• 제목/요약/키워드: journal coupling

검색결과 5,836건 처리시간 0.034초

커플링제로 처리된 질화규소 분말의 사출성형 (Injection Molding of Silicon Nitride Powders Treated with Coupling Agents)

  • 송휴섭
    • 한국세라믹학회지
    • /
    • 제30권2호
    • /
    • pp.131-138
    • /
    • 1993
  • The effects of silane coupling agents on the injection molding process were investigated using silicone nitride mixtrues with a binder system containing polypropylene as a major binder (55vol% solid loading). The formation of bonding between silicon nitride powder and coupling agents was confirmed through the analyses of powder surface. The use of coupling agents improved mixing characteristics judged by the torque change during mixing process. the coupling agents also reduced molten viscosity of the mixture considerably, which is a main factor to determine the flow of the mixture. However, the bonding between coupling agents and polymers had a negative effect on the debinding process by retarding the thermal decomposition.

  • PDF

GLOBAL COUPLING EFFECTS ON A FREE BOUNDARY PROBLEM FOR THREE-COMPONENT REACTION-DIFFUSION SYSTEM

  • Ham, Yoon-Mee
    • 대한수학회지
    • /
    • 제43권3호
    • /
    • pp.659-676
    • /
    • 2006
  • In this paper, we consider three-component reaction-diffusion system. With an integral condition and a global coupling, this system gives us an interesting free boundary problem. We shall examine the occurrence of a Hopf bifurcation and the stability of solutions as the global coupling constant varies. The main result is that a Hopf bifurcation occurs for global coupling and this motion is transferred to the stable motion for strong global coupling.

Seismic performance and design method of PRC coupling beam-hybrid coupled shear wall system

  • Tian, Jianbo;Wang, Youchun;Jian, Zheng;Li, Shen;Liu, Yunhe
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.83-96
    • /
    • 2019
  • The seismic behavior of PRC coupling beam-hybrid coupled shear wall system is analyzed by using the finite element software ABAQUS. The stress distribution of steel plate, reinforcing bar in coupling beam, reinforcing bar in slab and concrete is investigated. Meanwhile, the plastic hinges developing law of this hybrid coupled shear wall system is also studied. Further, the effect of coupling ratio, section dimensions of coupling beam, aspect ratio of single shear wall, total height of structure and the role of slab on the seismic behavior of the new structural system. A fitting formula of plate characteristic values for PRC coupling beams based on different displacement requirements is proposed through the experimental date regression analysis of PRC coupling beams at home and abroad. The seismic behavior control method for PRC coupling beam-hybrid coupled shear wall system is proposed based on the continuous connection method and through controlling the coupling ratio, the roof displacement, story drift angle of hybrid coupled shear wall system, displacement ductility of coupling beam.

묶음 대각철근을 적용한 철근콘크리트 연결보의 이력거동 평가 (Cyclic Behavior of Reinforced Concrete Coupling Beams with Bundled Diagonal Reinforcement)

  • 한상환;권현욱;신명수;이기학
    • 한국지진공학회논문집
    • /
    • 제18권3호
    • /
    • pp.117-124
    • /
    • 2014
  • Diagonal reinforced coupling beam of coupled shear walls can provide sufficient strength and stiffness to resist lateral force. However, the reinforcement details for coupling beams required by ACI 318 (2011) are difficult to construct because of the reinforcement congestion and confined interior area. This study presents experimental results about the seismic performance of coupling beams having bundled diagonal reinforcement to improve the workability. Experiments were conducted using half scaled precast coupling beams having an aspect ratio of 2.0. It was observed that the bundled diagonal reinforced coupling beams can develop seismic performance similar to the coupling beams with requirement details specified in ACI 318 (2011).

March Test 기법의 한게 및 알고리즘(반도체 메모리의 커플링 고장을 중심으로) (The Limit of the March Test Method and Algorithms (On Detecting Coupling Faults of Semiconductor Memories))

  • 여정모;조상복
    • 전자공학회논문지A
    • /
    • 제29A권8호
    • /
    • pp.99-109
    • /
    • 1992
  • First, the coupling faults of semiconductor memory are classified in detail. The chained coupling fault is introduced and defined, which results from sequential influencing of the coupling effects among memory cells, and its mapping relation is described. The linked coupling fault and its order are defined. Second, the deterministic “Algorithm GA” is proposed, which detects stuack-at faults, transition faults, address decoder faults, unlinked 2-coupling faults, and unlinked chained coupling faults. The time complexity and the fault coverage are improved in this algorithm. Third, it is proved that the march test of an address sequence can detect 97.796% of the linked 2-coupling faults with order 2. The deterministic “Algorithm NA” proposed can detect to the limit. The time complexity and the fault coverage are improved in this algorithm.

  • PDF

보강상세에 따른 특수전단벽 연결보의 내진성능 (Seismic Performance of Special Reinforced Concrete Coupling Beams with Different Reinforcement Details)

  • 천영수;박지영
    • 토지주택연구
    • /
    • 제6권1호
    • /
    • pp.21-29
    • /
    • 2015
  • 연결보는 지진하중에 효과적으로 저항하기 위하여 적절한 강도, 강성, 변형능력을 지녀야 한다. 특히 스팬-춤 비가 2.0 이하인 대각선다발철근을 갖는 특수전단벽 연결보는 일반 연결보보다 더 높은 강도, 강성, 연성능력을 갖게 되나 대각선다발철근 상세는 시공에 큰 어려움이 발생한다. 본 연구에서는 이러한 문제에 대한 해결방안의 하나로서 대각선다발철근 상세를 대체하기 위한 대안상세들이 실험적으로 연구되었다. 실험결과, 앵글형태로 보강된 SA실험체가 대각방향 보강근을 완전히 제거한 SB시리즈의 실험체와 비교하여 더 안정된 거동을 보였으며, 기존의 대각선다발철근상세를 갖는 CA실험체와 비교하여 유사한 강도, 강성, 에너지소산능력과 변형능력(drift)을 나타내었다.

