• Title/Summary/Keyword: joint protection

Search Result 172, Processing Time 0.031 seconds

ELECTRICAL FIRE (전기화재)

  • Park, Heon-Sik
    • Fire Protection Technology
    • /
    • s.11
    • /
    • pp.13-22
    • /
    • 1991
  • To understand electrical fire, the cause of it is classified into overcurrent, short circuit, leak, joint, overheat, accumulation of heat, spark, deterioration of insulation, static electricity, and lightning etc. and explained. And then by the precautions to it, proposed to the improvement of electric products, the completeness of safecty management and the use of alarm systems.

  • PDF

The effect of cathodic protection system by means of zinc sacrificial anode on pier in Korea

  • Jeong, Jin-A;Jin, Chung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1206-1211
    • /
    • 2014
  • This study has been conducted to confirm the effect of sacrificial anode cathodic protection system for 90 days to protect corrosion on pier that is located in Korea. The cathodically protected structure was a slab and a pile cap. Before the construction of cathodic protection system, the macrography was carried out. As a result of the macrography, many corrosion traces were confirmed in this structure. The trace was mainly focused on joint and zones that concrete cover was eliminated. To apply the cathodic protection system, many onsite techniques have been adopted. In addition, to confirm the inner state of steel in concrete properly, a corrosion monitoring sensor (DMS-100, Conclinic Co. Ltd) has been applied. Test factors were corrosion & cathodic protection potential, 4 hour depolarization potential, resistivity and current density. After 90 days from the installation of cathodic protection system, it could confirm that proper corrosion protection effect was obtained by considering the result of tests.

Structural Behavior of Beam-Column Joints Consisting of Composite Structures

  • Lee, Seung-Jo;Park, Jung-Min;Kim, Wha-Jung
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.111-120
    • /
    • 2002
  • This study proposes a joint model consisting of different types of members as a new structural system, and then investigates the resulting structural behavior. The joint model consists of a concrete-filled steel tube column (CFT) together with a steel reinforced concrete at the end plus reinforced concrete beam at the center. For comparison, two other joint models were designed, that are, a CPT with a reinforced concrete beam, and a CFT with a steel reinforced concrete at the end plus steel concrete beam at the center, then their joint capacity and rigidity, energy absorption capacity, etc., were all investigated. From the results, the CFT column with a steel reinforced concrete at the end plus steel concrete beam at the center was outstanding in terms of its capacity and rigidity. The results of this analysis demonstrate that an adequate connection type and reinforcement method with different materials of increasing the rigidity, thereby producing a capacity improvement along with protection from pre-fractures.

  • PDF

A Study on the Evaluation of Tensile Performance According to Pareral Jointing Methods of the Sheet Membrane Waterproofing System (방수시트의 평행접합방법에 따른 인장성능 평가연구)

  • Lee Jeoung-Yun;Oh Mi-Hyun;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.39-44
    • /
    • 2004
  • A heat and room temperature construction method of asphalt have been mainly applying to rooftop waterproofing in concrete structure, and the rest construction method are sheet, membrane and mortar waterproofing construction method. In particular, joint method in sheet waterproof method is as overlap joint which on being reinforced with fiber and tape, have been applying for job site to mechanical fix using protection disk and anchorage and metal ironwork on the end of sheet. These construction method cause cutting off joint of sheet as behavior of structure according to repairs of sheet itself and thermal conduct, outdoor air environment. In conclusion, we analyzed and examined the application of various sheets and piece ashes about superior 'I' joint which divide from one and the other sheet and progressed about joint construction method of fixing method for overlap.

  • PDF

Experimental evaluation of fire protection measures for the segment joint of an immersed tunnel (침매터널 세그먼트조인트의 내화 대책에 대한 실험적 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Kim, Heung-Youl;Jo, Bong-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.177-197
    • /
    • 2011
  • In this study, a series of fire experiments under $HC_{inc}$ and ISO834 (duration of 4 hour) fire scenarios were carried out for three different types of fire protection measures for the segment joint to evaluate their applicabilities to an immersed tunnel. The experimental results revealed that an expansion joint installed to allow relative movements between concrete element ends in an segment joint is the most vulnerable to a severe fire. For the fire protection measure where the originally designed steel plates at an expansion joint arc replaced by fire-resistant boards, the experiments showed that they cannot achieve good fireproofing performance under both $HC_{inc}$ fire scenario and ISO834 (4 hour) fire scenarios since the installation of fire-resistant boards results in the reduction of the sprayed fire insulation thickness. On the other hand, the application of modified bent steel plates replacing the original steel plates was proved to be very successful in fireproofing of the expansion joint due to more sprayed materials filled in bent steel plate than in the original design concept as well as higher adhesion between the steel plate and the sprayed fire insulation layer.

