scoring) through Ely's test using both DHLS and VO. A retest session was completed two hours later for within-day reliability and seven days later for between-day intra-rater test-retest reliability. Results showed higher Kappa values for pass/fail scoring and higher intraclass correlation coefficient values for goniometer scoring in Ely's test using DHLS, compared to using VO. Measurement error and Bland and Altman plots further demonstrated the degree of intra-rater variance during Ely's test using DHLS in a clinical setting, compared to using VO. These results demonstrated that Ely's test using DHLS showed acceptable reliability compared to using VO. Ely's test using DHLS could be widely used for measuring the rectus femoris muscle flexibility in patients with lumbar extension-rotation syndrome, although the inter-rater reliability needs to be established first.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).

Development and Validation of Computerized Semiquantitative Food Frequency Questionnaire for Koreans with High-Risk of Hypercholesterolemia

  • Kim, Hyung-Sook;Lee, Kyoungsin;Park, Haymie
    • Journal of Community Nutrition
    • /
    • 제6권1호
    • /
    • pp.35-41
    • /
    • 2004
  • Cardiovascular disease has the highest mortality rate in South Korea. Previous studies have reported that serum cholesterol level relates to intake of dietary fat and cholesterol. Therefore, in this study we developed a semiquantitative food frequency questionnaire (FFQ) for Koreans with a high-risk of hypercholesterolemia and to validate the FFQ. Semiquantitative FFQ, which includes 160 food items, reflects intakes of energy, fat, saturated fatty acid (SFA), monounsaturated fatty acid (MUPA), polyunsaturated fatty acid (PUPA) and cholesterol. We chose food items from the previous study of our research group (Suh 1999) which reported a nutritional status of Korean adults with normocholesterolemia, borderline and hypercholesterolemia. To validate the FFQ, we compared the results of the FFQ with those of a 3-day food record using a paired t-test. In addition, we calculated Pearson's and Spearmen's correlation coefficients. Intakes assessed by the FFQ and a 3-day food record were classified into quartile and the degree of agreement was obtained. Fifty-five participants responded for the validation study by completing both the FFQ and a 3-day food record. Pearson's correlation coefficients between estimated intakes by respective methods for energy, fat, SF A, MUPA, PUPA and cholesterol were 0.32,0.41,0.37,0.41,0.37 and 0.21, respectively. Spearman's correlation coefficients of energy, fat, SF A, MUPA, PUPA, cholesterol were 0.31, 0.44, 0.39, 0.46, 0.46, and 0.37, respectively. Nutrient densities in 1000kcal were compared. Pearson's correlation coefficient of cholesterol density increased and other values were similar with original values. The average degree of agreement was 67% that intakes of energy, fat, SF A, MUPA, PUPA and cholesterol assessed by the FFQ and 3-day food records were classified within the same and the adjacent quartile. On the average, 8% were misclassified into the extreme opposite quartile. The average of weighted kappa was 0.46. In conclusion, the FFQ developed in this study is considered to be a reliable tool to assess nutrient intakes for Koreans with a risk of hypercholesterolemia because the FFQ reflects the intakes of energy, fat, SFA, MUFA, PUPA, and cholesterol.

구름방울 활성화 과정 모수화 방법에 따른 구름 형성의 민감도 실험 (Sensitivity Test of the Parameterization Methods of Cloud Droplet Activation Process in Model Simulation of Cloud Formation)

  • 김아현;염성수;장동영
    • 대기
    • /
    • 제28권2호
    • /
    • pp.211-222
    • /
    • 2018
  • Cloud droplet activation process is well described by $K{\ddot{o}}hler$ theory and several parameterizations based on $K{\ddot{o}}hler$ theory are used in a wide range of models to represent this process. Here, we test the two different method of calculating the solute effect in the $K{\ddot{o}}hler$ equation, i.e., osmotic coefficient method (OSM) and ${\kappa}-K{\ddot{o}}hler$ method (KK). To do that, each method is implemented in the cloud droplet activation parameterization module of WRF-CHEM (Weather Research and Forecasting model coupled with Chemistry) model. It is assumed that aerosols are composed of five major components (i.e., sulfate, organic matter, black carbon, mineral dust, and sea salt). Both methods calculate similar representative hygroscopicity parameter values of 0.2~0.3 over the land, and 0.6~0.7 over the ocean, which are close to estimated values in previous studies. Simulated precipitation, and meteorological variables (i.e., specific heat and temperature) show good agreement with reanalysis. Spatial patterns of precipitation and liquid water path from model results and satellite data show similarity in general, but on regional scale spatial patterns and intensity show some discrepancy. However, meteorological variables, precipitation, and liquid water path do not show significant differences between OSM and KK simulations. So we suggest that the relatively simple KK method can be a good alternative to the OSM method that requires various information of density, molecular weight and dissociation number of each individual species in calculating the solute effect.

임플란트 직경이 골유착에 미치는 영향에 관한 연구 (INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS)

  • 이준호;신상완;권상호
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

대체당 첨가 고령자용 포도젤리의 품질 특성 (Quality Characteristics of Grape Jellies with Sugar Derivative Sweeteners for the Elderly)

  • 이미혜;최은정;오명숙
    • 한국식생활문화학회지
    • /
    • 제23권4호
    • /
    • pp.499-506
    • /
    • 2008
  • This study was conducted to determine the quality characteristics of grape jellies for the elderly. The jellies contained sugar (control) or sugar derivative sweeteners (erythritol, isomaltooligosaccharide, sorbitol, and xylitol). Agar (0.31%) and $\kappa$-carrageenan (0.27%) were the gelling agents. The average age of the subjects participating in the acceptance test was 79. The lightness (L), redness (a), and yellowness (b) values of the agar gel with erythritol mostly decreased, indicating a darker and pale red color. The L and b values of the carrageenan gel with sugar derivative sweeteners increased, indicating brighter and yellowish color. The agar and carrageenan gels with sorbitol showed higher gelling and melting temperature, indicating that gelation occurred easily and did not easily melt. The agar and carrageenan gels with xylitol showed a low-melting temperature, indicating low stability with temperature change. The break-down rate of the agar and carrageenan gels with erythritol was low, whereas that of agar gel with sorbitol was relatively high despite its high melting temperature. Hardness, cohesiveness, gumminess, and chewiness of the gels with sugar derivative sweeteners decreased, and this tendency was most distinct with isomaltooligosaccharide in the agar gel and with sorbitol in the carrageenan gel. The rupture properties of the gel were the same as the hardness of the gel. Sensory acceptance of the agar gels with erythritol, sorbitol, isomaltooligosaccharide, and the carrageenan gel with erythritol was fairly high, whereas that of the agar gel with xylitol and the carrageenan gel with isomaltooligosaccharide and xylitol was low. The results show that sorbitol and erythritol are appropriate as sugar substitutes in grape jellies for the elderly about the acceptability and stability of the gels.