An Evaluation of the Coupling Coordination Degree of the Yangtze River Delta Port Cluster Based on Coupling Theory

  • Lu Ke;Yong-Sik Oh
    • 한국항해항만학회지
    • /
    • 제48권2호
    • /
    • pp.78-87
    • /
    • 2024
  • To quantitatively assess the correlation between subsystems within a port cluster and the overall coordinated development of the port group, the current paper evaluates the coordinated development of port clusters. First, we construct an evaluation index system for the coupling and coordination of port clusters. Next, we introduce the contribution index of port subsystems, coupling degree, and coupling coordination degree functions to formulate a coupling coordination evaluation model for the port cluster. Finally, we use the Yangtze River Delta port cluster as a case study for validation, specifically using empirical data from 2012 to 2021. The findings reveal distinct phased characteristics in the coupling and coordination of port clusters in the Yangtze River Delta, marked by a notable transition from "maladjustment" to "coordination." Further, sustained high coupling values over a decade indicate a significant level of competition and cooperation among ports within the Yangtze River Delta port cluster. Over time, this competitive and collaborative dynamic has progressively evolved toward a more positive and structured direction. Lastly, it is expected that the evaluation model proposed in this paper can be extrapolated to other port clusters to gauge the extent of coordinated development, thereby facilitating horizontal comparisons and vertical analyses.

Performance based evaluation of RC coupled shear wall system with steel coupling beam

  • Bengar, Habib Akbarzadeh;Aski, Roja Mohammadalipour
    • Steel and Composite Structures
    • /
    • 제20권2호
    • /
    • pp.337-355
    • /
    • 2016
  • Steel coupling beam in reinforced concrete (RC) coupled shear wall system is a proper substitute for deep concrete coupling beam. Previous studies have shown that RC coupled walls with steel or concrete coupling beam designed with strength-based design approach, may not guarantee a ductile behavior of a coupled shear wall system. Therefore, seismic performance evaluation of RC coupled shear wall with steel or concrete coupling beam designed based on a strength-based design approach is essential. In this paper first, buildings with 7, 14 and 21 stories containing RC coupled shear wall system with concrete and steel coupling beams were designed with strength-based design approach, then performance level of these buildings were evaluated under two spectrum; Design Basis Earthquake (DBE) and Maximum Considered Earthquake (MCE). The performance level of LS and CP of all buildings were satisfied under DBE and MCE respectively. In spite of the steel coupling beam, concrete coupling beam in RC coupled shear wall acts like a fuse under strong ground motion.

Chemical Coupling between Horizontal Cells in the Catfish Retina

  • Lee, Sung-Jong;Jung, Chang-Sub;Bai, Sun-Ho
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제2권1호
    • /
    • pp.21-30
    • /
    • 1998
  • The effects of GABA and glutamate on the horizontal cells were explored by an intracellular recording method to discern the mechanisms of receptive field formation by chemical coupling in the catfish outer retina. The results suggest that the horizontal cells of the catfish retina might use GABA as their transmitters and that the GABAergic system contributes to the formation of receptive fields of the horizontal cells. GABAC receptors may be involved in a chemical coupling between horizontal cells and concerned with the depolarizing actions by GABA on horizontal cells in the catfish retina. Since the chloride equilibrium potential is more positive than the dark membrane potential in horizontal cells, GABA released from a horizontal cell may depolarize the neighboring horizontal cells. Thus a chemical coupling between horizontal cells may be formed. $GABA_A$ receptors also may be involved in the negative feedback mechanism between photoreceptor and horizontal cell. And glutamate may be involved in connecting positive and negative feedback systems since it potentiated the GABA's actions. Therefore, it is presumed that large receptive fields in the catfish retina are formed not only by electrical coupling but also by chemical coupling between horizontal cells. And information travels laterally by pathways involving both electrical coupling composed of gap junctions and chemical coupling in the retinal network.

  • PDF

EBeam-촉매 Coupling을 이용한 톨루엔 제어 특성 연구 (Removal Efficiency Of Toluene by EBeam-Catalyst Coupling System)

  • 박강남;김기준;김조천;선우영;송희남
    • 한국대기환경학회지
    • /
    • 제21권6호
    • /
    • pp.667-673
    • /
    • 2005
  • An EBeam (electron beam)-catalyst coupling technique has been developed to control aromatic volatile organic compounds (VOCs) by annexing the catalyst with already existing EBeam technology. In this study, toluene emitted from various industrial coating processes was selected as a representative VOC. The concentration of toluene of concern was 200 ppm. There was an increase in the removal efficieny of toluene by increasing the absorbed dose (kGy) in the EBeam-only and the EBeam-catalyst coupling systems. Compared to EBeam-only system under the same existing EBeam-Pt $1\%$ coupling conditions, EBeam-Pt $1\%$ coupling system revealed 36, 29, 30$\%$ increase in toluene treatmenet at (5, 6.7, 8.7 kGy), respectively. In addition, $O_{3}$ was decreased and CO, $CO_{2}$ were increased by increasing the absorbed dose (kGy) in the EBeam-catalyst (Pt $1\%$, Cu $1\%$) coupling systems. Therefore, it was concluded that the EBeam-catalyst coupling system had a synergy effect on toluene control, compared to the EBeam-only system.