Literature Study About Shoulder Joint Function of Overhead Players (상지사용 선수들의 어깨관절기능에 관한 문헌연구)

  • Kim, In-Seop;Lee, Byoung-Kwon;Cho, Mi-Suk;Jang, Chel;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • Purpose : The purpose of this study is a research on the evaluation about shoulder joint function. Methods : It's based on the reference books. Result : Shoulder joint has the biggest ROM in human body, and it is a joint that stability and mobility are required at the same time sport art. Especially, function of shoulder joint than other what item players of more important overhead item correct diagnosis and evaluation for shoulder joint injury require. Measurement equipment for shoulder joint is helping a lot of incorrect diagnosis and analysis about shoulder joint function of overhead players through a lot of developments. Conclusion : I think a lot of helps torture in motor ability elevation of players and player protection as analysis by special quality in item of overhead players.

  • PDF

The Anatomy and Biomechanics of knee joint for orthopedic local taping (슬관절의 정형의학적 국소 테이핑을 위한 해부학과 생체역학에 관한 문헌적 고찰)

  • Lim, Hyun-Dai;Kim, Hye-Won;Kim, Yong-Kwon
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.4
    • /
    • pp.177-184
    • /
    • 2002
  • The knee joint is composed of 3 skeletons that is the femoral bone, the tibial bone, and the patella bone. The tibiofemoral pint and patellofemoral pint act with the meniscus, so these function that is maintain the stabilities by the surrounding soft tissue is complex. The protection mechanism(muscle tension) of the surrounding muscles for the joint disease(Arthritis) limits consistently the motion of the pint to decrease the internal pressure of the joint, and these muscle tension acts with abnormal function for the surrounding tissue and the joint, sometimes the contracture is developed, if the joint with disease is not recovery or treated within early time. So we worked out efficient orthopedic local taping for the patient who is complained of the knee pint pain using the literature investigation about the anatomical structure and the biomechanics of the knee pint for the muscle and the pint problem esp, the rotation of the tibia, the dislocation of the patella, and the motion of the meniscus that is developed due to tension of surrounding muscles of the knee pint. And application of the pint mobilization, the stretching, and the muscle strengthening exercise for the pint will become successful treatment for the joint disease.

  • PDF

A Fundamental Research on the Safety Facilities of Railroad (철도 선로안전시설에 관한 기초연구)

  • Lee Seong-Won;Kim Seung-Hwan;Shin Seung-Kyo;Kim Tae-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.550-555
    • /
    • 2005
  • In this research, safety requirements for guard rail, buffer stop, car stop scotch block, protection device, fire protection facilities, safety siding, escape facilities and inundation protection facilities are studied to establish a standard. First, various kinds of guard rails and their construction methods are investigated. Researches on the level difference of main track and guard rail, joint, length, and fastening force of guard rail are done. Second, the classification of buffer stop and car stop scotch block and its characteristics are examined, and the impact force, speed limit and capacity of buffer stop are summarized. Details of protection device, fire protection facilities, safety siding, escape facilities and inundation protection facilities are also investigated. From this fundamental research results, basic data on the safety facilities of railroad system are established.

  • PDF

Study on the police's protection·support of victims-declaring the Victims Protection years (피해자보호원년을 선언한 경찰의 범죄피해자 보호·지원에 관한 연구)

  • Gong, Jung-Sik
    • Korean Security Journal
    • /
    • no.45
    • /
    • pp.7-35
    • /
    • 2015
  • South Korea's socioeconomic status is high enough to support services for the protection of crime victims. Until now, the Ministry of Justice was the only institution to protect and support the victims, but recently the national police is included. This is considered preferable, since the police is the one to contact the victims first- they can provide immediate support after the incident. Several limits in current laws and crime protection system exist. Therefore, given the importance of protecting victims, model of public-private joint forms should be considered. In premise of establishing a new relationship between the public-private joint system of justice and the maintenance, the range of police's involvement with crime supports will be determined. In the case of developed countries, the police and private organizations maintain close cooperation, appearing as substantial care and support for crime victims. Therefore this study reviews the problems in crime victim protection, assistance from the police stage, and suggest the improvements as follows. The first is to redefine the role of the police who first contacted in the crime victims protection support, the second is to establish a permanent cooperation framework, such as victims specialized police, victims protection agency, the third is to develop services for victim protection available from the police stage, and the fourth, opening Victim Support Center functioning as a temporary accommodation or safety zone for the personal protection of victims. The fifth is to regularize solution conference for victims' protection, and the sixth is to divide of roles in state organization government in charge of victim's protection and local government responsible for victim's support.

  • PDF

Joint Source Channel Coding for H-263+ Based Video by Using the Unequal Error Protection Technique (H.263+ 기반 영상 소스 채널 결합 부호화기의 불균등 오류 보호(UEP) 기법 연구)

  • 이상훈;최윤식
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.45-48
    • /
    • 2001
  • Unequal Error Protection(UP) is reasonable scheme in transmission of compressed video with low bit rate. Because it offers the error correction ability each other data according to the Source Significance Information. Hence it can also be flexible to the given channel environment on the video transmission. This paper propose the joint source channel coding through the UEP in consideration of the hierarchical structure of H.263+ based video and the influence of the transmission error. It especially proposes the error-resilient video transmission technique which can reduce complexity of channel coder & decoder by partitioning the video data with a frame. As the result of the proposed algorithm, it is possible to increase the quality of reconstructed video in the error environment without creating additional bits.

  • PDF