• 제목/요약/키워드: joint intensity

검색결과 396건 처리시간 0.034초

평판 구조물의 진동 파워흐름해석을 위한 비보존 조인트 개발 (Development of Compliant and Dissipative Joints in Coupled Thin Plates for Vibrational Energy Flow Analysis)

  • 송지훈;홍석윤
    • 한국소음진동공학회논문집
    • /
    • 제18권10호
    • /
    • pp.1082-1090
    • /
    • 2008
  • In this paper, a general solution for the vibrational energy and intensity distribution through a compliant and dissipative joint between plate structures is derived on the basis of energy flow analysis (EFA). The joints are modeled by four sets of springs and dashpots to show their compliancy and dissipation in all four degrees of freedom. First, for the EFA, the power transmission and reflection coefficients for the joint on coupled plate structures connected at arbitrary angles were derived by the wave transmission approach. In numerical applications, EFA is performed using the derived coefficients for coupled plate structures under various joint properties, excitation frequencies, coupling angles, and internal loss factors. Numerical results of the vibrational energy distribution showed that the developed compliant and dissipative joint model successfully predicted the joint characteristics of practical structures vibrating in the medium-to-high frequency ranges. Moreover, the intensity distribution of a compliant and dissipative joint is described.

악관절 후방부착부에 있어서 MRI 신호변화에 대한 고찰 (A STUDY ON THE CHANGES OF MR SIGNAL INTENSITY OF POSTERIOR ATTACHMENT OF THE TEMPOROMANDIBULAR JOINT)

  • 정주성;허원실;정훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권1호
    • /
    • pp.93-107
    • /
    • 1997
  • Magnetic resonance imaging has been used in the temporomandibular joint(TMJ) primarily to define morphology and positional relationship of associating structures. This report examines signal intensity characteristics of the posterior attachment as they related to the severity of internal derangement. Fifty six joints in 35 patients with a history of TMJ dysfunction were imaged writ MR using $T_1$-weighted spin echo sequence. According to disk position, ability to reduction, and the presence of osteoarthritis, the joints were categorized into three groups. A group 1 was anterior disk displacement with reduction; a group 2 was anterior disk displacement without reduction; a group 3 was anterior disk displacement without reduction and condyle had osteoarthritic change. The control group was determined by the clinical absence of any signs or symptoms of current or past TMJ pain and dysfunction. Calculated the relative value of MR signal intensity in posterior attachment and disk to cerebral cortex of temporal lobe by means of computer program, we have compared them with each groups. The result showed statistically little significant difference of disk signal intensity among each groups. but, signal intensity from posterior attachment in group 2 and 3 were significantly(p<0.05) decreased than control group. this might reflect an fibrosis or hyalinization of posterior attachment, which was part of remodeling process that occurs in disk displacement without reduction. However, this study could not demonstrate histologic confirmation of the decreased signal intensity in the posterior attachment. So, further investigation could be needed to understand the association between them.

  • PDF

MRI T2강조영상에서 측두하악관절 원판 후 조직의 상대적 신호 강도에 대한 연구 (THE RELATIVE SIGNAL INTENSITY OF RETRODISCAL TISSUE IN TMJ USING A T2-WEIGHTED MRI)

  • 예영근;이상화;윤현중
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권5호
    • /
    • pp.457-462
    • /
    • 2005
  • The aim of this study is to evaluate the relative signal intensity of TMJ retrodiscal tissue in T2-weighted MRI as diagnostic marker of temporomandibular disorder(TMD). 58 temporomandibular joints from 29 TMD patients (14 men & 15 women) were evaluated. The relative signal intensity of retrodiscal tissue in T2-weighted MRI was referenced to brain gray matter same size of the region of interest(ROI). The collected data was compared to disc positions (normal, anterior disc displacement with reduction, anterior disc displacement without reduction), the presence of joint effusion. The relative signal intensity of retrodiscal tissue was significantly increased when the disc was displaced without reduction. And the relative signal intensity of retrodiscal tissue was significantly increased when joint effusion was present. The results suggest that evaluating the relative signal intensity of TMJ retrodiscal tissue using a T2-weighted MRI is valuable as a non-invasive tool for diagnosing the procession of TMD.

