• 제목/요약/키워드: kappa values

검색결과 262건 처리시간 0.025초

Flavonoids Differentially Modulate Nitric Oxide Production Pathways in Lipopolysaccharide-Activated RAW264.7 Cells

  • Kim Ae Ra;Cho Jae Youl;Zou Yani;Choi Jae Sue;Chung Hae Young
    • Archives of Pharmacal Research
    • /
    • 제28권3호
    • /
    • pp.297-304
    • /
    • 2005
  • Naturally occurring flavonoids are known to modulate various inflammatory and immune processes. Based on structural property, in this study, molecular mechanism of flavonoids in modulating nitric oxide (NO) production and its signaling pathway were investigated using lipopolysaccharide (LPS)-activated RAW264.7 cells. Although flavonol-typed flavonoids (kaempferol and quercetin) more potently scavenged reactivity of nitric oxide ($\cdot$NO) as well as peroxynitrite (ONOO$\kappa$) than isoflavones (genistein and genistin), kaempferol, quercetin and genistein showed a little difference in inhibition of both inducible NO synthase expression and NO production, with IC$_{50}$ values of 13.9, 20.1 and 26.8 $\mu$M. However, there was a striking pattern related to structural feature in modulation of LPS-mediated signaling pathways. Thus, flavonols only inhibited transcription factor AP-1 activation, whereas isoflavones suppressed the DNA binding activation of NF-$\kappa$B and C/EBP$\beta$. Therefore, these data suggest that structural feature may be linked to decide drugs target molecule in LPS-mediated signaling pathways, rather than its potency.

Neonatal Intracranial Ischemia and Hemorrhage : Role of Cranial Sonography and CT Scanning

  • Khan, Imran Ahmad;Wahab, Shagufta;Khan, Rizwan Ahmad;Ullah, Kkram;Ali, Manazir
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권2호
    • /
    • pp.89-94
    • /
    • 2010
  • Objective : To evaluate the role of cranial sonography and computed tomography in the diagnosis of neonatal intracranial hemorrhage and hypoxic-ischemic injury in an Indian set-up. Methods : The study included 100 neonates who underwent cranial sonography and computed tomography (CT) in the first month of life for suspected intracranial ischemia and hemorrhage. Two observers rated the images for possible intracranial lesions and a kappa statistic for interobserver agreement was calculated. Results : There was no significant difference in the kappa values of CT and ultrasonography (USG) for the diagnosis of germinal matrix hemorrhage/intraventricular hemorrhage (GMH/IVH) and periventricular leucomalacia (PVL) and both showed good interobserver agreement. USG, however detected more cases of GMH/IVH (24 cases) and PVL (19) cases than CT (22 cases and 16 cases of IVH and PVL, respectively). CT had significantly better interobserver agreement for the diagnosis of hypoxic ischemic injury (HII) in term infants and also detected more cases (33) as compared to USG (18). CT also detected 6 cases of extraaxial hemorrhages as compared to 1 detected by USG. Conclusion : USG is better modality for imaging preterm neonates with suspected IVH or PVL. However, USG is unreliable in the imaging of term newborns with suspected HII where CT or magnetic resonance image scan is a better modality.

Object-oriented Classification and QuickBird Multi-spectral Imagery in Forest Density Mapping

  • Jayakumar, S.;Ramachandran, A.;Lee, Jung-Bin;Heo, Joon
    • 대한원격탐사학회지
    • /
    • 제23권3호
    • /
    • pp.153-160
    • /
    • 2007
  • Forest cover density studies using high resolution satellite data and object oriented classification are limited in India. This article focuses on the potential use of QuickBird satellite data and object oriented classification in forest density mapping. In this study, the high-resolution satellite data was classified based on NDVI/pixel based and object oriented classification methods and results were compared. The QuickBird satellite data was found to be suitable in forest density mapping. Object oriented classification was superior than the NDVI/pixel based classification. The Object oriented classification method classified all the density classes of forest (dense, open, degraded and bare soil) with higher producer and user accuracies and with more kappa statistics value compared to pixel based method. The overall classification accuracy and Kappa statistics values of the object oriented classification were 83.33% and 0.77 respectively, which were higher than the pixel based classification (68%, 0.56 respectively). According to the Z statistics, the results of these two classifications were significantly different at 95% confidence level.

