A Study on Fault Prediction Algorithm and Failure Instance Analysis of Electric Power Relay (전력릴레이 고장사고 사례분석 및 고장예측 알고리즘 연구)

  • Kim, Yong-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.15-16
    • /
    • 2015
  • According to 2014 fire statistical yearbook in the National Fire Data System, a main cause of fire is electrical fire except carelessness fire. Joint/contact badness is the one of the main cause of electrical fire. Furthermore, power relays which are used in electric panel board, motor control center and automation controller, are main element of automation system in the industry field. Overload, voltage unbalance and open-phase due to joint/contact badness of terminal make electric accidents or electrical fires. In order to prevent joint/contact badness of terminal, this paper proposes a sensing circuit of chattering, tracking, arc current, voltage unbalance and open-phase etc. Some experimental tests of the proposed apparatus confirm practicality and validity of the theoretical results.

  • PDF

A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults (접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul;Lee, Bong-Seob;Park, Young-Jic
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.

  • PDF

Analysis on Correlation between Infiltration/Inflow and Defective Rate in Sewer (하수관거 침투수/유입수(I/I)와 불량률과의 상관성 분석)

  • Choi, Seung-cheol;Kwon, Young-sung;Rim, Jay-myoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.221-227
    • /
    • 2005
  • This study has suggested the base data for decision of maintenance ranking and estimation of maintenance effect in the maintenance project of sewers as based on investigation of the defective rate in the sewer through Infiltration/Inflow(I/I) and CCTV analysis. It also analyzed the correlation between I/I and defective rate of sewer. As the result of this study, (1) Defective items of sewer was found out one item each 12.97m with an average. (2) By regression analysis, I/I has high correlation with defective rate of sewer like that $R^2$ is 0.7806. (3) The first thing in the item with bad influence on the I/I was joint badness and secondary was cross connection.

A Study on Verification Test of T-MAT Type Expansion Joint for Railway Bridge (철도교량용 T-MAT형 신축이음장치 완제품 성능시험에 관한 연구)

  • Yoo Moon Sig;Woo Yoon Soo;Kim Hyun Mook;Choi Jong Moon;Yoon Tae Yang;Lee An Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.552-556
    • /
    • 2003
  • Expansion joint is the absorbing structure when the upper structure of bridge have the drying shrinkage and creep from the change of temperature or construction badness. Because it has the fatigue from continuous vehicles traffic. the durability and performance is verified by the static and dynamic loading test In this study. we make the decision that T-MAT type expansion joint is applied in railway bridge and the expansion joint was tested by the criterion of Korea High Speed Rail Construction Authority.

  • PDF

Failure Examples Study Including with timing belt, Constant Velocity Boot and Weather strip on a Car (자동차의 타이밍벨트, 등속조인트 부트, 웨더 스트립에 관련된 고장사례 고찰)

  • Lee, Il Kwon;Lee, Jong Ho;Hwang, Han Sub;Yim, Ha Young;You, Chang Bae;Kim, Young Kyu;Kim, Choo Ha
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.6-11
    • /
    • 2015
  • This paper is to study the examples for rubber damage and weaken reliability of timing belt, constant velocity joint boot and weather strip in vehicle. The first example, when the service man replaced the new timing-belt of rubber material, he assembled the belt that was weaken it's contact surface because of material transform. He knew the abnormally tearing failure by friction action between belt and sprocket. The second example, it certified the fact that the grease is leaked out boot protecting of constant velocity joint by split of rubber surface because of durability badness. The third example, the weather stripe took the minutely tearing because of damage produced the material transform by crack of chemistry change. It certified the production phenomenon of a tiny noise by coming with outside air because of overlapped the rubber of weather stripe when driving after closing the door. Therefore, the driver must always manage the rubber system part of vehicle.