• Title/Summary/Keyword: k-out of-n systems

Search Result 346, Processing Time 0.031 seconds

Geomagnetism of Daedong Super Group in the Mungyong Area (I) (문경(聞慶) 지역(地域)에 분포(分布)하는 대동누층군(大同累層群)에 대(對)한 고지자기연구(古地磁氣硏究)(I))

  • Min, Kyung-Duck;Lee, Youn-Soo;Kim, Won-Kyun
    • Economic and Environmental Geology
    • /
    • v.23 no.1
    • /
    • pp.81-86
    • /
    • 1990
  • Palemagnetic study on the Deadong Super Group in the Mungyong area has been carried out to obtain the direction of NRM and virtual geomagnetic pole(VGP), and to investigate geomagnetic stratigraphy and geotectonic evolution. Twenty eight core specimens from five sites in Dangog and Bongmyongsan Formations yield magnetically stable results by thermal demagnetization test. Mean declination and inclination of Dangog and Bongmyongsan formations are $52.4^{\circ}E$ and $-57.3^{\circ}$, respectively, which indicate reversal polarity. VGP is located at $1.2^{\circ}N$ in latitude and $269.4^{\circ}E$ in longitude, which is quite different from those of other contemporary formations in China. This suggests that the study area has suffered from differnt tectonic movement caused by Daebo Orogeny occurred in the Korean Peninsula during post-Daedong and pre-Kyongsang Systems. As compared VGP of Daedong Super Group in the Mungyong area with wordwide Mesozoic paleomagnetic polarity stratigraphy, it is correlated with the reverse Epoch in the Graham normal interval. This suggests that the time of formations of Dangog and Bongmyongsan is in the age of 190-195 my.

  • PDF

A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD) (고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구)

  • Kim, J.H.;Koo, J.Y.;Kim, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

Numerical Simulation and Experimental Research of the Flow Coefficient of the Nozzle-Flapper Valve Considering Cavitation

  • Li, Lei;Li, Changchun;Zhang, Hengxuan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.2
    • /
    • pp.176-188
    • /
    • 2017
  • The nozzle-flapper valves are widely applied as a pilot stage in aerospace and military system. A subject of the analysis presented in this work is to find out a reasonable range of null clearance between the nozzle and flapper. This paper has presented a numerical flow coefficient simulation. In every design point, a parameterized model is created for flow coefficient simulation and cavitation under different conditions with varying gap width and inlet pressure. Moreover, a new test device has been designed to measure the flow coefficient and for visualized cavitation. The numerical simulation and test results both indicate that cavitation intensity gets fierce initially and shrinks finally as the gap width varies from small to large. From the curve, the flow coefficient mostly has experienced three stages: linear throttle section, transition section and saturation section. The appropriate deflection of flapper is recommended to make the gap width drop into the linear throttle section. The flapper-nozzle null clearance is optionally recommended near the range of $D_N/16$. Finally through simulation it is also concluded that the inlet pressure plays a little role in the influence on the flow coefficient.

Phosphate Removal from Aqueous Solution according to Activation Methods of Red Mud (알루미늄 제련 폐기물(Red Mud)의 활성화 방법에 따른 수용상의 인산염 제거특성)

  • Kim, I-Tae;Bae, Woo-keun;Kim, Woo-jeong
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.466-472
    • /
    • 2004
  • Red mud is formed as a waste during bauxite refining known as Bayer's process. Its main constituents are iron, aluminium, sodium and silica. The disposal of large quantities of wasted red mud causes a serious ecological problem. In this study, the red mud wasted from the bauxite refinery was studied for phosphate removal from aqueous solution according to activation methods. The influence of heat treatment, and neutralization with sea water and acid treatment level for the optimum conditions for phosphate removal have been determined. Heat treatment combined with acid treatment is most suitable for the removal of phosphate from aqueous solution. The optimal condition was activated with 1 N HCl solution after heating in $600^{\circ}C$ during 4 hours. Acid and heat treatment causes sodalite compounds which hinder the phosphate adsorption to leach out. The adsorption data obtained followed a first-order rate expression and fitted well with the Freundlich Isotherm well.