회상법, 기록법 및 식품섭취빈도조사법을 이용한 노인의 영양소 섭취 수준의 비교 (Comparison of Dietary Intakes by 24-hr Dietary Recall, Dietary Record and Food Frequency Questionnaire among Elderly People)

  • 최미숙;한경희;박기순
    • Journal of Nutrition and Health
    • /
    • 제34권6호
    • /
    • pp.688-700
    • /
    • 2001
  • Nutrient intakes estimated using a 24-hr recall, a dirt record and a food frequency questionnaire(FFQ) were compared in a group of ninety-four elderly people(21 males, 73 females) in Cheongju, a city in Chung-Buk province. Mean intakes for energy, protein, Ca, p, Na, K thiamin and niacin obtained from the diet record were higher than those from the 24-hr recall. Mean intakes for energy, protein, Ca, P, Na, K thiamin, niacin and vitamin C from the FFQ were higher than those obtained from the 24-hr recall or the diet record. Correlation coefficients between the nutrient intake values from the 24-hr recall and those from the diet record ranged from 0.84 to 0.95 and were significantly correlated(p < 0.001). About 80% of the subjects in the lowest quintile by the 24-hr recall were also in the lowest two quintiles by the diet record. While the percentage fallen into the opposite category ranged from 0% to 15%. For most nutrients, at least 65% of the subjects when classified by the 24-hr recall fell into the same quintile when classified by the diet record, and the mean kappa value was 0.7. About 52% of the subjects in the lowest category by the 24-hr recall fell into the lowest two categories by FFQ. The mean percentage of the subjects in the lowest quintile by the diet record or in the lowest two quintiles by the FFQ was 51%. For most nutrients, at least 24% of each of the subjects when classified by both the 24-hr recall and the diet record fell into the same category when classified by the FFQ. The kappa values between the 24-hr recall or the diet recall and the FFQ were 0.17. These data indicate that in elderly subjects the 24-hr recall can provide very similar information to that obtained from the diet record but the FFQ can not provide good information if the right FFQ method is not used for only elderly subjects.

  • PDF

Validity of Self-Reported Height, Weight, and Body Mass Index of the Korea Youth Risk Behavior Web-Based Survey Questionnaire

  • Bae, Ji-Suk;Joung, Hyo-Jee;Kim, Jong-Yeon;Kwon, Kyoung-Nam;Kim, Yoon-Jung;Park, Soon-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • 제43권5호
    • /
    • pp.396-402
    • /
    • 2010
  • Objectives: Self-reported anthropometric values, such as height and weight, are used to calculate body mass index (BMI) and assess the prevalence of obesity among adolescents. The aim of this study was to evaluate the validity of selfreported height, weight, and BMI of the Korea Youth Risk Behavior Web-based Survey questionnaire. Methods: A convenience sample of 137 middle school students and 242 high school students completed a selfadministered questionnaire in 2008. Body height and weight were directly measured after self-reported values were obtained from the questionnaire survey. Sensitivity, specificity, and kappa statistics were computed in order to evaluate the validity of the prevalence of obesity (BMI $\geq$ 95th percentile or $\geq$ $25;kg/$m^2$) based on self-reported data. Results: Self-reported weight and BMI tended to be underestimated. Self-reported height tended to be overestimated among middle school females and high school males. Obese adolescents tended to underestimate their weight and BMI and overestimate their height more than non-obese adolescents. The prevalence estimate of obesity based on selfreported data (10.6%) was lower than that based on directly measured data (15.3%). The estimated sensitivity of obesity based on self-reported data was 69.0% and the specificity was 100.0%. The value of kappa was 0.79 (95% confidence interval, 0.70 - 0.88). Conclusions: This study demonstrated that self-reported height and weight may lead to the underestimation of BMI and consequently the prevalence of obesity. These biases should be taken into account when self-reported data are used for monitoring the prevalence and trends of obesity among adolescents nationwide.

박리-재부착 이후의 재발달 난류경계층 II -난류 모델들에 관한 고찰- (Redeveloping Turbelent Boundary Layer after Separation-Reattachment(II) -A Consideration on Turbulence Models-)

  • 백세진;유정열
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.999-1011
    • /
    • 1989
  • 본 연구의 목적은 첫째, 재발달 경계층에서의 난류에서지 및 난류전단응력에 대한 전달방정식들의 각 항의 측정자료들을 보다 정확히 제시하고 항들간의 균형을 비교 평가함으로써 비평형 유동으로부터 평형유동으로 회복되는 과정을 검토하고, 둘째, 대표적인 난류 모델들로써 표존 k-.epsilon.모델 및 레이놀즈 응력 모델을 사용한 수치계산을 수행함으로써 이와같은 모델들이 비평형 유동을 서술함에 있어 발생될 수 있는 문제점들을 고찰하는데 있다.