측두악관절 잡음자의 교합접촉에 관한 연구 (A STUDY ON THE OCCLUSAL CONTACT OF THE SUBJECTS WITH TEMPOROMANDIBULAR JOINT SOUND)

  • 윤광현;강동완
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.51-61
    • /
    • 1993
  • The purpose of this study was to evaluate a possible occlusal contributing factor on the pathogenesis of temporomandibular joint sound by a new computer aided method for analysis of occlusal contact. 20 subjects without temporomandibular joint sound as control group and 20 subjects with temporomandibular joint sound as experimental group in the TMJ clinic, dental infirmary, School of Dentistry, Chosun University were selected so as to investigate the distribution and intensity of the bilateral occlusal contacts on silicone rubber bites in habitual intercusal position through a computer aided system. The following results were obtained : 1. The distribution and intensity of the occlusal contact could be analyzed and expressed as color density value per levels by this computer aided method. 2. There was not statistical significance between control and experimental group in total occlusal contacts. 3. There was statistical significance between control and experimental group In the total difference of right and left occlusal contacts.(P<0.05).

  • PDF

팔꿉관절 운동강도 설정 및 측정을 위한 최대굴곡력 예측 (Prediction of Maximal Flexion Strength for Exercise Intensity Setting and Measurement in Elbow Joint)

  • 장지훈;김재민;김연규;김진철;조태용;김윤정;이상식
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1628-1633
    • /
    • 2017
  • The purpose of this study was to identify the difference and correlation in elbow joint maximal flexion strength according to measurement methods and characteristics of muscular contraction, and to develop the predictive equation of elbow joint maximal flexion strength for the optimal exercise intensity setting and accurate measurement. Subjects were 30 male university students. Elbow joint maximal flexion strength of isokinetic contraction, isometric contraction at $75^{\circ}$ elbow joint flexion position, isotonic concentric 1RM, manual muscle strength (MMT) were measured with isokinetic dynamometer, dumbbell, and manual muscle tester. Pearson's r, linear regression equation, and multiple regression equation between variables were calculated. As a result, the highest value was isometric contraction. The second highest value was MMT. The third highest value was isokinetic contraction. 1RM was the lowest. Predictive equations of elbow joint maximal flexion strength between isometric and isokinetic contraction, between isometric contraction and 1RM, among isometric contraction, 1RM, and body weight were developed. In conclusion, 1RM and isokinetic elbow joint maximal flexion strength could be seemed to underestimate the practical elbow joint maximal flexion strength. And it is suggested that the developed predictive equations in this study should be useful in criteria- and goal-setting for resistant exercise and sports rehabilitation after elbow joint injury.

프루브 길이에 따른 A5052 겹치기 마찰교반접합 특성 (Characteristics of Friction Stir Lap Welded A5052 with Probe Length)

  • 고영봉;강채원;최준웅;박경채
    • 한국표면공학회지
    • /
    • 제42권6호
    • /
    • pp.294-300
    • /
    • 2009
  • The Friction Stir Welding (FSW) has mainly been used for making butt joints in Al alloys. The development of Friction Stir Lap Welding (FSLW) would expand the number of applications. In this study, for effective application on thin aluminum alloy lap joint, non-heat treatment A5052 alloys were joined by FSLW with the length of probe 2.3 mm and 3.0 mm. Investigating the characteristics of joint area showed the results were as below ; When the length of probe was 2.3 mm, good joint area was formed at all welding condition except for 600 rpm-700 mm/min. In the case of 3.0 mm probe length, there was formed good joint area without defects at 1500 rpm-100 mm/min. The width of joint area, position and size of defects were very important factors for FSLW, due to heat input and stirring intensity.

접착이음의 강도평가에 대한 해석 (Analysis for Strength Estimation of Adhesive Joints)

  • 박성완;이장규
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.98-107
    • /
    • 2004
  • The objectives of this research are to establish the criteria of peel occurrence considering the shape of bond terminus and to compare the strength properties of some adhesive joints. The criteria of feel occurrence at the bond terminus was suggested. Peel loads of some adhesive joint(butt joint, T -shape specimen, single lap joint) were determined from tensile tests. Principal stress distributions of these joints were determined from finite element method analysis. Then, peel occurrence was estimated with intensity of stress singularity ' $K_{prin.}$' when the terminus shape was square, with average principal stress when the terminus shape was rounded. The conclusions are summarized as follows; (1) In the non-filleted model(e.g., butt joint, T-shape specimen), principal stress shows singularity at the bond terminus, intensity of stress(principal stress) singularity ' $K_{prin.}$&apso; can use as the criteria of peel occurrence at the bond terminus. (2) In the filleted model(e.g., single lap joint), principal stress doesn't show singularity at the bond terminus. Average principal stress can use as the criteria of peel occurrence at the bond terminus.'t show singularity at the bond terminus. Average principal stress can use as the criteria of peel occurrence at the bond terminus.