A Lifetime-Preserving and Delay-Constrained Data Gathering Tree for Unreliable Sensor Networks

  • Li, Yanjun;Shen, Yueyun;Chi, Kaikai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.12
    • /
    • pp.3219-3236
    • /
    • 2012
  • A tree routing structure is often adopted for many-to-one data gathering and aggregation in sensor networks. For real-time scenarios, considering lossy wireless links, it is an important issue how to construct a maximum-lifetime data gathering tree with delay constraint. In this work, we study the problem of lifetime-preserving and delay-constrained tree construction in unreliable sensor networks. We prove that the problem is NP-complete. A greedy approximation algorithm is proposed. We use expected transmissions count (ETX) as the link quality indicator, as well as a measure of delay. Our algorithm starts from an arbitrary least ETX tree, and iteratively adjusts the hierarchy of the tree to reduce the load on bottleneck nodes by pruning and grafting its sub-tree. The complexity of the proposed algorithm is $O(N^4)$. Finally, extensive simulations are carried out to verify our approach. Simulation results show that our algorithm provides longer lifetime in various situations compared to existing data gathering schemes.

A 3 V 12b 100 MS/s CMOS D/A Converter for High-Speed Communication Systems

  • Kim, Min-Jung;Bae, Hyuen-Hee;Yoon, Jin-Sik;Lee, Seung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.4
    • /
    • pp.211-216
    • /
    • 2003
  • This work describes a 3 V 12b 100 MS/s CMOS digital-to-analog converter (DAC) for high-speed communication system applications. The proposed DAC is composed of a unit current-cell matrix for 8 MSBs and a binary-weighted array for 4 LSBs, trading-off linearity, power consumption, chip area, and glitch energy with this process. The low-glitch switch driving circuits are employed to improve linearity and dynamic performance. Current sources of the DAC are laid out separately from the current-cell switch matrix core block to reduce transient noise coupling. The prototype DAC is implemented in a 0.35 um n-well single-poly quad-metal CMOS technology and the measured DNL and INL are within ${\pm}0.75$ LSB and ${\pm}1.73$ LSB at 12b, respectively. The spurious-free dynamic range (SFDR) is 64 dB at 100 MS/s with a 10 MHz input sinewave. The DAC dissipates 91 mW at 3 V and occupies the active die area of $2.2{\;}mm{\;}{\times}{\;}2.0{\;}mm$

137Cs, 40K and 210Po in abiotic components of aquatic ecosystems two rivers in the Can Gio biosphere reserve, Vietnam

  • Ilya G. Sidorov ;Nataliya N. Tereshchenko ;Andrey A. Korotkov;Olga D. Chuzhikova-Proskurnina;Nguyen Trong Hiep ;Aleksandr V. Trapeznikov
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4265-4271
    • /
    • 2022
  • Determination of 137Cs, 40K and 210Po in water, bottom sediments and suspended matter of river systems of the Can Gio Biosphere Reserve, Vietnam was carried out. The average activity concentration of 137Cs in waters of Ca Gau and Long Tau was 0.89 ± 0.14 and 1.08 ± 0.15 Bq m-3 and was comparable to the levels of this radioisotope in waters of the East Sea. The activity concentration of 137Cs in bottom sediments was 2.23 ± 0.81 and 3.63 ± 1.24 Bq kg-1. The activity concentration of 137Cs in water and bottom sediments could be characterized as low. So, the water areas of the Ca Gau and Long Tau rivers could be attributed to areas with insignificant pollution by technogenic radionuclides. The 210Po activity concentration in bottom sediments of the Ca Gau and Long Tau rivers ranged from 9.2 ± 1.2 to 25.5 ± 2.1 Bq kg-1, which is typical for river bottom sediments. Such values indicate the absence of anthropogenic enhancement of the entry of this radionuclide into the Can Gio river systems. The 40K activity concentration varied within 467 ± 42-651 ± 39 Bq kg-1 and represented typical values of potassium content in the bottom sediments of coastal water bodies, subject to a significant influence of the lithogenic component of suspended matter.