Inter-observer reliability in cone-beam computed tomography assessment of the retromolar canal: A practical plan to improve diagnostic imaging

  • Igarashi, Chinami;Theramballi, Yeshoda Ganesh;Kobayashi, Kaoru
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.181-186
    • /
    • 2022
  • Purpose: This study aimed to investigate inter-observer reliability among observers with different levels of proficiency and the diagnostic imaging reliability of cone-beam computed tomography (CBCT) images of the retromolar canal. Materials and Methods: CBCT images of 307 patients were assessed for the presence of retromolar canals(RMCs) by 3 observers independently. Diagnoses were made twice by each observer at intervals of more than 3 weeks. Interobserver reliability was assessed using the kappa coefficient. One observer had no experience in diagnosis using CBCT images. Therefore, a specialist in diagnostic imaging explained the CBCT images for interpretation and practiced diagnostic imaging together with this observer, while the other observer interpreted the images independently. Thereafter, the observers re-evaluated the images. Results: The interobserver kappa coefficients (including bilateral RMCs) calculated at the first reading were low, ranging from 0.21 to 0.61. Their values ranged from 0.95 (right side) to 1.00 (left side) after one-on-one practice with a diagnostic imaging specialist, while the values ranged from 0.65 (right side) to 0.66 (left side) without one-on-one practice. Conclusion: Diagnostic accuracy was improved through diagnostic imaging practice. To improve the anatomical interpretation of images, it is important to practice diagnostic imaging with a specialist in diagnostic imaging. One-on-one instruction about diagnostic imaging was an effective method of training.

슬관절 연골 평가를 위한 자기공명영상 검사 시 지방 신호 억제 3D T2* Weighted 기법과 지방 신호 억제 3D SPGR 기법의 비교 및 유용성 평가 (The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D T2* weighted Technique and Fat Suppressed 3D SPGR Technique when Examining MRI for Knee Joint Cartilage Assesment)

  • 강성진
    • 한국자기학회지
    • /
    • 제26권6호
    • /
    • pp.219-225
    • /
    • 2016
  • 퇴행성 슬관절 연골 질환의 평가를 위하여 지방 신호 억제 3D SPGR 기법과 지방 신호 억제 3D $T2^*$ weighted 기법을 이용하여 자기공명영상을 획득하였다. 정량적 평가를 위해서 슬관절 연골을 내측대퇴연골(medial femoral cartilage, MFC), 내측경골연골(medial tibial cartilage, MTC), 외측대퇴연골(lateral femoral cartilage, LFC), 외측경골연골(lateral femoral cartilage, LFC), 슬개연골(patella cartilage, Pat) 구역으로 분류하여 관심영역을 설정한 후 각각의 신호강도, 신호 대 잡음비, 대조도 대 잡음비를 측정하였다. 측정된 값은 Mann-Whitney U-검정을 이용 두 기법간의 통계적 유의성을 검증하였다. 정성적 평가를 위해서 각각의 영상을 2명의 영상의학의가 관찰한 후 영상 내 인공음영, 연골의 경계, 조직 간 대조도, 병소의 묘사정도를 4점 척도(1점: 나쁨, 2점: 적당함, 3점: 좋음, 4점: 매우 좋음)로 평가하고, 그 결과를 바탕으로 Kappa-value 검정을 통해 통계적 유의성을 검증하였다. 영상획득에 사용된 장비는 3.0T MR system과 HD T/R 8ch knee array coil을 사용하였다. 정량적 분석결과, SNR 측정값을 토대로 한 두 기법 간의 통계적 유의성 검증 결과 MFC, LFC, LTC, Pat에서는 통계적으로 유의한 결과(p < 0.05)를 보였으나, MTC에서는 유의하지 않은 결과(p > 0.05)를 보였다. CNR 측정값의 통계적 유의성 검증 결과 MFC, LFC, Pat에서는 통계적으로 유의한 결과(p < 0.05)를 보였으나, MTC, LTC에서는 유의하지 않은 결과(p > 0.05)를 보였다. 정성적 분석결과, 영상의 평가항목별 결과 값의 평균을 비교해 보면 3D $T2^*$ weighted 영상에서 조금 높은 결과를 보였고, Kappa-value test를 이용한 두 관찰자간의 일치성 검증에서는 모든 평가항목에서 통계적으로 의미 있는 결과(p < 0.05)를 보였다. 결론적으로 3D $T2^*$ weighted 영상 기법은 3D SPGR 영상기법과의 비교에서 슬관절 연골의 묘사와 주변 조직 간의 대조도 및 병소의 묘사 등 영상의 평가에서 동등 및 그 이상의 진단적 가치를 낼 수 있다.