  • PDF

Prediction of Bending Fatigue Life of Cracked Out-of-Plane Gusset Joint Repaired by CFRP Plates

  • Matsumoto, Risa;Komoto, Takafumi;Ishikawa, Toshiyuki;Hattori, Atsushi;Kawano, Hirotaka
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1284-1296
    • /
    • 2018
  • Carbon fiber reinforced polymer (CFRP), plates bonding repair method is one of the simple repair methods for cracked steel structures. In this study, the influence of width of CFRP plates on bending fatigue life of out-of-plane gusset joint strengthened with CFRP plates was investigated from the experimental and numerical point of view. In the bending fatigue test of cracked out-of-plane gusset joint strengthened with CFRP plates, the effect of width of CFRP plates on crack growth life was clarified experimentally. Namely, it was revealed that the crack growth life becomes larger with increasing the width of CFRP plates. In the numerical approach, the stress intensity factor (SIF) at the surface point of a semi-elliptical surface crack was estimated based on the linear fracture mechanics. Furthermore, the extended fatigue life of cracked out-of-plane gusset joint strengthened with CFRP plates was evaluated by using the estimated SIF at the surface point and the empirical formula of the aspect ratio of semi-elliptical crack. As the results of numerical analysis, the estimated fatigue life of the specimen strengthened with CFRP plates showed the good agreement with the test results.

입체사진측량기법을 이용한 광산 갱도 내 불연속면 조사에 대한 조도의 영향에 관한 연구 (Effect of Photographing Light Intensity on Rock Joint Survey in Mine Tunnels using Stereophotogrammetry)

  • 한정훈;송재준;조영도
    • 터널과지하공간
    • /
    • 제19권6호
    • /
    • pp.517-525
    • /
    • 2009
  • 입체사진측량기법이란 대상면에 대하여 두 장 이상의 사진 영상을 취득한 후 이 영상을 이용하여 대상면의 공간 정보를 추출하는 방법이다. 본 연구에서는 광산 갱도 내에 존재하는 암반절리조사에 입체사진측량기법을 적용하였다. 클리노콤파스를 이용하여 두 곳의 광산터널에서 불연속면 정보를 수집하고, 광산에서의 영상 취득시 조도의 영향을 평가하기 위하여 불연속면 조사 대상면에 대하여 조도 변화를 주어 영상을 취득한 후 입체사진측량기법에 기반하여 분석하였다. 클리노콤파스를 이용한 측정치와의 비교를 통하여 입체사진측량기법에 의한 해석의 정확도를 분석하고 광산 갱도 내에서 입체사진측량기법을 적용하기 위한 적절한 조도범위를 찾고자 하였다.

운동형태별 밸런스 테이핑 적용이 EMG 활동 및 혈중 피로물질 반응에 미치는 영향 (The effects of EMG activity and blood fatigue makers on balance taping treatment by exercise type)

  • 이효성;이용식;변재철
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.271-284
    • /
    • 2004
  • The purpose of this study was to analyse the EMG activity of selected muscles with balance taping treatment and blood fatigue makers which accumulated during exercise of progressive maximal intensity. Ten male college students who did not experience any cardiovascular and musculo-skeletal disease were participated in this study. Balance taping were applied to rectus femoris, vastus medialis, vastus lateralis, biceps femoris, semitendinous, semimembranous, and around knee joint. Isokinetic knee joint flexion/extension force, EMG activity, lactate and ammonia as blood fatigue makers during progressive maximal intensity exercise were measured for with/without applying balance taping. The results indicated that although flexion force of total work at $60^{\circ}/sec$ with taping was increased applied taping did not affect to the aerobic exercise ability parameters. Lactate level as blood fatigue makers during progressive maximal intensity exercise after taping was decreased but the ammonia level did not change with same treatment. In isokinetic knee joint test at the angular velocity of $60^{\circ}/sec$, $180^{\circ}/sec$, and $240^{\circ}/sec$ the taping treatment did not affect to any selected muscle EMG activities except maximal EMG of vastus lateralis at $240^{\circ}/sec$.