Surfactant Washing of Organics from a Contaminated Site I. Clean Up of Hydrocarbon Contaminated Soils (Surfactant washing에 의한 토양 내의 유기물 제거에 관한 연구 I. 탄화수소로 오염된 토양의 정화)

  • Lim, Jong-Choo
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.357-364
    • /
    • 1997
  • The objective of this study was to find optimum nonionic surfactants for clean up of soils contaminated by hydrocarbon oils. PIT(phase inversion temperature) measurements in ternary systems containing pure hydrocarbons, pure nonionic surfactants, and water were carried out and interfacial tensions were measured as a function of time for n-hexadecane oil drops brought into contact with various mixtures of nonionic surfactant and water. Batch surfactant washing experiments were performed based on the measurement, results of PIT and interfacial tension and the results showed that maximum removal of n-hexadecane occurred at the PIT of the system. For the $C_{12}E_5(C_{12}H_{25}O(CH_2CH_2O)_5H)$ system, maximum n-hexadecane removal of 73.4% occurred at the PIT of $52^{\circ}C$. In contrast, n-hexadecane removal at $25^{\circ}C$ and at $60^{\circ}C$, each corresponding to the conditions of below PIT and above PIT of the system, was found to be 57.1% and 57.0% respectively. The maximum removal of a hydrocarbon at the PIT of a system, where the hydrophilic and hydrophobic properties are balanced, was found to be due to the existence of high oil solubilization into a middle-phase microemulsion and ultralow interfacial of the order of $10^{-2}$ to $10^{-3}$ dyne/cm between middle-phase microemulsion and excess oil phase.

  • PDF

Isolation and Identification of Terpenoids from the Flower of Rhododendron yedoense var. poukhanense (산철쭉(Rhododendron yedoense var. poukhanense) 꽃으로부터 Terpenoid의 분리.동정)

  • Hong, Yoon-Hee;Song, Myoung-Chong;Han, Jae-Taek;Jang, Tae-O;Lee, Youn-Hyung;Kim, Sung-Hoon;Kim, Seung-Ae;Park, Mi-Hyun;Baek, Nam-Ln
    • Applied Biological Chemistry
    • /
    • v.46 no.2
    • /
    • pp.144-149
    • /
    • 2003
  • Extracts were obtained from the flower of Rhododendro yedoense var. poukhanense. (7 kg) in 80% aqueous MeOH and successively fractionated with solvent of EtOAc, n-BuOH and $H_2O$, successively. Silica gel and ODS column chromatographies of the EtOAc and n-BuOH fractions were repeatedly carried out by using the various solvent systems to give five terpenoids. Chemical structures of the isolated terpenoids were determined as $2{\alpha},3{\beta}-dihydroxylolean-12-ene$ (1), ursolic acid (2), grayanotoxin IV (3), grayanotoxin I (4) and grayanotoxin III (5) based on the interpretation of several spectral data including 2D-NMR such as $^1H-^1H\;COSY$, HMQC and HMBC.

Analysis of CTOD Tests on Steels for Liquefied Hydrogen Storage Systems Using Hydrogen Charging Apparatus (수소 장입 장치를 활용한 액체수소 저장시스템 강재의 CTOD 시험 분석)

  • Ki-Young Sung;Jeong-Hyeon Kim;Jung-Hee Lee;Jung-Won Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.875-884
    • /
    • 2023
  • Hydrogen infiltration into metals has been reported to induce alterations in their mechanical properties under load. In this study, we conducted CTOD (Crack Tip Opening Displacement) tests on steel specimens designed for use in liquid hydrogen storage systems. Electrochemical hydrogen charging was performed using both FCC series austenitic stainless steel and BCC series structural steel specimens, while CTOD testing was carried out using a 500kN-class material testing machine. Results indicate a notable divergence in behavior: SS400 test samples exhibited a higher susceptibility to failure compared to austenitic stainless steel counterparts, whereas SUS 316L test samples displayed minimal changes in displacement and maximum load due to hydrogen charging. However, SEM (Scanning Electron Microscopy) analysis results presented challenges in clearly explaining the mechanical degradation phenomenon in the tested materials. This study's resultant database holds significant promise for enhancing the safety design of liquid hydrogen storage systems, providing invaluable insights into the performance of various steel alloys under the influence of hydrogen embrittlement.