Schedule-Dependent Effects of Kappa-Selenocarrageenan in Combination with Epirubicin on Hepatocellular Carcinoma

  • Ji, Yu-Bin;Ling, Na;Zhou, Xiao-Jun;Mao, Yun-Xiang;Li, Wen-Lan;Chen, Ning
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권8호
    • /
    • pp.3651-3657
    • /
    • 2014
  • Hepatocellular carcinoma (HCC) has a relatively higher incidence in many countries of Asia. Globally, HCC has a high fatality rate and short survival. Epirubicin, a doxorubicin analogue, may be administered alone or in combination with other agents to treat primary liver cancer and metastatic diseases. However, the toxic effects of epirubicin to normal tissues and cells have been one of the major obstacles to successful cancer chemotherapy. Here, we investigated the effects of epirubicin in combination with kappa-selenocarrageenan on mice with H22 implanted tumors and HepG-2 cell proliferation, immune organ index, morphology, cell cycle and related protein expressions in vivo and in vitro with sequential drug exposure. The inhibitory rate of tumor growth in vivo was calculated. Drug sensitivity was measured by MTT assay, and the King's principle was used to evaluate the interaction of drug combination. Morphological changes were observed by fluorescent microscopy. Cell cycle changes were analyzed by flow cytometry. Expression of cyclin A, Cdc25A and Cdk2 were detected by Western blotting. In vivo results demonstrated that the inhibitory rate of EPI combined with KSC was higher than that of KSC or EPI alone, and the Q value indicated an additive effect. In addition, KSC could significantly raise the thymus and spleen indices of mice with H22 implanted tumors. In the drug sensitivity assay in vitro, exposure to KSC and EPI simultaneously was more effective than exposure sequentially in HepG-2 cells, while exposure to KSC prior to EPI was more effective than exposure to EPI prior to KSC. Q values showed an additive effect in the simultaneous group and antagonistic effects in the sequential groups. Morphological analysis showed similar results to the drug sensitivity assay. Cell cycle analysis revealed that exposure to KSC or EPI alone arrested the cells in S phase in HepG-2 cells, exposure to KSC and EPI simultaneously caused accumulation in the S phase, an effect caused by either KSC or EPI. Expression of cyclin A, Cdc25A and Cdk2 protein was down-regulated following exposure to KSC and EPI alone or in combination, exposure to KSC and EPI simultaneously resulting in the lowest values. Taken together, our findings suggest that KSC in combination with EPI might have potential as a new therapeutic regimen against HCC.

Energy Band Structure, Electronic and Optical properties of Transparent Conducting Nickel Oxide Thin Films on $SiO_2$/Si substrate

  • Denny, Yus Rama;Lee, Sang-Su;Lee, Kang-Il;Lee, Sun-Young;Kang, Hee-Jae;Heo, Sung;Chung, Jae-Gwan;Lee, Jae-Cheol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.347-347
    • /
    • 2012
  • Nickel Oxide (NiO) is a transition metal oxide of the rock salt structure that has a wide band gap of 3.5 eV. It has a variety of specialized applications due to its excellent chemical stability, optical, electrical and magnetic properties. In this study, we concentrated on the application of NiO thin film for transparent conducting oxide. The energy band structure, electronic and optical properties of Nickel Oxide (NiO) thin films grown on Si by using electron beam evaporation were investigated by X-Ray Photoelectron Spectroscopy (XPS), Reflection Electron Energy Loss Spectroscopy (REELS), and UV-Spectrometer. The band gap of NiO thin films determined by REELS spectra was 3.53 eV for the primary energies of 1.5 keV. The valence-band offset (VBO) of NiO thin films investigated by XPS was 3.88 eV and the conduction-band offset (CBO) was 1.59 eV. The UV-spectra analysis showed that the optical transmittance of the NiO thin film was 84% in the visible light region within an error of ${\pm}1%$ and the optical band gap for indirect band gap was 3.53 eV which is well agreement with estimated by REELS. The dielectric function was determined using the REELS spectra in conjunction with the Quantitative Analysis of Electron Energy Loss Spectra (QUEELS)-${\varepsilon}({\kappa},{\omega})$-REELS software. The Energy Loss Function (ELF) appeared at 4.8, 8.2, 22.5, 38.6, and 67.0 eV. The results are in good agreement with the previous study [1]. The transmission coefficient of NiO thin films calculated by QUEELS-REELS was 85% in the visible region, we confirmed that the optical transmittance values obtained with UV-Spectrometer is the same as that of estimated from QUEELS-${\varepsilon}({\kappa},{\omega})$-REELS within uncertainty. The inelastic mean free path (IMFP) estimated from QUEELS-${\varepsilon}({\kappa},{\omega})$-REELS is consistent with the IMFP values determined by the Tanuma-Powell Penn (TPP2M) formula [2]. Our results showed that the IMFP of NiO thin films was increased with increasing primary energies. The quantitative analysis of REELS provides us with a straightforward way to determine the electronic and optical properties of transparent thin film materials.

  • PDF